-
The Importance of Subcellular Structures to the Modeling of Biological Cells in the Context of Computational Bioelectromagnetics Simulations
Authors:
Kevin Jerbic,
Jan Taro Svejda,
Benedikt Sievert,
Andreas Rennings,
Jürg Fröhlich,
Daniel Erni
Abstract:
Numerical investigation of the interaction of electromagnetic fields with eukaryotic cells requires specifically adapted computer models. Virtual microdosimetry, used to investigate exposure, requires volumetric cell models, which are numerically challenging. For this reason, a method is presented here to determine the current and power densities occurring in single cells and their distinct compar…
▽ More
Numerical investigation of the interaction of electromagnetic fields with eukaryotic cells requires specifically adapted computer models. Virtual microdosimetry, used to investigate exposure, requires volumetric cell models, which are numerically challenging. For this reason, a method is presented here to determine the current and power densities occurring in single cells and their distinct compartments in a spatially accurate manner as a first step towards multicellular models within the microstructure of tissue layers. To achieve this, 3D models of the electromagnetic exposure of generic eukaryotic cells of different shape (i.e. spherical and ellipsoidal) and internal complexity (i.e. different organelles) are performed in a virtual, FEM-based capacitor experiment in the frequency range from 10 Hz to 100 GHz. In this context, the spectral response of the current and power distribution within the cell compartments is investigated and any effects that occur are attributed either to the dispersive material properties of these compartments or to the geometric characteristics of the cell model investigated in each case. In these investigations, the cell is represented as an anisotropic body with an internal distributed membrane system of low conductivity that mimics the endoplasmic reticulum in a simplified manner. This will be used to determine which details of the cell interior need to be modeled, how the electric field and the current density will be distributed in this region, and where the electromagnetic energy is absorbed in the microstructure regarding electromagnetic microdosimetry. Results show that for 5G frequencies, membranes make a significant contribution to the absorption losses.
△ Less
Submitted 17 April, 2023; v1 submitted 20 June, 2022;
originally announced June 2022.
-
Beam Divergence Reduction of Vortex Waves with a Tailored Lens and a Tailored Reflector
Authors:
M. Haj Hassan,
B. Sievert,
J. T. Svejda,
A. Mostafa Ahmad,
J. Barowski,
A. Rennings,
I. Rolfes,
A. Sezgin,
D. Erni
Abstract:
In this paper, we present a tailored lens and a tailored reflector in order to reduce the large beam divergence inherent to Orbital Angular Momentum waves (OAM waves-Vortex waves) that are generated by an Uniform Circular Patch Antenna Array (UCA) at 10 GHz. The tailored lens and the tailored reflector are designed by the shape function (5) and (9) around the antenna s center axis, respectively. T…
▽ More
In this paper, we present a tailored lens and a tailored reflector in order to reduce the large beam divergence inherent to Orbital Angular Momentum waves (OAM waves-Vortex waves) that are generated by an Uniform Circular Patch Antenna Array (UCA) at 10 GHz. The tailored lens and the tailored reflector are designed by the shape function (5) and (9) around the antenna s center axis, respectively. The tailored lens is compared to UCA without and with conventional lens. The simulated and measured results show a significant improvement when using the tailored lens. Following, a tailored reflector is implemented and compared to UCA without and with conventional reflector. Firstly, the two reflectors are simulated with an impressed field source to neglect the influence of the UCA. The simulated results of the two reflectors show that the tailored reflector has a better performance than the conventional reflector when the height of the reflector $r_0$ is less than around 1.5 $λ$ and when the opening angle of the reflector theta is less than 38° (for UCA with $d$ of $λ/2$). In addition, the reflectors are simulated with real UCA with different shapes of PCB, which can disturb the reflected waves from the reflector. Two lenses and two reflectors are manufactured and measured in an anechoic chamber and compared to the simulation results. This paper shows that the vortex waves needs a special lens or a special reflector to reduce effictively the beam divergence especially when the radius of the UCA is very large.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Limits of effective material properties in the context of an electromagnetic tissue model
Authors:
Kevin Jerbic,
Kevin Neumann,
Jan Taro Svejda,
Benedikt Sievert,
Andreas Rennings,
Daniel Erni
Abstract:
Most calibration schemes for reflection-based tissue spectroscopy in the mm-wave/THz-frequency range are based on homogenized, frequency-dependent tissue models where macroscopic material parameters have either been determined by measurement or calculated using effective material theory. However, as the resolution of measurement at these frequencies captures the underlying microstructure of the ti…
▽ More
Most calibration schemes for reflection-based tissue spectroscopy in the mm-wave/THz-frequency range are based on homogenized, frequency-dependent tissue models where macroscopic material parameters have either been determined by measurement or calculated using effective material theory. However, as the resolution of measurement at these frequencies captures the underlying microstructure of the tissue, here we will investigate the validity limits of such effective material models over a wide frequency range (10 MHz - 200 GHz) . Embedded in a parameterizable virtual workbench, we implemented a numerical homogenization method using a hierarchical multiscale approach to capture both the dispersive and tensorial electromagnetic properties of the tissue, and determined at which frequency this homogenized model deviated from a full-wave electromagnetic reference model within the framework of a Monte Carlo analysis. Simulations were carried out using a generic hypodermal tissue that emulated the morphology of the microstructure. Results showed that the validity limit occurred at surprisingly low frequencies and thus contradicted the traditional usage of homogenized tissue models. The reasons for this are explained in detail and thus it is shown how both the lower "allowed" and upper "forbidden" frequency ranges can be used for frequency-selective classification/identification of specific material and structural properties employing a supervised machine-learning approach. Using the implemented classifier, we developed a method to identify specific frequency bands in the forbidden frequency range to optimize the reliability of material classification.
△ Less
Submitted 28 December, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
A Self-Matched Leaky-Wave Antenna for Ultrahigh-Field MRI with Low SAR
Authors:
G. Solomakha,
J. T. Svejda,
C. van Leeuwen,
A. Rennings,
A. J. Raaijmakers,
S. Glybovski,
D. Erni
Abstract:
The technology of magnetic resonance imaging is develo** towards higher magnetic fields to improve resolution and contrast. However, whole-body imaging at 7 T or even higher fields remains challenging due to wave interference, tissue inhomogneities and high RF power deposition. Nowadays, proper RF excitation of a human body in prostate and cardiac MRI is only possible to achieve by using phased…
▽ More
The technology of magnetic resonance imaging is develo** towards higher magnetic fields to improve resolution and contrast. However, whole-body imaging at 7 T or even higher fields remains challenging due to wave interference, tissue inhomogneities and high RF power deposition. Nowadays, proper RF excitation of a human body in prostate and cardiac MRI is only possible to achieve by using phased arrays of antennas attached to the body (so-called surface coils). Due to safety concerns, the design of such coils aims to minimize the local specific absorption rate (SAR) kee** the highest possible RF signal in the region of interest. All previously demonstrated approaches were based on resonant structures such as e. g.dipoles, capacitively-loaded loops, TEM-line sections. In this study, we show that there is a better compromise between the transmit signal and the local SAR using non-resonant surface coils due to weaker RF near fields in the close proximity of their conductors. With this aim, we propose and experimentally demonstrate a first leaky-wave surface coil implemented as a periodically-slotted microstrip transmission line. Due to its non-resonant radiation, the proposed coil induces only slightly over half the peak local SAR compared to a state-of-the-art dipole coil, but has the same transmit efficiency in prostate imaging at 7 T. Unlike other coils, the leaky-wave coil intrinsically matches its input impedance to the averaged wave impedance of body tissues in a broad frequency range, which makes it very attractive for future clinical applications of 7 T MRI.
△ Less
Submitted 28 January, 2020;
originally announced January 2020.
-
Circular Polarization of Periodic Leaky-Wave Antennas with Axial Asymmetry: Theoretical Proof and Experimental Demonstration
Authors:
Simon Otto,
Zhichao Chen,
Amar Al-Bassam,
Andreas Rennings,
Klaus Solbach,
Christophe Caloz
Abstract:
The paper includes two contributions. First, it proves that the series and shunt radiation components, corresponding to longitudinal and transversal electric fields, respectively, are always in phase quadrature in axially asymmetric periodic leaky-wave antennas (LWAs), so that these antennas are inherently elliptically polarized. This fact is theoretically proven and experimentally illustrated by…
▽ More
The paper includes two contributions. First, it proves that the series and shunt radiation components, corresponding to longitudinal and transversal electric fields, respectively, are always in phase quadrature in axially asymmetric periodic leaky-wave antennas (LWAs), so that these antennas are inherently elliptically polarized. This fact is theoretically proven and experimentally illustrated by two case-study examples, a composite right/left-handed (CRLH) LWA and a series-fed patch (SFP) LWA. Second, it shows (for the case of the SFP LWA) that the axial ratio is controlled and minimized by the degree of axial asymmetry.
△ Less
Submitted 5 April, 2014; v1 submitted 30 June, 2013;
originally announced July 2013.