-
Near-to mid-IR spectral purity transfer with a tunable frequency comb: methanol frequency metrology over a record frequency span
Authors:
D B A Tran,
Olivier Lopez,
M Manceau,
A Goncharov,
Michel Abgrall,
H Alvarez-Martinez,
R Le Targat,
E Cantin,
P. -E Pottie,
A Amy-Klein,
B Darquié
Abstract:
We report the development and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer combining high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $μ$m metrology-grade frequency reference to a 10.3 $μ$m quantum cascade laser (QCL). The near-infrared…
▽ More
We report the development and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer combining high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $μ$m metrology-grade frequency reference to a 10.3 $μ$m quantum cascade laser (QCL). The near-infrared reference is operated at the French time/frequency metrology institute, calibrated there to primary frequency standards, and transferred to Laboratoire de Physique des Lasers via the REFIMEVE fiber network. The QCL exhibits a sub-10 --15 frequency stability from 0.1 to 10 s and its frequency is traceable to the SI with a total uncertainty better than 4 x 10 --14 after 1-s averaging time. We have developed the instrumentation allowing comb modes to be continuously tuned over 9 GHz resulting in a QCL of record spectral purity uninterruptedly tunable at the precision of the reference over an unprecedented span of 1.4 GHz. We have used our apparatus to conduct sub-Doppler spectroscopy of methanol in a multi-pass cell, demonstrating state-of-art frequency uncertainties down to the few kilohertz level. We have observed weak intensity resonances unreported so far, resolved subtle doublets never seen before and brought to light discrepancies with the HITRAN database. This demonstrates the potential of our apparatus for probing subtle internal molecular processes, building accurate spectroscopic models of polyatomic molecules of atmospheric or astrophysical interest, and carrying out precise spectroscopic tests of fundamental physics.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.
-
Roadmap towards the redefinition of the second
Authors:
N. Dimarcq,
M. Gertsvolf,
G. Mileti,
S. Bize,
C. W. Oates,
E. Peik,
D. Calonico,
T. Ido,
P. Tavella,
F. Meynadier,
G. Petit,
G. Panfilo,
J. Bartholomew,
P. Defraigne,
E. A. Donley,
P. O. Hedekvist,
I. Sesia,
M. Wouters,
P. Dube,
F. Fang,
F. Levi,
J. Lodewyck,
H. S. Margolis,
D. Newell,
S. Slyusarev
, et al. (12 additional authors not shown)
Abstract:
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the ne…
▽ More
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the necessary level of uncertainty are discussed. In addition, the mandatory criteria to be achieved before redefinition and their current fulfilment level, together with the redefinition options based on a single or on a set of transitions are described.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
-
Limitations due to residual interference in a fiber-based optical frequency reference at 1.55 $μ$m
Authors:
Karim Manamanni,
Tatiana Steshchenko,
Fabrice Wiotte,
Rodolphe Le Targat,
Michel Abgrall,
Olivier Lopez,
Étienne Cantin,
Paul-Éric Pottie,
Anne Amy-Klein,
Vincent Roncin,
Frédéric Du-Burck
Abstract:
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable…
▽ More
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable solutions for various applications. However, for high sensitivity and stability applications such as metrology, residual reflections induced by optical index inhomogeneities in connectors and fiber-coupled components leading to spurious interference significantly limit performance. We have examined the origin of the interference fringes superimposed on the detected signal and the limitations they cause to the frequency stability of the reference. The effects of temperature and beam power fluctuations are also examined. Our results show that the frequency stability is limited in the 10-13 range by the effect of interference fringes due to use of fiber components.
△ Less
Submitted 28 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Universal formalism for data sharing and processing in clock comparison networks
Authors:
Jérôme Lodewyck,
Rodolphe Le Targat,
Paul-Eric Pottie,
Erik Benkler,
Sebastian Koke,
Jochen Kronjäger
Abstract:
We present a mathematical framework adapted to the comparison of atomic clocks remotely connected by a complex network of optical or microwave links. This framework facilitates the computation of frequency ratios using a generic set of equations that are valid for a wide variety of clock architectures, making the comparison of a large number of clocks practical. This formalism suggests a generic d…
▽ More
We present a mathematical framework adapted to the comparison of atomic clocks remotely connected by a complex network of optical or microwave links. This framework facilitates the computation of frequency ratios using a generic set of equations that are valid for a wide variety of clock architectures, making the comparison of a large number of clocks practical. This formalism suggests a generic data exchange protocol that can be used in clock comparison collaborations, for which data logging and decision taking are completely local procedures, independently implemented by the participants.
△ Less
Submitted 23 November, 2020; v1 submitted 20 October, 2020;
originally announced October 2020.
-
Searching for dark matter with an unequal delay interferometer
Authors:
Etienne Savalle,
Aurelien Hees,
Florian Frank,
Etienne Cantin,
Paul-Eric Pottie,
Benjamin M. Roberts,
Lucie Cros,
Ben T. McAllister,
Peter Wolf
Abstract:
We propose a new type of experiment that compares the frequency of a clock (an ultra-stable optical cavity in this case) at time $t$ to its own frequency some time $t-T$ earlier, by "storing" the output signal (photons) in a fibre delay line. In ultra-light oscillating dark matter (DM) models, such an experiment is sensitive to coupling of DM to the standard model fields, through oscillations of t…
▽ More
We propose a new type of experiment that compares the frequency of a clock (an ultra-stable optical cavity in this case) at time $t$ to its own frequency some time $t-T$ earlier, by "storing" the output signal (photons) in a fibre delay line. In ultra-light oscillating dark matter (DM) models, such an experiment is sensitive to coupling of DM to the standard model fields, through oscillations of the cavity and fibre lengths and of the fibre refractive index. Additionally, the sensitivity is significantly enhanced around the mechanical resonances of the cavity. We present experimental result of such an experiment and report no evidence of DM for masses in the [$4.1\times 10^{-11}$, $8.3\times 10^{-10}$]~eV region. In addition, we improve constraints on the involved coupling constants by one order of magnitude in a standard galactic DM model, at the mass corresponding to the resonant frequency of our cavity. Furthermore, in the model of relaxion DM, we improve on existing constraints over the whole DM mass range by about one order of magnitude, and up to six orders of magnitude at resonance.
△ Less
Submitted 15 January, 2021; v1 submitted 12 June, 2020;
originally announced June 2020.
-
A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy
Authors:
A Cournol,
M. Manceau,
M. Pierens,
L Lecordier,
D Tran,
R. Santagata,
B. Argence,
A Goncharov,
O. Lopez,
M. Abgrall,
Y. Le Coq,
R. Le Targat,
H Alvarez Martinez,
W Lee,
D Xu,
P-E Pottie,
R Hendricks,
T Wall,
J Bieniewska,
B Sauer,
M. Tarbutt,
A. Amy-Klein,
S. Tokunaga,
B. Darquié
Abstract:
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We re…
▽ More
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We report investigations on achiral test species of which promising chiral derivatives have been synthesized.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Combining fiber Brillouin amplification with a repeater laser station for fiber-based optical frequency dissemination over 1400 km
Authors:
Sebastian Koke,
Alexander Kuhl,
Thomas Waterholter,
Sebastian M. F. Raupach,
Olivier Lopez,
Etienne Cantin,
Nicolas Quintin,
Anne Amy-Klein,
Paul-Eric Pottie,
Gesine Grosche
Abstract:
We investigate optical frequency dissemination over a 1400 km long fiber link in looped configuration over a pair of underground fibers between Braunschweig and Strasbourg. This fiber link is the first to combine fiber Brillouin amplifiers with a repeater laser station. Phase-coherent operation over more than five days is demonstrated. We analyze the repeatability of the performance over four camp…
▽ More
We investigate optical frequency dissemination over a 1400 km long fiber link in looped configuration over a pair of underground fibers between Braunschweig and Strasbourg. This fiber link is the first to combine fiber Brillouin amplifiers with a repeater laser station. Phase-coherent operation over more than five days is demonstrated. We analyze the repeatability of the performance over four campaigns and present results of 65 days in total. The weighted mean of the fractional frequency offset of the transferred optical frequency over the complete data set is $(-1.1 \pm 0.4) \times 10^{-20}$. By analyzing the stabilization signals of the two individual fibers, the correlation of the phase noise on the two fibers is shown to be >98%.
△ Less
Submitted 29 October, 2019;
originally announced November 2019.
-
First industrial-grade coherent fiber link for optical frequency standard dissemination
Authors:
F. Guillou-Camargo,
V. Ménoret,
E. Cantin,
O. Lopez,
N. Quintin,
E. Camisard,
V. Salmon,
J. -M. Le Merdy,
G. Santarelli,
A. Amy-Klein,
P. -E. Pottie,
B. Desruelle,
C. Chardonnet
Abstract:
We report on a fully bi-directional 680~km fiber link connecting two cities for which the equipment, the set up and the characterization are managed for the first time by an industrial consortium. The link uses an active telecommunication fiber network with parallel data traffic and is equipped with three repeater laser stations and four remote double bi-directional Erbium-doped fiber amplifiers.…
▽ More
We report on a fully bi-directional 680~km fiber link connecting two cities for which the equipment, the set up and the characterization are managed for the first time by an industrial consortium. The link uses an active telecommunication fiber network with parallel data traffic and is equipped with three repeater laser stations and four remote double bi-directional Erbium-doped fiber amplifiers. We report a short term stability at 1~s integration time of $5.4\times 10^{-16}$ in 0.5~Hz bandwidth and a long term stability of $1.7\times10^{-20}$ at 65\,000 s of integration time. The accuracy of the frequency transfer is evaluated as $3\times 10^{-20}$. No shift is observed within the statistical uncertainty. We show a continuous operation over 5 days with an uptime of 99.93$\%$. This performance is comparable with the state of the art coherent links established between National Metrology Institutes in Europe. It is a first step in the construction of an optical fiber network for metrology in France, which will give access to an ultra-high performance frequency standard to a wide community of scientific users.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
Two-Branch Fiber Link for International Clock Networks
Authors:
Dan Xu,
Etienne Cantin,
Florian Frank,
Nicolas Quintin,
Frédéric Meynadier,
Philip Tuckey,
Anne Amy-Klein,
Olivier Lopez,
Paul-Eric Pottie
Abstract:
We present our work on realizing two-branch fiber links enabling multiple-partner clock comparisons in Europe. We report in detail on the setup connecting two long haul links, and report for the relative frequency stability and accuracy. We report on a combined uptime of 90% for our dual-branch link during almost one month. We finally discuss the combined uncertainty contribution of the ensemble o…
▽ More
We present our work on realizing two-branch fiber links enabling multiple-partner clock comparisons in Europe. We report in detail on the setup connecting two long haul links, and report for the relative frequency stability and accuracy. We report on a combined uptime of 90% for our dual-branch link during almost one month. We finally discuss the combined uncertainty contribution of the ensemble of the link architecture to a clock comparison. We show that the frequency transfer uncertainty is 2 x 10 --19 .
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
Studying fundamental limit of optical fiber links to $10^{-21}$ level
Authors:
Dan Xu,
Won-kyu Lee,
Fabio Stefani,
Olivier Lopez,
Anne Amy-Klein,
Paul-eric Pottie
Abstract:
We present an hybrid fiber link combining effective optical frequency transfer and evaluation of performances with a self-synchronized two-way comparison. It enables us to detect the round-trip fiber noise and each of the forward and backward one-way fiber noises simultaneously. The various signals acquired with this setup allow us to study quantitatively several properties of optical fiber links.…
▽ More
We present an hybrid fiber link combining effective optical frequency transfer and evaluation of performances with a self-synchronized two-way comparison. It enables us to detect the round-trip fiber noise and each of the forward and backward one-way fiber noises simultaneously. The various signals acquired with this setup allow us to study quantitatively several properties of optical fiber links. We check the reciprocity of the accumulated noise forth and back over a bi-directional fiber to the level of $3.1(\pm 3.9)\times 10^{-20}$ based on a 160000s continuous data. We also analyze the noise correlation between two adjacent fibers and show the first experimental evidence of interferometric noise at very low Fourier frequency. We estimate redundantly and consistently the stability and accuracy of the transferred optical frequency over 43~km at $4\times 10^{-21}$ level after 16 days of integration and demonstrate that frequency comparison with instability as low as $8\times 10^{-18}$ would be achievable with uni-directional fibers in urban area.
△ Less
Submitted 26 July, 2019;
originally announced July 2019.
-
High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
Authors:
R. Santagata,
D. Tran,
B. Argence,
O. Lopez,
S. Tokunaga,
F. Wiotte,
H. Mouhamad,
A. Goncharov,
M. Abgrall,
Y. Le Coq,
H. Alvarez-Martinez,
R. Le Targat,
W. Lee,
D. Xu,
P. -E. Pottie,
B. Darquié,
A. Amy-Klein
Abstract:
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a…
▽ More
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a widely tunable ultra-narrow Quantum Cascade Laser (QCL), an optical frequency comb and a compact multipass cell. The QCL frequency is stabilized onto a comb controlled with a remote near-infrared ultra-stable laser, transferred through a fiber link. The resulting QCL frequency stability is below 10-15 from 0.1 to 10s and its frequency uncertainty of 4x10-14 is given by the remote frequency standards. Continuous tuning over ~400 MHz is reported. We use the apparatus to perform saturated absorption spectroscopy of methanol in the low-pressure multipass cell and demonstrate a statistical uncertainty at the kHz level on transition center frequencies, confirming its potential for driving the next generation technology required for precise spectroscopic measurements.
△ Less
Submitted 23 July, 2019;
originally announced July 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Novel approaches to dark-matter detection using space-time separated clocks
Authors:
Etienne Savalle,
Benjamin M. Roberts,
Florian Frank,
Paul-Eric Pottie,
Ben T. McAllister,
Conner Dailey,
Andrei Derevianko,
Peter Wolf
Abstract:
We discuss the theoretical analysis and interpretation of space-time separated clock experiments in the context of a space-time varying scalar field that is non-universally coupled to the standard model fields. If massive, such a field is a candidate for dark matter and could be detected in laboratory experiments. We show that space-time separated experiments have the potential to probe a fundamen…
▽ More
We discuss the theoretical analysis and interpretation of space-time separated clock experiments in the context of a space-time varying scalar field that is non-universally coupled to the standard model fields. If massive, such a field is a candidate for dark matter and could be detected in laboratory experiments. We show that space-time separated experiments have the potential to probe a fundamentally different parameter space from more common co-located experiments, allowing decorrelation of previously necessarily correlated parameters. Finally, we describe such a space-time separated clock experiment currently running at the Paris Observatory, and present some preliminary results as a proof of principle.
△ Less
Submitted 14 October, 2019; v1 submitted 19 February, 2019;
originally announced February 2019.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Hybrid fiber links for accurate optical frequency comparisons
Authors:
Won-Kyu Lee,
Fabio Stefani,
Anthony Bercy,
Olivier Lopez,
Anne Amy-Klein,
Paul-Eric Pottie
Abstract:
We present the first experimental demonstration over a 43-km-long urban fiber network of a local two-way optical frequency comparison, which does not require any synchronization of the measurements. It was combined with a regular active-noise compensation on another parallel fiber leading to a very reliable and robust frequency transfer. This hybrid scheme enables us to investigate the major limit…
▽ More
We present the first experimental demonstration over a 43-km-long urban fiber network of a local two-way optical frequency comparison, which does not require any synchronization of the measurements. It was combined with a regular active-noise compensation on another parallel fiber leading to a very reliable and robust frequency transfer. This hybrid scheme enables us to investigate the major limiting factors of the local two-way comparison. We analyze the contribution to the phase noise of the recovered signal by the interferometers at local and remote places. By using the ability of this set up to be injected by a single laser or two independent lasers, we measure the contribution to the long-term instability by the demodulated laser instabilities. We show that a fractional frequency instability level of $1\times10^{-20}$ at 10 000 s can be obtained with this simple setup after 43-km-long propagation in an urban area.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
Ultra-stable optical frequency dissemination on a multi-access fibre network
Authors:
Anthony Bercy,
Olivier Lopez,
Paul-Eric Pottie,
Anne Amy-Klein
Abstract:
We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two link…
▽ More
We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two links of 50-km fibre spools, the extraction being setup at the mid-point of the main link. We show that the extracted signal at the end of the secondary link exhibits fractional frequency instability of 1.4x10-15 at 1-s measurement time, almost equal to the 1.3x10-15 instability of the main link output end. The long-term instabilities are also very similar, at a level of 3-5x10-20 at 3x104-s integration time. We also show that the setting up of this extraction device, or a simpler one, at the main link input, can test the proper functioning of the noise rejection on this main link. This work is a significant step towards a robust and flexible ultra-stable network for multi-users dissemination.
△ Less
Submitted 16 March, 2016;
originally announced March 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Cascaded optical fiber link using the Internet network for remote clocks comparison
Authors:
Nicola Chiodo,
Nicolas Quintin,
Fabio Stefani,
Fabrice Wiotte,
Emilie Camisard,
Christian Chardonnet,
Giorgio Santarelli,
Anne Amy-Klein,
Paul-Eric Pottie,
Olivier Lopez
Abstract:
We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the sp…
▽ More
We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the spans. This device coherently regenerates the optical signal with the heterodyne optical phase locking of a low-noise laser diode. Optical detection of the beat-note signals for the laser lock and the link noise compensation are obtained with stable and low-noise fibered optical interferometer. We show 3.5 days of continuous operation of the noise-compensated 4-span cascaded link leading to fractional frequency instability of 4x10-16 at 1-s measurement time and 1x10-19 at 2000 s. This cascaded link was extended to 1480-km with the same performance. This work is a significant step towards a sustainable wide area ultra-stable optical frequency distribution and comparison network at a very high level of performance.
△ Less
Submitted 22 September, 2015; v1 submitted 19 September, 2015;
originally announced September 2015.
-
Frequency and time transfer for metrology and beyond using telecommunication network fibres
Authors:
Olivier Lopez,
Fabien Kéfélian,
Haifeng Jiang,
Adil Haboucha,
Anthony Bercy,
Fabio Stefani,
Bruno Chanteau,
Amale Kanj,
Daniele Rovera,
Joseph Achkar,
Christian Chardonnet,
Paul-Eric Pottie,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained.…
▽ More
The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained. We show that public telecommunication network carrying Internet data can be used to compare and distribute ultra-stable metrological signals over long distances. This novel technique paves the way for the deployment of a national and continental ultra-stable metrological optical network.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Tackling the Limits of Optical Fiber Links
Authors:
Fabio Stefani,
Olivier Lopez,
Anthony Bercy,
Won-Kyu Lee,
Christian Chardonnet,
Giorgio Santarelli,
Paul-Eric Pottie,
Anne Amy-Klein
Abstract:
We theoretically and experimentally investigate relevant noise processes arising in optical fiber links, which fundamentally limit their relative stability. We derive the unsuppressed delay noise for three configurations of optical links: two-way method, Sagnac interferometry, and actively compensated link, respectively designed for frequency comparison, rotation sensing, and frequency transfer. W…
▽ More
We theoretically and experimentally investigate relevant noise processes arising in optical fiber links, which fundamentally limit their relative stability. We derive the unsuppressed delay noise for three configurations of optical links: two-way method, Sagnac interferometry, and actively compensated link, respectively designed for frequency comparison, rotation sensing, and frequency transfer. We also consider an alternative two-way setup allowing real-time frequency comparison and demonstrate its effectiveness on a proof-of-principle experiment with a 25-km fiber spool. For these three configurations, we analyze the noise arising from uncommon fiber paths in the interferometric ensemble and design optimized interferometers. We demonstrate interferometers with very low temperature sensitivity of respectively -2.2, -0.03 and 1 fs/K. We use one of these optimized interferometers on a long haul compensated fiber link of 540km. We obtain a relative frequency stability of 3E-20 after 10,000 s of integration time.
△ Less
Submitted 8 December, 2014;
originally announced December 2014.
-
Two-Way Optical Frequency Comparisons Over 100km Telecommunication Network Fibers
Authors:
Anthony Bercy,
Fabio Stefani,
Olivier Lopez,
Christian Chardonnet,
Paul-Eric Pottie,
Anne Amy-Klein
Abstract:
By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a bi-directional scheme using a single fiber. We show that the relative stability at 1 s integration time is 7 10^18 and scales down to 5 10^21. The same level of per…
▽ More
By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a bi-directional scheme using a single fiber. We show that the relative stability at 1 s integration time is 7 10^18 and scales down to 5 10^21. The same level of performance is reached when an optical link is implemented with an active compensation of the fiber noise. We also implement a real-time two-way frequency comparison over a uni-directional telecommunication network using a pair of parallel fibers. The relative frequency stability is 10^15 at 1 s integration time and reaches 2 10^17 at 40 000 s. The fractional uncertainty of the frequency comparisons was evaluated for the best case to 2 10^20. These results open the way to accurate and high resolution frequency comparison of optical clocks over intercontinental fiber networks.
△ Less
Submitted 21 August, 2014;
originally announced August 2014.
-
In-line extraction of an ultra-stable frequency signal over an optical fiber link
Authors:
Anthony Bercy,
Saïda Guellati-Khélifa,
Fabio Stefani,
Giorgio Santarelli,
Christian Chardonnet,
Paul-Eric Pottie,
Olivier Lopez,
Anne Amy-Klein
Abstract:
We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensatio…
▽ More
We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensation. We obtain relative frequency instabilities, expressed as overlap** Allan deviation, of 8x10-16 at 1 s averaging time and a few 10-19 at 1 day. These results are at the state-of-the-art for a link using urban telecommunication fibers. We also propose an improved scheme which delivers an ultra-stable signal of higher power, in order to feed a secondary link. In-line extraction opens the way to a broad distribution of an ultra-stable frequency reference, enabling a wide range of applications beyond metrology.
△ Less
Submitted 6 February, 2014;
originally announced February 2014.
-
A two-dimensional quantum gas in a magnetic trap
Authors:
Karina Merloti,
Romain Dubessy,
Laurent Longchambon,
Aurélien Perrin,
Paul-Eric Pottie,
Vincent Lorent,
Hélène Perrin
Abstract:
We present the first experimental realization of a two-dimensional quantum gas in a purely magnetic trap dressed by a radio frequency field in the presence of gravity. The resulting potential is extremely smooth and very close to harmonic in the two-dimensional plane of confinement. We fully characterize the trap and demonstrate the confinement of a quantum gas to two dimensions. The trap geometry…
▽ More
We present the first experimental realization of a two-dimensional quantum gas in a purely magnetic trap dressed by a radio frequency field in the presence of gravity. The resulting potential is extremely smooth and very close to harmonic in the two-dimensional plane of confinement. We fully characterize the trap and demonstrate the confinement of a quantum gas to two dimensions. The trap geometry can be modified to a large extent, in particular in a dynamical way. Taking advantage of this possibility, we study the monopole and the quadrupole modes of a two-dimensional Bose gas.
△ Less
Submitted 11 March, 2013;
originally announced March 2013.
-
Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network
Authors:
Olivier Lopez,
Amale Kanj,
Paul-Eric Pottie,
Giovanni D. Rovera,
Joseph Achkar,
Christian Chardonnet,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spr…
▽ More
In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spread spectrum signals using two-way satellite time transfer modems. The results in term of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.
△ Less
Submitted 4 October, 2012; v1 submitted 21 September, 2012;
originally announced September 2012.
-
Rubidium-87 Bose-Einstein condensate in an optically plugged quadrupole trap
Authors:
Romain Dubessy,
Karina Merloti,
Laurent Longchambon,
Paul-Eric Pottie,
Thomas Liennard,
Aurélien Perrin,
Vincent Lorent,
Hélène Perrin
Abstract:
We describe an experiment to produce 87Rb Bose-Einstein condensates in an optically plugged magnetic quadrupole trap, using a blue-detuned laser. Due to the large detuning of the plug laser with respect to the atomic transition, the evaporation has to be carefully optimized in order to efficiently overcome the Majorana losses. We provide a complete theoretical and experimental study of the trappin…
▽ More
We describe an experiment to produce 87Rb Bose-Einstein condensates in an optically plugged magnetic quadrupole trap, using a blue-detuned laser. Due to the large detuning of the plug laser with respect to the atomic transition, the evaporation has to be carefully optimized in order to efficiently overcome the Majorana losses. We provide a complete theoretical and experimental study of the trap** potential at low temperatures and show that this simple model describes well our data. In particular we demonstrate methods to reliably measure the trap oscillation frequencies and the bottom frequency, based on periodic excitation of the trap** potential and on radio-frequency spectroscopy, respectively. We show that this hybrid trap can be operated in a well controlled regime that allows a reliable production of degenerate gases.
△ Less
Submitted 11 July, 2012; v1 submitted 3 December, 2011;
originally announced December 2011.
-
RF spectroscopy in a resonant RF-dressed trap
Authors:
Raghavan Kollengode Easwaran,
Laurent Longchambon,
Paul-Eric Pottie,
Vincent Lorent,
Hélène Perrin,
Barry M. Garraway
Abstract:
We study the spectroscopy of atoms dressed by a resonant radiofrequency (RF) field inside an inhomogeneous magnetic field and confined in the resulting adiabatic potential. The spectroscopic probe is a second, weak, RF field. The observed line shape is related to the temperature of the trapped cloud. We demonstrate evaporative cooling of the RF-dressed atoms by swee** the frequency of the seco…
▽ More
We study the spectroscopy of atoms dressed by a resonant radiofrequency (RF) field inside an inhomogeneous magnetic field and confined in the resulting adiabatic potential. The spectroscopic probe is a second, weak, RF field. The observed line shape is related to the temperature of the trapped cloud. We demonstrate evaporative cooling of the RF-dressed atoms by swee** the frequency of the second RF field around the Rabi frequency of the dressing field.
△ Less
Submitted 12 February, 2010;
originally announced February 2010.
-
Source laser intense pour le refroidissement du 87Rb par doublement de fréquence d'un laser fibré télécom
Authors:
Paul-Eric Pottie,
Laurent Longchambon,
Julien Delaporte,
Rémi Desbuquois,
Thomas Liennard,
Vincent Lorent,
Hélène Perrin
Abstract:
We built a frequency-doubled laser for 87Rb laser cooling, from a Telecom fiber laser. Thanks to intense technological development, telecom fiber lasers exhibit outstanding properties regarding relative intensity noise and modulation bandwidth. The enhanced doubling efficiency of periodically poled crystals allowed to obtain up to 1.8 W at 780 nm from 10 W at 1560 nm, with a simple pass configur…
▽ More
We built a frequency-doubled laser for 87Rb laser cooling, from a Telecom fiber laser. Thanks to intense technological development, telecom fiber lasers exhibit outstanding properties regarding relative intensity noise and modulation bandwidth. The enhanced doubling efficiency of periodically poled crystals allowed to obtain up to 1.8 W at 780 nm from 10 W at 1560 nm, with a simple pass configuration in a 50-mm long crystal of ppLN:MgO. This technique can also be applied at the wavelength of potassium (767 nm) (Bourdel, 2009) and could be of great interest for the realization of dipole traps.
△ Less
Submitted 12 February, 2010;
originally announced February 2010.
-
Influence of the Radio-Frequency source properties on RF-based atom traps
Authors:
Olivier Morizot,
Laurent Longchambon,
Raghavan Kollengode Easwaran,
Romain Dubessy,
Elena Knyazchyan,
Paul-Eric Pottie,
Vincent Lorent,
Hélène Perrin
Abstract:
We discuss the quality required for the RF source used to trap neutral atoms in RF-dressed potentials. We illustrate this discussion with experimental results obtained on a Bose-Einstein condensation experiment with different RF sources.
We discuss the quality required for the RF source used to trap neutral atoms in RF-dressed potentials. We illustrate this discussion with experimental results obtained on a Bose-Einstein condensation experiment with different RF sources.
△ Less
Submitted 9 April, 2008;
originally announced April 2008.
-
Trap** and cooling of rf-dressed atoms in a quadrupole magnetic field
Authors:
Olivier Morizot,
Carlos L. Garrido Alzar,
Paul-Eric Pottie,
Vincent Lorent,
Hélène Perrin
Abstract:
We observe the spontaneous evaporation of atoms confined in a bubble-like rf-dressed trap (Zobay and Garraway, 2001). The atoms are confined in a quadrupole magnetic trap and are dressed by a linearly polarized rf field. The evaporation is related to the presence of holes in the trap, at the positions where the rf coupling vanishes, due to its vectorial character. The final temperature results f…
▽ More
We observe the spontaneous evaporation of atoms confined in a bubble-like rf-dressed trap (Zobay and Garraway, 2001). The atoms are confined in a quadrupole magnetic trap and are dressed by a linearly polarized rf field. The evaporation is related to the presence of holes in the trap, at the positions where the rf coupling vanishes, due to its vectorial character. The final temperature results from a competition between residual heating and evaporation efficiency, which is controlled via the height of the holes with respect to the bottom of the trap. The experimental data are modeled by a Monte-Carlo simulation predicting a small increase in phase space density limited by the heating rate. This increase was within the phase space density determination uncertainty of the experiment.
△ Less
Submitted 18 September, 2007;
originally announced September 2007.
-
Agile low phase noise radio-frequency sine wave generator applied to experiments on ultracold atoms
Authors:
Olivier Morizot,
Julien De Lapeyre De Bellair,
Fabrice Wiotte,
Olivier Lopez,
Paul-Eric Pottie,
Hélène Perrin
Abstract:
We report on the frequency performance of a low cost (~500$) radio-frequency sine wave generator, using direct digital synthesis (DDS) and a field-programmable gate array (FPGA). The output frequency of the device may be changed dynamically to any arbitrary value ranging from DC to 10 MHz without any phase slip. Sampling effects are substantially reduced by a high sample rate, up to 1 MHz, and b…
▽ More
We report on the frequency performance of a low cost (~500$) radio-frequency sine wave generator, using direct digital synthesis (DDS) and a field-programmable gate array (FPGA). The output frequency of the device may be changed dynamically to any arbitrary value ranging from DC to 10 MHz without any phase slip. Sampling effects are substantially reduced by a high sample rate, up to 1 MHz, and by a large memory length, more than 2.10^5 samples. By using a low noise external oscillator to clock the DDS, we demonstrate a phase noise as low as that of the master clock, that is at the level of -113 dB.rad^2/Hz at 1 Hz from the carrier for an output frequency of 3.75 MHz. The device is successfully used to confine an ultracold atomic cloud of rubidium 87 in a RF-based trap, and there is no extra heating from the RF source.
△ Less
Submitted 16 April, 2007;
originally announced April 2007.