-
Efficient UAVs Deployment and Resource Allocation in UAV-Relay Assisted Public Safety Networks for Video Transmission
Authors:
Naveed Khan,
Ayaz Ahmad,
Abdul Wakeel,
Zeeshan Kaleem,
Bushra Rashid,
Waqas Khalid
Abstract:
Wireless communication highly depends on the cellular ground base station (GBS). A failure of the cellular GBS, fully or partially, during natural or man-made disasters creates a communication gap in the disaster-affected areas. In such situations, public safety communication (PSC) can significantly save the national infrastructure, property, and lives. Throughout emergencies, the PSC can provide…
▽ More
Wireless communication highly depends on the cellular ground base station (GBS). A failure of the cellular GBS, fully or partially, during natural or man-made disasters creates a communication gap in the disaster-affected areas. In such situations, public safety communication (PSC) can significantly save the national infrastructure, property, and lives. Throughout emergencies, the PSC can provide mission-critical communication and video transmission services in the affected area. Unmanned aerial vehicles (UAVs) as flying base stations (UAV-BSs) are particularly suitable for PSC services as they are flexible, mobile, and easily deployable. This manuscript considers a multi-UAV-assisted PSC network with an observational UAV receiving videos from the affected area's ground users (AGUs) and transmitting them to the nearby GBS via a relay UAV. The objective of the proposed study is to maximize the average utility of the video streams generated by the AGUs upon reaching the GBS. This is achieved by optimizing the positions of the observational and relay UAVs, as well as the distribution of communication resources, such as bandwidth, and transmit power, while satisfying the system-designed constraints, such as transmission rate, rate outage probability, transmit power budget, and available bandwidth. To this end, a joint UAVs placement and resource allocation problem is mathematically formulated. The proposed problem poses a significant challenge for a solution. Considering the block coordinate descent and successive convex approximation techniques, an efficient iterative algorithm is proposed. Finally, simulation results are provided which show that our proposed approach outperforms the existing methods.
△ Less
Submitted 3 January, 2024; v1 submitted 3 January, 2024;
originally announced January 2024.
-
Proximal Policy Optimization-Based Reinforcement Learning Approach for DC-DC Boost Converter Control: A Comparative Evaluation Against Traditional Control Techniques
Authors:
Utsab Saha,
Shakib Shahria,
A. B. M Harun-Ur Rashid
Abstract:
This article presents a proximal policy optimization (PPO) based reinforcement learning (RL) approach for DC-DC boost converter control, which is compared to traditional control methods. The performance of the PPO algorithm is evaluated using MATLAB Simulink co-simulation, and the results demonstrate that the most efficient approach for achieving short settling time and stability is to combine the…
▽ More
This article presents a proximal policy optimization (PPO) based reinforcement learning (RL) approach for DC-DC boost converter control, which is compared to traditional control methods. The performance of the PPO algorithm is evaluated using MATLAB Simulink co-simulation, and the results demonstrate that the most efficient approach for achieving short settling time and stability is to combine the PPO algorithm with reinforcement learning based control method. The simulation results indicate that the step response characteristics provided using the control method based on RL with the PPO algorithm outperform traditional control approaches, which can be used to improve DC-DC boost converter control. This research also highlights the inherent capability of the reinforcement learning method to enhance the performance of boost converter control.
△ Less
Submitted 4 October, 2023;
originally announced October 2023.
-
A Multi Constrained Transformer-BiLSTM Guided Network for Automated Sleep Stage Classification from Single-Channel EEG
Authors:
Farhan Sadik,
Md Tanvir Raihan,
Rifat Bin Rashid,
Minhjaur Rahman,
Sabit Md Abdal,
Shahed Ahmed,
Talha Ibn Mahmud
Abstract:
Sleep stage classification from electroencephalogram (EEG) is significant for the rapid evaluation of slee** patterns and quality. A novel deep learning architecture, ``DenseRTSleep-II'', is proposed for automatic sleep scoring from single-channel EEG signals. The architecture utilizes the advantages of Convolutional Neural Network (CNN), transformer network, and Bidirectional Long Short Term Me…
▽ More
Sleep stage classification from electroencephalogram (EEG) is significant for the rapid evaluation of slee** patterns and quality. A novel deep learning architecture, ``DenseRTSleep-II'', is proposed for automatic sleep scoring from single-channel EEG signals. The architecture utilizes the advantages of Convolutional Neural Network (CNN), transformer network, and Bidirectional Long Short Term Memory (BiLSTM) for effective sleep scoring. Moreover, with the addition of a weighted multi-loss scheme, this model is trained more implicitly for vigorous decision-making tasks. Thus, the model generates the most efficient result in the SleepEDFx dataset and outperforms different state-of-the-art (IIT-Net, DeepSleepNet) techniques by a large margin in terms of accuracy, precision, and F1-score.
△ Less
Submitted 19 September, 2023;
originally announced September 2023.
-
Bayesian Game Formulation of Power Allocation in Multiple Access Wiretap Channel with Incomplete CSI
Authors:
Basharat Rashid,
Majed Haddad,
Shahid Mehraj Shah
Abstract:
In this paper, we address the problem of distributed power allocation in a $K$ user fading multiple access wiretap channel, where global channel state information is limited, i.e., each user has knowledge of their own channel state with respect to Bob and Eve but only knows the distribution of other users' channel states. We model this problem as a Bayesian game, where each user is assumed to self…
▽ More
In this paper, we address the problem of distributed power allocation in a $K$ user fading multiple access wiretap channel, where global channel state information is limited, i.e., each user has knowledge of their own channel state with respect to Bob and Eve but only knows the distribution of other users' channel states. We model this problem as a Bayesian game, where each user is assumed to selfishly maximize his average \emph{secrecy capacity} with partial channel state information. In this work, we first prove that there is a unique Bayesian equilibrium in the proposed game. Additionally, the price of anarchy is calculated to measure the efficiency of the equilibrium solution. We also propose a fast convergent iterative algorithm for power allocation. Finally, the results are validated using simulation results.
△ Less
Submitted 4 September, 2023; v1 submitted 15 June, 2023;
originally announced June 2023.
-
Towards Devising A Fund Management System Using Blockchain
Authors:
Nibula Bente Rashid,
Joyeeta Saha,
Raonak Islam Prova,
Nowshin Tasfia,
Md. Nazrul Huda Shanto,
Jannatun Noor
Abstract:
State government operations comprise a large number of transactions for different processes that must be carried out across the state. This comprises new projects, maintenance and repairs, public employee compensation, and agricultural schemes. Low-level corruption, which is sometimes difficult to trace and hinders state growth, is a big challenge for the top administration. In order to eradicate…
▽ More
State government operations comprise a large number of transactions for different processes that must be carried out across the state. This comprises new projects, maintenance and repairs, public employee compensation, and agricultural schemes. Low-level corruption, which is sometimes difficult to trace and hinders state growth, is a big challenge for the top administration. In order to eradicate corruption and bring transparency, technology can be used in an efficient way. An important task to exterminate corruption is to keep track of all the financial transactions of an undergoing project. This research uses blockchain technology to keep track of fund management systems and assure the transparency of any financial statement. This paper proposes to use a gateway where all transaction records are updated in the system and visible to all stakeholders. We find research gaps in the literature and focus on including government funds and local currency usage. The proposed model's motive is to generate a funding model that attains two sub-goals: designing a fund management methodology in which authorized individuals can receive and withdraw allocated funds in crypto currency, and evaluating a smart contract to incorporate the money and identify transparency and tracking. The proposed model executes every feature of our system in just 8.3786ms on average.
△ Less
Submitted 4 December, 2022; v1 submitted 7 November, 2022;
originally announced November 2022.
-
Convolutional Neural Network Based Partial Face Detection
Authors:
Md. Towfiqul Islam,
Tanzim Ahmed,
A. B. M. Raihanur Rashid,
Taminul Islam,
Md. Sadekur Rahman,
Md. Tarek Habib
Abstract:
Due to the massive explanation of artificial intelligence, machine learning technology is being used in various areas of our day-to-day life. In the world, there are a lot of scenarios where a simple crime can be prevented before it may even happen or find the person responsible for it. A face is one distinctive feature that we have and can differentiate easily among many other species. But not ju…
▽ More
Due to the massive explanation of artificial intelligence, machine learning technology is being used in various areas of our day-to-day life. In the world, there are a lot of scenarios where a simple crime can be prevented before it may even happen or find the person responsible for it. A face is one distinctive feature that we have and can differentiate easily among many other species. But not just different species, it also plays a significant role in determining someone from the same species as us, humans. Regarding this critical feature, a single problem occurs most often nowadays. When the camera is pointed, it cannot detect a person's face, and it becomes a poor image. On the other hand, where there was a robbery and a security camera installed, the robber's identity is almost indistinguishable due to the low-quality camera. But just making an excellent algorithm to work and detecting a face reduces the cost of hardware, and it doesn't cost that much to focus on that area. Facial recognition, widget control, and such can be done by detecting the face correctly. This study aims to create and enhance a machine learning model that correctly recognizes faces. Total 627 Data have been collected from different Bangladeshi people's faces on four angels. In this work, CNN, Harr Cascade, Cascaded CNN, Deep CNN & MTCNN are these five machine learning approaches implemented to get the best accuracy of our dataset. After creating and running the model, Multi-Task Convolutional Neural Network (MTCNN) achieved 96.2% best model accuracy with training data rather than other machine learning models.
△ Less
Submitted 28 June, 2022;
originally announced June 2022.
-
Extreme softness of brain matter in simple shear
Authors:
Michel Destrade,
Michael D. Gilchrist,
Jerry G. Murphy,
Badar Rashid,
Giuseppe Saccomandi
Abstract:
We show that porcine brain matter can be modelled accurately as a very soft rubber-like material using the Mooney-Rivlin strain energy function, up to strains as high as 60\%. This result followed from simple shear experiments performed on small rectangular fresh samples ($2.5$ cm$^3$ and $1.1$ cm$^3$) at quasi-static strain rates. They revealed a linear shear stress--shear strain relationship (…
▽ More
We show that porcine brain matter can be modelled accurately as a very soft rubber-like material using the Mooney-Rivlin strain energy function, up to strains as high as 60\%. This result followed from simple shear experiments performed on small rectangular fresh samples ($2.5$ cm$^3$ and $1.1$ cm$^3$) at quasi-static strain rates. They revealed a linear shear stress--shear strain relationship ($R^2> 0.97 $), characteristic of Mooney-Rivlin materials at large strains. We found that porcine brain matter is about 30 times less resistant to shear forces than a silicone gel. We also verified experimentally that brain matter exhibits the positive Poynting effect of nonlinear elasticity, and numerically that the stress and strain fields remain mostly homogeneous throughout the thickness of the samples in simple shear.
△ Less
Submitted 13 September, 2020;
originally announced September 2020.
-
Mechanical characterization of brain tissue in simple shear at dynamic strain rates
Authors:
Badar Rashid,
Michel Destrade,
Michael D. Gilchrist
Abstract:
During severe impact conditions, brain tissue experiences a rapid and complex deformation, which can be seen as a mixture of compression, tension and shear. Moreover, diffuse axonal injury (DAI) occurs in animals and humans when both the strains and strain rates exceed 10% and 10/s, respectively. Knowing the mechanical properties of brain tissue in shear at these strains and strain rates is thus o…
▽ More
During severe impact conditions, brain tissue experiences a rapid and complex deformation, which can be seen as a mixture of compression, tension and shear. Moreover, diffuse axonal injury (DAI) occurs in animals and humans when both the strains and strain rates exceed 10% and 10/s, respectively. Knowing the mechanical properties of brain tissue in shear at these strains and strain rates is thus of particular importance, as they can be used in finite element simulations to predict the occurrence of brain injuries under different impact conditions. In this research, an experimental setup was developed to perform simple shear tests on porcine brain tissue at strain rates < 120/s. The maximum measured shear stress at strain rates of 30, 60, 90 and 120/s was 1.15 +/- 0.25 kPa, 1.34 +/- 0.19 kPa, 2.19 +/- 0.225 kPa and 2.52 +/- 0.27 kPa, (mean +/- SD), respectively, at the maximum amount of shear, K = 1. Good agreement of experimental, theoretical (Ogden and MooneyRivlin models) and numerical shear stresses was achieved (p = 0.7866 - 0.9935). Specimen thickness effects (2.0 - 10.0 mm thick specimens) were also analyzed numerically and we found that there is no significant difference (p = 0.9954) in the shear stress magnitudes, indicating a homogeneous deformation of the specimens during simple shear tests. Stress relaxation tests in simple shear were also conducted at different strain magnitudes (10% - 60% strain) with the average rise time of 14 ms. This allowed us to estimate elastic and viscoelastic parameters (mu = 4942.0 Pa and Prony parameters: g1 = 0.520, g2 = 0.3057, tau1 = 0.0264 s, tau2 = 0.011 s) that can be used in FE software to analyze the hyperviscoelastic behavior of brain tissue.
△ Less
Submitted 31 August, 2020;
originally announced September 2020.
-
Mechanical characterization of brain tissue in tension at dynamic strain rates
Authors:
Badar Rashid,
Michel Destrade,
Michael D. Gilchrist
Abstract:
Mechanical characterization of brain tissue at high loading velocities is crucial for modeling Traumatic Brain Injury (TBI). During severe impact conditions, brain tissue experiences compression, tension and shear. Limited experimental data is available for brain tissue in extension at dynamic strain rates. In this research, a High Rate Tension Device (HRTD) was developed to obtain dynamic propert…
▽ More
Mechanical characterization of brain tissue at high loading velocities is crucial for modeling Traumatic Brain Injury (TBI). During severe impact conditions, brain tissue experiences compression, tension and shear. Limited experimental data is available for brain tissue in extension at dynamic strain rates. In this research, a High Rate Tension Device (HRTD) was developed to obtain dynamic properties of brain tissue in extension at strain rates of < 90/s. In vitro tensile tests were performed to obtain properties of brain tissue at strain rates of 30, 60 and 90/s up to 30% strain. The brain tissue showed a stiffer response with increasing strain rates, showing that hyperelastic models are not adequate. Specifically, the tensile engineering stress at 30% strain was 3.1 +/- 0.49 kPa, 4.3 +/- 0.86 kPa, 6.5 +/- 0.76 kPa (mean +/- SD) at strain rates of 30, 60 and 90/s, respectively. Force relaxation tests in tension were also conducted at different strain magnitudes (10-60% strain) with the average rise time of 24 ms, which were used to derive time dependent parameters. One-term Ogden, Fung and Gent models were used to obtain material parameters from the experimental data. Numerical simulations were performed using a one-term Ogden model to analyze hyperelastic behavior of brain tissue up to 30% strain. The material parameters obtained in this study will help to develop biofidelic human brain finite element models, which can subsequently be used to predict brain injuries under impact conditions and as a reconstruction and simulation tool for forensic investigations.
△ Less
Submitted 31 August, 2020;
originally announced September 2020.
-
Influence of Preservation Temperature on the Measured Mechanical Properties of Brain Tissue
Authors:
Badar Rashid,
Michel Destrade,
Michael Gilchrist
Abstract:
The large variability in experimentally measured mechanical properties of brain tissue is due to many factors including heterogeneity, anisotropy, age dependence and post-mortem time. Moreover, differences in test protocols also influence these measured properties. This paper shows that the temperature at which porcine brain tissue is stored or preserved prior to testing has a significant effect o…
▽ More
The large variability in experimentally measured mechanical properties of brain tissue is due to many factors including heterogeneity, anisotropy, age dependence and post-mortem time. Moreover, differences in test protocols also influence these measured properties. This paper shows that the temperature at which porcine brain tissue is stored or preserved prior to testing has a significant effect on the mechanical properties of brain tissue, even when tests are conducted at the same temperatures. Three groups of brain tissue were stored separately for at least one hour at three different preservation temperatures, i.e., ice cold, room temperature (22C) and body temperature (37C), prior to them all being tested at room temperature (approx. 22C). Significant differences in the corresponding initial elastic shear modulus mu (Pa) (at various amounts of shear, K, i.e., 0-0.2) were observed. The initial elastic moduli were 1043 +/- 271 Pa, 714 +/- 210 Pa and 497 +/- 156 Pa (mean +/- SD) at preservation temperatures of ice cold, 22C and 37C, respectively. Based on this investigation, it is strongly recommended that brain tissue samples must be preserved at an ice-cold temperature prior to testing in order to minimize the difference between the measured in vitro test results and the in vivo properties. A by-product of the study is that simple shear tests allow for large, almost perfectly homogeneous deformation of brain matter.
△ Less
Submitted 2 June, 2013;
originally announced June 2013.
-
Differences in tension and compression in the nonlinearly elastic bending of beams
Authors:
Michel Destrade,
Jerry G. Murphy,
Badar Rashid
Abstract:
The classical flexure problem of non-linear incompressible elasticity is revisited for elastic materials whose mechanical response is different in tension and compression---the so-called bimodular materials. The flexure problem is chosen to investigate this response since the two regions, one of tension and one of compression, can be identified easily using simple intuition. Two distinct problems…
▽ More
The classical flexure problem of non-linear incompressible elasticity is revisited for elastic materials whose mechanical response is different in tension and compression---the so-called bimodular materials. The flexure problem is chosen to investigate this response since the two regions, one of tension and one of compression, can be identified easily using simple intuition. Two distinct problems are considered: the first is where the stress is assumed continuous across the boundary of the two regions, which assumption has a sound physical basis. The second problem considered is more speculative: it is where discontinuities of stress are allowed. It is shown that such discontinuities are necessarily small for many applications, but might nonetheless provide an explanation for the damage incurred by repeated flexure. Some experimental evidence of the possibility of bimodularity in elastomers is also presented.
△ Less
Submitted 8 March, 2013;
originally announced March 2013.
-
Determination of Friction Coefficient in Unconfined Compression of Brain Tissue
Authors:
Badar Rashid,
Michel Destrade,
Michael Gilchrist
Abstract:
Unconfined compression tests are more convenient to perform on cylindrical samples of brain tissue than tensile tests in order to estimate mechanical properties of the brain tissue because they allow for homogeneous deformations. The reliability of these tests depends significantly on the amount of friction generated at the specimen/platen interface. Thus, there is a crucial need to find an approx…
▽ More
Unconfined compression tests are more convenient to perform on cylindrical samples of brain tissue than tensile tests in order to estimate mechanical properties of the brain tissue because they allow for homogeneous deformations. The reliability of these tests depends significantly on the amount of friction generated at the specimen/platen interface. Thus, there is a crucial need to find an approximate value of the friction coefficient in order to predict a possible overestimation of stresses during unconfined compression tests. In this study, a combined experimental-computational approach was adopted to estimate the dynamic friction coefficient mu of porcine brain matter against metal platens in compressive tests. Cylindrical samples of porcine brain tissue were tested up to 30% strain at variable strain rates, both under bonded and lubricated conditions in the same controlled environment. It was established that mu was equal to 0.09 +/- 0.03, 0.18 +/- 0.04, 0.18 +/- 0.04 and 0.20 +/- 0.02 at strain rates of 1, 30, 60 and 90/s, respectively. Additional tests were also performed to analyze brain tissue under lubricated and bonded conditions, with and without initial contact of the top platen with the brain tissue, with different specimen aspect ratios and with different lubricants (Phosphate Buffer Saline (PBS), Polytetrafluoroethylene (PTFE) and Silicon). The test conditions (lubricant used, biological tissue, loading velocity) adopted in this study were similar to the studies conducted by other research groups. This study will help to understand the amount of friction generated during unconfined compression of brain tissue for strain rates of up to 90/s.
△ Less
Submitted 28 February, 2013;
originally announced March 2013.
-
Inhomogeneous Deformation of Brain Tissue During Tension Tests
Authors:
Badar Rashid,
Michel Destrade,
Michael D. Gilchrist
Abstract:
Mechanical characterization of brain tissue has been investigated extensively by various research groups over the past fifty years. These properties are particularly important for modelling Traumatic Brain Injury (TBI). In this research, we present the design and calibration of a High Rate Tension Device (HRTD) capable of performing tests up to a maximum strain rate of 90/s. We use experimental an…
▽ More
Mechanical characterization of brain tissue has been investigated extensively by various research groups over the past fifty years. These properties are particularly important for modelling Traumatic Brain Injury (TBI). In this research, we present the design and calibration of a High Rate Tension Device (HRTD) capable of performing tests up to a maximum strain rate of 90/s. We use experimental and numerical methods to investigate the effects of inhomogeneous deformation of porcine brain tissue during tension at different specimen thicknesses (4.0-14.0 mm), by performing tension tests at a strain rate of 30/s. One-term Ogden material parameters (mu = 4395.0 Pa, alpha = -2.8) were derived by performing an inverse finite element analysis to model all experimental data. A similar procedure was adopted to determine Young's modulus (E= 11200 Pa) of the linear elastic regime. Based on this analysis, brain specimens of aspect ratio (diameter/thickness) S < 1.0 are required to minimise the effects of inhomogeneous deformation during tension tests.
△ Less
Submitted 28 February, 2013;
originally announced March 2013.
-
Temperature Effects on Brain Tissue in Compression
Authors:
Badar Rashid,
Michel Destrade,
Michael Gilchrist
Abstract:
Extensive research has been carried out for at least 50 years to understand the mechanical properties of brain tissue in order to understand the mechanisms of traumatic brain injury (TBI). The observed large variability in experimental results may be due to the inhomogeneous nature of brain tissue and to the broad range of test conditions. However, test temperature is also considered as one of the…
▽ More
Extensive research has been carried out for at least 50 years to understand the mechanical properties of brain tissue in order to understand the mechanisms of traumatic brain injury (TBI). The observed large variability in experimental results may be due to the inhomogeneous nature of brain tissue and to the broad range of test conditions. However, test temperature is also considered as one of the factors influencing the properties of brain tissue. In this research, the mechanical properties of porcine brain have been investigated at 22C (room temperature) and at 37C (body temperature) while maintaining a constant preservation temperature of approximately 4-5C. Unconfined compression tests were performed at dynamic strain rates of 30 and 50/s using a custom made test apparatus. There was no significant difference (p = 0.8559 - 0.9290) between the average engineering stresses of the brain tissue at the two different temperature conditions. The results of this study should help to understand the behavior of brain tissue at different temperature conditions, particularly in unconfined compression tests.
△ Less
Submitted 28 February, 2013;
originally announced March 2013.
-
Mechanical Characterization of Brain Tissue in Compression at Dynamic Strain Rates
Authors:
Badar Rashid,
Michel Destrade,
Michael Gilchrist
Abstract:
Traumatic brain injury (TBI) occurs when local mechanical load exceeds certain tolerance levels for brain tissue. Extensive research has been done previously for brain matter experiencing compression at quasistatic loading; however, limited data is available to model TBI under dynamic impact conditions. In this research, an experimental setup was developed to perform unconfined compression tests a…
▽ More
Traumatic brain injury (TBI) occurs when local mechanical load exceeds certain tolerance levels for brain tissue. Extensive research has been done previously for brain matter experiencing compression at quasistatic loading; however, limited data is available to model TBI under dynamic impact conditions. In this research, an experimental setup was developed to perform unconfined compression tests and stress relaxation tests at strain rates < 90/s. The brain tissue showed a stiffer response with increasing strain rates, showing that hyperelastic models are not adequate. Specifically, the compressive nominal stress at 30% strain was 8.83 +/- 1.94, 12.8 +/- 3.10 and 16.0 +/- 1.41 kPa (mean +/- SD) at strain rates of 30, 60 and 90/s, respectively. Relaxation tests were also conducted at 10%-50% strain with the average rise time of 10 ms, which can be used to derive time dependent parameters. Numerical simulations were performed using one-term Ogden model with initial shear modulus mu_0 = 6.06 +/- 1.44, 9.44 +/- 2.427 and 12.64 +/- 1.227 kPa (mean +/- SD) at strain rates of 30, 60 and 90/s, respectively. A separate set of bonded and lubricated tests were also performed under the same test conditions to estimate the friction coefficient mu, by adopting combined experimental - computational approach. The values of mu were 0.1 +/- 0.03 and 0.15 +/- 0.07 (mean +/- SD) at 30 and 90/s strain rates, respectively, indicating that pure slip conditions cannot be achieved in unconfined compression tests even under fully lubricated test conditions. The material parameters obtained in this study will help to develop biofidelic human brain finite element models, which can subsequently be used to predict brain injuries under impact conditions.
△ Less
Submitted 19 February, 2013;
originally announced February 2013.
-
A High Rate Tension Device for Characterizing Brain Tissue
Authors:
Badar Rashid,
Michel Destrade,
Michael Gilchrist
Abstract:
The mechanical characterization of brain tissue at high loading velocities is vital for understanding and modeling Traumatic Brain Injury (TBI). The most severe form of TBI is diffuse axonal injury (DAI) which involves damage to individual nerve cells (neurons). DAI in animals and humans occurs at strains > 10% and strain rates > 10/s. The mechanical properties of brain tissues at these strains an…
▽ More
The mechanical characterization of brain tissue at high loading velocities is vital for understanding and modeling Traumatic Brain Injury (TBI). The most severe form of TBI is diffuse axonal injury (DAI) which involves damage to individual nerve cells (neurons). DAI in animals and humans occurs at strains > 10% and strain rates > 10/s. The mechanical properties of brain tissues at these strains and strain rates are of particular significance, as they can be used in finite element human head models to accurately predict brain injuries under different impact conditions. Existing conventional tensile testing machines can only achieve maximum loading velocities of 500 mm/min, whereas the Kolsky bar apparatus is more suitable for strain rates > 100/s. In this study, a custom-designed high rate tension device is developed and calibrated to estimate the mechanical properties of brain tissue in tension at strain rates < 90/s, while maintaining a uniform velocity. The range of strain can also be extended to 100% depending on the thickness of a sample. The same apparatus can be used to characterize the dynamic behavior of skin and other soft biological tissues by using appropriately sized load cells with a capacity of 10 N and above.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.