-
Validation of the $^{10}\mathrm{Be}$ Ground-State Molecular Structure Using $^{10}\mathrm{Be}(p,pα)^{6}\mathrm{He}$ Triple Differential Reaction Cross-Section Measurements
Authors:
P. J. Li,
D. Beaumel,
J. Lee,
M. Assié,
S. Chen,
S. Franchoo,
J. Gibelin,
F. Hammache,
T. Harada,
Y. Kanada-En'yo,
Y. Kubota,
S. Leblond,
P. F. Liang,
T. Lokotko,
M. Lyu,
F. M. Marqués,
Y. Matsuda,
K. Ogata,
H. Otsu,
E. Rindel,
L. Stuhl,
D. Suzuki,
Y. Togano,
T. Tomai,
X. X. Xu
, et al. (36 additional authors not shown)
Abstract:
The cluster structure of the neutron-rich isotope $^{10}$Be has been probed via the $(p,pα)$ reaction at 150 MeV/nucleon in inverse kinematics and in quasifree conditions. The populated states of $^{6}$He residues were investigated through missing mass spectroscopy. The triple differential cross-section for the ground-state transition was extracted for quasifree angle pairs ($θ_{p}$, $θ_α$) and co…
▽ More
The cluster structure of the neutron-rich isotope $^{10}$Be has been probed via the $(p,pα)$ reaction at 150 MeV/nucleon in inverse kinematics and in quasifree conditions. The populated states of $^{6}$He residues were investigated through missing mass spectroscopy. The triple differential cross-section for the ground-state transition was extracted for quasifree angle pairs ($θ_{p}$, $θ_α$) and compared to distorted-wave impulse approximation reaction calculations performed in a microscopic framework using successively the Tohsaki-Horiuchi-Schuck-Röpke product wave-function and the wave-function deduced from Antisymmetrized Molecular Dynamics calculations. The remarkable agreement between calculated and measured cross-sections in both shape and magnitude validates the molecular structure description of the $^{10}$Be ground-state, configured as an $α$-$α$ core with two valence neutrons occupying $π$-type molecular orbitals.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
Pulse shape discrimination for GRIT: beam test of a new integrated charge and current preamplifier coupled with high granularity Silicon detectors
Authors:
J. -J. Dormard,
M. Assié,
L. Grassi,
E. Rauly,
D. Beaumel,
G. Brulin,
M. Chabot,
J. -L. Coacolo,
F. Flavigny,
B. Genolini,
F. Hammache,
T. Id Barkach,
E. Rindel,
Ph. Rosier,
N. de Séréville,
E. Wanlin
Abstract:
The GRIT (Granularity, Resolution, Identification, Transparency) Silicon array is intended to measure direct reactions. Its design is based on several layers (three layers in the forward direction, two backward) of custom-made trapezoidal and square detectors. The first stage is 500 μm thick and features 128x128 orthogonal strips. Pulse shape analysis for particle identification is implemented for…
▽ More
The GRIT (Granularity, Resolution, Identification, Transparency) Silicon array is intended to measure direct reactions. Its design is based on several layers (three layers in the forward direction, two backward) of custom-made trapezoidal and square detectors. The first stage is 500 μm thick and features 128x128 orthogonal strips. Pulse shape analysis for particle identification is implemented for this first layer. Given the compacity of this array and the large number of channels involved (>7,500), an integrated preamplifier, iPACI, that gives charge and current information has been developed in the AMS 0.35 μm BiCMOS technology. The design specifications and results of the test bench are presented. Considering an energy range of 50 MeV and an energy resolution (FWHM) of 12 keV (FWHM) for the preamplifier, the energy resolution for one strip obtained from alpha source measurement in real conditions is 35 keV. The current output bandwidth is measured at 130 MHz for small signals and the power consumption reaches 40 mW per detector channel. A first beam test was performed coupling a nTD trapezoidal double-sided stripped Silicon detector of GRIT with the iPACI preamplifier and a 64-channel digitizer. Z=1 particles are discriminated with pulse shape analysis technique down to 2 MeV for protons, 2.5 MeV for deuterons and 3 MeV for tritons. The effect of the strip length due to the trapezoidal shape of the detector is investigated on both the N- and the P-side, showing no significant impact.
△ Less
Submitted 4 November, 2021;
originally announced November 2021.
-
HeCTOr: the $^3$He Cryogenic Target of Orsay for direct nuclear reactions with radioactive beams
Authors:
F. Galtarossa,
M. Pierens,
M. Assié,
V. Delpech,
F. Galet,
H. Saugnac,
D. Brugnara,
D. Ramos,
D. Beaumel,
P. Blache,
M. Chabot,
F. Chatelet,
E. Clément,
F. Flavigny,
A. Giret,
A. Gottardo,
J. Goupil,
A. Lemasson,
A. Matta,
L. Ménager,
E. Rindel
Abstract:
Direct nuclear reactions with radioactive ion beams represent an extremely powerful tool to extend the study of fundamental nuclear properties far from stability. These measurements require pure and dense targets to cope with the low beam intensities. The $^3$He cryogenic target HeCTOr has been designed to perform direct nuclear reactions in inverse kinematics. The high density of $^3$He scatterin…
▽ More
Direct nuclear reactions with radioactive ion beams represent an extremely powerful tool to extend the study of fundamental nuclear properties far from stability. These measurements require pure and dense targets to cope with the low beam intensities. The $^3$He cryogenic target HeCTOr has been designed to perform direct nuclear reactions in inverse kinematics. The high density of $^3$He scattering centers, of the order of 10$^{20}$ atoms/cm$^2$, makes it particularly suited for experiments where low-intensity radioactive beams are involved. The target was employed in a first in-beam experiment, where it was coupled to state-of-the-art gamma-ray and particle detectors. It showed excellent stability in gas temperature and density over time. Relevant experimental quantities, such as total target thickness, energy resolution and gamma-ray absorption, were determined through dedicated Geant4 simulations and found to be in good agreement with experimental data.
△ Less
Submitted 21 August, 2021; v1 submitted 12 May, 2021;
originally announced May 2021.
-
The MUGAST-AGATA-VAMOS campaign : set-up and performance
Authors:
M. Assié,
E. Clément,
A. Lemasson,
D. Ramos,
A. Raggio,
I. Zanon,
F. Galtarossa,
C. Lenain,
J. Casal,
F. Flavigny,
A. Matta,
D. Mengoni,
D. Beaumel,
Y. Blumenfeld,
R. Borcea,
D. Brugnara,
W. Catford,
F. de Oliveira,
N. De Séréville,
F. Didierjean,
C. Aa. Diget,
J. Dudouet,
B. Fernandez-Dominguez,
C. Fougères,
G. Frémont
, et al. (24 additional authors not shown)
Abstract:
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform ex…
▽ More
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform exclusive measurements of direct reactions with the radioactive beams from the SPIRAL1 facility. The performance of the set-up is described through its commissioning and two examples of transfer reactions measured during the campaign. High accuracy spectroscopy of the nuclei of interest, including cross-sections and angular distributions, is achieved through the triple-coincidence measurement. In addition, the correction from Doppler effect of the γ-ray energies is improved by the detection of the light particles and the use of two-body kinematics and a full rejection of the background contributions is obtained through the identification of heavy residues. Moreover, the system can handle high intensity beams (up to 108 pps). The particle identification based on the measurement of the time-of-flight between MUGAST and VAMOS and the reconstruction of the trajectories is investigated.
△ Less
Submitted 21 April, 2021;
originally announced April 2021.
-
Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab
Authors:
T. Horn,
V. V. Berdnikov,
S. Ali,
A. Asaturyan,
M. Carmignotto,
J. Crafts,
A. Demarque,
R. Ent,
G. Hull,
H. -S. Ko,
M. Mostafavi,
C. Munoz-Camacho,
A. Mkrtchyan,
H. Mkrtchyan,
T. Nguyen Trung,
I. L. Pegg,
E. Rindel,
A. Somov,
V. Tadevosyan,
R. Trotta,
S. Zhamkochyan,
R. Wang,
S. A. Wood
Abstract:
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron-Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihi…
▽ More
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron-Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO$_4$ production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
The HPS electromagnetic calorimeter
Authors:
Ilaria Balossino,
Nathan Baltzell,
Marco Battaglieri,
Mariangela Bondi,
Emma Buchanan,
Daniela Calvo,
Andrea Celentano,
Gabriel Charles,
Luca Colaneri,
Annalisa D'Angelo,
Marzio De Napoli,
Raffaella De Vita,
Raphael Dupre,
Hovanes Egiyan,
Mathieu Ehrhart,
Alessandra Filippi,
Michel Garcon,
Nerses Gevorgyan,
Francois-Xavier Girod,
Michel Guidal,
Maurik Holtrop,
Volodymyr Iurasov,
Valery Kubarovsky,
Kenneth Livingston,
Kyle McCarty
, et al. (14 additional authors not shown)
Abstract:
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HP…
▽ More
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier.
△ Less
Submitted 2 February, 2017; v1 submitted 14 October, 2016;
originally announced October 2016.
-
The Heavy Photon Search Test Detector
Authors:
Marco Battaglieri,
Sergey Boyarinov,
Stephen Bueltmann,
Volker Burkert,
Andrea Celentano,
Gabriel Charles,
William Cooper,
Chris Cuevas,
Natalia Dashyan,
Raffaella DeVita,
Camille Desnault,
Alexandre Deur,
Hovanes Egiyan,
Latifa Elouadrhiri,
Rouven Essig,
Vitaliy Fadeyev,
Clive Field,
Arne Freyberger,
Yuri Gershtein,
Nerses Gevorgyan,
Francois-Xavier Girod,
Norman Graf,
Mathew Graham,
Keith Griffioen,
Alexander Grillo
, et al. (39 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th…
▽ More
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.
△ Less
Submitted 4 June, 2015; v1 submitted 23 June, 2014;
originally announced June 2014.
-
PMm2: large photomultipliers and innovative electronics for the next-generation neutrino experiments
Authors:
B. Genolini,
P. Barrillon,
S. Blin,
J. -E. Campagne,
B. Combettes,
S. Conforti,
A. -G. De-haine,
D. Duchesneau,
F. Dulucq,
N. Dumont-Dayot,
J. Favier,
F. Fouché,
R. Hermel,
C. de La Taille,
G. Martin-Chassard,
T. Nguyen Trung,
C. Périnet,
J. Peyré,
J. Pouthas,
L. Raux,
E. Rindel,
P. Rosier,
J. Tassan-Viol,
W. Wei,
A. Zghiche
Abstract:
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a soluti…
▽ More
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a solution is presented here. The very large surface of photodetection is segmented in macro pixels made of 16 hemispherical (12 inches) photomultiplier tubes connected to an autonomous front-end which works on a triggerless data acquisition mode. The expected data transmission rate is 5 Mb/s per cable, which can be achieved with existing techniques. This architecture allows to reduce considerably the cost and facilitate the industrialization. This document presents the simulations and measurements which define the requirements for the photomultipliers and the electronics. A proto-type of front-end electronics was successfully tested with 16 photomultiplier tubes supplied by a single high voltage, validating the built-in gain adjustment and the calibration principle. The first tests and calculations on the photomultiplier glass led to the study of a new package optimized for a 10 bar pressure in order to sustain the high underwater pressure.
△ Less
Submitted 17 November, 2008;
originally announced November 2008.