First Calorimetric Measurement of Electron Capture in ${}^{193}$Pt with a Transition Edge Sensor
Authors:
Katrina E. Koehler,
Michael A. Famiano,
Chris J. Fontes,
Thomas W. Gorczyca,
Michael W. Rabin,
Dan R. Schmidt,
Joel N. Ullom,
Mark P. Croce
Abstract:
The neutrino mass can be extracted from a high statistics, high resolution calorimetric spectrum of electron capture in ${}^{163}$Ho. In order to better understand the shape of the calorimetric electron capture spectrum, a second isotope was measured with a close to ideal absorber-source configuration. ${}^{193}$Pt was created by irradiating a ${}^{192}$Pt-enriched platinum foil in a nuclear react…
▽ More
The neutrino mass can be extracted from a high statistics, high resolution calorimetric spectrum of electron capture in ${}^{163}$Ho. In order to better understand the shape of the calorimetric electron capture spectrum, a second isotope was measured with a close to ideal absorber-source configuration. ${}^{193}$Pt was created by irradiating a ${}^{192}$Pt-enriched platinum foil in a nuclear reactor. This Pt-in-Pt absorber was designed to have a nearly ideal absorber-source configuration. The measured ${}^{193}$Pt calorimetric electron-capture spectrum provides an independent check on the corresponding theoretical calculations, which have thus far been compared only for ${}^{163}$Ho. The first experimental and theoretically-calculated spectra from this ${}^{193}$Pt-in-Pt absorber are presented and overlaid for preliminary comparison of theory with experiment.
△ Less
Submitted 16 March, 2018;
originally announced March 2018.
-
Development of holmium-163 electron-capture spectroscopy with transition-edge sensors
Authors:
M. P. Croce,
M. W. Rabin,
V. Mocko,
G. J. Kunde,
E. R. Birnbaum,
E. M. Bond,
J. W. Engle,
A. S. Hoover,
F. M. Nortier,
A. D. Pollington,
W. A. Taylor,
N. R. Weisse-Bernstein,
L. E. Wolfsberg,
J. P. Hays-Wehle,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
T. E. Barnhart,
R. J. Nickles
Abstract:
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short half-life (4570 y) of 163Ho make it attractive for high-precision electron capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum go…
▽ More
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short half-life (4570 y) of 163Ho make it attractive for high-precision electron capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the esca** neutrino. We have developed a complete process for proton-irradiation-based isotope production, isolation, and purification of 163Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163Ho. We present our work in these areas and discuss the measured spectrum and its comparison to current theory.
△ Less
Submitted 20 October, 2015; v1 submitted 13 October, 2015;
originally announced October 2015.
-
Characterization of thin-film NbN superconductor for single-photon detection by transport measurements
Authors:
Shi-Zeng Lin,
Oscar Ayala-Valenzuela,
Ross D. McDonald,
Lev N. Bulaevskii,
Terry G. Holesinger,
Filip Ronning,
Nina R. Weisse-Bernstein,
Todd L. Williamson,
Alexander H. Mueller,
Mark A. Hoffbauer,
Michael W. Rabin,
Matthias J. Graf
Abstract:
The fabrication of high-quality thin superconducting films is essential for single-photon detectors. Their device performance is crucially affected by their material parameters, thus requiring reliable and nondestructive characterization methods after the fabrication and patterning processes. Important material parameters to know are the resistivity, superconducting transition temperature, relaxat…
▽ More
The fabrication of high-quality thin superconducting films is essential for single-photon detectors. Their device performance is crucially affected by their material parameters, thus requiring reliable and nondestructive characterization methods after the fabrication and patterning processes. Important material parameters to know are the resistivity, superconducting transition temperature, relaxation time of quasiparticles, and uniformity of patterned wires. In this work, we characterize micro-patterned thin NbN films by using transport measurements in magnetic fields. We show that from the instability of vortex motion at high currents in the flux-flow state of the $IV$ characteristic, the inelastic life time of quasiparticles can be determined to be about 2 ns. Additionally, from the depinning transition of vortices at low currents, as a function of magnetic field, the size distribution of grains can be extracted. This size distribution is found to be in agreement with the film morphology obtained from scanning electron microscopy and high-resolution transmission electron microscopy images.
△ Less
Submitted 17 May, 2013; v1 submitted 10 December, 2012;
originally announced December 2012.
-
Filters for High Rate Pulse Processing
Authors:
B. K. Alpert,
R. D. Horansky,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
A. S. Hoover,
M. W. Rabin,
J. N. Ullom
Abstract:
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform,…
▽ More
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.
△ Less
Submitted 7 December, 2012;
originally announced December 2012.