-
SN 2018ijp: the explosion of a stripped-envelope star within a dense H-rich shell?
Authors:
L. Tartaglia,
J. Sollerman,
C. Barbarino,
F. Taddia,
E. Mason,
M. Berton,
K. Taggart,
E. C. Bellm,
K. De,
S. Frederick,
C. Fremling,
A. Gal-Yam,
V. Z. Golkhou,
M. Graham,
A. Y. Q. Ho,
T. Hung,
S. Kaye,
Y. L. Kim,
R. R. Laher,
F. J. Masci,
D. A. Perley,
M. D. Porter,
D. J. Reiley,
R. Riddle,
B. Rusholme
, et al. (2 additional authors not shown)
Abstract:
In this paper, we discuss the outcomes of the follow-up campaign of SN 2018ijp, discovered as part of the Zwicky Transient Facility survey for optical transients. Its first spectrum shows similarities to broad-lined Type Ic supernovae around maximum light, whereas later spectra display strong signatures of interaction between rapidly expanding ejecta and a dense H-rich circumstellar medium, coinci…
▽ More
In this paper, we discuss the outcomes of the follow-up campaign of SN 2018ijp, discovered as part of the Zwicky Transient Facility survey for optical transients. Its first spectrum shows similarities to broad-lined Type Ic supernovae around maximum light, whereas later spectra display strong signatures of interaction between rapidly expanding ejecta and a dense H-rich circumstellar medium, coinciding with a second peak in the photometric evolution of the transient. This evolution, along with the results of modeling of the first light curve peak, suggests a scenario where a stripped star exploded within a dense circumstellar medium. The two main phases in the evolution of the transient could be interpreted as a first phase dominated by radioactive decays, and an later interaction-dominated phase where the ejecta collide with a pre-existing shell. We therefore discuss SN 2018jp within the context of a massive star depleted of its outer layers exploding within a dense H-rich circumstellar medium.
△ Less
Submitted 26 April, 2021; v1 submitted 7 September, 2020;
originally announced September 2020.
-
The Zwicky Transient Facility: Observing System
Authors:
Richard Dekany,
Roger M. Smith,
Reed Riddle,
Michael Feeney,
Michael Porter,
David Hale,
Jeffry Zolkower,
Justin Belicki,
Stephen Kaye,
John Henning,
Richard Walters,
John Cromer,
Alex Delacroix,
Hector Rodriguez,
Daniel J. Reiley,
Peter Mao,
David Hover,
Patrick Murphy,
Rick Burruss,
John Baker,
Marek Kowalski,
Klaus Reif,
Phillip Mueller,
Eric Bellm,
Matthew Graham
, et al. (1 additional authors not shown)
Abstract:
The Zwicky Transient Facility (ZTF) Observing System (OS) is the data collector for the ZTF project to study astrophysical phenomena in the time domain. ZTF OS is based upon the 48-inch aperture Schmidt-type design Samuel Oschin Telescope at the Palomar Observatory in Southern California. It incorporates new telescope aspheric corrector optics, dome and telescope drives, a large-format exposure sh…
▽ More
The Zwicky Transient Facility (ZTF) Observing System (OS) is the data collector for the ZTF project to study astrophysical phenomena in the time domain. ZTF OS is based upon the 48-inch aperture Schmidt-type design Samuel Oschin Telescope at the Palomar Observatory in Southern California. It incorporates new telescope aspheric corrector optics, dome and telescope drives, a large-format exposure shutter, a flat-field illumination system, a robotic bandpass filter exchanger, and the key element: a new 47-square-degree, 600 megapixel cryogenic CCD mosaic science camera, along with supporting equipment. The OS collects and delivers digitized survey data to the ZTF Data System (DS). Here, we describe the ZTF OS design, optical implementation, delivered image quality, detector performance, and robotic survey efficiency.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
A non-equipartition shockwave traveling in a dense circumstellar environment around SN2020oi
Authors:
Assaf Horesh,
Itai Sfaradi,
Mattias Ergon,
Cristina Barbarino,
Jesper Sollerman,
Javier Moldon,
Dougal Dobie,
Steve Schulze,
Miguel Perez-Torres,
David R. A. Williams,
Christoffer Fremling,
Avishay Gal-Yam,
Shrinivas R. Kulkarni,
Andrew O'Brien,
Peter Lundqvist,
Tara Murphy,
Rob Fender,
Justin Belicki,
Eric C. Bellm,
Michael W. Coughlin,
Eran O. Ofek,
V. Zach Golkhou,
Matthew J. Graham,
Dave A. Green,
Thomas Kupfer
, et al. (12 additional authors not shown)
Abstract:
We report the discovery and panchromatic followup observations of the young Type Ic supernova, SN2020oi, in M100, a grand design spiral galaxy at a mere distance of $14$ Mpc. We followed up with observations at radio, X-ray and optical wavelengths from only a few days to several months after explosion. The optical behaviour of the supernova is similar to those of other normal Type Ic supernovae. T…
▽ More
We report the discovery and panchromatic followup observations of the young Type Ic supernova, SN2020oi, in M100, a grand design spiral galaxy at a mere distance of $14$ Mpc. We followed up with observations at radio, X-ray and optical wavelengths from only a few days to several months after explosion. The optical behaviour of the supernova is similar to those of other normal Type Ic supernovae. The event was not detected in the X-ray band but our radio observation revealed a bright mJy source ($L_ν \approx 1.2 \times 10^{27} {\rm erg\,s}^{-1} {\rm Hz}^{-1}$). Given, the relatively small number of stripped envelope SNe for which radio emission is detectable, we used this opportunity to perform a detailed analysis of the comprehensive radio dataset we obtained. The radio emitting electrons initially experience a phase of inverse Compton cooling which leads to steepening of the spectral index of the radio emission. Our analysis of the cooling frequency points to a large deviation from equipartition at the level of $ε_e/ε_B \gtrsim 200$, similar to a few other cases of stripped envelope SNe. Our modeling of the radio data suggests that the shockwave driven by the SN ejecta into the circumstellar matter (CSM) is moving at $\sim 3\times 10^{4}\,{\rm km\,s}^{-1}$. Assuming a constant mass-loss from the stellar progenitor, we find that the mass-loss rate is $\dot{M} \approx 1.4\times 10^{-4}\,{M}_{\odot}\,{\rm yr}^{-1}$, for an assumed wind velocity of $1000\,{\rm km\,s}^{-1}$. The temporal evolution of the radio emission suggests a radial CSM density structure steeper than the standard $r^{-2}$.
△ Less
Submitted 24 June, 2020;
originally announced June 2020.
-
A Twilight Search for Atiras, Vatiras and Co-orbital Asteroids: Preliminary Results
Authors:
Quanzhi Ye,
Frank J. Masci,
Wing-Huen Ip,
Thomas A. Prince,
George Helou,
Davide Farnocchia,
Eric C. Bellm,
Richard Dekany,
Matthew J. Graham,
Shrinivas R. Kulkarni,
Thomas Kupfer,
Ashish Mahabal,
Chow-Choong Ngeow,
Daniel J. Reiley,
Maayane T. Soumagnac
Abstract:
Near-Earth Objects (NEOs) that orbit the Sun on or within Earth's orbit are tricky to detect for Earth-based observers due to their proximity to the Sun in the sky. These small bodies hold clues to the dynamical history of the inner solar system as well as the physical evolution of planetesimals in extreme environments. Populations in this region include the Atira and Vatira asteroids, as well as…
▽ More
Near-Earth Objects (NEOs) that orbit the Sun on or within Earth's orbit are tricky to detect for Earth-based observers due to their proximity to the Sun in the sky. These small bodies hold clues to the dynamical history of the inner solar system as well as the physical evolution of planetesimals in extreme environments. Populations in this region include the Atira and Vatira asteroids, as well as Venus and Earth co-orbital asteroids. Here we present a twilight search for these small bodies, conducted using the 1.2-m Oschin Schmidt and the Zwicky Transient Facility (ZTF) camera at Palomar Observatory. The ZTF twilight survey operates at solar elongations down to $35^\circ$ with limiting magnitude of $r=19.5$. During a total of 40 evening sessions and 62 morning sessions conducted between 2018 November 15 and 2019 June 23, we detected 6 Atiras, including 2 new discoveries 2019 AQ$_3$ and 2019 LF$_6$, but no Vatiras or Earth/Venus co-orbital asteroids. NEO population models show that these new discoveries are likely only the tip of the iceberg, with the bulk of the population yet to be found. The population models also suggest that we have only detected 5--$7\%$ of the $H<20$ Atira population over the 7-month survey. Co-orbital asteroids are smaller in diameters and require deeper surveys. A systematic and efficient survey of the near-Sun region will require deeper searches and/or facilities that can operate at small solar elongations.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives
Authors:
Naoyuki Tamura,
Naruhisa Takato,
Atsushi Shimono,
Yuki Moritani,
Kiyoto Yabe,
Yuki Ishizuka,
Akitoshi Ueda,
Yukiko Kamata,
Hrand Aghazarian,
Stephane Arnouts,
Gabriel Barban,
Robert H. Barkhouser,
Renato C. Borges,
David F. Braun,
Michael A. Carr,
Pierre-Yves Chabaud,
Yin-Chang Chang,
Hsin-Yo Chen,
Masashi Chiba,
Richard C. Y. Chou,
You-Hua Chu,
Judith G. Cohen,
Rodrigo P. de Almeida,
Antonio C. de Oliveira,
Ligia S. de Oliveira
, et al. (75 additional authors not shown)
Abstract:
PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simult…
▽ More
PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is develo** this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
△ Less
Submitted 3 August, 2016;
originally announced August 2016.
-
Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope
Authors:
Shiang-Yu Wang,
Richard C. Y. Chou,
Pin-Jie Huang,
Hung-Hsu Ling,
Jennifer Karr,
Yin-Chang Chang,
Yen-Shan Hu,
Shu-Fu Hsu,
Hsin-Yo Chen,
James E. Gunn,
Dan J. Reiley,
Naoyuki Tamura,
Naruhisa Takato,
Atsushi Shimono
Abstract:
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less t…
▽ More
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less than 10um. The metrology camera system (MCS) serves as the optical encoder of the fiber motors for the configuring of fibers. MCS provides the fiber positions within a 5um error over the 45 cm focal plane. The information from MCS will be fed into the fiber positioner control system for the closed loop control. MCS will be located at the Cassegrain focus of Subaru telescope in order to to cover the whole focal plane with one 50M pixel Canon CMOS camera. It is a 380mm Schmidt type telescope which generates a uniform spot size with a 10 micron FWHM across the field for reasonable sampling of PSF. Carbon fiber tubes are used to provide a stable structure over the operating conditions without focus adjustments. The CMOS sensor can be read in 0.8s to reduce the overhead for the fiber configuration. The positions of all fibers can be obtained within 0.5s after the readout of the frame. This enables the overall fiber configuration to be less than 2 minutes. MCS will be installed inside a standard Subaru Cassgrain Box. All components that generate heat are located inside a glycol cooled cabinet to reduce the possible image motion due to heat. The optics and camera for MCS have been delivered and tested. The mechanical parts and supporting structure are ready as of spring 2016. The integration of MCS will start in the summer of 2016.
△ Less
Submitted 1 August, 2016;
originally announced August 2016.
-
The Current Status of Prime Focus Instrument of Subaru Prime Focus Spectrograph
Authors:
Shiang-Yu Wang,
Mark A. Schwochert,
Pin-Jie Huang,
Hsin-Yo Chen,
Masahiko Kimura,
Richard C. Y. Chou,
Yin-Chang Chang,
Yen-Sang Hu,
Hung-Hsu Ling,
Chaz N. Morantz,
Dan J. Reiley,
Peter Mao,
David F. Braun,
Chih-Yi Wen,
Chi-Hung Yan,
Jennifer Karr,
James E. Gunn,
Graham Murray,
Naoyuki Tamura,
Naruhisa Takato,
Atsushi Shimono,
Decio Ferreira,
Leandro Henriqu dos Santosh,
Ligia Souza Oliveira,
Antonio Cesar de Oliveira
, et al. (1 additional authors not shown)
Abstract:
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope…
▽ More
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding cameras (AGCs), the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC's Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy. In this report, the latest status of PFI development will be given including the performance of PFI components, the setup and performance of the integration and testing equipment.
△ Less
Submitted 1 August, 2016;
originally announced August 2016.
-
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph
Authors:
Hajime Sugai,
Naoyuki Tamura,
Hiroshi Karoji,
Atsushi Shimono,
Naruhisa Takato,
Masahiko Kimura,
Youichi Ohyama,
Akitoshi Ueda,
Hrand Aghazarian,
Marcio Vital de Arruda,
Robert H. Barkhouser,
Charles L. Bennett,
Steve Bickerton,
Alexandre Bozier,
David F. Braun,
Khanh Bui,
Christopher M. Capocasale,
Michael A. Carr,
Bruno Castilho,
Yin-Chang Chang,
Hsin-Yo Chen,
Richard C. Y. Chou,
Olivia R. Dawson,
Richard G. Dekany,
Eric M. Ek
, et al. (59 additional authors not shown)
Abstract:
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 μm to 1.26 μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy…
▽ More
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 μm to 1.26 μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 μm to 0.89 μm will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.
△ Less
Submitted 2 July, 2015;
originally announced July 2015.
-
Studying focal ratio degradation of optical fibers for Subaru Prime Focus Spectrograph
Authors:
Jesulino Bispo dos Santos,
Antonio Cesar de Oliveira,
James Gunn,
Ligia Souza de Oliveira,
Marcio Vital de Arruda,
Bruno Castilho,
Clemens Darvin Gneiding,
Flavio Felipe Ribeiro,
Graham Murray,
Daniel J. Reiley,
Laerte Sodré Junior,
Claudia Mendes de Oliveira
Abstract:
Focal Ration Degradation (FRD) is a change in light angular distribution caused by fiber optics. FRD is important to fiber-fed, spectroscopic astronomical systems because it can cause loss of signal, degradation in spectral resolution, or increased complexity in spectrograph design. Laboratório Nacional de Astrofísica (LNA) has developed a system that can accurately and precisely measures FRD, usi…
▽ More
Focal Ration Degradation (FRD) is a change in light angular distribution caused by fiber optics. FRD is important to fiber-fed, spectroscopic astronomical systems because it can cause loss of signal, degradation in spectral resolution, or increased complexity in spectrograph design. Laboratório Nacional de Astrofísica (LNA) has developed a system that can accurately and precisely measures FRD, using an absolute method that can also measure fiber throughput. This paper describes the metrology system and shows measurements of Polymicro fiber FBP129168190, FBP127165190 and Fujikura fiber 128170190. Although the FRD of the two fibers are low and similar to one another, it is very important to know the exact characteristics of these fibers since both will be used in the construction of FOCCoS (Fiber Optical Cable and Connectors System) for PFS (Prime Focus Spectrograph) to be installed at the Subaru telescope.
△ Less
Submitted 13 August, 2014;
originally announced August 2014.
-
Prime Focus Instrument of Prime Focus Spectrograph for Subaru Telescope
Authors:
Shiang-Yu Wang,
David F. Braun,
Mark A. Schwochert,
Pin-Jie Huang,
Masahiko Kimura,
Hsin-Yo Chen,
Dan J. Reiley,
Peter Mao,
Charles D. Fisher,
Naoyuki Tamura,
Yin-Chang Chang,
Yen-Sang Hu,
Hung-Hsu Ling,
Chih-Yi Wen,
Richard C. -Y. Chou,
Naruhisa Takato,
Hajime Sugai,
Youichi Ohyama,
Hiroshi Karoji,
Atsushi Shimono,
Akitoshi Ueda
Abstract:
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope…
▽ More
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding (A&G) cameras, the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru
Authors:
Antonio Cesar de Oliveira,
Lígia Souza de Oliveira,
Márcio V. de Arruda,
Lucas Souza Marrara,
Leandro H. dos Santos,
Décio Ferreira,
Jesulino B. dos Santos,
Josimar A. Rosa,
Orlando V. Junior,
Jeferson M. Pereira,
Bruno Castilho,
Clemens Gneiding,
Laerte S. Junior,
Claudia M. de Oliveira,
James E. Gunn,
Akitoshi Ueda,
Naruhisa Takato,
Atsushi Shimono,
Hajime Sugai,
Hiroshi Karoji,
Masahiko Kimura,
Naoyuki Tamura,
Shiang-Yu Wang,
Graham Murray,
David Le Mignant
, et al. (7 additional authors not shown)
Abstract:
FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi…
▽ More
FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph
Authors:
Hajime Sugai,
Naoyuki Tamura,
Hiroshi Karoji,
Atsushi Shimono,
Naruhisa Takato,
Masahiko Kimura,
Youichi Ohyama,
Akitoshi Ueda,
Hrand Aghazarian,
Marcio Vital de Arruda,
Robert H. Barkhouser,
Charles L. Bennett,
Steve Bickerton,
Alexandre Bozier,
David F. Braun,
Khanh Bui,
Christopher M. Capocasale,
Michael A. Carr,
Bruno Castilho,
Yin-Chang Chang,
Hsin-Yo Chen,
Richard C. Y. Chou,
Olivia R. Dawson,
Richard G. Dekany,
Eric M. Ek
, et al. (59 additional authors not shown)
Abstract:
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology,…
▽ More
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.