-
The THESEUS space mission concept: science case, design and expected performances
Authors:
L. Amati,
P. O'Brien,
D. Goetz,
E. Bozzo,
C. Tenzer,
F. Frontera,
G. Ghirlanda,
C. Labanti,
J. P. Osborne,
G. Stratta,
N. Tanvir,
R. Willingale,
P. Attina,
R. Campana,
A. J. Castro-Tirado,
C. Contini,
F. Fuschino,
A. Gomboc,
R. Hudec,
P. Orleanski,
E. Renotte,
T. Rodic,
Z. Bagoly,
A. Blain,
P. Callanan
, et al. (187 additional authors not shown)
Abstract:
THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1sr) with 0.5-1 arcmin localization, an energ…
▽ More
THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1sr) with 0.5-1 arcmin localization, an energy band extending from several MeV down to 0.3 keV and high sensitivity to transient sources in the soft X-ray domain, as well as on-board prompt (few minutes) follow-up with a 0.7 m class IR telescope with both imaging and spectroscopic capabilities. THESEUS will be perfectly suited for addressing the main open issues in cosmology such as, e.g., star formation rate and metallicity evolution of the inter-stellar and intra-galactic medium up to redshift $\sim$10, signatures of Pop III stars, sources and physics of re-ionization, and the faint end of the galaxy luminosity function. In addition, it will provide unprecedented capability to monitor the X-ray variable sky, thus detecting, localizing, and identifying the electromagnetic counterparts to sources of gravitational radiation, which may be routinely detected in the late '20s / early '30s by next generation facilities like aLIGO/ aVirgo, eLISA, KAGRA, and Einstein Telescope. THESEUS will also provide powerful synergies with the next generation of multi-wavelength observatories (e.g., LSST, ELT, SKA, CTA, ATHENA).
△ Less
Submitted 27 March, 2018; v1 submitted 12 October, 2017;
originally announced October 2017.
-
The Athena X-ray Integral Field Unit (X-IFU)
Authors:
Didier Barret,
Thien Lam Trong,
Jan-Willem den Herder,
Luigi Piro,
Xavier Barcons,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Kazuhisa Mitsuda,
Stéphane Paltani,
Gregor Rauw,
Agata Rożanska,
Joern Wilms,
Marco Barbera,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Anne Decourchelle,
Roland den Hartog,
Jean-Marc Duval,
Fabrizio Fiore,
Flavio Gatti,
Andrea Goldwurm,
Brian Jackson,
Peter Jonker
, et al. (66 additional authors not shown)
Abstract:
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, d…
▽ More
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we briefly describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with further ESA member state contributions from Belgium, Finland, Germany, Poland, Spain, Switzerland and two international partners from the United States and Japan.
△ Less
Submitted 29 August, 2016;
originally announced August 2016.
-
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
Authors:
P. Bouchet,
M. Garcia-Marin,
P. -O. Lagage,
J. Amiaux,
J. -L. Augueres,
E. Bauwens,
J. A. D. L. Blommaert,
C. H. Chen,
O. H. Detre,
D. Dicken,
D. Dubreuil,
Ph. Galdemard,
R. Gastaud,
A. Glasse,
K. D. Gordon,
F. Gougnaud,
P. Guillard,
K. Justtanont,
O. Krause,
D. Leboeuf,
Y. Longval,
L. Martin,
E. Mazy,
V. Moreau,
G. Olofsson
, et al. (12 additional authors not shown)
Abstract:
In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and m…
▽ More
In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and mechanical design. We show that the test data, as measured during the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton Laboratory, and at the NASA Goddard Space Flight Center, indicate that the instrument complies with its design requirements and goals. We also discuss the operational requirements (multiple dithers and exposures) needed for optimal scientific utilization of the MIRIM.
△ Less
Submitted 11 August, 2015;
originally announced August 2015.
-
The Mid-Infrared Instrument for JWST, II: Design and Build
Authors:
G. S. Wright,
David Wright,
G. B. Goodson,
G. H. Rieke,
Gabby Aitink-Kroes,
J. Amiaux,
Ana Aricha-Yanguas,
Ruyman Azzolini,
Kimberly Banks,
D. Barrado-Navascues,
T. Belenguer-Davila,
J. A. D. L. Bloemmart,
Patrice Bouchet,
B. R. Brandl,
L. Colina,
Ors Detre,
Eva Diaz-Catala,
Paul Eccleston,
Scott D. Friedman,
Macarena Garcia-Marin,
Manuel Guedel,
Alistair Glasse,
Adrian M. Glauser,
T. P. Greene,
Uli Groezinger
, et al. (48 additional authors not shown)
Abstract:
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28.5 microns. MIRI has, within a single 'package', four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R ~ 100) spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field spectroscopy. An associate…
▽ More
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28.5 microns. MIRI has, within a single 'package', four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R ~ 100) spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field spectroscopy. An associated cooler system maintains MIRI at its operating temperature of < 6.7 K. This paper describes the driving principles behind the design of MIRI, the primary design parameters, and their realization in terms of the 'as-built' instrument. It also describes the test program that led to delivery of the tested and calibrated Flight Model to NASA in 2012, and the confirmation after delivery of the key interface requirements.
△ Less
Submitted 10 August, 2015;
originally announced August 2015.
-
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+
Authors:
D. Barret,
J. W. den Herder,
L. Piro,
L. Ravera,
R. Den Hartog,
C. Macculi,
X. Barcons,
M. Page,
S. Paltani,
G. Rauw,
J. Wilms,
M. Ceballos,
L. Duband,
L. Gottardi,
S. Lotti,
J. de Plaa,
E. Pointecouteau,
C. Schmid,
H. Akamatsu,
D. Bagliani,
S. Bandler,
M. Barbera,
P. Bastia,
M. Biasotti,
M. Branco
, et al. (33 additional authors not shown)
Abstract:
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane ins…
▽ More
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.
△ Less
Submitted 30 August, 2013;
originally announced August 2013.
-
Characterizing Exoplanets in the Visible and Infrared: A Spectrometer Concept for the EChO Space Mission
Authors:
A. M. Glauser,
R. van Boekel,
O. Krause,
Th. Henning,
B. Benneke,
J. Bouwman,
P. E. Cubillos,
I. J. M. Crossfield,
Ö. H. Detre,
M. Ebert,
U. Grözinger,
M. Güdel,
J. Harrington,
K. Justtanont,
U. Klaas,
R. Lenzen,
N. Madhusudhan,
M. R. Meyer,
C. Mordasini,
F. Müller,
R. Ottensamer,
J. -Y. Plesseria,
S. P. Quanz,
A. Reiners,
E. Renotte
, et al. (8 additional authors not shown)
Abstract:
Transit-spectroscopy of exoplanets is one of the key observational techniques to characterize the extrasolar planet and its atmosphere. The observational challenges of these measurements require dedicated instrumentation and only the space environment allows an undisturbed access to earth-like atmospheric features such as water or carbon-dioxide. Therefore, several exoplanet-specific space mission…
▽ More
Transit-spectroscopy of exoplanets is one of the key observational techniques to characterize the extrasolar planet and its atmosphere. The observational challenges of these measurements require dedicated instrumentation and only the space environment allows an undisturbed access to earth-like atmospheric features such as water or carbon-dioxide. Therefore, several exoplanet-specific space missions are currently being studied. One of them is EChO, the Exoplanet Characterization Observatory, which is part of ESA's Cosmic Vision 2015-2025 program, and which is one of four candidates for the M3 launch slot in 2024. In this paper we present the results of our assessment study of the EChO spectrometer, the only science instrument onboard this spacecraft. The instrument is a multi-channel all-reflective dispersive spectrometer, covering the wavelength range from 400 nm to 16 microns simultaneously with a moderately low spectral resolution. We illustrate how the key technical challenge of the EChO mission - the high photometric stability - influences the choice of spectrometer concept and drives fundamentally the instrument design. First performance evaluations underline the fitness of the elaborated design solution for the needs of the EChO mission.
△ Less
Submitted 14 May, 2013;
originally announced May 2013.
-
CHEOPS: A Transit Photometry Mission for ESA's Small Mission Programme
Authors:
C. Broeg,
A. Fortier,
D. Ehrenreich,
Y. Alibert,
W. Baumjohann,
W. Benz,
M. Deleuil,
M. Gillon,
A. Ivanov,
R. Liseau,
M. Meyer,
G. Oloffson,
I. Pagano,
G. Piotto,
D. Pollacco,
D. Queloz,
R. Ragazzoni,
E. Renotte,
M. Steller,
N. Thomas,
the CHEOPS team
Abstract:
Ground based radial velocity (RV) searches continue to discover exoplanets below Neptune mass down to Earth mass. Furthermore, ground based transit searches now reach milli-mag photometric precision and can discover Neptune size planets around bright stars. These searches will find exoplanets around bright stars anywhere on the sky, their discoveries representing prime science targets for further…
▽ More
Ground based radial velocity (RV) searches continue to discover exoplanets below Neptune mass down to Earth mass. Furthermore, ground based transit searches now reach milli-mag photometric precision and can discover Neptune size planets around bright stars. These searches will find exoplanets around bright stars anywhere on the sky, their discoveries representing prime science targets for further study due to the proximity and brightness of their host stars. A mission for transit follow-up measurements of these prime targets is currently lacking. The first ESA S-class mission CHEOPS (CHaracterizing ExoPlanet Satellite) will fill this gap. It will perform ultra-high precision photometric monitoring of selected bright target stars almost anywhere on the sky with sufficient precision to detect Earth sized transits. It will be able to detect transits of RV-planets by photometric monitoring if the geometric configuration results in a transit. For Hot Neptunes discovered from the ground, CHEOPS will be able to improve the transit light curve so that the radius can be determined precisely. Because of the host stars' brightness, high precision RV measurements will be possible for all targets. All planets observed in transit by CHEOPS will be validated and their masses will be known. This will provide valuable data for constraining the mass-radius relation of exoplanets, especially in the Neptune-mass regime. During the planned 3.5 year mission, about 500 targets will be observed. There will be 20% of open time available for the community to develop new science programmes.
△ Less
Submitted 10 May, 2013;
originally announced May 2013.
-
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
Authors:
A. Poglitsch,
C. Waelkens,
N. Geis,
H. Feuchtgruber,
B. Vandenbussche,
L. Rodriguez,
O. Krause,
E. Renotte,
C. van Hoof,
P. Saraceno,
J. Cepa,
F. Kerschbaum,
P. Agnese,
B. Ali,
B. Altieri,
P. Andreani,
J. -L. Augueres,
Z. Balog,
L. Barl,
O. H. Bauer,
N. Belbachir,
M. Benedettini,
N. Billot,
O. Boulade,
H. Bischof
, et al. (58 additional authors not shown)
Abstract:
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210…
▽ More
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210μ m wavelength regime. In photometry mode, it simultaneously images two bands, 60-85μ m or 85-125μ\m and 125-210μ m, over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47"x47", resolved into 5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral resolution of ~175km/s. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the Performance Verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions.
△ Less
Submitted 20 May, 2010; v1 submitted 10 May, 2010;
originally announced May 2010.