Impedance-matched differential superconducting nanowire detectors
Authors:
Marco Colangelo,
Boris Korzh,
Jason P. Allmaras,
Andrew D. Beyer,
Andrew S. Mueller,
Ryan M. Briggs,
Bruce Bumble,
Marcus Runyan,
Martin J. Stevens,
Adam N. McCaughan,
Di Zhu,
Stephen Smith,
Wolfgang Becker,
Lautaro Narváez,
Joshua C. Bienfang,
Simone Frasca,
Angel E. Velasco,
Cristián H. Peña,
Edward E. Ramirez,
Alexander B. Walter,
Ekkehart Schmidt,
Emma E. Wollman,
Maria Spiropulu,
Richard Mirin,
Sae Woo Nam
, et al. (2 additional authors not shown)
Abstract:
Superconducting nanowire single-photon detectors (SNSPDs) are the highest performing photon-counting technology in the near-infrared (NIR). Due to delay-line effects, large area SNSPDs typically trade-off timing resolution and detection efficiency. Here, we introduce a detector design based on transmission line engineering and differential readout for device-level signal conditioning, enabling a h…
▽ More
Superconducting nanowire single-photon detectors (SNSPDs) are the highest performing photon-counting technology in the near-infrared (NIR). Due to delay-line effects, large area SNSPDs typically trade-off timing resolution and detection efficiency. Here, we introduce a detector design based on transmission line engineering and differential readout for device-level signal conditioning, enabling a high system detection efficiency and a low detector jitter, simultaneously. To make our differential detectors compatible with single-ended time taggers, we also engineer analog differential-to-single-ended readout electronics, with minimal impact on the system timing resolution. Our niobium nitride differential SNSPDs achieve $47.3\,\% \pm 2.4\,\%$ system detection efficiency and sub-$10\,\mathrm{ps}$ system jitter at $775\,\mathrm{nm}$, while at $1550\,\mathrm{nm}$ they achieve $71.1\,\% \pm 3.7\,\%$ system detection efficiency and $13.1\,\mathrm{ps} \pm 0.4\,\mathrm{ps}$ system jitter. These detectors also achieve sub-100 ps timing response at one one-hundredth maximum level, $30.7\,\mathrm{ps} \pm 0.4\,\mathrm{ps}$ at $775\,\mathrm{nm}$ and $47.6\,\mathrm{ps} \pm 0.4\,\mathrm{ps}$ at $1550\,\mathrm{nm}$, enabling time-correlated single-photon counting with high dynamic range response functions. Furthermore, thanks to the differential impedance-matched design, our detectors exhibit delay-line imaging capabilities and photon-number resolution. The properties and high-performance metrics achieved by our system make it a versatile photon-detection solution for many scientific applications.
△ Less
Submitted 17 August, 2021;
originally announced August 2021.