-
Analysis of concentration polarization in reverse osmosis and nanofiltration: zero-, one-, and two-dimensional models
Authors:
P. M. Biesheuvel,
S. Porada,
B. Blankert,
I. Ryzhkov,
M. Elimelech
Abstract:
Reverse osmosis and nanofiltration are membrane-based methods that remove solutes from solvent, for instance they remove salts from water (desalination). In these methods, an applied pressure is the driving force for solvent to pass the membrane, while most of the solutes are blocked. Very important in the theory of mass transport is the concentration polarization layer (CP layer), which develops…
▽ More
Reverse osmosis and nanofiltration are membrane-based methods that remove solutes from solvent, for instance they remove salts from water (desalination). In these methods, an applied pressure is the driving force for solvent to pass the membrane, while most of the solutes are blocked. Very important in the theory of mass transport is the concentration polarization layer (CP layer), which develops on the upstream side of the membrane. Because of the CP layer, the solvent flux through the membrane is reduced while leakage of solutes through the membrane increases, and both these effects must be minimized. So it is very important to understand and describe the nature of the CP layer accurately, especially to find a good estimate of the CP layer mass transfer coefficient, $k$. This is also important for the accurate characterization of membranes in a test cell geometry. We theoretically analyze the structure of the CP layer using three levels of mathematical models. First, we present a modification of an equation for $k$ by Sherwood et al. (1965) and show that it works very well in a zero dimensional model. Second, we evaluate a one-dimensional model that is more accurate, which can incorporate any equation for the flow of solvent and solutes through the membrane, and which also makes use of the new modified Sherwood equation. Finally, we fully resolve the complete channel in a two-dimensional geometry, to validate the lower-order models and to illustrate the structure of the CP layer. The overall conclusion is that for typical test cell conditions, the modified Sherwood equation can be used to characterize the CP layer, also when solvent flux through the membrane changes between inlet and outlet of the test cell. Furthermore, the one-dimensional model accurately describes solute removal (for instance water desalination) not just in a short test cell but also in a longer module.
△ Less
Submitted 21 January, 2024;
originally announced January 2024.
-
General validity of the exponential law for the effect of concentration polarization in reverse osmosis in a stirred-cell geometry, including an activity correction for 1:1 salt solutions
Authors:
P. M. Biesheuvel,
S. Porada,
I. Ryzhkov,
M. Elimelech
Abstract:
Reverse osmosis (RO) is a method to desalinate water with membranes and an applied pressure. Very important in the theory of mass transport in RO is the concentration polarization (CP) layer, which develops on the upstream side of the membrane because of a combination of salt convection and diffusion. Because of the CP-effect, the salt concentration at the membrane surface is higher than in the ch…
▽ More
Reverse osmosis (RO) is a method to desalinate water with membranes and an applied pressure. Very important in the theory of mass transport in RO is the concentration polarization (CP) layer, which develops on the upstream side of the membrane because of a combination of salt convection and diffusion. Because of the CP-effect, the salt concentration at the membrane surface is higher than in the channel, and this increases the osmotic pressure there, and thus transmembrane water flux is reduced (the osmotic pressure acts against water flux), while salt leakage through the membrane increases. So it is very important to understand and describe the CP-layer accurately. We analyze a one-dimensional geometry, which is of relevance for a typical lab-scale RO setup using small membrane coupons where the solution on the feed side of the membrane is stirred. For this geometry, the standard film layer approach is often used that assumes a stagnant film layer of a defined thickness, which however does not exist in reality. We set up a model without that assumption but including refreshment of solution because of the flow of water along the membrane due to stirring. We show that the `exponential law' for the CP-layer that is predicted by the the film model, also applies for this more accurate model. We further improve the model by including the activity coefficient of salt ions, as described by the Bjerrum theory that is based on ion-ion Coulombic interactions. We evaluate the original linearized Bjerrum theory as well as an extended Bjerrum equation that is valid up to 1.5 M salt concentration. We show how including this activity correction leads to a reduction of the diffusional driving force at high concentration, and thus the salt concentration at the membrane further increases. However, the effect can be easily included by reducing the CP-layer mass transfer coefficient by a fixed percentage.
△ Less
Submitted 30 September, 2023; v1 submitted 27 August, 2023;
originally announced August 2023.
-
A concise tutorial review of Reverse Osmosis and Electrodialysis
Authors:
P. M. Biesheuvel,
S. Porada,
M. Elimelech,
J. E. Dykstra
Abstract:
Reverse osmosis (RO) and electrodialysis (ED) are the two most important membrane technologies for water desalination and treatment. Their modes of operation and transport mechanisms are very different, but on a closer look also have many similarities. In this concise version of our tutorial review, we describe state-of-the-art theory for both processes, focusing on simple examples that are helpfu…
▽ More
Reverse osmosis (RO) and electrodialysis (ED) are the two most important membrane technologies for water desalination and treatment. Their modes of operation and transport mechanisms are very different, but on a closer look also have many similarities. In this concise version of our tutorial review, we describe state-of-the-art theory for both processes, focusing on simple examples that are helpful for the non-specialist and useful for classroom teaching. Both processes are described by the solution (SF) theory which combines ion and water transport across membranes with chemical and mechanical equilibrium at membrane/solution interfaces. We present a derivation of SF theory based on force balances on water and ions and show how the various terms, convection, diffusion, and electromigration, are derived, and how solute partitioning is implemented. Finally, we demonstrate how SF theory accurately describes the osmosis experiment where water and ions are transported in opposite directions across a membrane.
△ Less
Submitted 10 April, 2024; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Electrostatic cooling at electrolyte-electrolyte junctions
Authors:
S. Porada,
H. V. M. Hamelers,
P. M. Biesheuvel
Abstract:
Electrostatic cooling is known to occur in conductors and in porous electrodes in contact with aqueous electrolytes. Here we present for the first time evidence of electrostatic cooling at the junction of two electrolyte phases. These are, first, water containing salt, and, second, an ion-exchange membrane, which is a water-filled porous layer containing a large concentration of fixed charges. Whe…
▽ More
Electrostatic cooling is known to occur in conductors and in porous electrodes in contact with aqueous electrolytes. Here we present for the first time evidence of electrostatic cooling at the junction of two electrolyte phases. These are, first, water containing salt, and, second, an ion-exchange membrane, which is a water-filled porous layer containing a large concentration of fixed charges. When ionic current is directed through such a membrane in contact with aqueous phases on both sides, a temperature difference develops across the membrane which rapidly switches sign when the current direction is reversed. The temperature difference develops because one water-membrane junction cools down, while the other heats up. Cooling takes place when the inner product of ionic current $\textbf{I}$ and field strength $\textbf{E}$ is a negative quantity, which is possible in the electrical double layers that form on the surface of the membrane. Theory reproduces the magnitude of the effect but overestimates the rate by which the temperature difference across the membrane adjusts itself to a reversal in current.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
The difference between Faradaic and non-Faradaic electrode processes
Authors:
P. M. Biesheuvel,
S. Porada,
J. E. Dykstra
Abstract:
Both Faradaic and non-Faradaic processes can take place at an electrode. The difference between the two processes is clearly discussed in several classical sources, starting with Grahame (1952). However, later reference to charge transfer across the metal-solution interface as a defining feature of a Faradaic process, has led to ambiguities. Following Grahame, in a Faradaic process, charged partic…
▽ More
Both Faradaic and non-Faradaic processes can take place at an electrode. The difference between the two processes is clearly discussed in several classical sources, starting with Grahame (1952). However, later reference to charge transfer across the metal-solution interface as a defining feature of a Faradaic process, has led to ambiguities. Following Grahame, in a Faradaic process, charged particles transfer across the electrode, from one bulk phase to another. Thus, in a Faradaic process, after applying a constant current, the electrode charge, voltage and composition go to constant values. Instead, in a non-Faradaic (capacitive) process, charge is progressively stored. We characterize the intercalation material nickel hexacyanoferrate by two electrochemical methods and compare with theory. Data for the capacitance of this material is well described by the extended Frumkin isotherm. This data, and the correspondence with theory, demonstrates that this is a capacitive material and ion and charge storage in this material a non-Faradaic electrode process. Cyclic Voltammetry (CV) diagrams for this material have broad peaks for certain potential windows, and rectangular shapes for other conditions, both experimentally and in theoretical calculations based on a RC network model that includes how capacitance is a function of charge. Measured and predicted CV diagrams are in perfect agreement with one another. This shows that (broad) peaks in CV diagrams do not establish whether an electrode material is Faradaic or not.
△ Less
Submitted 11 January, 2021; v1 submitted 9 September, 2018;
originally announced September 2018.
-
Performance Metrics for the Objective Assessment of Capacitive Deionization Systems
Authors:
Steven A. Hawks,
Ashwin Ramachandran,
Slawomir Porada,
Patrick G. Campbell,
Matthew E. Suss,
P. M. Biesheuvel,
Juan G. Santiago,
Michael Stadermann
Abstract:
In the growing field of capacitive deionization (CDI), a number of performance metrics have emerged to describe the desalination process. Unfortunately, the separation conditions under which these metrics are measured are often not specified, resulting in optimal performance at minimal removal. Here we outline a system of performance metrics and reporting conditions that resolves this issue. Our p…
▽ More
In the growing field of capacitive deionization (CDI), a number of performance metrics have emerged to describe the desalination process. Unfortunately, the separation conditions under which these metrics are measured are often not specified, resulting in optimal performance at minimal removal. Here we outline a system of performance metrics and reporting conditions that resolves this issue. Our proposed system is based on volumetric energy consumption (Wh/m$^3$) and throughput productivity (L/h/m$^2$) reported for a specific average concentration reduction, water recovery, and feed salinity. To facilitate and rationalize comparisons between devices, materials, and operation modes, we propose a nominal standard testing condition of removing 5 mM from a 20 mM NaCl feed solution at 50% water recovery for CDI research. Using this separation, we compare the desalination performance of a flow-through electrode (fte-CDI) cell and a flow between membrane (fb-MCDI) device, showing how significantly different systems can be compared in terms of generally desirable desalination characteristics. In general, we find that performance analysis must be considered carefully so to not allow for ambiguous separation conditions or the maximization of one metric at the expense of another. Additionally, for context we discuss a number of important underlying performance indicators and cell characteristics that are not performance measures in and of themselves but can be examined to better understand differences in performance.
△ Less
Submitted 31 July, 2018; v1 submitted 23 April, 2018;
originally announced May 2018.
-
Liquid-liquid displacement in slippery liquid-infused membranes (SLIMs)
Authors:
Hanieh Bazyar,
Pengyu Lv,
Jeffery A. Wood,
Slawomir Porada,
Detlef Lohse,
Rob G. H. Lammertink
Abstract:
Liquid-infused membranes inspired by slippery liquid-infused porous surfaces (SLIPS) have been recently introduced to membrane technology. The gating mechanism of these membranes is expected to give rise to anti-fouling properties and multi-phase transport capabilities. However, the long-term retention of the infusion liquid has not yet been explored. To address this issue, we investigate the rete…
▽ More
Liquid-infused membranes inspired by slippery liquid-infused porous surfaces (SLIPS) have been recently introduced to membrane technology. The gating mechanism of these membranes is expected to give rise to anti-fouling properties and multi-phase transport capabilities. However, the long-term retention of the infusion liquid has not yet been explored. To address this issue, we investigate the retention of the infusion liquid in slippery liquid-infused membranes (SLIMs) via liquid-liquid displacement porometry (LLDP) experiments combined with microscopic observations of the displacement mechanism. Our results reveal that pores will be opened corresponding to the capillary pressure, leading to preferential flow pathways for water transport. The LLDP results further suggest the presence of liquid-lined pores in SLIM. This hypothesis is analyzed theoretically using an interfacial pore flow model. We find that the displacement patterns correspond to capillary fingering in immiscible displacement in porous media. The related physics regarding two-phase flow in porous media is used to confirm the permeation mechanism appearing in SLIMs. In order to experimentally observe liquid-liquid displacement, a microfluidic chip mimicking a porous medium is designed and a highly ramified structure with trapped infusion liquid is observed. The remaining infusion liquid is retained as pools, bridges and thin films around pillar structures in the chip, which further confirms liquid-lining. Fractal dimension analysis, along with evaluation of the fluid (non-wetting phase) saturation, further confirms that the fractal patterns correspond to capillary fingering, which is consistent with an invasion percolation with trap** (IPT) model.
△ Less
Submitted 11 April, 2018;
originally announced April 2018.
-
Capacitive Deionization -- defining a class of desalination technologies
Authors:
P. M. Biesheuvel,
M. Z. Bazant,
R. D. Cusick,
T. A. Hatton,
K. B. Hatzell,
M. C. Hatzell,
P. Liang,
S. Lin,
S. Porada,
J. G. Santiago,
K. C. Smith,
M. Stadermann,
X. Su,
X. Sun,
T. D. Waite,
A. van der Wal,
J. Yoon,
R. Zhao,
L. Zou,
M. E. Suss
Abstract:
Over the past decade, capacitive deionization (CDI) has realized a surge in attention in the field of water desalination and can now be considered as an important technology class, along with reverse osmosis and electrodialysis. While many of the recently developed technologies no longer use a mechanism that follows the strict definition of the term "capacitive", these methods nevertheless share m…
▽ More
Over the past decade, capacitive deionization (CDI) has realized a surge in attention in the field of water desalination and can now be considered as an important technology class, along with reverse osmosis and electrodialysis. While many of the recently developed technologies no longer use a mechanism that follows the strict definition of the term "capacitive", these methods nevertheless share many common elements that encourage treating them with similar metrics and analyses. Specifically, they all involve electrically driven removal of ions from a feed stream, storage in an electrode (i.e., ion electrosorption) and release, in charge/discharge cycles. Grou** all these methods in the technology class of CDI makes it possible to treat evolving new technologies in standardized terms and compare them to other technologies in the same class.
△ Less
Submitted 18 July, 2017;
originally announced September 2017.
-
Nickel Hexacyanoferrate Electrodes for Continuous Cation Intercalation Desalination of Brackish Water
Authors:
S. Porada,
A. Shrivastava,
P. Bukowska,
P. M. Biesheuvel,
K. C. Smith
Abstract:
Using porous electrodes containing nickel hexacyanoferrate (NiHCF) nanoparticles, we construct and test a device for capacitive deionization in a two flow-channel device where the intercalation electrodes are in direct contact with an anion-exchange membrane. Upon negatively charging NiHCF, cations intercalate into it and the water in its vicinity is desalinated; at the same time water in the oppo…
▽ More
Using porous electrodes containing nickel hexacyanoferrate (NiHCF) nanoparticles, we construct and test a device for capacitive deionization in a two flow-channel device where the intercalation electrodes are in direct contact with an anion-exchange membrane. Upon negatively charging NiHCF, cations intercalate into it and the water in its vicinity is desalinated; at the same time water in the opposing electrode becomes more saline upon positively charging the NiHCF in that electrode. In a cyclic process of charge and discharge, fresh water is continuously produced, alternating between the two channels in sync with the direction of applied current. We present proof-of-principle experiments of this technology for single salt solutions, where we analyze various levels of current and cycle durations. We analyze salt removal rate and energy consumption. In desalination experiments with salt mixtures we find a threefold enhancement for K$^+$ over Na$^+$-adsorption, which shows the potential of NiHCF intercalation electrodes for selective ion separation from mixed ionic solutions.
△ Less
Submitted 26 March, 2020; v1 submitted 25 December, 2016;
originally announced December 2016.
-
Attractive forces in microporous carbon electrodes for capacitive deionization
Authors:
P. M. Biesheuvel,
S. Porada,
M. Levi,
M. Z. Bazant
Abstract:
The recently developed modified Donnan (mD) model provides a simple and useful description of the electrical double layer in microporous carbon electrodes, suitable for incorporation in porous electrode theory. By postulating an attractive excess chemical potential for each ion in the micropores that is inversely proportional to the total ion concentration, we show that experimental data for capac…
▽ More
The recently developed modified Donnan (mD) model provides a simple and useful description of the electrical double layer in microporous carbon electrodes, suitable for incorporation in porous electrode theory. By postulating an attractive excess chemical potential for each ion in the micropores that is inversely proportional to the total ion concentration, we show that experimental data for capacitive deionization (CDI) can be accurately predicted over a wide range of applied voltages and salt concentrations. Since the ion spacing and Bjerrum length are each comparable to the micropore size (few nm), we postulate that the attraction results from fluctuating bare Coulomb interactions between individual ions and the metallic pore surfaces (image forces) that are not captured by meanfield theories, such as the Poisson-Boltzmann-Stern model or its mathematical limit for overlap** double layers, the Donnan model. Using reasonable estimates of the micropore permittivity and mean size (and no other fitting parameters), we propose a simple theory that predicts the attractive chemical potential inferred from experiments. As additional evidence for attractive forces, we present data for salt adsorption in uncharged microporous carbons, also predicted by the theory.
△ Less
Submitted 20 January, 2014; v1 submitted 20 December, 2013;
originally announced December 2013.