Digitization and astrometric calibration of Carte du Ciel photographic plates with Gaia~DR1
Authors:
K. Lehtinen,
T. Prusti,
J. de Bruijne,
U. Lammers,
C. F. Manara,
J. -U. Ness,
T. Markkanen,
M. Poutanen,
K. Muinonen
Abstract:
We want to study whether the astrometric and photometric accuracies obtained for the Carte du Ciel plates digitized with a commercial digital camera are high enough for scientific exploitation of the plates.
We use a digital camera Canon EOS~5Ds, with a 100mm macrolens for digitizing. We analyze six single-exposure plates and four triple-exposure plates from the Helsinki zone of Carte du Ciel (+…
▽ More
We want to study whether the astrometric and photometric accuracies obtained for the Carte du Ciel plates digitized with a commercial digital camera are high enough for scientific exploitation of the plates.
We use a digital camera Canon EOS~5Ds, with a 100mm macrolens for digitizing. We analyze six single-exposure plates and four triple-exposure plates from the Helsinki zone of Carte du Ciel (+39 degr < delta < 47 degr). Each plate is digitized using four images, with a significant central area being covered twice for quality control purposes. The astrometric calibration of the digitized images is done with the data from the Gaia TGAS (Tycho-Gaia Astrometric Solution) of the first Gaia data release (Gaia DR1), Tycho-2, HSOY (Hot Stuff for One Year), UCAC5 (USNO CCD Astrograph Catalog), and PMA catalogs.
The best astrometric accuracy is obtained with the UCAC5 reference stars. The astrometric accuracy for single-exposure plates is sigma(R.A.)=0.16" and sigma(Dec.)=0.15" expressed as a Gaussian deviation of the astrometric residuals. For triple-exposure plates the astrometric accuracy is sigma(R.A.)=0.12" and sigma(Dec.)=0.13". The 1-sigma uncertainty of photometric calibration is about 0.28 mag and 0.24 mag for single- and triple-exposure plates, respectively. We detect the photographic adjacency (Kostinsky) effect in the triple-exposure plates.
We show that accuracies at least of the level of scanning machines can be achieved with a digital camera, without any corrections for possible distortions caused by our instrumental setup. This method can be used to rapidly and inexpensively digitize and calibrate old photographic plates enabling their scientific exploitation.
△ Less
Submitted 22 May, 2018;
originally announced May 2018.
Radio interferometric observation of an asteroid occultation
Authors:
Jorma Harju,
Kimmo Lehtinen,
Jonathan Romney,
Leonid Petrov,
Mikael Granvik,
Karri Muinonen,
Uwe Bach,
Markku Poutanen
Abstract:
The occultation of the radio galaxy 0141+268 by the asteroid (372) Palma on 2017 May 15 was observed using six antennas of the Very Long Baseline Array (VLBA). The shadow of Palma crossed the VLBA station at Brewster, Washington. Owing to the wavelength used, and the size and the distance of the asteroid, a diffraction pattern in the Fraunhofer regime was observed. The measurement retrieves both t…
▽ More
The occultation of the radio galaxy 0141+268 by the asteroid (372) Palma on 2017 May 15 was observed using six antennas of the Very Long Baseline Array (VLBA). The shadow of Palma crossed the VLBA station at Brewster, Washington. Owing to the wavelength used, and the size and the distance of the asteroid, a diffraction pattern in the Fraunhofer regime was observed. The measurement retrieves both the amplitude and the phase of the diffracted electromagnetic wave. This is the first astronomical measurement of the phase shift caused by diffraction. The maximum phase shift is sensitive to the effective diameter of the asteroid. The bright spot at the shadow's center, the so called Arago--Poisson spot, is clearly detected in the amplitude time-series, and its strength is a good indicator of the closest angular distance between the center of the asteroid and the radio source. A sample of random shapes constructed using a Markov chain Monte Carlo algorithm suggests that the silhouette of Palma deviates from a perfect circle by 26+-13%. The best-fitting random shapes resemble each other, and we suggest their average approximates the shape of the silhouette at the time of the occultation. The effective diameter obtained for Palma, 192.1+-4.8 km, is in excellent agreement with recent estimates from thermal modeling of mid-infrared photometry. Finally, our computations show that because of the high positional accuracy, a single radio interferometric occultation measurement can reduce the long-term ephemeris uncertainty by an order of magnitude.
△ Less
Submitted 13 September, 2018; v1 submitted 16 April, 2018;
originally announced April 2018.