CUTE: A Cryogenic Underground TEst Facility at SNOLAB
Authors:
Philippe Camus,
Jonathan Corbett,
Sean Crawford,
Koby Dering,
Eleanor Fascione,
Gilles Gerbier,
Richard Germond,
Muad Ghaith,
Jeter Hall,
Ziqing Hong,
Andrew Kubik,
Adam Mayer,
Serge Nagorny,
Payam Pakarha,
Wolfgang Rau,
Silvia Scorza,
Ryan Underwood
Abstract:
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range. Devices based on these technologies are often sensitive to small energy depositions as can be caused by environmental radiation. The Cryogenic Underground TEst…
▽ More
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range. Devices based on these technologies are often sensitive to small energy depositions as can be caused by environmental radiation. The Cryogenic Underground TEst facility (CUTE) at SNOLAB is a platform for testing and operating cryogenic devices in an environment with low levels of background. The large experimental chamber ($\mathcal{O}$(10) L) reaches a base temperature of $\sim$12 mK; it can hold a payload of up to $\sim$20 kg and provides a radiogenic background event rate as low as a few events/kg/keV/day in the energy range below about 100 keV, as well as a negligible muon rate ($\mathcal{O}$(1)/month). CUTE was designed and built in the context of the Super Cryogenic Dark Matter Search experiment (SuperCDMS) which uses cryogenic detectors to search for interactions of dark matter particles with ordinary matter. The facility has been used to test SuperCDMS detectors since its commissioning in 2019. In 2021, it was handed over to SNOLAB to become a SNOLAB user facility after the completion of the testing of detectors for SuperCDMS. The facility will be available for projects that benefit from these special conditions, based on proposals assessed for their scientific and technological merits. This article describes the main design features and operating parameters of CUTE.
△ Less
Submitted 30 January, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley,
H. Coombes
, et al. (108 additional authors not shown)
Abstract:
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nuc…
▽ More
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 17 February, 2023;
originally announced February 2023.
-
Effective Field Theory Analysis of CDMSlite Run 2 Data
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (105 additional authors not shown)
Abstract:
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected back…
▽ More
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
SuperCDMS Collaboration,
Musaab Al-Bakry,
Imran Alkhatib,
Dorian Praia do Amaral,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Iman Ataee Langroudy,
Elham Azadbakht,
Samir Banik,
Corey Bathurst,
Dan Bauer,
Lucas Bezerra,
Rik Bhattacharyya,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Robert Cameron,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Mouli Chaudhuri,
Ran Chen,
Nicholas Chott
, et al. (106 additional authors not shown)
Abstract:
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucle…
▽ More
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 19 May, 2022; v1 submitted 4 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trap** and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
Authors:
SuperCDMS Collaboration,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
H. Coombes,
J. Corbett
, et al. (82 additional authors not shown)
Abstract:
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 5…
▽ More
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.
△ Less
Submitted 18 January, 2021; v1 submitted 26 November, 2019;
originally announced November 2019.
-
Exploring the physics of neutron stars with high-resolution, high-throughput X-ray spectroscopy
Authors:
Jeremy Heyl,
Ilaria Caiazzo,
Samar Safi-Harb,
Craig Heinke,
Sharon Morsink,
Edward Cackett,
Alessandra De Rosa,
Marco Feroci,
Daniel S. Swetz,
Andrea Damascelli,
Pinder Dosanjh,
Sarah Gallagher,
Luigi Gallo,
Daryl Haggard,
Kelsey Hoffman,
Adam R. Ingram,
Demet Kirmizibayrak,
Herman Marshall,
Wolfgang Rau,
Paul Ripoche,
Gregory R. Sivakoff,
Ingrid Stairs,
Luigi Stella,
Joel N. Ullom
Abstract:
The advent of moderately high-resolution X-ray spectroscopy with Chandra and XMM promised to usher in a new age in the study of neutron stars: we thought we would study neutron stars like stars, with resolved absorption spectra revealing their surface chemical composition and physical conditions (e.g. surface gravity, pressure, temperature). Nature, however, did not cooperate in this endeavor, as…
▽ More
The advent of moderately high-resolution X-ray spectroscopy with Chandra and XMM promised to usher in a new age in the study of neutron stars: we thought we would study neutron stars like stars, with resolved absorption spectra revealing their surface chemical composition and physical conditions (e.g. surface gravity, pressure, temperature). Nature, however, did not cooperate in this endeavor, as observations of neutron stars have not revealed verified atomic absorption lines yet. In the near future, advancements in transition-edge sensors (TES) technology will allow for electron-volt-resolution spectroscopy combined with nanoseconds-precision timing. Combining these detectors with collector optics will also us to study neutron stars in much greater detail by achieving high-energy resolution with much larger collecting areas to uncover even weak spectral features over a wide range of the photon energies. Perhaps we will finally be able to study neutron stars like stars.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Testing general relativity with accretion onto compact objects
Authors:
Ilaria Caiazzo,
Jeremy Heyl,
Adam R. Ingram,
Tomaso Belloni,
Edward Cackett,
Alessandra De Rosa,
Marco Feroci,
Daniel S. Swetz,
Andrea Damascelli,
Pinder Dosanjh,
Sarah Gallagher,
Luigi Gallo,
Daryl Haggard,
Craig Heinke,
Kelsey Hoffman,
Demet Kirmizibayrak,
Sharon Morsink,
Wolfgang Rau,
Paul Ripoche,
Samar Safi-Harb,
Gregory R. Sivakoff,
Ingrid Stairs,
Luigi Stella,
Joel N. Ullom
Abstract:
The X-ray emission of neutron stars and black holes presents a rich phenomenology that can lead us to a better understanding of their nature and to address more general physics questions: Does general relativity apply in the strong gravity regime? Is spacetime around black holes described by the Kerr metric? This white paper considers how we can investigate these questions by studying reverberatio…
▽ More
The X-ray emission of neutron stars and black holes presents a rich phenomenology that can lead us to a better understanding of their nature and to address more general physics questions: Does general relativity apply in the strong gravity regime? Is spacetime around black holes described by the Kerr metric? This white paper considers how we can investigate these questions by studying reverberation map** and quasi-periodic oscillations in accreting systems with a combination of high-spectral and high-timing resolution. In the near future, we will be able to study compact objects in the X-rays in a new way: advancements in transition-edge sensors (TES) technology will allow for electron-volt-resolution spectroscopy combined with nanoseconds-precision timing.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Statistical challenges in the search for dark matter
Authors:
Sara Algeri,
Melissa van Beekveld,
Nassim Bozorgnia,
Alyson Brooks,
J. Alberto Casas,
Jessi Cisewski-Kehe,
Francis-Yan Cyr-Racine,
Thomas D. P. Edwards,
Fabio Iocco,
Bradley J. Kavanagh,
Judita Mamužić,
Siddharth Mishra-Sharma,
Wolfgang Rau,
Roberto Ruiz de Austri,
Benjamin R. Safdi,
Pat Scott,
Tracy R. Slatyer,
Yue-Lin Sming Tsai,
Aaron C. Vincent,
Christoph Weniger,
Jennifer Rittenhouse West,
Robert L. Wolpert
Abstract:
The search for the particle nature of dark matter has given rise to a number of experimental, theoretical and statistical challenges. Here, we report on a number of these statistical challenges and new techniques to address them, as discussed in the DMStat workshop held Feb 26 - Mar 3 2018 at the Banff International Research Station for Mathematical Innovation and Discovery (BIRS) in Banff, Albert…
▽ More
The search for the particle nature of dark matter has given rise to a number of experimental, theoretical and statistical challenges. Here, we report on a number of these statistical challenges and new techniques to address them, as discussed in the DMStat workshop held Feb 26 - Mar 3 2018 at the Banff International Research Station for Mathematical Innovation and Discovery (BIRS) in Banff, Alberta.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Authors:
Robert Agnese,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Elham Azadbakht,
William Baker,
Samir Banik,
D'Ann Barker,
Dan Bauer,
Thomas Binder,
Michael Bowles,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Jodi Cooley,
Brett Cornell,
Priscilla Cushman,
Philippe Di Stefano,
Todd Doughty,
Eleanor Fascione,
Tali Figueroa
, et al. (72 additional authors not shown)
Abstract:
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which w…
▽ More
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
△ Less
Submitted 16 April, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Design and Construction of the DEAP-3600 Dark Matter Detector
Authors:
P. -A. Amaudruz,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
S. Dittmeier,
F. A. Duncan
, et al. (84 additional authors not shown)
Abstract:
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a…
▽ More
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.
△ Less
Submitted 10 April, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (79 additional authors not shown)
Abstract:
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ (…
▽ More
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the strongest limits for WIMP--germanium-nucleus interactions for masses $>$12 GeV/$c^2$.
△ Less
Submitted 29 August, 2017;
originally announced August 2017.
-
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Authors:
DEAP-3600 Collaboration,
:,
P. -A. Amaudruz,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
S. Dittmeier
, et al. (81 additional authors not shown)
Abstract:
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produ…
▽ More
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage $<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/c$^2$ WIMP mass (90% C.L.).
△ Less
Submitted 13 August, 2018; v1 submitted 25 July, 2017;
originally announced July 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
S. Dittmeier,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile…
▽ More
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.
△ Less
Submitted 29 January, 2019; v1 submitted 29 May, 2017;
originally announced May 2017.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Improved WIMP-search reach of the CDMS II germanium data
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano
, et al. (64 additional authors not shown)
Abstract:
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity n…
▽ More
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there were zero candidate events above a deposited energy of 10 keV and 6 events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and $1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$ WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
△ Less
Submitted 13 October, 2015; v1 submitted 22 April, 2015;
originally announced April 2015.
-
Dark matter effective field theory scattering in direct detection experiments
Authors:
K. Schneck,
B. Cabrera,
D. G. Cerdeno,
V. Mandic,
H. E. Rogers,
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
D. O. Caldwell,
R. Calkins,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman
, et al. (62 additional authors not shown)
Abstract:
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter paramete…
▽ More
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when develo** signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.
△ Less
Submitted 16 August, 2016; v1 submitted 11 March, 2015;
originally announced March 2015.
-
DEAP-3600 Dark Matter Search
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Chen,
R. Chouinard,
B. T. Cleveland,
K. Dering,
J. DiGioseffo,
F. Duncan,
T. Flower,
R. Ford,
P. Giampa,
P. Gorel,
K. Graham,
D. R. Grant,
E. Guliyev,
A. L. Hallin,
M. Hamstra
, et al. (32 additional authors not shown)
Abstract:
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds…
▽ More
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds and helped to develop low radioactivity techniques to mitigate surface-related $α$ backgrounds. Construction of the DEAP-3600 detector is nearly complete and commissioning is starting in 2014. The target sensitivity to spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of magnitude improvement in sensitivity over current searches at 100 GeV WIMP mass. This paper presents an overview and status of the DEAP-3600 project and discusses plans for a future multi-tonne experiment, DEAP-50T.
△ Less
Submitted 25 August, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.
-
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
E. Do Couto E Silva
, et al. (66 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206P…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
△ Less
Submitted 11 October, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Silicon detector results from the first five-tower run of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
P. C. F. Di Stefano,
E. do Couto e Silva
, et al. (65 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 k…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
△ Less
Submitted 14 September, 2013; v1 submitted 12 April, 2013;
originally announced April 2013.
-
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
K. Boudjemline,
M. G. Boulay B. Cai T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Contreras,
K. Dering,
F. Duncan,
R. Ford,
R. Gagnon F. Giuliani,
M. Gold V. V. Golovko,
P. Gorel,
K. Graham,
D. R. Grant,
R. Hakobyan,
A. L. Hallin,
P. Harvey,
C. Hearns,
C. J. Jillings,
M. Kuźniak,
I. Lawson,
O. Li
, et al. (27 additional authors not shown)
Abstract:
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.…
▽ More
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
△ Less
Submitted 23 April, 2014; v1 submitted 5 November, 2012;
originally announced November 2012.
-
Search for annual modulation in low-energy CDMS-II data
Authors:
CDMS Collaboration,
Z. Ahmed,
D. S. Akerib,
A. J. Anderson,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
P. Cushman,
M. Daal,
F. DeJongh,
P. C. F. Di Stefano,
M. R. Dragowsky,
S. Fallows,
E. Figueroa-Feliciano,
J. Filippini,
J. Fox,
M. Fritts
, et al. (42 additional authors not shown)
Abstract:
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactio…
▽ More
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactions consistent with nuclear recoils, and constrain the magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9 keVnr energy range at the 99% confidence level. These results disfavor an explanation for the reported modulation in the 1.2-3.2 keVee energy range in CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs at >98% confidence. For events consistent with electron recoils, no significant modulation is observed for either single- or multiple-detector interactions in the 3.0-7.4 keVee range.
△ Less
Submitted 18 September, 2012; v1 submitted 6 March, 2012;
originally announced March 2012.
-
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
Authors:
CDMS,
EDELWEISS Collaborations,
:,
Z. Ahmed,
D. S. Akerib,
E. Armengaud,
S. Arrenberg,
C. Augier,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
A. Benoît,
L. Bergé,
J. Blümer,
P. L. Brink,
A. Broniatowski,
T. Bruch,
V. Brudanin,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
B. Censier,
M. Chapellier,
G. Chardin
, et al. (92 additional authors not shown)
Abstract:
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon…
▽ More
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
△ Less
Submitted 8 July, 2011; v1 submitted 17 May, 2011;
originally announced May 2011.
-
Dark Matter Search Experiments
Authors:
Wolfgang Rau
Abstract:
Astronomical and cosmological observations of the past 80 years build solid evidence that atomic matter makes up only a small fraction of the matter in the universe. The dominant fraction does not interact with electromagnetic radiation, does not absorb or emit light and hence is called Dark Matter. So far dark matter has revealed its existence only through gravitational effects. The strongest exp…
▽ More
Astronomical and cosmological observations of the past 80 years build solid evidence that atomic matter makes up only a small fraction of the matter in the universe. The dominant fraction does not interact with electromagnetic radiation, does not absorb or emit light and hence is called Dark Matter. So far dark matter has revealed its existence only through gravitational effects. The strongest experimental effort to find other evidence and learn more about the nature of the dark matter particles concentrates around Weakly Interacting Massive Particles which are among the best motivated dark matter candidates. The two main groups of experiments in this field aim for indirect detection through annihilation products and direct detection via interactions with atomic matter respectively. The experimental sensitivity is starting to reach the parameter range which is preferred by theoretical considerations and we can expect to confirm or dismiss some of the most interesting theoretical models in the next few years.
△ Less
Submitted 27 March, 2011;
originally announced March 2011.
-
Search for inelastic dark matter with the CDMS II experiment
Authors:
CDMS Collaboration,
Z. Ahmed,
D. S. Akerib,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
E. do Couto e Silva,
P. Cushman,
M. Daal,
F. DeJongh,
P. Di Stefano,
M. R. Dragowsky,
L. Duong,
S. Fallows,
E. Figueroa-Feliciano,
J. Filippini,
J. Fox
, et al. (41 additional authors not shown)
Abstract:
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the ine…
▽ More
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.
△ Less
Submitted 12 June, 2011; v1 submitted 22 December, 2010;
originally announced December 2010.
-
Results from a Low-Energy Analysis of the CDMS II Germanium Data
Authors:
CDMS Collaboration,
Z. Ahmed,
D. S. Akerib,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
E. do Couto e Silva,
P. Cushman,
M. Daal,
F. DeJongh,
P. Di Stefano,
M. R. Dragowsky,
L. Duong,
S. Fallows,
E. Figueroa-Feliciano,
J. Filippini,
J. Fox
, et al. (40 additional authors not shown)
Abstract:
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below…
▽ More
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.
△ Less
Submitted 21 April, 2011; v1 submitted 10 November, 2010;
originally announced November 2010.
-
Low-threshold analysis of CDMS shallow-site data
Authors:
CDMS Collaboration,
D. S. Akerib,
M. J. Attisha,
L. Baudis,
D. A. Bauer,
A. I. Bolozdynya,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
C. L. Chang,
R. M. Clarke,
J. Cooley,
M. B. Crisler,
P. Cushman,
F. DeJongh,
R. Dixon,
D. D. Driscoll,
J. Filippini,
S. Funkhouser,
R. J. Gaitskell,
S. R. Golwala,
D. Holmgren,
L. Hsu,
M. E. Huber
, et al. (23 additional authors not shown)
Abstract:
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the ge…
▽ More
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments' data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c^2 and 4 GeV/c^2.
△ Less
Submitted 3 January, 2011; v1 submitted 20 October, 2010;
originally announced October 2010.
-
Analysis of the low-energy electron-recoil spectrum of the CDMS experiment
Authors:
Z. Ahmed,
D. S. Akerib,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
J. Beaty,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
P. Cushman,
F. DeJongh,
M. R. Dragowsky,
L. Duong,
E. Figueroa-Feliciano,
J. Filippini,
M. Fritts,
S. R. Golwala,
D. R. Grant,
J. Hall,
R. Hennings-Yeomans
, et al. (32 additional authors not shown)
Abstract:
We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2 - 8.5 keV. We find no significant excess in the counting rate above background, and compare this observation to the recent DAMA results. I…
▽ More
We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2 - 8.5 keV. We find no significant excess in the counting rate above background, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA by 8.9$σ$. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z^2 scaling. With this assumption the observed rate in DAMA differs from the upper limit in CDMS by 6.8$σ$. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of ~2 less than observed by DAMA, constraining some possible interpretations of this modulation.
△ Less
Submitted 9 July, 2009;
originally announced July 2009.
-
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
K. Boudjemline,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
F. Duncan,
N. Fatemighomi,
R. Ford,
R. Gagnon,
P. Giampa,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel
, et al. (47 additional authors not shown)
Abstract:
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be…
▽ More
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale.
We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.
△ Less
Submitted 14 September, 2016; v1 submitted 20 April, 2009;
originally announced April 2009.
-
Neutron Scattering Facility for Characterization of CRESST and EURECA Detectors at mK Temperatures
Authors:
J. -C. Lanfranchi,
C. Ciemniak,
C. Coppi,
F. von Feilitzsch,
A. Gütlein,
H. Hagn,
C. Isaila,
J. Jochum,
M. Kimmerle,
S. Pfister,
W. Potzel,
W. Rau,
S. Roth,
K. Rottler,
C. Sailer,
S. Scholl,
I. Usherov,
W. Westphal
Abstract:
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an experiment located at the Gran Sasso underground laboratory and aimed at the direct detection of dark matter in the form of WIMPs. The setup has just completed a one year commissioning run in 2007 and is presently starting a physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$ single crystals, oper…
▽ More
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an experiment located at the Gran Sasso underground laboratory and aimed at the direct detection of dark matter in the form of WIMPs. The setup has just completed a one year commissioning run in 2007 and is presently starting a physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$ single crystals, operated at temperatures of a few millikelvin, are used as target to detect the tiny nuclear recoil induced by a WIMP. The powerful background identification and rejection of $α$, e$^{-}$ and $γ$ events is realized via the simultaneous measurement of a phonon and a scintillation signal generated in the $\mathrm{CaWO_4}$ crystal. However, neutrons could still be misidentified as a WIMP signature. Therefore, a detailed understanding of the individual recoil behaviour in terms of phonon generation and scintillation light emission due to scattering on Ca, O or W nuclei, respectively, is mandatory. The only setup which allows to perform such measurements at the operating temperature of the CRESST detectors has been installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is presently being commissioned. The design of this neutron scattering facility is such that it can also be used for other target materials, e.g. $\mathrm{ZnWO_4}$, $\mathrm{PbWO_4}$ and others as foreseen in the framework of the future multitarget tonne-scale experiment EURECA (European Underground Rare Event Calorimeter Array).
△ Less
Submitted 1 October, 2008;
originally announced October 2008.
-
Commissioning Run of the CRESST-II Dark Matter Search
Authors:
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
B. Majorovits,
M. Malek,
R. McGowan
, et al. (18 additional authors not shown)
Abstract:
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect…
▽ More
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect the scintillation light from the CaWO_4.Information from light-quenching factor studies allows the definition of a region of the energy-light yield plane which corresponds to tungsten recoils. A neutron test is reported which supports the principle of using the light yield to identify the recoiling nucleus.
Data obtained with two detector modules for a total exposure of 48 kg-days are presented. Judging by the rate of events in the "all nuclear recoils" acceptance region the apparatus shows a factor ~ten improvement with respect to previous results, which we attribute principally to the presence of the neutron shield.
In the "tungsten recoils" acceptance region three events are found, corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark matter flux, coherent or spin independent interactions,then yield a limit for WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
△ Less
Submitted 16 February, 2009; v1 submitted 10 September, 2008;
originally announced September 2008.
-
The CRESST Dark Matter Search
Authors:
B. Majorovits,
G. Angloher,
C. Bucci,
P. Christ,
C. Cozzini,
F. von Feilitzsch,
D. Hauff,
S. Henry,
Th. Jagemann,
J. Jochum,
H. Kraus,
V. Mikhailik,
J. Ninkovic,
F. Petricca,
W. Potzel,
F. Proebst,
Y. Ramachers,
M. Razeti,
W. Rau,
W. Seidel,
M. Stark,
L. Stodolsky,
A. J. B. Tolhurst,
D. Wahl,
W. Westphal
, et al. (1 additional authors not shown)
Abstract:
We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils. The observed count rate in the neutron band is compatible with the rate expected from neutron background. CRESST is presently being upgraded…
▽ More
We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils. The observed count rate in the neutron band is compatible with the rate expected from neutron background. CRESST is presently being upgraded with a 66 channel SQUID readout system, a neutron shield and a muon veto system. This results in a significant improvement in sensitivity.
△ Less
Submitted 15 November, 2004;
originally announced November 2004.
-
Detection of the Natural Alpha Decay of Tungsten
Authors:
C. Cozzini,
G. Angloher,
C. Bucci,
F. von Feilitzsch,
D. Hauff,
S. Henry,
Th. Jagemann,
J. Jochum,
H. Kraus,
B. Majorovits,
V. Mikhailik,
J. Ninkovic,
F. Petricca,
W. Potzel,
F. Proebst,
Y. Ramachers,
W. Rau,
M. Razeti,
W. Seidel,
M. Stark,
L. Stodolsky,
A. J. B. Tolhurst,
W. Westphal,
H. Wulandari
Abstract:
The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the simultaneous measurement of phonon and light signals with the CRESST cryogenic detectors. A half-life of T1/2 = (1.8 +- 0.2) x 10^18 y and an energy release of Q = (2516.4 +- 1.1 (stat.) +- 1.2 (sys.)) ke…
▽ More
The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the simultaneous measurement of phonon and light signals with the CRESST cryogenic detectors. A half-life of T1/2 = (1.8 +- 0.2) x 10^18 y and an energy release of Q = (2516.4 +- 1.1 (stat.) +- 1.2 (sys.)) keV have been measured. New limits are also set on the half-lives of the other naturally occurring tungsten isotopes.
△ Less
Submitted 26 October, 2004; v1 submitted 6 August, 2004;
originally announced August 2004.