-
Review of speckle-tracking algorithms for x-ray phase contrast imaging: low dose applications
Authors:
Rafael Celestre,
Laurene Quenot,
Christopher Ninham,
Emmanuel Brun,
Luca Fardin
Abstract:
X-ray speckles have been used for a wide variety of experiments, ranging from imaging (and tomography), wavefront sensing, spatial coherence measurements all the way to x-ray photon correlation spectroscopy (XPCS) and ptychography. In the near-field regime, x-ray speckle-grains preserve shape and size under free-space propagation for a static random modulation of the illumination, which permits us…
▽ More
X-ray speckles have been used for a wide variety of experiments, ranging from imaging (and tomography), wavefront sensing, spatial coherence measurements all the way to x-ray photon correlation spectroscopy (XPCS) and ptychography. In the near-field regime, x-ray speckle-grains preserve shape and size under free-space propagation for a static random modulation of the illumination, which permits using them as wavefront markers. The introduction of an object in the modulated field will lead to a displacement of the speckles due to refraction. Retrieving the local displacements enables access to the gradient of the phase-shift induced by the sample. The numerical process to retrieve the phase information is not trivial and numerous algorithms have been developed in the past decade with various advantages and limitations. This review focuses on near-field x-ray speckle phase imaging in the differential mode as described previously, introducing the existing algorithms with their specifications and comparing their performances under various experimental conditions.
△ Less
Submitted 17 April, 2024;
originally announced April 2024.
-
Dark-field and directional dark-field on low coherence X-ray sources with random mask modulations: validation with SAXS anisotropy measurements
Authors:
Clara Magnin,
Laurene Quenot,
Sylvain Bohic,
Dan Mihai Cenda,
Manuel Fernández Martínez,
Blandine Lantz,
Bertrand Faure,
Emmanuel Brun
Abstract:
Phase Contrast Imaging (PCI), Dark-Field (DF) and Directional Dark-Field (DDF) imaging are recent X-ray imaging modalities that have demonstrated their interest by providing access to information and contrasts different from those provided by conventional absorption X-ray imaging. However, access to these two types of images is currently limited because the acquisitions require the use of coherent…
▽ More
Phase Contrast Imaging (PCI), Dark-Field (DF) and Directional Dark-Field (DDF) imaging are recent X-ray imaging modalities that have demonstrated their interest by providing access to information and contrasts different from those provided by conventional absorption X-ray imaging. However, access to these two types of images is currently limited because the acquisitions require the use of coherent sources such as synchrotron radiation or complicated optical setups to exploit the coherence requirements. This work demonstrates the possibility of efficiently performing phase contrast, dark-field and directional dark-field imaging on a low-coherence laboratory system equipped with a conventional X-ray tube, using a simple, fast and robust single-mask technique. The transfer to a low spatial coherence laboratory system was made possible by using random modulation based imaging (MoBI) and extending the low coherence system algorithm to retrieve dark-field and directional dark-field.
△ Less
Submitted 24 April, 2023; v1 submitted 20 April, 2023;
originally announced April 2023.
-
Directional dark-field implicit x-ray speckle tracking using an anisotropic-diffusion Fokker-Planck equation
Authors:
Konstantin M. Pavlov,
David M. Paganin,
Kaye S. Morgan,
Heyang,
Li,
Sebastien Berujon,
Laurène Quénot,
Emmanuel Brun
Abstract:
When a macroscopic-sized non-crystalline sample is illuminated using coherent x-ray radiation, a bifurcation of photon energy flow may occur. The coarse-grained complex refractive index of the sample may be considered to attenuate and refract the incident coherent beam, leading to a coherent component of the transmitted beam. Spatially-unresolved sample microstructure, associated with the fine-gra…
▽ More
When a macroscopic-sized non-crystalline sample is illuminated using coherent x-ray radiation, a bifurcation of photon energy flow may occur. The coarse-grained complex refractive index of the sample may be considered to attenuate and refract the incident coherent beam, leading to a coherent component of the transmitted beam. Spatially-unresolved sample microstructure, associated with the fine-grained components of the complex refractive index, introduces a diffuse component to the transmitted beam. This diffuse photon-scattering channel may be viewed in terms of position-dependent fans of ultra-small-angle x-ray scatter. These position-dependent fans, at the exit surface of the object, may under certain circumstances be approximated as having a locally-elliptical shape. By using an anisotropic-diffusion Fokker-Planck approach to model this bifurcated x-ray energy flow, we show how all three components (attenuation, refraction and locally-elliptical diffuse scatter) may be recovered. This is done via x-ray speckle tracking, in which the sample is illuminated with spatially-random x-ray fields generated by coherent illumination of a spatially-random membrane. The theory is developed, and then successfully applied to experimental x-ray data.
△ Less
Submitted 26 September, 2021; v1 submitted 22 May, 2021;
originally announced May 2021.