Dose rate effects in radiation-induced changes to phenyl-based polymeric scintillators
Authors:
Christos Papageorgakis,
Mohamad Al-Sheikhly,
Alberto Belloni,
Timothy K. Edberg,
Sarah C. Eno,
Yongbin Feng,
Geng-Yuan Jeng,
Abraham Kahn,
Yihui Lai,
Tyler McDonnell,
Christopher Palmer,
Ruhi Perez-Gokhale,
Francesca Ricci-Tam,
Yao Yao,
Zishuo Yang
Abstract:
Results on the effects of ionizing radiation on the signal produced by plastic scintillating rods manufactured by Eljen Technology company are presented for various matrix materials, dopant concentrations, fluors (EJ-200 and EJ-260), anti-oxidant concentrations, scintillator thickness, doses, and dose rates. The light output before and after irradiation is measured using an alpha source and a phot…
▽ More
Results on the effects of ionizing radiation on the signal produced by plastic scintillating rods manufactured by Eljen Technology company are presented for various matrix materials, dopant concentrations, fluors (EJ-200 and EJ-260), anti-oxidant concentrations, scintillator thickness, doses, and dose rates. The light output before and after irradiation is measured using an alpha source and a photomultiplier tube, and the light transmission by a spectrophotometer. Assuming an exponential decrease in the light output with dose, the change in light output is quantified using the exponential dose constant $D$. The $D$ values are similar for primary and secondary do** concentrations of 1 and 2 times, and for antioxidant concentrations of 0, 1, and 2 times, the default manufacturer's concentration. The $D$ value depends approximately linearly on the logarithm of the dose rate for dose rates between 2.2 Gy/hr and 70 Gy/hr for all materials. For EJ-200 polyvinyltoluene-based (PVT) scintillator, the dose constant is approximately linear in the logarithm of the dose rate up to 3400 Gy/hr, while for polystyrene-based (PS) scintillator or for both materials with EJ-260 fluors, it remains constant or decreases (depending on do** concentration) above about 100 Gy/hr. The results from rods of varying thickness and from the different fluors suggest damage to the initial light output is a larger effect than color center formation for scintillator thickness $\leq1$ cm. For the blue scintillator (EJ-200), the transmission measurements indicate damage to the fluors. We also find that while PVT is more resistant to radiation damage than PS at dose rates higher than about 100 Gy/hr for EJ-200 fluors, they show similar damage at lower dose rates and for EJ-260 fluors.
△ Less
Submitted 8 August, 2023; v1 submitted 29 March, 2022;
originally announced March 2022.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trap** rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trap** rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trap** rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.