One inch LaBr3:Ce detectors, with temperature control and improved time resolution for low energy X-rays spectroscopy
Authors:
M. Bonesini,
R. Benocci,
R. Bertoni,
A. Abba,
F. Caponio,
A. Menegolli,
M. C. Prata,
M. Rossella,
R. Rossini
Abstract:
Large area LaBr3:Ce detectors with a SiPM array readout have been developed for the FAMU experiment at RAL. The aim was to have a good energy resolution for low energy X-rays detection (around 100 keV) and good timing properties of the signal pulse. Sixteen 1" detectors and twelve 1/2" detectors have been presently installed in the FAMU experiment and are taking data since March 2023, at RIKEN RAL…
▽ More
Large area LaBr3:Ce detectors with a SiPM array readout have been developed for the FAMU experiment at RAL. The aim was to have a good energy resolution for low energy X-rays detection (around 100 keV) and good timing properties of the signal pulse. Sixteen 1" detectors and twelve 1/2" detectors have been presently installed in the FAMU experiment and are taking data since March 2023, at RIKEN RAL Port 1.
△ Less
Submitted 13 December, 2023;
originally announced December 2023.
-
Status of the detector setup for the FAMU experiment at RIKEN-RAL for a precision measurement of the Zemach radius of the proton in muonic hydrogen
Authors:
R. Rossini,
A. Adamczak,
D. Bakalov,
G. Baldazzi,
S. Banfi,
M. Baruzzo,
R. Benocci,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
H. Cabrera,
S. Carsi,
D. Cirrincione,
M. Clemenza,
L. Colace,
M. B. Danailov,
P. Danev,
A. de Bari,
C. de Vecchi,
E. Fasci,
K. S. Gadedjisso-Tossou,
R. Gaigher,
L. Gianfrani,
A. D. Hillier,
K. Ishida
, et al. (24 additional authors not shown)
Abstract:
The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition.…
▽ More
The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition. The experiment has started its data taking in July 2023. The status of the detector setup for the 2023 experimental runs, for the beam characterisation and muonic X-ray detection in the 100-200 keV energy range, is presented and discussed.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Characterisation of a low-momentum high-rate muon beam monitor for the FAMU experiment at the CNAO-XPR beam facility
Authors:
Riccardo Rossini,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Stefano Carsi,
Massimiliano Clemenza,
Antonio de Bari,
Marco Donetti,
Carlo de Vecchi,
Alessandro Menegolli,
Alessio Mereghetti,
Emiliano Mocchiutti,
Christian Petroselli,
Marco Cesare Prata,
Marco Pullia,
Gian Luca Raselli,
Massimo Rossella,
Simone Savazzi,
Ludovico Tortora,
Erik Silvio Vallazza
Abstract:
The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of t…
▽ More
The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of the FAMU experimental method. The beam monitor calibration technique and results, presented here, are meant to extract a reliable estimation of the muon flux during the FAMU data taking. These measurements were carried out at the CNAO synchrotron in Pavia, Italy, using proton beams and supported by Monte Carlo simulation of the detector in Geant4.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Improving the Time Resolution of Large-Area LaBr3:Ce Detectors with SiPM Array Readout
Authors:
M. Bonesini,
R. Bertoni,
A. Abba,
F. Caponio,
M. C. Prata,
M. Rossella
Abstract:
LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in homeland security and gamma-ray astronomy. We used 1 inch round LaBr3:Ce crystals to realize compact detectors with the SiPM array readout. The aim was a good ene…
▽ More
LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in homeland security and gamma-ray astronomy. We used 1 inch round LaBr3:Ce crystals to realize compact detectors with the SiPM array readout. The aim was a good energy resolution and a fast time response to detect low-energy X-rays around 100 keV. A natural application was found inside the FAMU experiment, at RIKEN RAL. Its aim is a precise measurement of the proton Zemach radius with im**ing muons, to contribute to the solution to the so-called proton radius puzzle. Signals to be detected are characteristic X-rays around 130 KeV. A limit for this type of detector, as compared to the ones with a photomultiplier readout, is its poorer timing characteristics due to the large capacity of the SiPM arrays used. In particular, long signal falltimes are a problem in experiments such as FAMU, where a prompt background component must be separated from a delayed one (after 600 ns) in the signal X-rays to be detected. Dedicated studies were pursued to improve the timing characteristics of the used detectors, starting from hybrid ganging of SiPM cells; then develo** a suitable zero pole circuit with a parallel ganging, where an increased overvoltage for the SiPM array was used to compensate for the signal decrease; and finally designing ad hoc electronics to split the 1 inch detector SiPM array into four quadrants, thus reducing the involved capacitances. The aim was to improve the detectors timing characteristics, especially falltime, while kee** a good FWHM energy resolution for low-energy X-ray detection.
△ Less
Submitted 28 November, 2023; v1 submitted 27 November, 2023;
originally announced November 2023.
-
Characterization of Hamamatsu 14160 series of Silicon Photo-Multipliers
Authors:
P. W. Cattaneo,
A. Menegolli,
M. C. Prata,
G. L. Raselli,
M. Rossella
Abstract:
Silicon Photo-Multipliers (SiPMs) are semiconductor-based photo-detectors with performances similar to the traditional Photo-Multiplier Tubes (PMTs). An increasing number of experiments dedicated to particle detection in colliders, accelerators, astrophysics, neutrino and rare-event physics involving scintillators are using SiPMs as photodetectors. They are gradually substituting PMTs in many appl…
▽ More
Silicon Photo-Multipliers (SiPMs) are semiconductor-based photo-detectors with performances similar to the traditional Photo-Multiplier Tubes (PMTs). An increasing number of experiments dedicated to particle detection in colliders, accelerators, astrophysics, neutrino and rare-event physics involving scintillators are using SiPMs as photodetectors. They are gradually substituting PMTs in many applications, especially where low voltages are required and high magnetic field is present. Hamamatsu Photonics K.K., one of leading producers of photo-detectors, in the last year introduced the S14160 series of SiPMs with improved performances. In this work, a characterization of these devices will be presented in terms of breakdown voltages, pulse shape, dark current and gain. Particular attention has been dedicated to the analysis of the parameters as function of temperature.
△ Less
Submitted 26 June, 2020; v1 submitted 11 June, 2020;
originally announced June 2020.
-
Beam test characterisation of a Plastic Scintillator Prototype for the space-based cosmic ray experiment HERD
Authors:
P. W. Cattaneo,
M. Pullia,
M. C. Prata,
A. Rappoldi,
M. Rossella
Abstract:
The High Energy cosmic-Radiation Detector (HERD) facility is planned to go onboard China's Space Station, planned to be operational starting in around 2025 for about 10 years. The main scientific objectives of HERD are the search for signals of dark matter annihilation products, precise cosmic electron/positron spectrum and measurements of anisotropy up to 10 TeV, precise cosmic ray spectrum and c…
▽ More
The High Energy cosmic-Radiation Detector (HERD) facility is planned to go onboard China's Space Station, planned to be operational starting in around 2025 for about 10 years. The main scientific objectives of HERD are the search for signals of dark matter annihilation products, precise cosmic electron/positron spectrum and measurements of anisotropy up to 10 TeV, precise cosmic ray spectrum and composition measurements up to the knee energy (1 PeV), and high energy $γ$-ray monitoring and survey. HERD consists of a 3D cubic crystals calorimeter (CALO) surrounded by microstrip silicon trackers (STKs) and scintillating fiber trackers (FIT) and by a Plastic Scintillator Detector (PSD) for $γ$-ray veto and ion charge measurement. A PSD prototype consisting of a scintillator tile readout by two arrays of SiPMs on opposite sides has been tested with proton and C ion beam at the CNAO (Centro Nazionale Adroterapia Oncologica) in Pavia, (Italy). Preliminary results on charge resolution are presented.
△ Less
Submitted 20 May, 2020;
originally announced May 2020.
-
Measurement of Liquid Argon Scintillation Light Properties by means of an Alpha Source placed inside the CERN 10-PMT LAr Detection System
Authors:
B. Ali-Mohammadzadeh,
M. Babicz,
V. Bellini,
A. Fava,
U. Kose,
F. Pietropaolo,
M. C. Prata,
G. L. Raselli,
F. Resnati,
M. Rossella,
C. Scagliotti,
F. Tortorici,
A. Zani
Abstract:
A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter dewar filled with liquid argon and equipped with an extendible feed-through and mechanical support for an alpha source (241Am). The position of the source can be c…
▽ More
A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter dewar filled with liquid argon and equipped with an extendible feed-through and mechanical support for an alpha source (241Am). The position of the source can be changed with respect to the PMT plane in vertical and horizontal directions. Arrays of silicon photomultiplier (SiPM) photodetectors, integrated in the source support, are used for the data acquisition trigger and to define the t0 of the light generation. PMT and SiPM signals can be recorded at different distances and different positions allowing the measurement of some of the LAr scintillation light properties. The system was studied and characterized in detail, and physics results on LAr scintillation properties are expected soon.
△ Less
Submitted 20 April, 2020;
originally announced April 2020.
-
A comparison between scintillation light Analog and Digital trigger for large volume Liquid Argon Time Projection Chambers
Authors:
O. Barnabà,
A. Menegolli,
R. Nardò,
M. Pirola,
M. C. Prata,
G. L. Raselli,
E. Romano,
M. Rossella
Abstract:
Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different approaches can be adopted to provide these detectors with an effective trigger system, relying upon analog or digital processing of signal coming from photodetec…
▽ More
Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different approaches can be adopted to provide these detectors with an effective trigger system, relying upon analog or digital processing of signal coming from photodetectors, like photomultiplier tubes or silicon photomultipliers. Each method presents advantages and drawbacks, so the implementation of a hybrid solution can benefit from both approaches. To this purpose, an innovative electronic board prototype has been designed and proposed for the use in large volume LAr-TPC detectors.
△ Less
Submitted 10 April, 2020; v1 submitted 29 February, 2020;
originally announced March 2020.
-
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector
Authors:
M. Babicz,
L. Bagby,
B. Baibussinov,
V. Bellini,
M. Bonesini,
A. Braggiotti,
S. Centro,
T. Cervi,
A. G. Cocco,
A. Falcone,
C. Farnese,
A. Fava,
F. Fichera,
D. Gibin,
A. Guglielmi,
U. Kose,
R. Mazza,
A. Menegolli,
G. Meng,
C. Montanari,
M. Nessi,
P. Picchi,
F. Pietropaolo,
M. C. Prata,
A. Rappoldi
, et al. (13 additional authors not shown)
Abstract:
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from…
▽ More
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from Hamamatsu and tested at room temperature to evaluate the performance of the devices and their compliance to detect the liquid argon scintillation light in the T600 detector. Furthermore 60 units were also characterized at cryogenic temperature, in liquid argon bath, to evaluate any parameter variation which could affect the scintillation light detection. All the tested PMTs were found to comply with the requirements of ICARUS T600 and a subset of 360 specimens was selected for the final installation in the detector.
△ Less
Submitted 4 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
An innovative technique for TPB deposition on convex window photomultiplier tubes
Authors:
M. Bonesini,
T. Cervi,
A. Falcone,
U. Kose,
R. Mazza,
A. Menegolli,
C. Montanari,
M. Nessi,
M. C. Prata,
A. Rappoldi,
G. L. Raselli,
M. Rossella,
M. Spanu,
M. Torti,
W. Vollenberg,
A. Zani
Abstract:
Tetraphenyl-butadiene (TPB) is an organic fluorescent chemical compound generally used as wavelength shifter thanks to its extremely high efficiency to convert ultra-violet photons into visible light. A common method to use TPB with detectors sensitive to visible light, such as photomultiplier tubes (PMTs), is to deposit thin layers on the device window. To obtain effective TPB layers, different p…
▽ More
Tetraphenyl-butadiene (TPB) is an organic fluorescent chemical compound generally used as wavelength shifter thanks to its extremely high efficiency to convert ultra-violet photons into visible light. A common method to use TPB with detectors sensitive to visible light, such as photomultiplier tubes (PMTs), is to deposit thin layers on the device window. To obtain effective TPB layers, different procedures can be used. In this work a specific evaporation technique adopted to coat 8 in. convex windows photomultiplier tubes is presented. It consists in evaporating TPB by means of a Knudsen cell, which allows to strictly control the process, and in a rotating sample support, which guarantees the uniformity of the deposition. Simulation results and experimental tests demonstrate the effectiveness of this evaporation technique from the point of view of deposition uniformity and light conversion efficiency.
△ Less
Submitted 5 February, 2019; v1 submitted 18 July, 2018;
originally announced July 2018.
-
Radiation Hardness tests with neutron flux on different Silicon photomultiplier devices
Authors:
P. W. Cattaneo,
T. Cervi,
A. Menegolli,
M. Oddone,
M. Prata,
M. C. Prata,
M. Rossella
Abstract:
Radiation hardness is an important requirement for solid state readout devices operating in high radiation environments common in particle physics experiments. The MEGII experiment, at PSI, Switzerland, investigates the forbidden decay $μ^+ \to \mathrm{e}^+ γ$. Exploiting the most intense muon beam of the world. A significant flux of non-thermal neutrons (kinetic energy $E_k\geq 0.5 ~MeV$) is pres…
▽ More
Radiation hardness is an important requirement for solid state readout devices operating in high radiation environments common in particle physics experiments. The MEGII experiment, at PSI, Switzerland, investigates the forbidden decay $μ^+ \to \mathrm{e}^+ γ$. Exploiting the most intense muon beam of the world. A significant flux of non-thermal neutrons (kinetic energy $E_k\geq 0.5 ~MeV$) is present in the experimental hall produced along the beamline and in the hall itself. We present the effects of neutron fluxes comparable to the MEGII expected doses on several Silicon PhotoMulitpliers (SiPMs). The tested models are: AdvanSiD ASD-NUV3S-P50 (used in MEGII experiment), AdvanSiD ASD-NUV3S-P40, AdvanSiD ASD-RGB3S-P40, Hamamatsu and Excelitas C30742-33-050-X. The neutron source is the thermal Sub-critical Multiplication complex (SM1) moderated with water, located at the University of Pavia (Italy). We report the change of SiPMs most important electric parameters: dark current, dark pulse frequency, gain, direct bias resistance, as a function of the integrated neutron fluency.
△ Less
Submitted 23 June, 2017; v1 submitted 24 May, 2017;
originally announced May 2017.
-
The construction of the Fiber-SiPM beam monitor system of the R484 and R582 experiments at the RIKEN-RAL muon facility
Authors:
M. Bonesini,
R. Bertoni,
F. Chignoli,
R. Mazza,
T. Cervi,
A. deBari,
A. Menegolli,
M. C. Prata,
M. Rossella,
L. Tortora,
R. Carbone,
E. Mocchiutti,
A. Vacchi,
E. Vallazza,
G. Zampa
Abstract:
The scintillating fiber-SiPM beam monitor detectors, designed to deliver beam informations for the R484 and R582 experiments at the high intensity, low energy pulsed muon beam at the RIKEN-RAL facility, have been successfully constructed and operated. Details on their construction and first performances in beam are reported
The scintillating fiber-SiPM beam monitor detectors, designed to deliver beam informations for the R484 and R582 experiments at the high intensity, low energy pulsed muon beam at the RIKEN-RAL facility, have been successfully constructed and operated. Details on their construction and first performances in beam are reported
△ Less
Submitted 4 March, 2017;
originally announced March 2017.