-
Active deployable primary mirrors on CubeSat
Authors:
Noah Schwartz,
Maria Milanova,
William Brzozowski,
Stephen Todd,
Zeshan Ali,
Lucie Buron,
Jean-François-Sauvage,
Charlotte Bond,
Heather Bruce,
Phil Rees,
Marc Ferrari,
Donald MacLeod
Abstract:
The volume available on small satellites restricts the size of optical apertures to a few centimetres, limiting the Ground-Sampling Distance (GSD) in the visible to typically 3 m at 500 km. We present in this paper the latest development of a laboratory demonstrator of a segmented deployable telescope that will triple the achievable ground resolution and improve photometric capability of CubeSat i…
▽ More
The volume available on small satellites restricts the size of optical apertures to a few centimetres, limiting the Ground-Sampling Distance (GSD) in the visible to typically 3 m at 500 km. We present in this paper the latest development of a laboratory demonstrator of a segmented deployable telescope that will triple the achievable ground resolution and improve photometric capability of CubeSat imagers. Each mirror segment is folded for launch and unfolds in space. We demonstrate through laboratory validation very high deployment repeatability of the mirrors <{\pm}5 μm. To enable diffraction-limited imaging, segments are controlled in piston, tip, and tilt. This is achieved by an initial coarse alignment of the mirrors followed by a fine phasing step. Finally, we investigate the impact of the thermal environment on high-order wavefront error and the conceptual design of a deployable secondary fitting inside 1U.
△ Less
Submitted 26 May, 2021;
originally announced May 2021.
-
HIRES, the high-resolution spectrograph for the ELT
Authors:
Alessandro Marconi,
Manuel Abreu,
Vardan Adibekyan,
Matteo Aliverti,
Carlos Allende Prieto,
Pedro J. Amado,
Manuel Amate,
Etienne Artigau,
Sergio R. Augusto,
Susana Barros,
Santiago Becerril,
Bjorn Benneke,
Edwin Bergin,
Philippe Berio,
Naidu Bezawada,
Isabelle Boisse,
Xavier Bonfils,
Francois Bouchy,
Christopher Broeg,
Alexandre Cabral,
Rocio Calvo-Ortega,
Bruno Leonardo Canto Martins,
Bruno Chazelas,
Andrea Chiavassa,
Lise B. Christensen
, et al. (77 additional authors not shown)
Abstract:
HIRES will be the high-resolution spectrograph of the European Extremely Large Telescope at optical and near-infrared wavelengths. It consists of three fibre-fed spectrographs providing a wavelength coverage of 0.4-1.8 mic (goal 0.35-1.8 mic) at a spectral resolution of ~100,000. The fibre-feeding allows HIRES to have several, interchangeable observing modes including a SCAO module and a small dif…
▽ More
HIRES will be the high-resolution spectrograph of the European Extremely Large Telescope at optical and near-infrared wavelengths. It consists of three fibre-fed spectrographs providing a wavelength coverage of 0.4-1.8 mic (goal 0.35-1.8 mic) at a spectral resolution of ~100,000. The fibre-feeding allows HIRES to have several, interchangeable observing modes including a SCAO module and a small diffraction-limited IFU in the NIR. Therefore, it will be able to operate both in seeing and diffraction-limited modes. ELT-HIRES has a wide range of science cases spanning nearly all areas of research in astrophysics and even fundamental physics. Some of the top science cases will be the detection of bio signatures from exoplanet atmospheres, finding the fingerprints of the first generation of stars (PopIII), tests on the stability of Nature's fundamental couplings, and the direct detection of the cosmic acceleration. The HIRES consortium is composed of more than 30 institutes from 14 countries, forming a team of more than 200 scientists and engineers.
△ Less
Submitted 24 November, 2020;
originally announced November 2020.
-
Bilayer graphene nanoribbons junction with aligned holes exhibiting high ZT values
Authors:
Shuo Deng,
Lijie Li,
Paul Rees
Abstract:
We investigate the thermoelectric performance of armchair graphene nanoribbon (AGNR), bilayer GNRs junction (BGNRJ) and BGNRJ with holes (BGNRJ-H) by the first principles calculation with non-equilibrium Green function. It is found that the BGNRJ-H exhibits high ZT values of 9.65 and 5.55 at 300K. The reason of these significantly larger ZT values than previously observed has been calculated due t…
▽ More
We investigate the thermoelectric performance of armchair graphene nanoribbon (AGNR), bilayer GNRs junction (BGNRJ) and BGNRJ with holes (BGNRJ-H) by the first principles calculation with non-equilibrium Green function. It is found that the BGNRJ-H exhibits high ZT values of 9.65 and 5.55 at 300K. The reason of these significantly larger ZT values than previously observed has been calculated due to reduced thermal conductivity and enhanced electrical conductivity. The low thermal conductance comes from the van der waals (vdW) interaction between two graphene layers. The increased electrical conductivity can be attributed to the coupling effect of aligned holes in both layers. It is found from analysis results that the electron transmission of the BGNRJ-H is much stronger than a normal BGNRJ, which gives rise to the higher electrical conductance and outstanding ZT values.
△ Less
Submitted 5 September, 2019; v1 submitted 25 May, 2019;
originally announced May 2019.
-
Reconstruction of a conic-section surface from autocollimator-based deflectometric profilometry
Authors:
Samantha J. Thompson,
Richard Lang,
Paul Rees,
Gareth W. Roberts
Abstract:
We present a description of our method to process a set of autocollimator-based deflectometer 1-dimensional line-scans taken over a large optical surface and reconstruct them to a best-fit conic-section surface. The challenge with our task is that each line-scan is in a different (unknown) coordinate reference frame with respect to the other line-scans in the set. This problem arises due to the li…
▽ More
We present a description of our method to process a set of autocollimator-based deflectometer 1-dimensional line-scans taken over a large optical surface and reconstruct them to a best-fit conic-section surface. The challenge with our task is that each line-scan is in a different (unknown) coordinate reference frame with respect to the other line-scans in the set. This problem arises due to the limited angular measurement range of the autocollimator used in the deflectometer and the need to measure over a greater range; this results in the optic under measurement being rotated (in pitch and roll) between each scan to bring the autocollimator back into measurement range and therefore each scan is taken in a different coordinate frame. We describe an approach using a 6N+2 dimension optimisation (where N is the number of scan lines taken across the mirror) that uses a gradient-based non-linear least squares fitting combined with a multi-start global search strategy to find the best-fit surface. Careful formulation of the problem is required to reduce numerical noise and allow the routine to converge on a solution of the required accuracy.
△ Less
Submitted 27 April, 2016;
originally announced April 2016.
-
Updated optical design and trade-off study for MOONS, the Multi-Object Optical and Near Infrared spectrometer for the VLT
Authors:
E. Oliva,
S. Todd,
M. Cirasuolo,
H. Schnetler,
D. Lunney,
P. Rees,
A. Bianco,
E. Diolaiti,
D. Ferruzzi,
M. Fisher,
I. Guinouard,
M. Iuzzolino,
I. Parry,
X. Sun,
A. Tozzi,
F. Vitali
Abstract:
This paper presents the latest optical design for the MOONS triple-arm spectrographs. MOONS will be a Multi-Object Optical and Near-infrared Spectrograph and will be installed on one of the European Southern Observatory (ESO) Very Large Telescopes (VLT). Included in this paper is a trade-off analysis of different types of collimators, cameras, dichroics and filters.
This paper presents the latest optical design for the MOONS triple-arm spectrographs. MOONS will be a Multi-Object Optical and Near-infrared Spectrograph and will be installed on one of the European Southern Observatory (ESO) Very Large Telescopes (VLT). Included in this paper is a trade-off analysis of different types of collimators, cameras, dichroics and filters.
△ Less
Submitted 11 July, 2014;
originally announced July 2014.
-
HARP/ACSIS: A submillimetre spectral imaging system on the James Clerk Maxwell Telescope
Authors:
J. V. Buckle,
R. E. Hills,
H. Smith,
W. R. F. Dent,
G. Bell,
E. I. Curtis,
R. Dace,
H. Gibson,
S. F. Graves,
J. Leech,
J. S. Richer,
R. Williamson,
S. Withington,
G. Yassin,
R. Bennett,
P. Hastings,
I. Laidlaw,
J. F. Lightfoot,
T. Burgess,
P. E. Dewdney,
G. Hovey,
A. G. Willis,
R. Redman,
B. Wooff,
D. S. Berry
, et al. (13 additional authors not shown)
Abstract:
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) map** speeds, along with significant improvements…
▽ More
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) map** speeds, along with significant improvements over single-detector counterparts in calibration and image quality. Receiver temperatures are $\sim$120 K across the whole band and system temperatures of $\sim$300K are reached routinely under good weather conditions. The system includes a single-sideband filter so these are SSB figures. Used in conjunction with ACSIS, the system can produce large-scale maps rapidly, in one or more frequency settings, at high spatial and spectral resolution. Fully-sampled maps of size 1 square degree can be observed in under 1 hour.
The scientific need for array receivers arises from the requirement for programmes to study samples of objects of statistically significant size, in large-scale unbiased surveys of galactic and extra-galactic regions. Along with morphological information, the new spectral imaging system can be used to study the physical and chemical properties of regions of interest. Its three-dimensional imaging capabilities are critical for research into turbulence and dynamics. In addition, HARP/ACSIS will provide highly complementary science programmes to wide-field continuum studies, and produce the essential preparatory work for submillimetre interferometers such as the SMA and ALMA.
△ Less
Submitted 21 July, 2009;
originally announced July 2009.
-
Using administrative data to improve the estimation of immigration to local areas in England
Authors:
Peter Boden,
Phil Rees
Abstract:
International migration is now a significant driver of population change across Europe but the methods available to estimate its true impact upon sub-national areas remain inconsistent, constrained by inadequate systems of measurement and data capture. In the absence of a population register for England, official statistics on immigration and emigration are derived from a combination of survey a…
▽ More
International migration is now a significant driver of population change across Europe but the methods available to estimate its true impact upon sub-national areas remain inconsistent, constrained by inadequate systems of measurement and data capture. In the absence of a population register for England, official statistics on immigration and emigration are derived from a combination of survey and census sources. This paper demonstrates how administrative data systems such as those which capture registrations of recent migrants with a local doctor, National Insurance Number registrations by workers from abroad and the registration of foreign students for higher education, can provide data to better understand patterns and trends in international migration. The paper proposes a model for the estimation of immigration at a local level, integrating existing national estimates from the Office for National Statistics with data from these administrative sources. The model attempts to circumvent conceptual differences between datasets through the use of proportional distributions rather than absolute migrant counts in the estimation process. The model methodology and the results it produces provide alternative estimates of immigration for consideration by the Office for National Statistics as it develops its own programme of improvement to sub-national migration statistics.
△ Less
Submitted 24 August, 2009; v1 submitted 3 March, 2009;
originally announced March 2009.
-
Seeing statistics at the upgraded 3.8m UK infrared telescope (UKIRT)
Authors:
Marc S. Seigar,
Andy J. Adamson,
Nicholas P. Rees,
Timothy G. Hawarden,
Malcolm Currie,
Timothy C. Chuter
Abstract:
From 1991 until 1997, the 3.8m UK Infrared Telescope (UKIRT) underwent a programme of upgrades aimed at improving its intrinsic optical performance. This resulted in images with a FWHM of 0."17 at 2.2 um in September 1998. To understand and maintain the improvements to the delivered image quality since the completion of the upgrades programme, we have regularly monitored the overall atmospheric…
▽ More
From 1991 until 1997, the 3.8m UK Infrared Telescope (UKIRT) underwent a programme of upgrades aimed at improving its intrinsic optical performance. This resulted in images with a FWHM of 0."17 at 2.2 um in September 1998. To understand and maintain the improvements to the delivered image quality since the completion of the upgrades programme, we have regularly monitored the overall atmospheric seeing, as measured by radial displacements of subaperture images (i.e. seeing-generated focus fluctuations), and the delivered image diameters. The latter have been measured and recorded automatically since the beginning of 2001 whenever the facility imager UFTI (UKIRT Fast Track Imager) has been in use.
In this paper we report the results of these measurements. We investigate the relation between the delivered image diameter and the RMS atmospheric seeing (as measured by focus fluctuations, mentioned above). We find that the best seeing occurs in the second half of the night, generally after 2am HST and that the best seeing occurs in the summer between the months of July and September. We also find that the relationship between Zrms and delivered image diameter is uncertain. As a result Zrms frequently predicts a larger FWHM than that measured in the images.
Finally, we show that there is no correlation between near-infrared seeing measured at UKIRT and sub-mm seeing measured at the Caltech Submillimetre Observatory (CSO).
△ Less
Submitted 25 August, 2002;
originally announced August 2002.