-
Optimizing Variable Flip-Angles in Magnetization-Prepared Gradient Echo Sequences for Efficient 3D-T1rho Map**
Authors:
Marcelo V W Zibetti,
Hector L. De Moura,
Mahesh B. Keerthivasan,
Ravinder R Regatte
Abstract:
Purpose: To optimize the choice of the flip-angles of magnetization-prepared gradient echo (MP-GRE) sequences for improved accuracy, precision, and speed of 3D-T1rho map**. Methods: We propose a new optimization approach for finding variable flip-angle (VFA) values that improve MP-GRE sequences used for 3D-T1\r{ho} map**. This new approach can simultaneously improve the accuracy and signal-to-…
▽ More
Purpose: To optimize the choice of the flip-angles of magnetization-prepared gradient echo (MP-GRE) sequences for improved accuracy, precision, and speed of 3D-T1rho map**. Methods: We propose a new optimization approach for finding variable flip-angle (VFA) values that improve MP-GRE sequences used for 3D-T1\r{ho} map**. This new approach can simultaneously improve the accuracy and signal-to-noise ratio (SNR) while reducing filtering effects. We demonstrate the concept in the three different versions of the MP-GRE sequences that are typically used for 3D-T1rho map** and evaluate their performance in model agarose phantoms (n=6) and healthy volunteers (n=5) for knee joint imaging. We also tested the optimization with sequence parameters targeting faster acquisitions. Results: Our results show that optimized VFA can improve the accuracy and the precision of the sequences, seen as a reduction of the mean of normalized absolute difference (MNAD) from 6~8% to 4~5% in model phantoms and from 14~22% to 12~14% in the knee joint, and improving SNR from 12~27 to 24~35 in agarose phantoms and 5~13 to 11~16 in healthy volunteers. The optimization can also compensate for the loss in quality caused by making the sequence faster. This results in sequence configurations that acquire nearly twice more data per unit of time with similar SNR and MNAD measurements as compared to its slower versions. Conclusion: The optimization of the VFA can be used to increase accuracy and precision, and improve the speed of the typical imaging sequences used for quantitative 3D-T1rho map** of the knee joint.
△ Less
Submitted 16 November, 2022;
originally announced November 2022.
-
Alternating Learning Approach for Variational Networks and Undersampling Pattern in Parallel MRI Applications
Authors:
Marcelo V. W. Zibetti,
Florian Knoll,
Ravinder R. Regatte
Abstract:
Purpose: To propose an alternating learning approach to learn the sampling pattern (SP) and the parameters of variational networks (VN) in accelerated parallel magnetic resonance imaging (MRI). Methods: The approach alternates between improving the SP, using bias-accelerated subset selection, and improving parameters of the VN, using ADAM with monotonicity verification. The algorithm learns an eff…
▽ More
Purpose: To propose an alternating learning approach to learn the sampling pattern (SP) and the parameters of variational networks (VN) in accelerated parallel magnetic resonance imaging (MRI). Methods: The approach alternates between improving the SP, using bias-accelerated subset selection, and improving parameters of the VN, using ADAM with monotonicity verification. The algorithm learns an effective pair: an SP that captures fewer k-space samples generating undersampling artifacts that are removed by the VN reconstruction. The proposed approach was tested for stability and convergence, considering different initial SPs. The quality of the VNs and SPs was compared against other approaches, including joint learning methods and VN learning with fixed variable density Poisson-disc SPs, using two different datasets and different acceleration factors (AF). Results: The root mean squared error (RMSE) improvements ranged from 14.9% to 51.2% considering AF from 2 to 20 in the tested brain and knee joint datasets when compared to the other approaches. The proposed approach has shown stable convergence, obtaining similar SPs with the same RMSE under different initial conditions. Conclusion: The proposed approach was stable and learned effective SPs with the corresponding VN parameters that produce images with better quality than other approaches, improving accelerated parallel MRI applications.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
Fast Data-Driven Learning of MRI Sampling Pattern for Large Scale Problems
Authors:
Marcelo V. W. Zibetti,
Gabor T. Herman,
Ravinder R. Regatte
Abstract:
Purpose: A fast data-driven optimization approach, named bias-accelerated subset selection (BASS), is proposed for learning efficacious sampling patterns (SPs) with the purpose of reducing scan time in large-dimensional parallel MRI. Methods: BASS is applicable when Cartesian fully-sampled k-space data of specific anatomy is available for training and the reconstruction method is specified, learni…
▽ More
Purpose: A fast data-driven optimization approach, named bias-accelerated subset selection (BASS), is proposed for learning efficacious sampling patterns (SPs) with the purpose of reducing scan time in large-dimensional parallel MRI. Methods: BASS is applicable when Cartesian fully-sampled k-space data of specific anatomy is available for training and the reconstruction method is specified, learning which k-space points are more relevant for the specific anatomy and reconstruction in recovering the non-sampled points. BASS was tested with four reconstruction methods for parallel MRI based on low-rankness and sparsity that allow a free choice of the SP. Two datasets were tested, one of the brain images for high-resolution imaging and another of knee images for quantitative map** of the cartilage. Results: BASS, with its low computational cost and fast convergence, obtained SPs 100 times faster than the current best greedy approaches. Reconstruction quality increased up to 45\% with our learned SP over that provided by variable density and Poisson disk SPs, considering the same scan time. Optionally, the scan time can be nearly halved without loss of reconstruction quality. Conclusion: Compared with current approaches, BASS can be used to rapidly learn effective SPs for various reconstruction methods, using larger SP and larger datasets. This enables a better selection of efficacious sampling-reconstruction pairs for specific MRI problems.
△ Less
Submitted 4 November, 2020;
originally announced November 2020.
-
The International Workshop on Osteoarthritis Imaging Knee MRI Segmentation Challenge: A Multi-Institute Evaluation and Analysis Framework on a Standardized Dataset
Authors:
Arjun D. Desai,
Francesco Caliva,
Claudia Iriondo,
Naji Khosravan,
Aliasghar Mortazi,
Sachin Jambawalikar,
Drew Torigian,
Jutta Ellermann,
Mehmet Akcakaya,
Ulas Bagci,
Radhika Tibrewala,
Io Flament,
Matthew O`Brien,
Sharmila Majumdar,
Mathias Perslev,
Akshay Pai,
Christian Igel,
Erik B. Dam,
Sibaji Gaj,
Mingrui Yang,
Kunio Nakamura,
Xiaojuan Li,
Cem M. Deniz,
Vladimir Juras,
Ravinder Regatte
, et al. (4 additional authors not shown)
Abstract:
Purpose: To organize a knee MRI segmentation challenge for characterizing the semantic and clinical efficacy of automatic segmentation methods relevant for monitoring osteoarthritis progression.
Methods: A dataset partition consisting of 3D knee MRI from 88 subjects at two timepoints with ground-truth articular (femoral, tibial, patellar) cartilage and meniscus segmentations was standardized. Ch…
▽ More
Purpose: To organize a knee MRI segmentation challenge for characterizing the semantic and clinical efficacy of automatic segmentation methods relevant for monitoring osteoarthritis progression.
Methods: A dataset partition consisting of 3D knee MRI from 88 subjects at two timepoints with ground-truth articular (femoral, tibial, patellar) cartilage and meniscus segmentations was standardized. Challenge submissions and a majority-vote ensemble were evaluated using Dice score, average symmetric surface distance, volumetric overlap error, and coefficient of variation on a hold-out test set. Similarities in network segmentations were evaluated using pairwise Dice correlations. Articular cartilage thickness was computed per-scan and longitudinally. Correlation between thickness error and segmentation metrics was measured using Pearson's coefficient. Two empirical upper bounds for ensemble performance were computed using combinations of model outputs that consolidated true positives and true negatives.
Results: Six teams (T1-T6) submitted entries for the challenge. No significant differences were observed across all segmentation metrics for all tissues (p=1.0) among the four top-performing networks (T2, T3, T4, T6). Dice correlations between network pairs were high (>0.85). Per-scan thickness errors were negligible among T1-T4 (p=0.99) and longitudinal changes showed minimal bias (<0.03mm). Low correlations (<0.41) were observed between segmentation metrics and thickness error. The majority-vote ensemble was comparable to top performing networks (p=1.0). Empirical upper bound performances were similar for both combinations (p=1.0).
Conclusion: Diverse networks learned to segment the knee similarly where high segmentation accuracy did not correlate to cartilage thickness accuracy. Voting ensembles did not outperform individual networks but may help regularize individual models.
△ Less
Submitted 26 May, 2020; v1 submitted 29 April, 2020;
originally announced April 2020.
-
The Discrete Fourier Transform for Golden Angle Linogram Sampling
Authors:
Elias S. Helou,
Marcelo V. W. Zibetti,
Leon Axel,
Kai Tobias Block,
Ravinder R. Regatte,
Gabor T. Herman
Abstract:
Estimation of the Discrete-Time Fourier Transform (DTFT) at points of a finite domain arises in many imaging applications. A new approach to this task, the Golden Angle Linogram Fourier Domain (GALFD), is presented, together with a computationally fast and accurate tool, named Golden Angle Linogram Evaluation (GALE), for approximating the DTFT at points of a GALFD. A GALFD resembles a Linogram Fou…
▽ More
Estimation of the Discrete-Time Fourier Transform (DTFT) at points of a finite domain arises in many imaging applications. A new approach to this task, the Golden Angle Linogram Fourier Domain (GALFD), is presented, together with a computationally fast and accurate tool, named Golden Angle Linogram Evaluation (GALE), for approximating the DTFT at points of a GALFD. A GALFD resembles a Linogram Fourier Domain (LFD), which is efficient and accurate. A limitation of linograms is that embedding an LFD into a larger one requires many extra points, at least doubling the domain's cardinality. The GALFD, on the other hand, allows for incremental inclusion of relatively few data points. Approximation error bounds and floating point operations counts are presented to show that GALE computes accurately and efficiently the DTFT at the points of a GALFD. The ability to extend the data collection in small increments is beneficial in applications such as Magnetic Resonance Imaging. Experiments for simulated and for real-world data are presented to substantiate the theoretical claims. The mathematical analysis, algorithms, and software developed in the paper are equally suitable to other angular distributions of rays and therefore we bring the benefits of linograms to arbitrary radial patterns.
△ Less
Submitted 6 September, 2019; v1 submitted 1 April, 2019;
originally announced April 2019.