-
Characterisation of analogue Monolithic Active Pixel Sensor test structures implemented in a 65 nm CMOS imaging process
Authors:
Gianluca Aglieri Rinella,
Giacomo Alocco,
Matias Antonelli,
Roberto Baccomi,
Stefania Maria Beole,
Mihail Bogdan Blidaru,
Bent Benedikt Buttwill,
Eric Buschmann,
Paolo Camerini,
Francesca Carnesecchi,
Marielle Chartier,
Yongjun Choi,
Manuel Colocci,
Giacomo Contin,
Dominik Dannheim,
Daniele De Gruttola,
Manuel Del Rio Viera,
Andrea Dubla,
Antonello di Mauro,
Maurice Calvin Donner,
Gregor Hieronymus Eberwein,
Jan Egger,
Laura Fabbietti,
Finn Feindt,
Kunal Gautam
, et al. (69 additional authors not shown)
Abstract:
Analogue test structures were fabricated using the Tower Partners Semiconductor Co. CMOS 65 nm ISC process. The purpose was to characterise and qualify this process and to optimise the sensor for the next generation of Monolithic Active Pixels Sensors for high-energy physics. The technology was explored in several variants which differed by: do** levels, pixel geometries and pixel pitches (10-25…
▽ More
Analogue test structures were fabricated using the Tower Partners Semiconductor Co. CMOS 65 nm ISC process. The purpose was to characterise and qualify this process and to optimise the sensor for the next generation of Monolithic Active Pixels Sensors for high-energy physics. The technology was explored in several variants which differed by: do** levels, pixel geometries and pixel pitches (10-25 $μ$m). These variants have been tested following exposure to varying levels of irradiation up to 3 MGy and $10^{16}$ 1 MeV n$_\text{eq}$ cm$^{-2}$. Here the results from prototypes that feature direct analogue output of a 4$\times$4 pixel matrix are reported, allowing the systematic and detailed study of charge collection properties. Measurements were taken both using $^{55}$Fe X-ray sources and in beam tests using minimum ionizing particles. The results not only demonstrate the feasibility of using this technology for particle detection but also serve as a reference for future applications and optimisations.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
-
Digital Pixel Test Structures implemented in a 65 nm CMOS process
Authors:
Gianluca Aglieri Rinella,
Anton Andronic,
Matias Antonelli,
Mauro Aresti,
Roberto Baccomi,
Pascal Becht,
Stefania Beole,
Justus Braach,
Matthew Daniel Buckland,
Eric Buschmann,
Paolo Camerini,
Francesca Carnesecchi,
Leonardo Cecconi,
Edoardo Charbon,
Giacomo Contin,
Dominik Dannheim,
Joao de Melo,
Wen**g Deng,
Antonello di Mauro,
Jan Hasenbichler,
Hartmut Hillemanns,
Geun Hee Hong,
Artem Isakov,
Antoine Junique,
Alex Kluge
, et al. (27 additional authors not shown)
Abstract:
The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20 to 40 um and bent to form truly cylindrical half barrels. Among the…
▽ More
The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20 to 40 um and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article.
The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at +20 C and a detection efficiency of 99% for a DPTS irradiated with a dose of $10^{15}$ 1 MeV n$_{\mathrm{eq}}/$cm$^2$. Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.
△ Less
Submitted 10 July, 2023; v1 submitted 16 December, 2022;
originally announced December 2022.
-
Design, integration, and test of the scientific payloads on-board the HERMES constellation and the SpIRIT mission
Authors:
Y. Evangelista,
F. Fiore,
R. Campana,
F. Ceraudo,
G. Della Casa,
E. Demenev,
G. Dilillo,
M. Fiorini,
M. Grassi,
A. Guzman,
P. Hedderman,
E. J. Marchesini,
G. Morgante,
F. Mele,
P. Nogara,
A. Nuti,
R. Piazzolla,
S. Pliego Caballero,
I. Rashevskaya,
F. Russo,
G. Sottile,
C. Labanti,
G. Baroni,
P. Bellutti,
G. Bertuccio
, et al. (19 additional authors not shown)
Abstract:
HERMES (High Energy Rapid Modular Ensemble of Satellites) is a space-borne mission based on a constellation of nano-satellites flying in a low-Earth orbit (LEO). The six 3U CubeSat buses host new miniaturized instruments hosting a hybrid Silicon Drift Detector/GAGG:Ce scintillator photodetector system sensitive to X-rays and gamma-rays. HERMES will probe the temporal emission of bright high-energy…
▽ More
HERMES (High Energy Rapid Modular Ensemble of Satellites) is a space-borne mission based on a constellation of nano-satellites flying in a low-Earth orbit (LEO). The six 3U CubeSat buses host new miniaturized instruments hosting a hybrid Silicon Drift Detector/GAGG:Ce scintillator photodetector system sensitive to X-rays and gamma-rays. HERMES will probe the temporal emission of bright high-energy transients such as Gamma-Ray Bursts (GRBs), ensuring a fast transient localization (with arcmin-level accuracy) in a field of view of several steradians exploiting the triangulation technique. With a foreseen launch date in late 2023, HERMES transient monitoring represents a keystone capability to complement the next generation of gravitational wave experiments. Moreover, the HERMES constellation will operate in conjunction with the Space Industry Responsive Intelligent Thermal (SpIRIT) 6U CubeSat, to be launched in early 2023. SpIRIT is an Australian-Italian mission for high-energy astrophysics that will carry in a Sun-synchronous orbit (SSO) an actively cooled HERMES detector system payload. On behalf of the HERMES collaboration, in this paper we will illustrate the HERMES and SpIRIT payload design, integration and tests, highlighting the technical solutions adopted to allow a wide-energy-band and sensitive X-ray and gamma-ray detector to be accommodated in a 1U Cubesat volume.
△ Less
Submitted 25 October, 2022;
originally announced October 2022.
-
X-Ray Silicon Drift Detector-CMOS Front-End System with High Energy Resolution at Room Temperature
Authors:
G. Bertuccio,
M. Ahangarianabhari,
C. Graziani,
D. Macera,
Y. Shi,
M. Gandola,
A. Rachevski,
I. Rashevskaya,
A. Vacchi,
G. Zampa,
N. Zampa,
P. Bellutti,
G. Giacomini,
A. Picciotto,
C. Piemonte,
N. Zorzi
Abstract:
We present a spectroscopic system constituted by a Silicon Drift Detector (SDD) coupled to a CMOS charge sensitive preamplifier, named SIRIO, specifically designed to reach ultimate low noise levels. The SDD, with an active area of 13 mm , has been manufactured by optimizing the production processes in order to reduce the anode current, successfully reaching current densities between 17 pA/cm and…
▽ More
We present a spectroscopic system constituted by a Silicon Drift Detector (SDD) coupled to a CMOS charge sensitive preamplifier, named SIRIO, specifically designed to reach ultimate low noise levels. The SDD, with an active area of 13 mm , has been manufactured by optimizing the production processes in order to reduce the anode current, successfully reaching current densities between 17 pA/cm and 25 pA/cm at 20 for drift fields ranging from 100 V/cm to 500 V/cm. The preamplifier shows minimum intrinsic noise levels of 1.27 and 1.0 electrons r.m.s. at 20 and 30 , respectively. At room temperature ( ) the 5.9 keV and the pulser lines have 136 eV and 64 eV FWHM, respectively, corresponding to an equivalent noise charge of 7.4 electrons r.m.s.; the noise threshold is at 165 eV. The energy resolution, as measured on the pulser line, ranges from 82 eV FWHM (9.4 electrons r.m.s.) at 30C down to 29 eV FWHM (3.3 electrons r.m.s.) at 30C .
△ Less
Submitted 5 January, 2022;
originally announced January 2022.
-
First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors
Authors:
ALICE ITS project,
:,
G. Aglieri Rinella,
M. Agnello,
B. Alessandro,
F. Agnese,
R. S. Akram,
J. Alme,
E. Anderssen,
D. Andreou,
F. Antinori,
N. Apadula,
P. Atkinson,
R. Baccomi,
A. Badalà,
A. Balbino,
C. Bartels,
R. Barthel,
F. Baruffaldi,
I. Belikov,
S. Beole,
P. Becht,
A. Bhatti,
M. Bhopal,
N. Bianchi
, et al. (230 additional authors not shown)
Abstract:
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra…
▽ More
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.
△ Less
Submitted 17 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
The X/Gamma-ray Imaging Spectrometer (XGIS) on-board THESEUS: design, main characteristics, and concept of operation
Authors:
Claudio Labanti,
Lorenzo Amati,
Filippo Frontera,
Sandro Mereghetti,
José Luis Gasent-Blesa,
Christoph Tenzer,
Piotr Orleanski,
Irfan Kuvvetli,
Riccardo Campana,
Fabio Fuschino,
Luca Terenzi,
Enrico Virgilli,
Gianluca Morgante,
Mauro Orlandini,
Reginald C. Butler,
John B. Stephen,
Natalia Auricchio,
Adriano De Rosa,
Vanni Da Ronco,
Federico Evangelisti,
Michele Melchiorri,
Stefano Squerzanti,
Mauro Fiorini,
Giuseppe Bertuccio,
Filippo Mele
, et al. (36 additional authors not shown)
Abstract:
THESEUS is one of the three missions selected by ESA as fifth medium class mission (M5) candidates in its Cosmic Vision science program, currently under assessment in a phase A study with a planned launch date in 2032. THESEUS is designed to carry on-board two wide and deep sky monitoring instruments for X/gamma-ray transients detection: a wide-field soft X-ray monitor with imaging capability (Sof…
▽ More
THESEUS is one of the three missions selected by ESA as fifth medium class mission (M5) candidates in its Cosmic Vision science program, currently under assessment in a phase A study with a planned launch date in 2032. THESEUS is designed to carry on-board two wide and deep sky monitoring instruments for X/gamma-ray transients detection: a wide-field soft X-ray monitor with imaging capability (Soft X-ray Imager, SXI, 0.3 - 5 keV), a hard X-ray, partially-imaging spectroscopic instrument (X and Gamma Imaging Spectrometer, XGIS, 2 keV - 10 MeV), and an optical/near-IR telescope with both imaging and spectroscopic capability (InfraRed Telescope, IRT, 0.7 - 1.8 $μ$m). The spacecraft will be capable of performing fast repointing of the IRT to the error region provided by the monitors, thus allowing it to detect and localize the transient sources down to a few arcsec accuracy, for immediate identification and redshift determination. The prime goal of the XGIS will be to detect transient sources, with monitoring timescales down to milliseconds, both independently of, or following, up SXI detections, and identify the sources performing localisation at < 15 arcmin and characterize them over a broad energy band, thus providing also unique clues to their emission physics. The XGIS system consists of two independent but identical coded mask cameras, arranged to cover 2 steradians . The XGIS will exploit an innovative technology coupling Silicon Drift Detectors (SDD) with crystal scintillator bars and a very low-noise distributed front-end electronics (ORION ASICs), which will produce a position sensitive detection plane, with a large effective area over a huge energy band (from soft X-rays to soft gamma-rays) with timing resolution down to a few $μ$s.Here is presented an overview of the XGIS instrument design, its configuration, and capabilities.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
The XGIS instrument on-board THESEUS: the detection plane and on-board electronics
Authors:
Fabio Fuschino,
Riccardo Campana,
Claudio Labanti,
Lorenzo Amati,
Enrico Virgilli,
Luca Terenzi,
Pierluigi Bellutti,
Giuseppe Bertuccio,
Giacomo Borghi,
Francesco Ficorella,
Massimo Gandola,
Marco Grassi,
Giovanni La Rosa,
Paolo Lorenzi,
Piero Malcovati,
Filippo Mele,
Piotr Orleański,
Antonino Picciotto,
Alexandre Rachevski,
Irina Rashevskaya,
Andrea Santangelo,
Paolo Sarra,
Giuseppe Sottile,
Christoph Tenzer,
Andrea Vacchi
, et al. (10 additional authors not shown)
Abstract:
The X and Gamma Imaging Spectrometer instrument on-board the THESEUS mission (selected by ESA in the framework of the Cosmic Vision M5 launch opportunity, currently in phase A) is based on a detection plane composed of several thousands of single active elements. Each element comprises a 4.5x4.5x30 mm 3 CsI(Tl) scintillator bar, optically coupled at both ends to Silicon Drift Detectors (SDDs). The…
▽ More
The X and Gamma Imaging Spectrometer instrument on-board the THESEUS mission (selected by ESA in the framework of the Cosmic Vision M5 launch opportunity, currently in phase A) is based on a detection plane composed of several thousands of single active elements. Each element comprises a 4.5x4.5x30 mm 3 CsI(Tl) scintillator bar, optically coupled at both ends to Silicon Drift Detectors (SDDs). The SDDs acts both as photodetectors for the scintillation light and as direct X-ray sensors. In this paper the design of the XGIS detection plane is reviewed, outlining the strategic choices in terms of modularity and redundancy of the system. Results on detector-electronics prototypes are also described. Moreover, the design and development of the low-noise front-end electronics is presented, emphasizing the innovative architectural design based on custom-designed Application-Specific Integrated Circuits (ASICs).
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
An innovative architecture for a wide band transient monitor on board the HERMES nano-satellite constellation
Authors:
F. Fuschino,
R. Campana,
C. Labanti,
Y. Evangelista,
F. Fiore,
M. Gandola,
M. Grassi,
F. Mele,
F. Ambrosino,
F. Ceraudo,
E. Demenev,
M. Fiorini,
G. Morgante,
R. Piazzolla,
G. Bertuccio,
P. Malcovati,
P. Bellutti,
G. Borghi,
G. Dilillo,
M. Feroci,
F. Ficorella,
G. La Rosa,
P. Nogara,
G. Pauletta,
A. Picciotto
, et al. (13 additional authors not shown)
Abstract:
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by th…
▽ More
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by the interaction of higher energy photons in GAGG:Ce scintillators. To preserve the inherent excellent spectroscopic performances of SDDs, advanced readout electronics is necessary. In this paper, the HERMES detector architecture concept will be described in detail, as well as the specifically developed front-end ASICs (LYRA-FE and LYRA-BE) and integration solutions. The experimental performance of the integrated system composed by scintillator+SDD+LYRA ASIC will be discussed, demonstrating that the requirements of a wide energy range sensitivity, from 2 keV up to 2 MeV, are met in a compact instrument.
△ Less
Submitted 8 January, 2021;
originally announced January 2021.
-
The enhanced X-ray Timing and Polarimetry mission - eXTP
Authors:
ShuangNan Zhang,
Andrea Santangelo,
Marco Feroci,
YuPeng Xu,
FangJun Lu,
Yong Chen,
Hua Feng,
Shu Zhang,
Søren Brandt,
Margarita Hernanz,
Luca Baldini,
Enrico Bozzo,
Riccardo Campana,
Alessandra De Rosa,
YongWei Dong,
Yuri Evangelista,
Vladimir Karas,
Norbert Meidinger,
Aline Meuris,
Kirpal Nandra,
Teng Pan,
Giovanni Pareschi,
Piotr Orleanski,
QiuShi Huang,
Stephane Schanne
, et al. (125 additional authors not shown)
Abstract:
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In ad…
▽ More
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
HERMES: An ultra-wide band X and gamma-ray transient monitor on board a nano-satellite constellation
Authors:
F. Fuschino,
R. Campana,
C. Labanti,
Y. Evangelista,
M. Feroci,
L. Burderi,
F. Fiore,
F. Ambrosino,
G. Baldazzi,
P. Bellutti,
R. Bertacin,
G. Bertuccio,
G. Borghi,
D. Cirrincione,
D. Cauz,
T. Di Salvo,
F. Ficorella,
M. Fiorini,
A. Gambino,
M. Gandola,
M. Grassi,
A. Guzman,
R. Iaria,
G. La Rosa,
M. Lavagna
, et al. (27 additional authors not shown)
Abstract:
The High Energy Modular Ensemble of Satellites (HERMES) project is aimed to realize a modular X/gamma-ray monitor for transient events, to be placed on-board of a CubeSat bus. This expandable platform will achieve a significant impact on Gamma Ray Burst (GRB) science and on the detection of Gravitational Wave (GW) electromagnetic counterparts: the recent LIGO/VIRGO discoveries demonstrated that th…
▽ More
The High Energy Modular Ensemble of Satellites (HERMES) project is aimed to realize a modular X/gamma-ray monitor for transient events, to be placed on-board of a CubeSat bus. This expandable platform will achieve a significant impact on Gamma Ray Burst (GRB) science and on the detection of Gravitational Wave (GW) electromagnetic counterparts: the recent LIGO/VIRGO discoveries demonstrated that the high-energy transient sky is still a field of extreme interest. The very complex temporal variability of GRBs (up to the millisecond scale) combined with the spatial and temporal coincidence between GWs and their electromagnetic counterparts suggest that upcoming instruments require sub-ms time resolution combined with a transient localization accuracy lower than a degree. The current phase of the ongoing HERMES project is focused on the realization of a technological pathfinder with a small network (3 units) of nano-satellites to be launched in mid 2020. We will show the potential and prospects for short and medium-term development of the project, demonstrating the disrupting possibilities for scientific investigations provided by the innovative concept of a new "modular astronomy" with nano-satellites (e.g. low develo** costs, very short realization time). Finally, we will illustrate the characteristics of the HERMES Technological Pathfinder project, demonstrating how the scientific goals discussed are actually already reachable with the first nano-satellites of this constellation. The detector architecture will be described in detail, showing that the new generation of scintillators (e.g. GAGG:Ce) coupled with very performing Silicon Drift Detectors (SDD) and low noise Front-End-Electronics (FEE) are able to extend down to few keV the sensitivity band of the detector. The technical solutions for FEE, Back-End-Electronics (BEE) and Data Handling will be also described.
△ Less
Submitted 11 December, 2018; v1 submitted 6 December, 2018;
originally announced December 2018.
-
Characterization of a novel pixelated Silicon Drift Detector (PixDD) for high-throughput X-ray astrophysics
Authors:
Y. Evangelista,
F. Ambrosino,
M. Feroci,
P. Bellutti,
G. Bertuccio,
G. Borghi,
R. Campana,
M. Caselle,
D. Cirrincione,
F. Ficorella,
M. Fiorini,
F. Fuschino,
M. Gandola,
M. Grassi,
C. Labanti,
P. Malcovati,
F. Mele,
A. Morbidini,
A. Picciotto,
A. Rachevski,
I. Rashevskaya,
M. Sammartini,
G. Zampa,
N. Zampa,
N. Zorzi
, et al. (1 additional authors not shown)
Abstract:
Multi-pixel fast silicon detectors represent the enabling technology for the next generation of space-borne experiments devoted to high-resolution spectral-timing studies of low-flux compact cosmic sources. Several imaging detectors based on frame-integration have been developed as focal plane devices for X-ray space-borne missions but, when coupled to large-area concentrator X-ray optics, these d…
▽ More
Multi-pixel fast silicon detectors represent the enabling technology for the next generation of space-borne experiments devoted to high-resolution spectral-timing studies of low-flux compact cosmic sources. Several imaging detectors based on frame-integration have been developed as focal plane devices for X-ray space-borne missions but, when coupled to large-area concentrator X-ray optics, these detectors are affected by strong pile-up and dead-time effects, thus limiting the time and energy resolution as well as the overall system sensitivity. The current technological gap in the capability to realize pixelated silicon detectors for soft X-rays with fast, photon-by-photon response and nearly Fano-limited energy resolution therefore translates into the unavailability of sparse read-out sensors suitable for high throughput X-ray astronomy applications. In the framework of the ReDSoX Italian collaboration, we developed a new, sparse read-out, pixelated silicon drift detector which operates in the energy range 0.5-15 keV with nearly Fano-limited energy resolution ($\leq$150 eV FWHM @ 6 keV) at room temperature or with moderate cooling ($\sim$0 °C to +20 °C). In this paper, we present the design and the laboratory characterization of the first 16-pixel (4$\times$4) drift detector prototype (PixDD), read-out by individual ultra low-noise charge sensitive preamplifiers (SIRIO) and we discuss the future PixDD prototype developments.
△ Less
Submitted 29 August, 2018; v1 submitted 24 August, 2018;
originally announced August 2018.
-
FAMU: study of the energy dependent transfer rate $Λ_{μp \rightarrow μO}$
Authors:
FAMU Collaboration,
E. Mocchiutti,
V. Bonvicini,
M. Danailov,
E. Furlanetto,
K. S. Gadedjisso-Tossou,
D. Guffanti,
C. Pizzolotto,
A. Rachevski,
L. Stoychev,
E. Vallazza,
G. Zampa,
J. Niemela,
K. Ishida,
A. Adamczak,
G. Baccolo,
R. Benocci,
R. Bertoni,
M. Bonesini,
F. Chignoli,
M. Clemenza,
A. Curioni,
V. Maggi,
R. Mazza,
M. Moretti
, et al. (31 additional authors not shown)
Abstract:
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules,…
▽ More
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules, the $μp$ is quickly de-excited and accelerated by $\sim2/3$ of the excitation energy. The observable is the time distribution of the K-lines X-rays emitted from the $μZ$ formed by muon transfer $(μp) +Z \rightarrow (μZ)^*+p$, a reaction whose rate depends on the $μp$ kinetic energy. The maximal response, to the tuned laser wavelength, of the time distribution of X-ray from K-lines of the $(μZ)^*$ cascade indicate the resonance. During the preparatory phase of the FAMU experiment, several measurements have been performed both to validate the methodology and to prepare the best configuration of target and detectors for the spectroscopic measurement. We present here the crucial study of the energy dependence of the transfer rate from muonic hydrogen to oxygen ($Λ_{μp \rightarrow μO}$), precisely measured for the first time.
△ Less
Submitted 22 January, 2019; v1 submitted 20 August, 2018;
originally announced August 2018.
-
The Wide Field Monitor onboard the eXTP mission
Authors:
M. Hernanz,
S. Brandt,
M. Feroci,
P. Orleanski,
A. Santangelo,
S. Schanne,
Xin Wu,
J. in't Zand,
S. N. Zhang,
Y. P. Xu,
E. Bozzo,
Y. Evangelista,
J. L. Gálvez,
C. Tenzer,
F. Zwart,
F. J. Lu,
S. Zhang,
T. X. Chen,
F. Ambrosino,
A. Argan,
E. Del Monte,
C. Budtz-Jørgensen,
N. Lund,
P. Olsen,
C. Mansanet
, et al. (15 additional authors not shown)
Abstract:
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Det…
▽ More
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Wide Field Monitor (WFM). The WFM instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/WFM envisages a wide field X-ray monitor system in the 2-50 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors. The WFM will consist of 3 pairs of coded mask cameras with a total combined Field of View (FoV) of 90x180 degrees at zero response and a source localization accuracy of ~1 arcmin. In this paper we provide an overview of the WFM instrument design, including new elements with respect to the earlier LOFT configuration, and anticipated performance.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
The X-Gamma Imaging Spectrometer (XGIS) onboard THESEUS
Authors:
R. Campana,
F. Fuschino,
C. Labanti,
L. Amati,
S. Mereghetti,
M. Fiorini,
F. Frontera,
G. Baldazzi,
P. Bellutti,
G. Borghi,
I. Elmi,
Y. Evangelista,
M. Feroci,
F. Ficorella,
M. Orlandini,
A. Picciotto,
M. Marisaldi,
A. Rachevski,
M. Uslenghi,
A. Vacchi,
G. Zampa,
N. Zampa,
N. Zorzi
Abstract:
A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been designed as one of the instruments foreseen on-board the THESEUS mission proposed in response to the ESA M5 call. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm 2 Silicon Drift Detectors. Events absorbed in the Silicon layer (lower energy X rays) and events absorbed in t…
▽ More
A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been designed as one of the instruments foreseen on-board the THESEUS mission proposed in response to the ESA M5 call. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm 2 Silicon Drift Detectors. Events absorbed in the Silicon layer (lower energy X rays) and events absorbed in the scintillator crystal (higher energy X rays and Gamma-rays) are discriminated using the on-board electronics. A coded mask provides imaging capabilities at low energies, thus allowing a compact and sensitive instrument in a wide energy band (~2 keV up to ~20 MeV). The instrument design, expected performance and the characterization performed on a series of laboratory prototypes are discussed.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
The THESEUS space mission concept: science case, design and expected performances
Authors:
L. Amati,
P. O'Brien,
D. Goetz,
E. Bozzo,
C. Tenzer,
F. Frontera,
G. Ghirlanda,
C. Labanti,
J. P. Osborne,
G. Stratta,
N. Tanvir,
R. Willingale,
P. Attina,
R. Campana,
A. J. Castro-Tirado,
C. Contini,
F. Fuschino,
A. Gomboc,
R. Hudec,
P. Orleanski,
E. Renotte,
T. Rodic,
Z. Bagoly,
A. Blain,
P. Callanan
, et al. (187 additional authors not shown)
Abstract:
THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1sr) with 0.5-1 arcmin localization, an energ…
▽ More
THESEUS is a space mission concept aimed at exploiting Gamma-Ray Bursts for investigating the early Universe and at providing a substantial advancement of multi-messenger and time-domain astrophysics. These goals will be achieved through a unique combination of instruments allowing GRB and X-ray transient detection over a broad field of view (more than 1sr) with 0.5-1 arcmin localization, an energy band extending from several MeV down to 0.3 keV and high sensitivity to transient sources in the soft X-ray domain, as well as on-board prompt (few minutes) follow-up with a 0.7 m class IR telescope with both imaging and spectroscopic capabilities. THESEUS will be perfectly suited for addressing the main open issues in cosmology such as, e.g., star formation rate and metallicity evolution of the inter-stellar and intra-galactic medium up to redshift $\sim$10, signatures of Pop III stars, sources and physics of re-ionization, and the faint end of the galaxy luminosity function. In addition, it will provide unprecedented capability to monitor the X-ray variable sky, thus detecting, localizing, and identifying the electromagnetic counterparts to sources of gravitational radiation, which may be routinely detected in the late '20s / early '30s by next generation facilities like aLIGO/ aVirgo, eLISA, KAGRA, and Einstein Telescope. THESEUS will also provide powerful synergies with the next generation of multi-wavelength observatories (e.g., LSST, ELT, SKA, CTA, ATHENA).
△ Less
Submitted 27 March, 2018; v1 submitted 12 October, 2017;
originally announced October 2017.
-
First FAMU observation of muon transfer from mu-p atoms to higher-Z elements
Authors:
FAMU Collaboration,
Emiliano Mocchiutti,
Valter Bonvicini,
Rita Carbone,
Miltcho Danailov,
Elena Furlanetto,
Komlan Segbeya Gadedjisso-Tossou,
Daniele Guffanti,
Cecilia Pizzolotto,
Alexandre Rachevski,
Lyubomir Stoychev,
Erik Silvio Vallazza,
Gianluigi Zampa,
Joseph Niemela,
Katsuhiko Ishida,
Andrzej Adamczak,
Giovanni Baccolo,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Francesco Chignoli,
Massimiliano Clemenza,
Alessandro Curioni,
Valter Maggi,
Roberto Mazza
, et al. (32 additional authors not shown)
Abstract:
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Lab…
▽ More
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Laboratory, UK). The main goal of the test was the characterization of both the noise induced by the pulsed beam and the X-ray detectors. The apparatus, to some extent rudimental, has served admirably to this task. Technical results have been published that prove the validity of the choices made and pave the way for the next steps. This paper presents the results of physical relevance of measurements of the muon transfer rate to carbon dioxide, oxygen, and argon from non-thermalized excited mu-p atoms. The analysis methodology and the approach to the systematics errors are useful for the subsequent study of the transfer rate as function of the kinetic energy of the mu-p currently under way.
△ Less
Submitted 15 December, 2017; v1 submitted 10 August, 2017;
originally announced August 2017.
-
A compact and modular X and gamma-ray detector with a CsI scintillator and double-readout Silicon Drift Detectors
Authors:
R. Campana,
F. Fuschino,
C. Labanti,
M. Marisaldi,
L. Amati,
M. Fiorini,
M. Uslenghi,
G. Baldazzi,
P. Bellutti,
Y. Evangelista,
I. Elmi,
M. Feroci,
F. Ficorella,
F. Frontera,
A. Picciotto,
C. Piemonte,
A. Rachevski,
I. Rashevskaya,
L. P. Rignanese,
A. Vacchi,
G. Zampa,
N. Zampa,
N. Zorzi
Abstract:
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm2 Silicon Drift Detectors. Digital algorithms are used to discriminate between events absorbed in the Silicon layer (lower energy X rays) and events absorbed i…
▽ More
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm2 Silicon Drift Detectors. Digital algorithms are used to discriminate between events absorbed in the Silicon layer (lower energy X rays) and events absorbed in the scintillator crystal (higher energy X rays and gamma-rays). The prototype characterization is shown and the modular design for future experiments with possible astrophysical applications (e.g. for the THESEUS mission proposed for the ESA M5 call) are discussed.
△ Less
Submitted 20 April, 2017;
originally announced April 2017.
-
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Authors:
S. N. Zhang,
M. Feroci,
A. Santangelo,
Y. W. Dong,
H. Feng,
F. J. Lu,
K. Nandra,
Z. S. Wang,
S. Zhang,
E. Bozzo,
S. Brandt,
A. De Rosa,
L. J. Gou,
M. Hernanz,
M. van der Klis,
X. D. Li,
Y. Liu,
P. Orleanski,
G. Pareschi,
M. Pohl,
J. Poutanen,
J. L. Qu,
S. Schanne,
L. Stella,
P. Uttley
, et al. (160 additional authors not shown)
Abstract:
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time…
▽ More
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detection system characterization
Authors:
A. Adamczak,
G. Baccolo,
D. Bakalov,
G. Baldazzi,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
R. Campana,
R. Carbone,
T. Cervi,
F. Chignoli,
M. Clemenza,
L. Colace,
A. Curioni,
M. Danailov,
P. Danev,
I. D'Antone,
A. De,
C. De,
M. De,
M. Furini,
F. Fuschino,
K. Gadejisso-Tossou,
D. Guffanti,
A. Iaciofano
, et al. (30 additional authors not shown)
Abstract:
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the…
▽ More
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.
△ Less
Submitted 21 June, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
Authors:
S Fabiani,
M Ahangarianabhari,
G Baldazzi,
P Bellutti,
G Bertuccio,
M Bruschi,
J Bufon,
S Carrato,
A Castoldi,
G Cautero,
S Ciano,
A Cicuttin,
M L Crespo,
M Dos Santos,
M Gandola,
G Giacomini,
D Giuressi,
C Guazzoni,
R H Menk,
J Niemela,
L Olivi,
A Picciotto,
C Piemonte,
I Rashevskaya,
A Rachevski
, et al. (8 additional authors not shown)
Abstract:
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural information of materials. It operates in the energy range 2.4-27 keV by using a silicon double reflection Bragg monochromator. The fluorescence measurement is performed in place of the absorption spectroscopy when the sample transparency is too…
▽ More
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural information of materials. It operates in the energy range 2.4-27 keV by using a silicon double reflection Bragg monochromator. The fluorescence measurement is performed in place of the absorption spectroscopy when the sample transparency is too low for transmission measurements or the element to study is too diluted in the sample. We report on the development and on the preliminary tests of a new prototype detector based on Silicon Drift Detectors technology and the SIRIO ultra low noise front-end ASIC. The new system will be able to reduce drastically the time needed to perform fluorescence measurements, while kee** a short dead time and maintaining an adequate energy resolution to perform spectroscopy. The custom-made silicon sensor and the electronics are designed specifically for the beamline requirements.
△ Less
Submitted 12 January, 2016;
originally announced January 2016.
-
The effect of the displacement damage on the Charge Collection Efficiency in Silicon Drift Detectors for the LOFT satellite
Authors:
E. Del Monte,
Y. Evangelista,
E. Bozzo,
F. Cadoux,
A. Rachevski,
G. Zampa,
N. Zampa,
M. Feroci,
M. Pohl,
A. Vacchi
Abstract:
The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a three year long assessment phase as candidate for the M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science plan of the European Space Agency. During the LOFT assessment phase, we studied the displa…
▽ More
The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a three year long assessment phase as candidate for the M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science plan of the European Space Agency. During the LOFT assessment phase, we studied the displacement damage produced in the SDDs by the protons trapped in the Earth's magnetosphere. In a previous paper we discussed the effects of the Non Ionising Energy Losses from protons on the SDD leakage current. In this paper we report the measurement of the variation of Charge Collection Efficiency produced by displacement damage caused by protons and the comparison with the expected damage in orbit.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
Radiation tests of the Silicon Drift Detectors for LOFT
Authors:
E. Del Monte,
P. Azzarello,
E. Bozzo,
S. Bugiel,
S. Diebold,
Y. Evangelista,
E. Kendziorra,
F. Muleri,
E. Perinati,
A. Rachevski,
G. Zampa,
N. Zampa,
M. Feroci,
M. Pohl,
A. Santangelo,
A. Vacchi
Abstract:
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite instrumentation. In particular, we irradiated the detectors with protons (of 0.8 and 11 MeV energy) to study the increment of leakage current and the variati…
▽ More
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite instrumentation. In particular, we irradiated the detectors with protons (of 0.8 and 11 MeV energy) to study the increment of leakage current and the variation of the charge collection efficiency produced by the displacement damage, and we "bombarded" the detectors with hypervelocity dust grains to measure the effect of the debris impacts. In this paper we describe the measurements and discuss the results in the context of the LOFT mission.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
The design of the wide field monitor for LOFT
Authors:
S. Brandt,
M. Hernanz,
L. Alvarez,
A. Argan,
B. Artigues,
P. Azzarello,
D. Barret,
E. Bozzo,
Budtz-Jørgensen,
R. Campana,
A. Cros,
E. del Monte,
I. Donnarumma,
Y. Evangelista,
M. Feroci,
J. L. Galvez Sanchez,
D. Götz,
F. Hansen,
J. W. den Herder,
R. Hudec,
J. Huovelin,
D. Karelin,
S. Korpela,
N. Lund,
M. Michalska
, et al. (19 additional authors not shown)
Abstract:
LOFT (Large Observatory For x-ray Timing) is one of the ESA M3 missions selected within the Cosmic Vision program in 2011 to carry out an assessment phase study and compete for a launch opportunity in 2022-2024. The phase-A studies of all M3 missions were completed at the end of 2013. LOFT is designed to carry on-board two instruments with sensitivity in the 2-50 keV range: a 10 m 2 class Large Ar…
▽ More
LOFT (Large Observatory For x-ray Timing) is one of the ESA M3 missions selected within the Cosmic Vision program in 2011 to carry out an assessment phase study and compete for a launch opportunity in 2022-2024. The phase-A studies of all M3 missions were completed at the end of 2013. LOFT is designed to carry on-board two instruments with sensitivity in the 2-50 keV range: a 10 m 2 class Large Area Detector (LAD) with a <1° collimated FoV and a wide field monitor (WFM) making use of coded masks and providing an instantaneous coverage of more than 1/3 of the sky. The prime goal of the WFM will be to detect transient sources to be observed by the LAD. However, thanks to its unique combination of a wide field of view (FoV) and energy resolution (better than 500 eV), the WFM will be also an excellent monitoring instrument to study the long term variability of many classes of X-ray sources. The WFM consists of 10 independent and identical coded mask cameras arranged in 5 pairs to provide the desired sky coverage. We provide here an overview of the instrument design, configuration, and capabilities of the LOFT WFM. The compact and modular design of the WFM could easily make the instrument concept adaptable for other missions.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
The Large Area Detector of LOFT: the Large Observatory for X-ray Timing
Authors:
S. Zane,
D. Walton,
T. Kennedy,
M. Feroci,
J. -W. Den Herder,
M. Ahangarianabhari,
A. Argan,
P. Azzarello,
G. Baldazzi,
M. Barbera,
D. Barret,
G. Bertuccio,
P. Bodin,
E. Bozzo,
L. Bradley,
F. Cadoux,
P. Cais,
R. Campana,
J. Coker,
A. Cros,
E. Del Monte,
A. De Rosa,
S. Di Cosimo,
I. Donnarumma,
Y. Evangelista
, et al. (34 additional authors not shown)
Abstract:
LOFT (Large Observatory for X-ray Timing) is one of the five candidates that were considered by ESA as an M3 mission (with launch in 2022-2024) and has been studied during an extensive assessment phase. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -cl…
▽ More
LOFT (Large Observatory for X-ray Timing) is one of the five candidates that were considered by ESA as an M3 mission (with launch in 2022-2024) and has been studied during an extensive assessment phase. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -class instrument operating in the 2-30keV range, which holds the capability to revolutionise studies of variability from X-ray sources on the millisecond time scales. The LAD instrument has now completed the assessment phase but was not down-selected for launch. However, during the assessment, most of the trade-offs have been closed leading to a robust and well documented design that will be re- proposed in future ESA calls. In this talk, we will summarize the characteristics of the LAD design and give an overview of the expectations for the instrument capabilities.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
Hyper-velocity impact test and simulation of a double-wall shield concept for the Wide Field Monitor aboard LOFT
Authors:
E. Perinati,
M. Rott,
A. Santangelo,
S. Suchy,
C. Tenzer,
E. Del Monte,
J. -W. den Herder,
S. Diebold,
M. Feroci,
A. Rachevski,
A. Vacchi,
G. Zampa,
N. Zampa
Abstract:
The space mission LOFT (Large Observatory For X-ray Timing) was selected in 2011 by ESA as one of the candidates for the M3 launch opportunity. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM), based on Silicon Drift Detectors (SDDs). In orbit, they would be exposed to hyper-velocity impacts by environmental dust particles, which might alter the…
▽ More
The space mission LOFT (Large Observatory For X-ray Timing) was selected in 2011 by ESA as one of the candidates for the M3 launch opportunity. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM), based on Silicon Drift Detectors (SDDs). In orbit, they would be exposed to hyper-velocity impacts by environmental dust particles, which might alter the surface properties of the SDDs. In order to assess the risk posed by these events, we performed simulations in ESABASE2 and laboratory tests. Tests on SDD prototypes aimed at verifying to what extent the structural damages produced by impacts affect the SDD functionality have been performed at the Van de Graaff dust accelerator at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg. For the WFM, where we expect a rate of risky impacts notably higher than for the LAD, we designed, simulated and successfully tested at the plasma accelerator at the Technical University in Munich (TUM) a double-wall shielding configuration based on thin foils of Kapton and Polypropylene. In this paper we summarize all the assessment, focussing on the experimental test campaign at TUM.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
The Large Observatory For x-ray Timing
Authors:
M. Feroci,
J. W. den Herder,
E. Bozzo,
D. Barret,
S. Brandt,
M. Hernanz,
M. van der Klis,
M. Pohl,
A. Santangelo,
L. Stella,
A. Watts,
J. Wilms,
S. Zane,
M. Ahangarianabhari,
C. Albertus,
M. Alford,
A. Alpar,
D. Altamirano,
L. Alvarez,
L. Amati,
C. Amoros,
N. Andersson,
A. Antonelli,
A. Argan,
R. Artigue
, et al. (320 additional authors not shown)
Abstract:
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost…
▽ More
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.
△ Less
Submitted 29 August, 2014; v1 submitted 27 August, 2014;
originally announced August 2014.
-
Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors
Authors:
R. Campana,
Y. Evangelista,
F. Fuschino,
M. Ahangarianabhari,
D. Macera,
G. Bertuccio,
M. Grassi,
C. Labanti,
M. Marisaldi,
P. Malcovati,
A. Rachevski,
G. Zampa,
N. Zampa,
L. Andreani,
G. Baldazzi,
E. Del Monte,
Y. Favre,
M. Feroci,
F. Muleri,
I. Rashevskaya,
A. Vacchi,
F. Ficorella,
G. Giacomini,
A. Picciotto,
M. Zuffa
Abstract:
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end…
▽ More
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Measurement of the effect of Non Ionising Energy Losses on the leakage current of Silicon Drift Detector prototypes for the LOFT satellite
Authors:
E. Del Monte,
A. Rachevski,
G. Zampa,
N. Zampa,
P. Azzarello,
E. Bozzo,
R. Campana,
S. Diebold,
Y. Evangelista,
E. Perinati,
M. Feroci,
M. Pohl,
A. Vacchi
Abstract:
The silicon drift detectors are at the basis of the instrumentation aboard the Large Observatory For x-ray Timing (LOFT) satellite mission, which underwent a three year assessment phase within the "Cosmic Vision 2015 - 2025" long-term science plan of the European Space Agency. Silicon detectors are especially sensitive to the displacement damage, produced by the non ionising energy losses of charg…
▽ More
The silicon drift detectors are at the basis of the instrumentation aboard the Large Observatory For x-ray Timing (LOFT) satellite mission, which underwent a three year assessment phase within the "Cosmic Vision 2015 - 2025" long-term science plan of the European Space Agency. Silicon detectors are especially sensitive to the displacement damage, produced by the non ionising energy losses of charged and neutral particles, leading to an increase of the device leakage current and thus worsening the spectral resolution.
During the LOFT assessment phase, we irradiated two silicon drift detectors with a proton beam at the Proton Irradiation Facility in the accelerator of the Paul Scherrer Institute and we measured the increase in leakage current. In this paper we report the results of the irradiation and we discuss the impact of the radiation damage on the LOFT scientific performance.
△ Less
Submitted 24 June, 2014; v1 submitted 21 May, 2014;
originally announced May 2014.
-
A setup for soft proton irradiation of X-ray detectors for future astronomical space missions
Authors:
Sebastian Diebold,
Philipp Azzarello,
Ettore Del Monte,
Marco Feroci,
Josef Jochum,
Eckhard Kendziorra,
Emanuele Perinati,
Alexandre Rachevski,
Andrea Santangelo,
Christoph Tenzer,
Andrea Vacchi,
Gianluigi Zampa,
Nicola Zampa
Abstract:
Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, im**ing on silicon X-ray detectors can lead to a significant degradation of the detector performance. Especially in low earth orbits an enhancement of the soft proton flux has been found. A setup to irradiate detector…
▽ More
Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, im**ing on silicon X-ray detectors can lead to a significant degradation of the detector performance. Especially in low earth orbits an enhancement of the soft proton flux has been found. A setup to irradiate detectors with soft protons has been constructed at the Van-de-Graaff accelerator of the Physikalisches Institut of the University of Tübingen. Key advantages are a high flux uniformity over a large area, to enable irradiations of large detectors, and a monitoring system for the applied fluence, the beam uniformity, and the spectrum, that allows testing of detector prototypes in early development phases, when readout electronics are not yet available. Two irradiation campaigns have been performed so far with this setup. The irradiated detectors are silicon drift detectors, designated for the use on-board the LOFT space mission. This paper gives a description of the experimental setup and the associated monitoring system.
△ Less
Submitted 16 July, 2013;
originally announced July 2013.
-
Accelerator experiments with soft protons and hyper-velocity dust particles: application to ongoing projects of future X-ray missions
Authors:
E. Perinati,
S. Diebold,
E. Kendziorra,
A. Santangelo,
C. Tenzer,
J. Jochum,
S. Bugiel,
R. Srama,
E. Del Monte,
M. Feroci,
A. Rubini,
A. Rachevski,
G. Zampa,
N. Zampa,
I. Rashevskaya,
A. Vacchi,
P. Azzarello,
E. Bozzo,
J. -W. den Herder,
S. Zane,
S. Brandt,
M. Hernanz,
M. A. Leutenegger,
R. L. Kelley,
C. A. Kilbourne
, et al. (9 additional authors not shown)
Abstract:
We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal…
▽ More
We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal in the context of a number of ongoing space projects in order to assess the risk posed by environmental radiation and dust and qualify the adopted instrumentation with respect to possible damage or performance degradation. In this paper we focus on tests for the Silicon Drift Detectors (SDDs) used aboard the LOFT space mission. We use the Van de Graaff accelerators at the University of Tübingen and at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg, for soft proton and hyper-velocity dust tests respectively. We present the experimental set-up adopted to perform the tests, status of the activities and some very preliminary results achieved at present time.
△ Less
Submitted 14 September, 2012;
originally announced September 2012.
-
Simulations of the X-ray imaging capabilities of the Silicon Drift Detectors (SDD) for the LOFT Wide Field Monitor
Authors:
Y. Evangelista,
R. Campana,
E. Del Monte,
I. Donnarumma,
M. Feroci,
F. Muleri,
L. Pacciani,
P. Soffitta,
A. Rachevski,
A. Vacchi,
G. Zampa,
N. Zampa,
S. Suchy,
S. Brandt,
C. Budtz-Jørgensen,
M. Hernanz
Abstract:
The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionize the study of compact objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. The Large Area Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask…
▽ More
The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionize the study of compact objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. The Large Area Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask Wide Field Monitor, in charge of monitoring a large fraction of the sky potentially accessible to the LAD, to provide the history and context for the sources observed by LAD and to trigger its observations on their most interesting and extreme states. In this paper we present detailed simulations of the imaging capabilities of the Silicon Drift Detectors developed for the LOFT Wide Field Monitor detection plane. The simulations explore a large parameter space for both the detector design and the environmental conditions, allowing us to optimize the detector characteristics and demonstrating the X-ray imaging performance of the large-area SDDs in the 2-50 keV energy band.
△ Less
Submitted 7 September, 2012;
originally announced September 2012.
-
The LOFT Wide Field Monitor
Authors:
S. Brandt,
M. Hernanz,
L. Alvarez,
P. Azzarello,
D. Barret,
E. Bozzo,
Budtz-Jørgensen,
R. Campana,
E. del Monte,
I. Donnarumma,
Y. Evangelista,
M. Feroci,
J. L. Galvez Sanchez,
D. Götz,
F. Hansen,
J. W. den Herder,
R. Hudec,
J. Huovelin,
D. Karelin,
S. Korpela,
N. Lund,
P. Orleanski,
M. Pohl,
A. Rachevski,
A. Santangelo
, et al. (10 additional authors not shown)
Abstract:
LOFT (Large Observatory For x-ray Timing) is one of the four missions selected in 2011 for assessment study for the ESA M3 mission in the Cosmic Vision program, expected to be launched in 2024. The LOFT mission will carry two instruments with their prime sensitivity in the 2-30 keV range: a 10 m^2 class large area detector (LAD) with a <1° collimated field of view and a wide field monitor (WFM) in…
▽ More
LOFT (Large Observatory For x-ray Timing) is one of the four missions selected in 2011 for assessment study for the ESA M3 mission in the Cosmic Vision program, expected to be launched in 2024. The LOFT mission will carry two instruments with their prime sensitivity in the 2-30 keV range: a 10 m^2 class large area detector (LAD) with a <1° collimated field of view and a wide field monitor (WFM) instrument based on the coded mask principle, providing coverage of more than 1/3 of the sky. The LAD will provide an effective area ~20 times larger than any previous mission and will by timing studies be able to address fundamental questions about strong gravity in the vicinity of black holes and the equation of state of nuclear matter in neutron stars. The prime goal of the WFM will be to detect transient sources to be observed by the LAD. However, with its wide field of view and good energy resolution of <300 eV, the WFM will be an excellent monitoring instrument to study long term variability of many classes of X-ray sources. The sensitivity of the WFM will be 2.1 mCrab in a one day observation, and 270 mCrab in 3s in observations of in the crowded field of the Galactic Center. The high duty cycle of the instrument will make it an ideal detector of fast transient phenomena, like X-ray bursters, soft gamma repeaters, terrestrial gamma flashes, and not least provide unique capabilities in the study of gamma ray bursts. A dedicated burst alert system will enable the distribution to the community of ~100 gamma ray burst positions per year with a ~1 arcmin location accuracy within 30 s of the burst. This paper provides an overview of the design, configuration, and capabilities of the LOFT WFM instrument.
△ Less
Submitted 7 September, 2012;
originally announced September 2012.
-
A Large Area Detector proposed for the Large Observatory for X-ray Timing (LOFT)
Authors:
S. Zane,
D. Walton,
T. Kennedy,
M. Feroci,
J. -W. Den Herder,
M. Ahangarianabhari,
A. Argan,
P. Azzarello,
G. Baldazzi,
D. Barret,
G. Bertuccio,
P. Bodini,
E. Bozzo,
F. Cadoux,
P. Cais,
R. Campana,
J. Coker,
A. Cros,
E. Del Monte,
A. De Rosa,
S. Di Cosimo,
I. Donnarumma,
Y. Evangelista,
Y. Favre,
C. Feldman
, et al. (32 additional authors not shown)
Abstract:
The Large Observatory for X-ray Timing (LOFT) is one of the four candidate ESA M3 missions considered for launch in the 2022 time-frame. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. The LOFT scientific payload is composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a 10 m2-class pointed…
▽ More
The Large Observatory for X-ray Timing (LOFT) is one of the four candidate ESA M3 missions considered for launch in the 2022 time-frame. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. The LOFT scientific payload is composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a 10 m2-class pointed instrument with 20 times the collecting area of the best past timing missions (such as RXTE) over the 2-30 keV range, which holds the capability to revolutionize studies of X-ray variability down to the millisecond time scales. Its ground-breaking characteristic is a low mass per unit surface, enabling an effective area of ~10 m^2 (@10 keV) at a reasonable weight. The development of such large but light experiment, with low mass and power per unit area, is now made possible by the recent advancements in the field of large-area silicon detectors - able to time tag an X-ray photon with an accuracy <10 μs and an energy resolution of ~260 eV at 6 keV - and capillary-plate X-ray collimators. In this paper, we will summarize the characteristics of the LAD instrument and give an overview of its capabilities.
△ Less
Submitted 7 September, 2012;
originally announced September 2012.
-
LOFT: the Large Observatory For X-ray Timing
Authors:
M. Feroci,
J. W. den Herder,
E. Bozzo,
D. Barret,
S. Brandt,
M. Hernanz,
M. van der Klis,
M. Pohl,
A. Santangelo,
L. Stella,
A. Watts,
J. Wilms,
S. Zane,
M. Ahangarianabhari,
A. Alpar,
D. Altamirano,
L. Alvarez,
L. Amati,
C. Amoros,
N. Andersson,
A. Antonelli,
A. Argan,
R. Artigue,
P. Azzarello,
G. Baldazzi
, et al. (223 additional authors not shown)
Abstract:
The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neu…
▽ More
The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neutron stars, as well as the physical state of ultra-dense matter. These primary science goals will be addressed by a payload composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1 degree field of view) experiment operating in the energy range 2-50 keV, with a 10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM will operate in the same energy range as the LAD, enabling simultaneous monitoring of a few-steradian wide field of view, with an angular resolution of <5 arcmin. The LAD and WFM experiments will allow us to investigate variability from submillisecond QPO's to year-long transient outbursts. In this paper we report the current status of the project.
△ Less
Submitted 7 September, 2012;
originally announced September 2012.
-
Inclusive J/psi production in pp collisions at sqrt(s) = 2.76 TeV
Authors:
ALICE Collaboration,
B. Abelev,
J. Adam,
D. Adamova,
A. M. Adare,
M. M. Aggarwal,
G. Aglieri Rinella,
A. G. Agocs,
A. Agostinelli,
S. Aguilar Salazar,
Z. Ahammed,
A. Ahmad Masoodi,
N. Ahmad,
S. U. Ahn,
A. Akindinov,
D. Aleksandrov,
B. Alessandro,
R. Alfaro Molina,
A. Alici,
A. Alkin,
E. Almaraz Avina,
J. Alme,
T. Alt,
V. Altini,
S. Altinpinar
, et al. (948 additional authors not shown)
Abstract:
The ALICE Collaboration has measured inclusive J/psi production in pp collisions at a center of mass energy sqrt(s)=2.76 TeV at the LHC. The results presented in this Letter refer to the rapidity ranges |y|<0.9 and 2.5<y<4 and have been obtained by measuring the electron and muon pair decay channels, respectively. The integrated luminosities for the two channels are L^e_int=1.1 nb^-1 and L^mu_int=…
▽ More
The ALICE Collaboration has measured inclusive J/psi production in pp collisions at a center of mass energy sqrt(s)=2.76 TeV at the LHC. The results presented in this Letter refer to the rapidity ranges |y|<0.9 and 2.5<y<4 and have been obtained by measuring the electron and muon pair decay channels, respectively. The integrated luminosities for the two channels are L^e_int=1.1 nb^-1 and L^mu_int=19.9 nb^-1, and the corresponding signal statistics are N_J/psi^e+e-=59 +/- 14 and N_J/psi^mu+mu-=1364 +/- 53. We present dsigma_J/psi/dy for the two rapidity regions under study and, for the forward-y range, d^2sigma_J/psi/dydp_t in the transverse momentum domain 0<p_t<8 GeV/c. The results are compared with previously published results at sqrt(s)=7 TeV and with theoretical calculations.
△ Less
Submitted 6 November, 2012; v1 submitted 16 March, 2012;
originally announced March 2012.