-
Flares during Eclipses of High Mass X-ray Binary Systems Vela X-1, 4U 1700-37, and LMC X-4
Authors:
Ketan Rikame,
Biswajit Paul,
Rahul Sharma,
V. Jithesh,
KT Paul
Abstract:
In eclipsing X-ray binary systems, the direct X-ray emission is blocked by the companion star during the eclipse. We observe only reprocessed emission that contains clues about the environment of the compact object and its chemical composition, ionization levels, etc. We have found flares in some X-ray binaries during their eclipses. The study of eclipse flares provides additional clues regarding…
▽ More
In eclipsing X-ray binary systems, the direct X-ray emission is blocked by the companion star during the eclipse. We observe only reprocessed emission that contains clues about the environment of the compact object and its chemical composition, ionization levels, etc. We have found flares in some X-ray binaries during their eclipses. The study of eclipse flares provides additional clues regarding the size of the reprocessing region and helps distinguish between different components of the X-ray spectrum observed during the eclipse. In the archival data, we searched for flares during eclipses of high-mass X-ray binaries and found flares in three sources: Vela X-1, LMC X-4, and 4U 1700-37. Comparing spectral properties of the eclipse flare and non-flare data, we found changes in the power-law photon index in all three sources and multiple emission lines in Vela X-1 and 4U 1700-37. The fluxes of prominent emission lines showed a similar increase as the overall X-ray flux during the eclipse flare, suggesting the lines originate in the binary environment and not in the interstellar medium. We also observed a soft excess in 4U 1700-37 that remains unchanged during both eclipse flare and non-flare states. Our analysis suggests that this emission originates from the extremely thin shell of the stellar wind surrounding the photosphere of its companion star. The detection of short (100-200 seconds) count-rate doubling timescale in 4U 1700-37 and LMC X-4 indicates that the eclipse reprocessing occurs in a region larger than, but comparable to the size of the companion star.
△ Less
Submitted 9 March, 2024;
originally announced March 2024.
-
Broadband mHz QPOs and spectral study of LMC X$-$4 with AstroSat
Authors:
Rahul Sharma,
Chetana Jain,
Ketan Rikame,
Biswajit Paul
Abstract:
We report the results of broadband timing and spectral analysis of data from an AstroSat observation of the High Mass X-ray binary LMC X$-$4. The Large Area X-ray Proportional Counter (LAXPC) and Soft X-ray Telescope (SXT) instruments on-board the AstroSat observed the source in August 2016. A complete X-ray eclipse was detected with the LAXPC. The 3$-$40 keV power density spectrum showed the pres…
▽ More
We report the results of broadband timing and spectral analysis of data from an AstroSat observation of the High Mass X-ray binary LMC X$-$4. The Large Area X-ray Proportional Counter (LAXPC) and Soft X-ray Telescope (SXT) instruments on-board the AstroSat observed the source in August 2016. A complete X-ray eclipse was detected with the LAXPC. The 3$-$40 keV power density spectrum showed the presence of coherent pulsations along with a $\sim 26$ mHz quasi-periodic oscillation feature. The spectral properties of LMC X$-$4 were derived from a joint analysis of the SXT and LAXPC spectral data. The 0.5$-$25 keV persistent spectrum comprised of an absorbed high energy cutoff power law with photon index of $Γ\sim$ 0.8 and cutoff at $\sim$16 keV, a soft thermal component with kT$_{BB} \sim$ 0.14 keV and Gaussian components corresponding to Fe K$_α$, Ne \textsc{ix} and Ne \textsc{x} emission lines. Assuming a source distance of 50 kpc, we determined 0.5--25 keV luminosity to be $\sim 2 \times 10^{38}$ erg s$^{-1}$.
△ Less
Submitted 2 December, 2022;
originally announced December 2022.
-
Discovery of Quasi Periodic Oscillations in the persistent X-ray emission of Accreting Binary X-ray Pulsar LMC X-4
Authors:
Ketan Rikame,
Biswajit Paul,
Pragati Pradhan,
KT Paul
Abstract:
We report the discovery of quasi-periodic oscillations (QPOs) in the High Mass X-ray Binary (HMXB) pulsar LMC X-4 in its non-flaring (persistent) state using observations with XMM-Newton. In addition to the 74 mHz coherent pulsations, the persistent emission light curve shows a QPO feature in the frequency range of 20-30 mHz. Quasi-periodic flares have been previously observed from LMC X-4 in obse…
▽ More
We report the discovery of quasi-periodic oscillations (QPOs) in the High Mass X-ray Binary (HMXB) pulsar LMC X-4 in its non-flaring (persistent) state using observations with XMM-Newton. In addition to the 74 mHz coherent pulsations, the persistent emission light curve shows a QPO feature in the frequency range of 20-30 mHz. Quasi-periodic flares have been previously observed from LMC X-4 in observations made with Rossi X-ray Timing Explorer (RXTE). However, this is the first time QPOs have been observed in the persistent emission observations of LMC X-4. QPOs in X-ray binaries are generally thought to be related to the rotation of the inhomogeneous matter distribution in the inner accretion disk. In High Mass X-ray Binaries (HMXBs) such as LMC X-4 where the compact object is a neutron star with a high magnetic field, the radius of the inner accretion disk is determined by the mass accretion rate and the magnetic moment of the neutron star. In such systems, the QPO feature, along with the pulse period and X-ray luminosity measurement helps us to constrain the magnetic field strength of the neutron star. We use considerations of magnetospheric accretion to have an approximate value of the magnetic field strength of the neutron star in LMC X-4.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Noise Characterization of IUCAA Digital Sampling Array Controller (IDSAC)
Authors:
Sabyasachi Chattopadhyay,
A. N. Ramaprakash,
Bhushan Joshi,
Pravin A. Chordia,
Mahesh P. Burse,
Kalpesh Chillal,
Sakya Sinha,
Sujit Punnadi,
Ketan Rikame,
Sungwook E. Hong,
Dhruv Paranjpye,
Haeun Chung,
Changbom Park,
Amitesh Omar
Abstract:
IUCAA Digital Sampling Array Controller (IDSAC) is a flexible and generic yet powerful CCD controller which can handle a wide range of scientific detectors. Based on an easily scalable modular backplane architecture consisting of Single Board Controllers (SBC), IDSAC can control large detector arrays and mosaics. Each of the SBCs offers the full functionality required to control a CCD independentl…
▽ More
IUCAA Digital Sampling Array Controller (IDSAC) is a flexible and generic yet powerful CCD controller which can handle a wide range of scientific detectors. Based on an easily scalable modular backplane architecture consisting of Single Board Controllers (SBC), IDSAC can control large detector arrays and mosaics. Each of the SBCs offers the full functionality required to control a CCD independently. The SBCs can be cold swapped without the need to reconfigure them. Each SBC can handle data from up to four video channels with or without dummy outputs at speeds up to 500 kilo Pixels Per Second (kPPS) Per Channel with a resolution of 16 bits. Communication with Linux based host computer is through a USB3.0 interface, with the option of using copper or optical fibers. A Field Programmable Gate Array (FPGA) is used as the master controller in each SBC which allows great flexibility in optimizing performance by adjusting gain, timing signals, bias levels, etc. using user-editable configuration files without altering the circuit topology. Elimination of thermal kTC noise is achieved via Digital Correlated Double Sampling (DCDS). We present the results of noise performance characterization of IDSAC through simulation, theoretical modeling, and actual measurements. The contribution of different types of noise sources is modeled using a tool to predict noise of a generic DCDS signal chain analytically. The analytical model predicts the net input referenced noise of the signal chain to be 5 electrons for 200k pixels per second per channel readout rate with 3 samples per pixel. Using a cryogenic test set up in the lab, the noise is measured to be 5.4 e (24.3 \muV), for the same readout configuration.
△ Less
Submitted 3 October, 2018;
originally announced October 2018.