-
Design,fabrication and characterization of 8x9 n-type silicon pad array for sampling calorimetry
Authors:
Sawan,
G. Tambave,
J. L. Bouly,
O. Bourrion,
T. Chujo,
A. Das,
M. Inaba,
V. K. S. Kashyap,
C. Krug,
R. Laha,
C. Loizides,
B. Mohanty,
M. M. Mondal N. Ponchant,
K. P. Sharma,
R. Singh,
D. Tourres
Abstract:
This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out…
▽ More
This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out using the High Granularity Calorimeter Readout Chip~(HGCROC). This paper covers the Technology Computer-Aided Design (TCAD) simulations, the fabrication process, current versus voltage (IV) and capacitance versus voltage (CV) measurements, test results with a blue LED and $^{90}$Sr beta source, and neutron radiation hardness tests. IV measurements for the detector showed that 90\% of the pads had leakage current below 10~nA at full depletion voltage. Simulations predicted a breakdown voltage of 1000~V and practical tests confirmed stable operation up to 500~V without breakdown. CV measurements in the data and the simulations gave a full depletion voltage of around 50~V at a capacitance of 35~pF. LED tests verified that all detector pads responded correctly. Additionally, the 1$\times$1 cm$^2$ pads were also tested with the neutron radiations at a fluence of $5\times10^{13}$ 1~MeV~n$_{eq}$/cm$^2$.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
Beam test of n-type Silicon pad array detector at PS CERN
Authors:
Sawan,
M. Bregant,
J. L. Bouly,
O. Bourrion,
A. van den Brink,
T. Chujo,
C. Krug,
L. Kumar,
V. K. S. Kashyap,
A. Ghimouz,
M. Inaba,
T. Isidori,
C. Loizides,
B. Mohanty,
M. M. Mondal,
N. Minafra,
N. Novitzky,
N. Ponchant,
M. Rauch,
K. P. Sharma,
R. Singh,
D. Thienpont,
D. Tourres,
G. Tambave
Abstract:
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored…
▽ More
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace μ}$m thick, and high-resistivity ($\sim$7 k$Ω\thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.
△ Less
Submitted 20 March, 2024;
originally announced March 2024.
-
Prototype electronics for the silicon pad layers of the future Forward Calorimeter (FoCal) of the ALICE experiment at the LHC
Authors:
O. Bourrion,
D. Tourres,
R. Guernane,
C. Arata,
J. -L. Bouly,
N. Ponchant
Abstract:
A Forward Calorimeter (FoCal) has been proposed as part of the ALICE upgrades for data taking from 2029 onwards. The FoCal will feature a sampling electromagnetic calorimeter segmented into 110 towers supplemented by a hadron calorimeter. The electromagnetic calorimeter will be composed of 20 passive layers of tungsten absorber interleaved with 18 active layers of low-granularity silicon pad senso…
▽ More
A Forward Calorimeter (FoCal) has been proposed as part of the ALICE upgrades for data taking from 2029 onwards. The FoCal will feature a sampling electromagnetic calorimeter segmented into 110 towers supplemented by a hadron calorimeter. The electromagnetic calorimeter will be composed of 20 passive layers of tungsten absorber interleaved with 18 active layers of low-granularity silicon pad sensors and two layers of high-granularity pixel detectors. Each pad layer will be read out by 110 silicon pad sensors of 72 channels, amounting to a total of 1980 sensors. This paper describes, from front-end to back-end, the electronics developed to instrument a tower prototype composed of 18 silicon pad sensors as well as a design proposal for the full-detector readout system.
△ Less
Submitted 24 April, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
CONCERTO: Readout and control electronics
Authors:
O. Bourrion,
C. Hoarau,
J. Bounmy,
D. Tourres,
C. Vescovi J. -L. Bouly,
N. Ponchant,
A. Beelen,
M. Calvo,
A. Catalano,
J. Goupy,
G. Lagache,
J. -F. Macías-Pérez,
J. Marpaud,
A. Monfardini
Abstract:
The CONCERTO spectral-imaging instrument was installed at the Atacama Pathfinder EXperiment (APEX) 12-meter telescope in April 2021. It has been designed to look at radiation emitted by ionised carbon atoms, [CII], and use the "intensity Map**" technique to set the first constraints on the power spectrum of dusty star-forming galaxies. The instrument features two arrays of 2152 pixels constitute…
▽ More
The CONCERTO spectral-imaging instrument was installed at the Atacama Pathfinder EXperiment (APEX) 12-meter telescope in April 2021. It has been designed to look at radiation emitted by ionised carbon atoms, [CII], and use the "intensity Map**" technique to set the first constraints on the power spectrum of dusty star-forming galaxies. The instrument features two arrays of 2152 pixels constituted of Lumped Element Kinectic Inductance Detectors (LEKID) operated at cryogenic temperatures, cold optics and a fast Fourier Transform Spectrometer (FTS). To readout and operate the instrument, a newly designed electronic system hosted in five microTCA crates and composed of twelve readout boards and two control boards was designed and commissioned. The architecture and the performances are presented in this paper.
△ Less
Submitted 21 October, 2022; v1 submitted 16 August, 2022;
originally announced August 2022.
-
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Authors:
A. Catalano,
R. Adam,
P. A. R. Ade,
P.,
André,
H. Aussel,
A. Beelen,
A. Benoit,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
J. Goupy,
C. Kramer,
G. Lagache,
S. Leclercq,
J. -F. Lestrade,
J. F. Macìas-Pérez,
P. Mauskopf,
F. Mayet
, et al. (62 additional authors not shown)
Abstract:
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NI…
▽ More
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy, such as Intra Cluster Medium from intermediate to distant clusters and so for the follow-up of Planck satellite detected clusters, high redshift sources and quasars, early stages of star formation and nearby galaxies emission. We present an overview of the instrument performance as it has been evaluated at the end of the commissioning phase.
△ Less
Submitted 4 February, 2018; v1 submitted 11 December, 2017;
originally announced December 2017.
-
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Authors:
O. Bourrion,
A. Benoit,
J. L. Bouly,
J. Bouvier,
G. Bosson,
M. Calvo,
A. Catalano,
J. Goupy,
C. Li,
J. F. Macías-Pérez,
A. Monfardini,
D. Tourres,
N. Ponchant,
C. Vescovi
Abstract:
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically de…
▽ More
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.
△ Less
Submitted 25 October, 2016; v1 submitted 3 February, 2016;
originally announced February 2016.
-
Trigger and readout electronics for the STEREO experiment
Authors:
O. Bourrion,
J. L. Bouly,
J. Bouvier,
G. Bosson,
V. Helaine,
J. Lamblin,
C. Li,
F. Montanet,
J. S. Real,
T. Salagnac,
N. Ponchant,
A. Stutz,
D. Tourres,
C. Vescovi,
S. Zsoldos
Abstract:
The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomul…
▽ More
The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally, for detector performance monitoring, the electronics allow on-line calibration by driving LED synchronously with the data acquisition. This paper describes the electronics requirements, architecture and the performances achieved.
△ Less
Submitted 18 January, 2016; v1 submitted 28 October, 2015;
originally announced October 2015.