SANDD: A directional antineutrino detector with segmented 6Li-doped pulse-shape-sensitive plastic scintillator
Authors:
F. Sutanto,
T. M. Classen,
S. A. Dazeley,
M. J. Duvall,
I. Jovanovic,
V. A. Li,
A. N. Mabe,
E. T. E. Reedy,
T. Wu
Abstract:
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was d…
▽ More
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were established to isolate antineutrino inverse beta decay events while rejecting large fraction of backgrounds. The neutron and positron detection efficiencies are estimated to be 34.8% and 80.2%, respectively, while the coincidence detection efficiency is estimated to be 71.7%, resulting in inverse beta decay detection efficiency of 20.05 +/- 0.2%(stat.) +/- 2.1%(syst.). The predicted directional sensitivity of SANDD produces an uncertainty of 20 degree in the azimuthal direction per 100 detected antineutrino events.
△ Less
Submitted 30 April, 2021;
originally announced May 2021.
A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays
Authors:
Viacheslav A. Li,
Timothy M. Classen,
Steven A. Dazeley,
Mark J. Duvall,
Igor Jovanovic,
Andrew N. Mabe,
Edward T. E. Reedy,
Felicia Sutanto
Abstract:
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will event…
▽ More
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of $^{6}$Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm $\times$ 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gamma-ray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.
△ Less
Submitted 11 August, 2019; v1 submitted 27 March, 2019;
originally announced March 2019.