-
Beam Longitudinal Dynamics Simulation Suite BLonD
Authors:
Helga Timko,
Simon Albright,
Theodoros Argyropoulos,
Konstantinos Iliakis,
Birk Emil Karlsen-Bæck,
Ivan Karpov,
Alexandre Lasheen,
Luis Eduardo Medina,
Danilo Quartullo,
Joël Repond,
Juan Esteban Müller,
Markus Schwarz,
Panagiotis Tsapatsaris,
Georgios Typaldos
Abstract:
The beam longitudinal dynamics code BLonD has been developed at CERN since 2014 and has become a central tool for longitudinal beam dynamics simulations. In this paper, we present this modular simulation suite and the various physics models that can be included and combined by the user. We detail the reference frame, the equations of motion, the BLonD-specific options for radio-frequency parameter…
▽ More
The beam longitudinal dynamics code BLonD has been developed at CERN since 2014 and has become a central tool for longitudinal beam dynamics simulations. In this paper, we present this modular simulation suite and the various physics models that can be included and combined by the user. We detail the reference frame, the equations of motion, the BLonD-specific options for radio-frequency parameters such as phase noise, fixed-field acceleration, and feedback models for the CERN accelerators, as well as the modeling of collective effects and synchrotron radiation. We also present various methods of generating multi-bunch distributions matched to a given impedance model. BLonD is furthermore a well-tested and optimized simulation suite, which is demonstrated through examples, too.
△ Less
Submitted 3 October, 2022; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Neutral Bremsstrahlung emission in xenon unveiled
Authors:
C. A. O. Henriques,
P. Amedo,
J. M. R. Teixeira,
D. Gonzalez-Diaz,
C. D. R. Azevedo,
A. Para,
J. Martin-Albo,
A. Saa Hernandez,
J. J. Gomez-Cadenas,
D. R. Nygren,
C. M. B. Monteiro,
C. Adams,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodriguez,
F. I. G. M. Borges,
N. Byrnes,
S. Carcel,
J. V. Carrion,
S. Cebrian,
E. Church,
C. A. N. Conde
, et al. (68 additional authors not shown)
Abstract:
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that has been postulated to exist in xenon that has been largely overlooked. For photon emission below 1000…
▽ More
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that has been postulated to exist in xenon that has been largely overlooked. For photon emission below 1000 nm, the NBrS yield increases from about 10$^{-2}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at pressure-reduced electric field values of 50 V cm$^{-1}$ bar$^{-1}$ to above 3$\times$10$^{-1}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at 500 V cm$^{-1}$ bar$^{-1}$. Above 1.5 kV cm$^{-1}$ bar$^{-1}$, values that are typically employed for electroluminescence, it is estimated that NBrS is present with an intensity around 1 photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$, which is about two orders of magnitude lower than conventional, excimer-based electroluminescence. Despite being fainter than its excimeric counterpart, our calculations reveal that NBrS causes luminous backgrounds that can interfere, in either gas or liquid phase, with the ability to distinguish and/or to precisely measure low primary-scintillation signals (S1). In particular, we show this to be the case in the "buffer" and "veto" regions, where kee** the electric field below the electroluminescence (EL) threshold will not suffice to extinguish secondary scintillation. The electric field in these regions should be chosen carefully to avoid intolerable levels of NBrS emission. Furthermore, we show that this new source of light emission opens up a viable path towards obtaining S2 signals for discrimination purposes in future single-phase liquid TPCs for neutrino and dark matter physics, with estimated yields up to 20-50 photons/e$^{-}$ cm$^{-1}$.
△ Less
Submitted 13 May, 2022; v1 submitted 5 February, 2022;
originally announced February 2022.
-
LGAD Detector Concept for TOPSiDE Project
Authors:
Kyung-Wook,
Shin,
Jose O. Repond,
David Blyth,
Jessica E. Metcalfe,
Manoj Jadhav,
Abraham Saiden,
Hartmut Sadrozinski
Abstract:
We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of time-of-flight measurement for the TOPSiDE project. To achieve the required timing resolution of 10 ps, the LGAD will be completely monolithic structure, eliminating the par…
▽ More
We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of time-of-flight measurement for the TOPSiDE project. To achieve the required timing resolution of 10 ps, the LGAD will be completely monolithic structure, eliminating the parasitic elements from hybridization. The detector itself will be consist of the LGAD sensor, amplification and discrimination, and time-over-threshold logic components. At this stage, we are optimizing the LGAD sensor design and preparing a discrete component based readout circuitry. In this work, we will present simulation result of a conceptual LGAD silicon detector and constant-fraction discriminator (CFD) circuit implementation. The timing resolution of the conceptual detector was simulated with EDA tools such as Silvaco Atlas and LTSpice with conjunction of a Monte-Carlo simulator to resolve Landau distribution into the circuit readout simulation. The best timing resolution we achieved was 23 ps.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
A Measurement of Proton, Deuteron, Triton and Alpha Particle Emission after Nuclear Muon Capture on Al, Si and Ti with the AlCap Experiment
Authors:
AlCap Collaboration,
Andrew Edmonds,
John Quirk,
Ming-Liang Wong,
Damien Alexander,
Robert H. Bernstein,
Aji Daniel,
Eleonora Diociaiuti,
Raffaella Donghia,
Ewen L. Gillies,
Ed V. Hungerford,
Peter Kammel,
Benjamin E. Krikler,
Yoshitaka Kuno,
Mark Lancaster,
R. Phillip Litchfield,
James P. Miller,
Anthony Palladino,
Jose Repond,
Akira Sato,
Ivano Sarra,
Stefano Roberto Soleti,
Vladimir Tishchenko,
Nam H. Tran,
Yoshi Uchida
, et al. (2 additional authors not shown)
Abstract:
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture o…
▽ More
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture of muons stopped in Al, Si, and Ti in the low energy range relevant for the muon-to-electron conversion experiments. Individual charged particle types were identified in layered silicon detector packages and their initial energy distributions were unfolded from the observed energy spectra. Detailed information on yields and energy spectra for all observed nuclei are presented in the paper.
△ Less
Submitted 1 April, 2022; v1 submitted 19 October, 2021;
originally announced October 2021.
-
The Large Hadron-Electron Collider at the HL-LHC
Authors:
P. Agostini,
H. Aksakal,
S. Alekhin,
P. P. Allport,
N. Andari,
K. D. J. Andre,
D. Angal-Kalinin,
S. Antusch,
L. Aperio Bella,
L. Apolinario,
R. Apsimon,
A. Apyan,
G. Arduini,
V. Ari,
A. Armbruster,
N. Armesto,
B. Auchmann,
K. Aulenbacher,
G. Azuelos,
S. Backovic,
I. Bailey,
S. Bailey,
F. Balli,
S. Behera,
O. Behnke
, et al. (312 additional authors not shown)
Abstract:
The Large Hadron electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High Luminosity--Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent el…
▽ More
The Large Hadron electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High Luminosity--Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent electron-proton and proton-proton operation. This report represents an update of the Conceptual Design Report (CDR) of the LHeC, published in 2012. It comprises new results on parton structure of the proton and heavier nuclei, QCD dynamics, electroweak and top-quark physics. It is shown how the LHeC will open a new chapter of nuclear particle physics in extending the accessible kinematic range in lepton-nucleus scattering by several orders of magnitude. Due to enhanced luminosity, large energy and the cleanliness of the hadronic final states, the LHeC has a strong Higgs physics programme and its own discovery potential for new physics. Building on the 2012 CDR, the report represents a detailed updated design of the energy recovery electron linac (ERL) including new lattice, magnet, superconducting radio frequency technology and further components. Challenges of energy recovery are described and the lower energy, high current, 3-turn ERL facility, PERLE at Orsay, is presented which uses the LHeC characteristics serving as a development facility for the design and operation of the LHeC. An updated detector design is presented corresponding to the acceptance, resolution and calibration goals which arise from the Higgs and parton density function physics programmes. The paper also presents novel results on the Future Circular Collider in electron-hadron mode, FCC-eh, which utilises the same ERL technology to further extend the reach of DIS to even higher centre-of-mass energies.
△ Less
Submitted 12 April, 2021; v1 submitted 28 July, 2020;
originally announced July 2020.
-
Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air
Authors:
S. Ghosh,
J. Haefner,
J. Martín-Albo,
R. Guenette,
X. Li,
A. A. Loya Villalpando,
C. Burch,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ran…
▽ More
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.
△ Less
Submitted 8 September, 2020; v1 submitted 13 July, 2020;
originally announced July 2020.
-
Sensitivity of the NEXT experiment to Xe-124 double electron capture
Authors:
G. Martínez-Lema,
M. Martínez-Vara,
M. Sorel,
C. Adams,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai
, et al. (66 additional authors not shown)
Abstract:
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, b…
▽ More
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, but only observed in $^{78}$Kr, $^{130}$Ba and, recently, $^{124}$Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, $0νECEC$. Here we report on the current sensitivity of the NEXT-White detector to $^{124}$Xe $2νECEC$ and on the extrapolation to NEXT-100. Using simulated data for the $2νECEC$ signal and real data from NEXT-White operated with $^{124}$Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of $^{124}$Xe and for a 5-year run, a sensitivity to the $2νECEC$ half-life of $6 \times 10^{22}$ y (at 90% confidence level) or better can be reached.
△ Less
Submitted 15 March, 2021; v1 submitted 12 June, 2020;
originally announced June 2020.
-
Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture
Authors:
L. Rogers,
B. J. P. Jones,
A. Laing,
S. **ulkar,
K. Woodruff,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz,
M. Diesburg,
R. Dingler
, et al. (67 additional authors not shown)
Abstract:
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta…
▽ More
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
△ Less
Submitted 27 May, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
Radio Frequency and DC High Voltage Breakdown of High Pressure Helium, Argon, and Xenon
Authors:
K. Woodruff,
J. Baeza-Rubio,
D. Huerta,
B. J. P. Jones,
A. D. McDonald,
L. Norman,
D. R. Nygren,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. K. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
A. A. Denisenko,
G. Díaz
, et al. (69 additional authors not shown)
Abstract:
Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is develo** a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly large…
▽ More
Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is develo** a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.
△ Less
Submitted 23 April, 2020; v1 submitted 12 September, 2019;
originally announced September 2019.
-
Low-diffusion Xe-He gas mixtures for rare-event detection: Electroluminescence Yield
Authors:
A. F. M. Fernandes,
C. A. O. Henriques,
R. D. P. Mano,
D. González-Díaz,
C. D. R. Azevedo,
P. A. O. C. Silva,
J. J. Gómez-Cadenas,
E. D. C. Freitas,
L. M. P. Fernandes,
C. M. B. Monteiro,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carríon,
S. Cebrían,
E. Church,
C. A. N. Conde,
T. Contreras
, et al. (66 additional authors not shown)
Abstract:
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC w…
▽ More
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.
△ Less
Submitted 26 November, 2019; v1 submitted 10 June, 2019;
originally announced June 2019.
-
Radiogenic backgrounds in the NEXT double beta decay experiment
Authors:
NEXT Collaboration,
P. Novella,
B. Palmeiro,
M. Sorel,
A. Usón,
P. Ferrario,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz López,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of…
▽ More
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of (0.84$\pm$0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT Collaboration. A spectral fit to this model yields the specific contributions of $^{60}$Co, $^{40}$K, $^{214}$Bi and $^{208}$Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25$\pm$0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5$σ$ after 1 year of data taking. The background measurement in a Q$_{ββ}\pm$100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75$\pm$0.12) events.
△ Less
Submitted 9 September, 2019; v1 submitted 31 May, 2019;
originally announced May 2019.
-
Demonstration of the event identification capabilities of the NEXT-White detector
Authors:
NEXT Collaboration,
P. Ferrario,
J. M. Benlloch-Rodríguez,
G. Díaz López,
J. A. Hernando Morata,
M. Kekic,
J. Renner,
A. Usón,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the dat…
▽ More
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a \TO\ calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of $71.6 \pm 1.5_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ for a background acceptance of $20.6 \pm 0.4_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies.
△ Less
Submitted 11 September, 2019; v1 submitted 30 May, 2019;
originally announced May 2019.
-
Energy calibration of the NEXT-White detector with 1% resolution near Q$_{ββ}$ of $^{136}$Xe
Authors:
J. Renner,
G. Díaz López,
P. Ferrario,
J. A. Hernando Morata,
M. Kekic,
G. Martínez-Lema,
F. Monrabal,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
J. Díaz
, et al. (65 additional authors not shown)
Abstract:
Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($β\beta0ν$) require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1%…
▽ More
Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($β\beta0ν$) require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for $β\beta0ν$ searches.
△ Less
Submitted 18 October, 2019; v1 submitted 30 May, 2019;
originally announced May 2019.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
Electron Drift and Longitudinal Diffusion in High Pressure Xenon-Helium Gas Mixtures
Authors:
A. D. McDonald,
K. Woodruff,
B. Al Atoum,
D. González-Díaz,
B. J. P. Jones,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
G. Díaz,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai
, et al. (61 additional authors not shown)
Abstract:
We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all $E/P$, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient t…
▽ More
We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all $E/P$, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient than theoretical predictions is found at low $E/P$ in pure xenon, below the range of reduced fields usually probed by TPC experiments. A similar effect is observed in xenon-helium gas mixtures at somewhat larger $E/P$. Drift velocities in xenon-helium mixtures are found to be theoretically well predicted. Although longitudinal diffusion in xenon-helium mixtures is found to be larger than anticipated, extrapolation based on the measured longitudinal diffusion coefficients suggest that the use of helium additives to reduce transverse diffusion in xenon gas remains a promising prospect.
△ Less
Submitted 26 June, 2019; v1 submitted 14 February, 2019;
originally announced February 2019.
-
Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models
Authors:
CALICE Collaboration,
M. Chefdeville,
J. Repond,
J. Schlereth,
J. R. Smith,
D. Trojand,
L. Xia,
Q. Zhang,
J. Apostolakis,
C. Grefe,
V. Ivantchenko,
G. Folger,
A. Ribon,
V. Uzhinskiy,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
V. Bocharnikov,
E. Brianne,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel
, et al. (71 additional authors not shown)
Abstract:
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of…
▽ More
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.
△ Less
Submitted 25 January, 2019;
originally announced January 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Study of the loss of Xenon Scintillation in Xenon-Trimethylamine Mixtures
Authors:
A. M. F. Trindade,
J. Escada,
A. F. V. Cortez,
F. I. G. M. Borges,
F. P. Santos,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
F. Ballester,
J. M. Benlloch-Rodríguez,
A. Botas,
S. Cárcel,
J. V. Carríon,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt
, et al. (53 additional authors not shown)
Abstract:
This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was…
▽ More
This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was observed experimentally. Considering the detection limit of the experimental system, if reemission by TMA molecules occurs, it is below 0.3% of the scintillation absorbed in the 160-188 nm range. An absorption coefficient value for xenon VUV light by TMA of 0.43+/-0.03 cm-1.Torr-1 was also obtained. These results can be especially important for experiments considering TMA as a molecular additive to Xe in large volume optical time projection chambers.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.
-
Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System
Authors:
CALICE Collaboration,
J. Repond,
L. Xia,
J. Apostolakis,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
V. Francais,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Gttlicher,
O. Hartbrich F. Krivan,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza
, et al. (84 additional authors not shown)
Abstract:
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles.…
▽ More
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
△ Less
Submitted 12 September, 2018; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Characteristics of fast timing MCP-PMTs in magnetic fields
Authors:
Mohammad Hattawy,
Junqi Xie,
Mickey Chiu,
Marcel Demarteau,
Kawtar Hafidi,
Edward May,
Jose Repond,
Robert Wagner,
Lei Xia,
Carl Zorn
Abstract:
The motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs based on two different designs were tested.The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a s…
▽ More
The motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs based on two different designs were tested.The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a significant improvement (up to 0.7 T) compared to the one utilizing an internal resistor chain design (up to 0.1 T), indicating the importance of individually adjustable voltages. The effects of the rotation angle of the MCP-PMT relative to the magnetic field direction and of the bias voltage between the photocathode and the top MCP were extensively investigated using the MCP-PMT based on the independently biased voltage design. It was found that the signal amplitude of the MCP-PMT exhibits an enhanced performance at a tilt angle of $\pm$8$^{\circ}$, due to the 8$^{\circ}$ bias angle of the MCP pores. The maximum signal amplitude was observed at different bias voltages depending on the magnetic field strength.
△ Less
Submitted 23 August, 2018;
originally announced August 2018.
-
Initial results on energy resolution of the NEXT-White detector
Authors:
J. Renner,
P. Ferrario,
G. Martínez-Lema,
F. Monrabal,
A. Para,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
A. F. M. Fernandes
, et al. (55 additional authors not shown)
Abstract:
One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with th…
▽ More
One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q$_{ββ}$.
△ Less
Submitted 15 October, 2018; v1 submitted 6 August, 2018;
originally announced August 2018.
-
Top-Quark Physics at the CLIC Electron-Positron Linear Collider
Authors:
H. Abramowicz,
N. Alipour Tehrani,
D. Arominski,
Y. Benhammou,
M. Benoit,
J. -J. Blaising,
M. Boronat,
O. Borysov,
R. R. Bosley,
I. Božović Jelisavčić,
I. Boyko,
S. Brass,
E. Brondolin,
P. Bruckman de Renstrom,
M. Buckland,
P. N. Burrows,
M. Chefdeville,
S. Chekanov,
T. Coates,
D. Dannheim,
M. Demarteau,
H. Denizli,
G. Durieux,
G. Eigen,
K. Elsener
, et al. (92 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boso…
▽ More
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of ttH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.
△ Less
Submitted 18 November, 2019; v1 submitted 6 July, 2018;
originally announced July 2018.
-
Electroluminescence TPCs at the thermal diffusion limit
Authors:
C. A. O. Henriques,
C. M. B. Monteiro,
D. González-Díaz,
C. D. R Azevedo,
E. D. C. Freitas,
R. D. P. Mano,
M. R. Jorge,
A. F. M. Fernandes,
J. J. Gómez-Cadenas,
L. M. P. Fernandes,
C. Adams,
V. Álvarez,
L. Arazi,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada
, et al. (56 additional authors not shown)
Abstract:
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small…
▽ More
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.
△ Less
Submitted 30 October, 2018; v1 submitted 15 June, 2018;
originally announced June 2018.
-
Implementation of Maxwell's equations in the reconstruction of the magnetic field in the $g-2$ storage ring
Authors:
Geoffrey T. Bodwin,
Hee Sok Chung,
Jose Repond
Abstract:
We present a method for implementing the constraints that are implied by Maxwell's equations in fits to measurements of the magnetic field in the muon storage ring of the $g-2$ experiment. The method that we use makes use of toroidal-harmonic solutions of Laplace's equation. We point out that the fitting problem can be approximated well as a linear-algebra problem. We have devised an efficient alg…
▽ More
We present a method for implementing the constraints that are implied by Maxwell's equations in fits to measurements of the magnetic field in the muon storage ring of the $g-2$ experiment. The method that we use makes use of toroidal-harmonic solutions of Laplace's equation. We point out that the fitting problem can be approximated well as a linear-algebra problem. We have devised an efficient algorithm for the linear-algebra problem that makes it possible to find a solution for $10^5$ data points and $10^4$ harmonics in less than an hour on a present-day desktop computer. We illustrate our method by applying it to some preliminary measurements of the magnetic field in the $g-2$ storage ring.
△ Less
Submitted 3 July, 2019; v1 submitted 30 May, 2018;
originally announced May 2018.
-
The Next White (NEW) detector
Authors:
F. Monrabal,
J. J. Gómez-Cadenas,
J. F. Toledo,
V. Álvarez,
J. M. Benlloch-Rodríguez,
S. Cárcel,
J. V. Carrión,
R. Esteve,
R. Felkai,
V. Herrero,
A. Laing,
A. Martínez,
M. Musti,
M. Querol,
J. Rodríguez,
A. Simón,
C. Sofka,
J. Torrent,
R. Webb,
J. T. White,
C. Adams,
L. Arazi,
C. D. R. Azevedo,
K. Bailey,
F. Ballester
, et al. (50 additional authors not shown)
Abstract:
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT- White (NEW) apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for $ββ0ν$ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of…
▽ More
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT- White (NEW) apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for $ββ0ν$ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures.
△ Less
Submitted 6 April, 2018;
originally announced April 2018.
-
Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays
Authors:
G. Martínez-Lema,
J. A. Hernando Morata,
B. Palmeiro,
A. Botas,
P. Ferrario,
F. Monrabal,
A. Laing,
J. Renner,
A. Simón,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada
, et al. (52 additional authors not shown)
Abstract:
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Kry…
▽ More
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 $\pm$ 0.010 (stat.) $\pm$ 0.324 (sys.)) % FWHM in the full chamber and (3.804 $\pm$ 0.013 (stat.) $\pm$ 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into resolutions of (0.516 $\pm$ 0.0014 (stat.) $\pm$ 0.0421 (sys.)) % FWHM and (0.4943 $\pm$ 0.0017 (stat.) $\pm$ 0.0146 (sys.)) % FWHM at the $Q_{ββ}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.
△ Less
Submitted 18 September, 2018; v1 submitted 5 April, 2018;
originally announced April 2018.
-
Electron drift properties in high pressure gaseous xenon
Authors:
NEXT Collaboration,
A. Simón,
R. Felkai,
G. Martínez-Lema,
F. Monrabal,
D. González-Díaz,
M. Sorel,
J. A. Hernando Morata,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
L. M. P. Fernandes
, et al. (51 additional authors not shown)
Abstract:
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinol…
▽ More
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.
△ Less
Submitted 28 May, 2018; v1 submitted 5 April, 2018;
originally announced April 2018.
-
Measurement of radon-induced backgrounds in the NEXT double beta decay experiment
Authors:
NEXT Collaboration,
P. Novella,
B. Palmeiro,
A. Simón,
M. Sorel,
C. Adams,
P. Ferrario,
G. Martínez-Lema,
F. Monrabal,
G. Zuzel,
J. J. Gómez-Cadenas,
V. Álvarez,
L. Arazi,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg
, et al. (57 additional authors not shown)
Abstract:
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is…
▽ More
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.
△ Less
Submitted 10 October, 2018; v1 submitted 2 April, 2018;
originally announced April 2018.
-
Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging
Authors:
A. D. McDonald,
B. J. P. Jones,
D. R. Nygren,
C. Adams,
V. Alvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodrıguez,
F. I. G. M. Borges,
A. Botas,
S. Carcel,
J. V. Carrion,
S. Cebrian,
C. A. N. Conde,
J. Dıaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gomez-Cadenas,
D. Gonzalez-Dıaz
, et al. (49 additional authors not shown)
Abstract:
A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), a…
▽ More
A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$σ$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.
△ Less
Submitted 6 February, 2018; v1 submitted 13 November, 2017;
originally announced November 2017.
-
Helium-Xenon mixtures to improve topological signature in high pressure gas Xenon TPCs
Authors:
R. Felkai,
F. Monrabal,
D. Gonzalez-Díaz,
M. Sorel,
N. López-March,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas
, et al. (50 additional authors not shown)
Abstract:
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while kee** nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, a…
▽ More
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while kee** nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15~\%, may reduce drastically the transverse diffusion down to 2.5~mm/$\sqrt{\mathrm{m}}$ from the 10.5~mm/$\sqrt{\mathrm{m}}$ of pure xenon. The longitudinal diffusion remains around 4~mm/$\sqrt{\mathrm{m}}$. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.
△ Less
Submitted 20 December, 2018; v1 submitted 16 October, 2017;
originally announced October 2017.
-
Rate capability and magnetic field tolerance measurements of fast timing microchannel plate photodetectors
Authors:
Junqi Xie,
Mohammad Hattawy,
Mickey Chiu,
Kawtar Hafidi,
Edward May,
Jose Repond,
Robert Wagner,
Lei Xia
Abstract:
Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have tested the rate capability and magnetic field tolerance of 6$\times$6 cm$^{2}$ microchannel plate photodetectors fabricated at Argonne National Laboratory. The micr…
▽ More
Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have tested the rate capability and magnetic field tolerance of 6$\times$6 cm$^{2}$ microchannel plate photodetectors fabricated at Argonne National Laboratory. The microchannel plate photodetector is designed as a low-cost all-glass vacuum package with a chevron pair stack of next-generation microchannel plates functionalized by atomic layer deposition. The rate capability test was performed using Fermilab's 120 GeV primary proton beam, and the magnetic field tolerance test was performed using a solenoid magnetic with tunable magnetic field strength up to 4 Tesla. The measured gain of the microchannel plate photodetector is stable up to 75 kHz/cm$^{2}$, and varies depending on the applied magnetic field strength and the rotation angle relative to the magnetic field direction.
△ Less
Submitted 4 October, 2017;
originally announced October 2017.
-
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
Authors:
CALICE collaboration,
J. Repond,
L. Xia,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
M. A. Thomson,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
F. Krivan,
K. Krüger,
S. Lu,
B. Lutz,
M. Reinecke,
F. Sefkow,
Y. Sudo,
H. L. Tran,
A. Kaplan,
H. -Ch. Schultz-Coulon
, et al. (57 additional authors not shown)
Abstract:
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab…
▽ More
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.
△ Less
Submitted 28 February, 2018; v1 submitted 22 July, 2017;
originally announced July 2017.
-
Higgs Physics at the CLIC Electron-Positron Linear Collider
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
N. Alipour Tehrani,
C. Balázs,
Y. Benhammou,
M. Benoit,
B. Bilki,
J. -J. Blaising,
M. J. Boland,
M. Boronat,
O. Borysov,
I. Božović-Jelisavčić,
M. Buckland,
S. Bugiel,
P. N. Burrows,
T. K. Charles,
W. Daniluk,
D. Dannheim,
R. Dasgupta,
M. Demarteau,
M. A. Díaz Gutierrez,
G. Eigen,
K. Elsener,
U. Felzmann
, et al. (99 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3…
▽ More
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3 TeV. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (e+e- -> ZH) and WW-fusion (e+e- -> Hnunu), resulting in precise measurements of the production cross sections, the Higgs total decay width Gamma_H, and model-independent determinations of the Higgs couplings. Operation at sqrt(s) > 1 TeV provides high-statistics samples of Higgs bosons produced through WW-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes e+e- -> ttH and e+e- -> HHnunu allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.
△ Less
Submitted 5 June, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Combined Preheating on the lattice with applications to Higgs inflation
Authors:
Joël Repond,
Javier Rubio
Abstract:
We use classical lattice simulations in 3+1 dimensions to study the interplay between the resonant production of particles during preheating and the subsequent decay of these into a set of secondary species. We choose to work in a simplified version of Higgs inflation in which the Higgs field non-minimally coupled to gravity plays the role of the inflaton. Our numerical results extend the analytic…
▽ More
We use classical lattice simulations in 3+1 dimensions to study the interplay between the resonant production of particles during preheating and the subsequent decay of these into a set of secondary species. We choose to work in a simplified version of Higgs inflation in which the Higgs field non-minimally coupled to gravity plays the role of the inflaton. Our numerical results extend the analytical estimates in the literature beyond the linear regime and shed some light on the limitations of the analytical techniques. The inclusion of fast and inefficient decays postpones the onset of parametric resonance by depleting the particles produced at the bottom of the potential. In spite of this delay, fermions are shown to play an important role on the destruction of the inflaton field. The limitations of our approach and its applications to a realistic Higgs inflation scenario are also discussed.
△ Less
Submitted 29 July, 2016; v1 submitted 27 April, 2016;
originally announced April 2016.
-
Design, Construction and Testing of the Digital Hadron Calorimeter (DHCAL) Electronics
Authors:
C. Adams,
A. Bambaugh,
B. Bilki,
J. Butler,
F. Corriveau,
T. Cundiff,
G. Drake,
K. Francis,
V. Guarino,
B. Haberichter,
E. Hazen,
J. Hoff,
S. Holm,
A. Kreps,
P. DeLurgio,
L. Dal Monte,
N. Mucia,
E. Norbeck,
D. Northacker,
Y. Onel,
B. Pollack,
J. Repond,
J. Schlereth,
J. R. Smith,
D. Trojand
, et al. (8 additional authors not shown)
Abstract:
A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first ord…
▽ More
A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of the electronic readout system of this prototype calorimeter. The system is based on the DCAL front-end chip and a VME-based back-end.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Design, Construction and Commissioning of the Digital Hadron Calorimeter - DHCAL
Authors:
C. Adams,
A. Bambaugh,
B. Bilki,
J. Butler,
F. Corriveau,
T. Cundiff,
G. Drake,
K. Francis,
B. Furst,
V. Guarino,
B. Haberichter,
E. Hazen,
J. Hoff,
S. Holm,
A. Kreps,
P. DeLurgio,
Z. Matijas,
L. Dal Monte,
N. Mucia,
E. Norbeck,
D. Northacker,
Y. Onel,
B. Pollack,
J. Repond,
J. Schlereth
, et al. (11 additional authors not shown)
Abstract:
A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first ord…
▽ More
A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of this prototype calorimeter.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
DHCAL with Minimal Absorber: Measurements with Positrons
Authors:
The CALICE Collaboration,
B. Freund,
C. Neubüser,
J. Repond,
J. Schlereth,
L. Xia,
A. Dotti,
C. Grefe,
V. Ivantchenko,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg,
A. Irles,
F. Krivan,
K. Krüger
, et al. (78 additional authors not shown)
Abstract:
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on…
▽ More
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
Measurements of the Rate Capability of Various Resistive Plate Chambers
Authors:
M. Affatigato,
U. Akgun,
B. Bilki,
F. Corriveau,
B. Freund,
N. Johnson,
C. Neubueser,
Y. Onel,
J. Repond,
L. Xia
Abstract:
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. This paper reports on measurements of the performance of three different glass RPC designs featuring a different total resistance of the re…
▽ More
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. This paper reports on measurements of the performance of three different glass RPC designs featuring a different total resistance of the resistive plates. The measurements were performed with 120 GeV protons at varying beam intensities
△ Less
Submitted 7 September, 2015; v1 submitted 24 July, 2015;
originally announced July 2015.
-
Experimental Tests of Particle Flow Calorimetry
Authors:
Felix Sefkow,
Andy White,
Kiyotomo Kawagoe,
Roman Pöschl,
José Repond
Abstract:
Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about 10 - 15 years of R\&D, mainly conducted within the CALICE collaboration, for this novel type of detector. The performance of large scale prototypes in beam tests validate the technical concept of particle flow calorimete…
▽ More
Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about 10 - 15 years of R\&D, mainly conducted within the CALICE collaboration, for this novel type of detector. The performance of large scale prototypes in beam tests validate the technical concept of particle flow calorimeters. The comparison of test beam data with simulation, of e.g.\ hadronic showers, supports full detector studies and gives deeper insight into the structure of hadronic cascades than was possible previously.
△ Less
Submitted 17 September, 2015; v1 submitted 21 July, 2015;
originally announced July 2015.
-
Letter of Intent: The Accelerator Neutrino Neutron Interaction Experiment (ANNIE)
Authors:
I. Anghel,
J. F. Beacom,
M. Bergevin,
C. Blanco,
E. Catano-Mur,
F. Di Lodovico,
A. Elagin,
H. Frisch,
J. Griskevich,
R. Hill,
G. Jocher,
T. Katori,
F. Krennrich,
J. Learned,
M. Malek,
R. Northrop,
C. Pilcher,
E. Ramberg,
J. Repond,
R. Sacco,
M. C. Sanchez,
M. Smy,
H. Sobel,
R. Svoboda,
S. M. Usman
, et al. (8 additional authors not shown)
Abstract:
Neutron tagging in Gadolinium-doped water may play a significant role in reducing backgrounds from atmospheric neutrinos in next generation proton-decay searches using megaton-scale Water Cherenkov detectors. Similar techniques might also be useful in the detection of supernova neutrinos. Accurate determination of neutron tagging efficiencies will require a detailed understanding of the number of…
▽ More
Neutron tagging in Gadolinium-doped water may play a significant role in reducing backgrounds from atmospheric neutrinos in next generation proton-decay searches using megaton-scale Water Cherenkov detectors. Similar techniques might also be useful in the detection of supernova neutrinos. Accurate determination of neutron tagging efficiencies will require a detailed understanding of the number of neutrons produced by neutrino interactions in water as a function of momentum transferred. We propose the Atmospheric Neutrino Neutron Interaction Experiment (ANNIE), designed to measure the neutron yield of atmospheric neutrino interactions in gadolinium-doped water. An innovative aspect of the ANNIE design is the use of precision timing to localize interaction vertices in the small fiducial volume of the detector. We propose to achieve this by using early production of LAPPDs (Large Area Picosecond Photodetectors). This experiment will be a first application of these devices demonstrating their feasibility for Water Cherenkov neutrino detectors.
△ Less
Submitted 7 April, 2015;
originally announced April 2015.
-
Tests of a Novel Design of Resistive Plate Chambers
Authors:
B. Bilki,
F. Corriveau,
B. Freund,
C. Neubüser,
Y. Onel,
J. Repond,
J. Schlereth,
L. Xia
Abstract:
A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The tests confirmed the viability of this new approach. In addition to showing an improved single-particle response compared to the traditional 2-plate design, the…
▽ More
A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The tests confirmed the viability of this new approach. In addition to showing an improved single-particle response compared to the traditional 2-plate design, the novel chambers also prove to be suitable for calorimetric applications.
△ Less
Submitted 4 March, 2015; v1 submitted 22 January, 2015;
originally announced January 2015.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
Resistive Plate Chambers for Imaging Calorimetry - the DHCAL
Authors:
Jose Repond
Abstract:
The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Flow Algorithms (PFAs) to the reconstruction of hadronic jet energies in a colliding beam environment. The readout of the chambers is segmented into 1 x…
▽ More
The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Flow Algorithms (PFAs) to the reconstruction of hadronic jet energies in a colliding beam environment. The readout of the chambers is segmented into 1 x 1 cm2 pads, each read out with a 1-bit (single threshold) resolution. The prototype with approximately 500,000 readout channels underwent extensive testing in both the Fermilab and CERN test beams. This talk presents preliminary findings from the analysis of data collected at the test beams.
△ Less
Submitted 23 July, 2014; v1 submitted 28 April, 2014;
originally announced April 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Recent DHCAL Developments
Authors:
J. Repond
Abstract:
This talk reports on recent progress concerning the development of a Digital Hadron Calorimeter with Resistive Plate Chambers as active elements. After the successful testing of a Digital Hadron Calorimeter prototype, the DHCAL, in the Fermilab and CERN test beams, the DHCAL group is now tackling some of the remaining technical issues which were not addressed specifically with the prototype. The t…
▽ More
This talk reports on recent progress concerning the development of a Digital Hadron Calorimeter with Resistive Plate Chambers as active elements. After the successful testing of a Digital Hadron Calorimeter prototype, the DHCAL, in the Fermilab and CERN test beams, the DHCAL group is now tackling some of the remaining technical issues which were not addressed specifically with the prototype. The talk reports on developments related to the RPC chamber design, to improvements in the RPC rate capabilities, the high voltage distribution system, and a gas recirculation system.
△ Less
Submitted 13 December, 2013;
originally announced December 2013.
-
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Authors:
CALICE Collaboration,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon
, et al. (169 additional authors not shown)
Abstract:
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur…
▽ More
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
△ Less
Submitted 11 June, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.