Microscale torsion resonators for short-range gravity experiments
Authors:
J. Manley,
C. A. Condos,
S. Schlamminger,
J. R. Pratt,
D. J. Wilson,
W. A. Terrano
Abstract:
Measuring gravitational interactions on sub-100-$μ$m length scales offers a window into physics beyond the Standard Model. However, short-range gravity experiments are limited by the ability to position sufficiently massive objects to within small separation distances. Here we propose mass-loaded silicon nitride ribbons as a platform for testing the gravitational inverse square law at separations…
▽ More
Measuring gravitational interactions on sub-100-$μ$m length scales offers a window into physics beyond the Standard Model. However, short-range gravity experiments are limited by the ability to position sufficiently massive objects to within small separation distances. Here we propose mass-loaded silicon nitride ribbons as a platform for testing the gravitational inverse square law at separations currently inaccessible with traditional torsion balances. These microscale torsion resonators benefit from low thermal noise due to strain-induced dissipation dilution while maintaining compact size (<100$\,μ$g) to allow close approach. Considering an experiment combining a 40$\,μ$g torsion resonator with a source mass of comparable size (130$\,μ$g) at separations down to 25$\,μ$m, and including limits from thermomechanical noise and systematic uncertainty, we predict these devices can set novel constraints on Yukawa interactions within the 1-100$\,μ$m range.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Nanoscale torsional dissipation dilution for quantum experiments and precision measurement
Authors:
Jon R. Pratt,
Aman R. Agrawal,
Charles A. Condos,
Christian M. Pluchar,
Stephan Schlamminger,
Dalziel J. Wilson
Abstract:
We show that torsion resonators can experience massive dissipation dilution due to nanoscale strain, and draw a connection to a century-old theory from the torsion balance community which suggests that a simple torsion ribbon is naturally soft-clamped. By disrupting a commonly held belief in the nanomechanics community, our findings invite a rethinking of strategies towards quantum experiments and…
▽ More
We show that torsion resonators can experience massive dissipation dilution due to nanoscale strain, and draw a connection to a century-old theory from the torsion balance community which suggests that a simple torsion ribbon is naturally soft-clamped. By disrupting a commonly held belief in the nanomechanics community, our findings invite a rethinking of strategies towards quantum experiments and precision measurement with nanomechanical resonators. For example, we revisit the optical lever technique for monitoring displacement, and find that the rotation of a strained nanobeam can be resolved with an imprecision smaller than the zero-point motion of its fundamental torsional mode, without the use of a cavity or interferometric stability. We also find that a strained torsion ribbon can be mass-loaded without changing its $Q$ factor. We use this strategy to engineer a chip-scale torsion balance whose resonance frequency is sensitive to micro-$g$ fluctuations of the local gravitational field. Enabling both these advances is the fabrication of high-stress Si$_3$N$_4$ nanobeams with width-to-thickness ratios of $10^4$ and the recognition that their torsional modes have $Q$ factors scaling as their width-to-thickness ratio squared, yielding $Q$ factors as high as $10^8$ and $Q$-frequency products as high as $10^{13}$ Hz.
△ Less
Submitted 15 December, 2021;
originally announced December 2021.
-
Measurement of the Planck constant at the National Institute of Standards and Technology from 2015 to 2017
Authors:
D. Haddad,
F. Seifert,
L. S. Chao,
A. Possolo,
D. B. Newell,
J. R. Pratt,
C. J. Williams,
S. Schlamminger
Abstract:
Researchers at the National Institute of Standards and Technology(NIST) have measured the value of the Planck constant to be $h =6.626\,069\,934(89)\times 10^{-34}\,$J$\,$s (relative standard uncertainty $13\times 10^{-9}$). The result is based on over 10$\,$000 weighings of masses with nominal values ranging from 0.5$\,$kg to 2$\,$kg with the Kibble balance NIST-4. The uncertainty has been reduce…
▽ More
Researchers at the National Institute of Standards and Technology(NIST) have measured the value of the Planck constant to be $h =6.626\,069\,934(89)\times 10^{-34}\,$J$\,$s (relative standard uncertainty $13\times 10^{-9}$). The result is based on over 10$\,$000 weighings of masses with nominal values ranging from 0.5$\,$kg to 2$\,$kg with the Kibble balance NIST-4. The uncertainty has been reduced by more than twofold relative to a previous determination because of three factors: (1) a much larger data set than previously available, allowing a more realistic, and smaller, Type A evaluation; (2) a more comprehensive measurement of the back action of the weighing current on the magnet by weighing masses up to 2$\,$kg, decreasing the uncertainty associated with magnet non-linearity; (3) a rigorous investigation of the dependence of the geometric factor on the coil velocity reducing the uncertainty assigned to time-dependent leakage of current in the coil.
△ Less
Submitted 8 August, 2017;
originally announced August 2017.
-
Optomechanical reference accelerometer
Authors:
Oliver Gerberding,
Felipe Guzman Cervantes,
John Melcher,
Jon R. Pratt,
Jacob M. Taylor
Abstract:
We present an optomechanical accelerometer with high dynamic range, high bandwidth and read-out noise levels below 8 $μ$g/$\sqrt{\mathrm{Hz}}$. The straightforward assembly and low cost of our device make it a prime candidate for on-site reference calibrations and autonomous navigation. We present experimental data taken with a vacuum sealed, portable prototype and deduce the achieved bias stabili…
▽ More
We present an optomechanical accelerometer with high dynamic range, high bandwidth and read-out noise levels below 8 $μ$g/$\sqrt{\mathrm{Hz}}$. The straightforward assembly and low cost of our device make it a prime candidate for on-site reference calibrations and autonomous navigation. We present experimental data taken with a vacuum sealed, portable prototype and deduce the achieved bias stability and scale factor accuracy. Additionally, we present a comprehensive model of the device physics that we use to analyze the fundamental noise sources and accuracy limitations of such devices.
△ Less
Submitted 9 April, 2015; v1 submitted 4 April, 2015;
originally announced April 2015.
-
First measurements of the flux integral with the NIST-4 watt balance
Authors:
D. Haddad,
F. Seifert,
L. S. Chao,
A. Cao,
G. Sineriz,
J. R. Pratt,
D. B. Newell,
S. Schlamminger
Abstract:
In early 2014, construction of a new watt balance, named NIST-4, has started at the National Institute of Standards and Technology (NIST). In a watt balance, the gravitational force of an unknown mass is compensated by an electromagnetic force produced by a coil in a magnet system. The electromagnetic force depends on the current in the coil and the magnetic flux integral. Most watt balances featu…
▽ More
In early 2014, construction of a new watt balance, named NIST-4, has started at the National Institute of Standards and Technology (NIST). In a watt balance, the gravitational force of an unknown mass is compensated by an electromagnetic force produced by a coil in a magnet system. The electromagnetic force depends on the current in the coil and the magnetic flux integral. Most watt balances feature an additional calibration mode, referred to as velocity mode, which allows one to measure the magnetic flux integral to high precision. In this article we describe first measurements of the flux integral in the new watt balance. We introduce measurement and data analysis techniques to assess the quality of the measurements and the adverse effects of vibrations on the instrument.
△ Less
Submitted 16 March, 2015;
originally announced March 2015.
-
A summary of the Planck constant measurements using a watt balance with a superconducting solenoid at NIST
Authors:
S. Schlamminger,
R. L. Steiner,
D. Haddad,
D. B. Newell,
F. Seifert,
L. S. Chao,
R. Liu,
E. R. Williams,
J. R. Pratt
Abstract:
Researchers at the National Institute of Standards and Technology have been using a watt balance, NIST-3, to measure the Planck constant $h$ for over ten years. Two recently published values disagree by more than one standard uncertainty. The motivation for the present manuscript is twofold. First, we correct the latest published number to take into account a recently discovered systematic error i…
▽ More
Researchers at the National Institute of Standards and Technology have been using a watt balance, NIST-3, to measure the Planck constant $h$ for over ten years. Two recently published values disagree by more than one standard uncertainty. The motivation for the present manuscript is twofold. First, we correct the latest published number to take into account a recently discovered systematic error in mass dissemination at the Bureau International des Poids et Mesures (BIPM). Second, we provide guidance on how to combine the two numbers into one final result. In order to adequately reflect the discrepancy, we added an additional systematic uncertainty to the published uncertainty budgets. The final value of $h$ measured with NIST-3 is $h = 6.626\,069\,36(37)\times 10^{-34}\,\mbox{J\,s}$. This result is $77(57) \times 10^{-9}$ fractionally higher than $h_{\mathrm{90}}$. Each number in parentheses gives the value of the standard uncertainty in the last two digits of the respective value and $h_{\mathrm{90}}$ is the conventional value of the Planck constant given by $h_{\mathrm{90}}\equiv 4 /( K_{\mathrm{J-90}}^2 R_{\mathrm{K-90}})$, where $K_{\mathrm{J-90}}$ and $R_{\mathrm{K-90}}$ denote the conventional values of the Josephson and von Klitzing constants, respectively.
△ Less
Submitted 27 January, 2015;
originally announced January 2015.
-
A determination of the local acceleration of gravity for the NIST-4 watt balance
Authors:
E. J. Leaman,
D. Haddad,
F. Seifert,
L. S. Chao,
A. Cao,
J. R. Pratt,
S. Schlamminger,
D. B. Newell
Abstract:
A new watt balance is being constructed at the National Institute of Standards and Technology (NIST) in preparation for the redefinition of the International System of Units and the realization of mass through an exact value of the Planck constant. The total relative uncertainty goal for this instrument of a few parts in $10^{8}$ requires that the local acceleration due to gravity be known at the…
▽ More
A new watt balance is being constructed at the National Institute of Standards and Technology (NIST) in preparation for the redefinition of the International System of Units and the realization of mass through an exact value of the Planck constant. The total relative uncertainty goal for this instrument of a few parts in $10^{8}$ requires that the local acceleration due to gravity be known at the location of a test mass with a relative uncertainty on the order of only a few parts in $10^{9}$. To make this determination, both the horizontal and vertical gradients of gravity must be known such that gravity may be tied from an absolute reference in the laboratory to the precise mass location. We describe the procedures used to model and measure gravity variations throughout the laboratory and give our results.
△ Less
Submitted 12 December, 2014;
originally announced December 2014.
-
A LEGO Watt Balance: An apparatus to determine a mass based on the new SI
Authors:
L. S. Chao,
S. Schlamminger,
D. B. Newell,
J. R. Pratt,
F. Seifert,
X. Zhang,
G. Sineriz,
M. Liu,
D. Haddad
Abstract:
A global effort to redefine our International System of Units (SI) is underway and the change to the new system is expected to occur in 2018. Within the newly redefined SI, the present base units will still exist but be derived from fixed numerical values of seven reference constants. More specifically, the unit of mass, the kilogram, will be realized through a fixed value of the Planck constant…
▽ More
A global effort to redefine our International System of Units (SI) is underway and the change to the new system is expected to occur in 2018. Within the newly redefined SI, the present base units will still exist but be derived from fixed numerical values of seven reference constants. More specifically, the unit of mass, the kilogram, will be realized through a fixed value of the Planck constant $h$. For instance, a watt balance can be used to realize the kilogram unit of mass within a few parts in $10^8$. Such a balance has been designed and constructed at the National Institute of Standards and Technology. For educational outreach and to demonstrate the principle, we have constructed a LEGO tabletop watt balance capable of measuring a gram size mass to 1 % relative uncertainty. This article presents the design, construction, and performance of the LEGO watt balance and its ability to determine $h$
△ Less
Submitted 7 August, 2015; v1 submitted 4 December, 2014;
originally announced December 2014.
-
A self-calibrating optomechanical force sensor with femtonewton resolution
Authors:
John Melcher,
Julian Stirling,
Felipe Guzman Cervantes,
Jon R. Pratt,
Gordon A. Shaw
Abstract:
We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3x10^6 and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration e…
▽ More
We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3x10^6 and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration enables in situ calibration of the sensor in extreme environments, such as cryogenic ultra-high vacuum. The senor technology presents a viable route to force measurements at the atomic scale with uncertainties below the percent level.
△ Less
Submitted 21 October, 2014;
originally announced October 2014.
-
Determination of the Planck constant using a watt balance with a superconducting magnet system at the National Institute of Standards and Technology
Authors:
Stephan Schlamminger,
Darine Haddad,
Frank Seifert,
Leon S Chao,
David B Newell,
Ruimin Liu,
Richard L Steiner,
Jon R Pratt
Abstract:
For the past two years, measurements have been performed with a watt balance at the National Institute of Standards and Technology (NIST) to determine the Planck constant. A detailed analysis of these measurements and their uncertainties has led to the value $h=6.626\,069\,79(30)\times 10^{-34}\,$J$\,$s. The relative standard uncertainty is $ 45\times 10^{-9}$. This result is $141\times 10^{-9}$ f…
▽ More
For the past two years, measurements have been performed with a watt balance at the National Institute of Standards and Technology (NIST) to determine the Planck constant. A detailed analysis of these measurements and their uncertainties has led to the value $h=6.626\,069\,79(30)\times 10^{-34}\,$J$\,$s. The relative standard uncertainty is $ 45\times 10^{-9}$. This result is $141\times 10^{-9}$ fractionally higher than $h_{90}$. Here $h_{90}$ is the conventional value of the Planck constant given by $h_{90}\equiv 4 /( K_{\mathrm{J-90}}^2R_{\mathrm{K-90}})$, where $K_{\mathrm{J-90}}$ and $R_{\mathrm{K-90}}$ denote the conventional values of the Josephson and von Klitzing constants, respectively.
△ Less
Submitted 24 April, 2014; v1 submitted 31 January, 2014;
originally announced January 2014.