-
Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast
Authors:
James A. Pollock,
Kaye Morgan,
Linda C. P. Croton,
Emily J. Pryor,
Kelly J. Crossley,
Christopher J. Hall,
Daniel Hausermann,
Anton Maksimenko,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in imag…
▽ More
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in image resolution at equal or lower radiation levels than current clinical imaging. Propagation-based phase-contrast imaging requires minimal adaption of existing medical systems, and is well suited to lung imaging due to the strong phase gradients introduced by the lung-air material interface. Herein, propagation-based phase contrast CT is demonstrated for large animals, namely lambs, as a model for paediatric patients, using monochromatic radiation and a photon-counting detector at the Imaging and Medical Beamline of the Australian Synchrotron. Image quality, normalised against radiation dose, was optimised as a function of the beam energy and propagation distance, with the optimal conditions used to test the available image quality at very low radiation dose. Noise-limited spatial resolution was measured using Fourier ring correlation, and dosimetry was performed through Monte Carlo simulation calibrated against air kerma. The resulting CT images demonstrate superior resolution to existing high-resolution CT systems, pushing dose to the quantum limit to comply with current Australian guidelines for infant chest CT exposure (<2.5 mSv effective dose). Constituent raw projections are shown to have significant proportions of pixels with zero photon counts that would create severe information loss in conventional CT, which was prevented through phase retrieval.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Robust propagation-based phase retrieval for CT in proximity to highly attenuating objects
Authors:
J. A. Pollock,
L. C. P. Croton,
K. S. Morgan,
K. J. Crossley,
M. J. Wallace,
G. A. Buckley,
S. B. Hooper,
M. J. Kitchen
Abstract:
X-ray imaging is a fast, precise and non-invasive method of imaging which, combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via material-specific phase retrieval filters, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-mate…
▽ More
X-ray imaging is a fast, precise and non-invasive method of imaging which, combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via material-specific phase retrieval filters, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-material phantoms complicates analysis by requiring a choice of which material boundary to tune the phase retrieval. Filtering for the boundary with strongest phase contrast increases noise suppression, but with the detriment of over-blurring other interfaces, potentially obscuring small or neighbouring features and removing quantitative sample information. Additionally, regions bounded by more than one material type inherently cannot be conventionally filtered to reconstruct the whole boundary. As remedy, we present a computationally-efficient, non-iterative nor AI-mediated method for applying strong phase retrieval, whilst preserving sharp boundaries for all materials within the sample. This technique was tested on phase contrast images of a rabbit kitten brain encased by the surrounding dense skull. Using 24 keV synchrotron radiation with a 5 m propagation distance, our technique provided a 6.9-fold improvement in the signal-to-noise ratio (SNR) of brain tissue compared to the standard phase retrieval procedure, without over-smoothing the images. Simultaneous quantification of edge resolution and SNR gain was performed with an aluminium-water phantom imaged using a microfocus X-ray tube at mean energy 19.58 keV and 0.576 m effective propagation distance. Our method provided a 4.2-fold SNR boost whilst preserving the boundary resolution at 54 $\pm$ 1 $μ$m, compared to 108 $\pm$ 2 $μ$m in conventional phase retrieval.
△ Less
Submitted 29 January, 2023;
originally announced January 2023.
-
Accurate measures of regional lung air volumes from chest X-rays of small animals
Authors:
D. W. O'Connell,
K. S. Morgan,
G. Ruben,
L. C. P. Croton,
J. A. Pollock,
M. K. Croughan,
E. V. McGillick,
M. J. Wallace,
K. J. Crossley,
E. J. Pryor,
R. A. Lewis,
S. B. Hooper,
M. J. Kitchen
Abstract:
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes sho…
▽ More
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes showed a strong correlation ($R^2$=0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from X-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. This method is suitable for biomedical research studies and shows potential for clinical application.
△ Less
Submitted 7 April, 2022; v1 submitted 16 February, 2022;
originally announced February 2022.
-
Precise phase retrieval for propagation-based images using discrete mathematics
Authors:
J. A. Pollock,
K. S. Morgan,
L. C. P. Croton,
M. K. Croughan,
G. Ruben,
N. Yagi,
H. Sekiguchi,
M. J. Kitchen
Abstract:
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous…
▽ More
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous mathematics, which can result in a loss in spatial resolution in the reconstructed images. Herein we investigate how phase retrieval algorithms for propagation-based phase-contrast X-ray imaging can be rederived using discrete mathematics and result in more precise retrieval for single- and multi-material objects and for spectral image decomposition. We validate this theory through experimental measurements of spatial resolution using computed tomography (CT) reconstructions of plastic phantoms and biological tissue, using detectors with a range of imaging system point spread functions (PSFs). We demonstrate that if the PSF substantially suppresses high spatial frequencies, the potential improvement from utilising the discrete derivation is limited. However, with detectors characterised by a single pixel PSF (e.g. direct, photon-counting X-ray detectors), a significant improvement in spatial resolution can be obtained, demonstrated here at up to 17%.
△ Less
Submitted 20 September, 2022; v1 submitted 14 June, 2021;
originally announced June 2021.
-
Full field X-ray Scatter Tomography
Authors:
Gary Ruben,
Isaac Pinar,
Jeremy M. C. Brown,
Florian Schaff,
James A. Pollock,
Kelly J. Crossley,
Anton Maksimenko,
Chris Hall,
Daniel Hausermann,
Kentaro Uesugi,
Marcus J. Kitchen
Abstract:
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat.…
▽ More
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.
△ Less
Submitted 10 March, 2022; v1 submitted 16 December, 2020;
originally announced December 2020.
-
Material Decomposition using Spectral Propagation-based Phase Contrast X-ray Imaging
Authors:
Florian Schaff,
Kaye S. Morgan,
James A. Pollock,
Linda C. P. Croton,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly atten…
▽ More
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly attenuating features and separate them from overlying objects in radiography. We derive an algorithm that performs both tasks simultaneously and verify it against numerical simulations and experimental measurements of ideal two-component samples composed of pure aluminium and poly(methyl methacrylate). Additionally, we showcase first imaging results of a rabbit kitten's lung. The attenuation signal of a thorax, in particular, is dominated by the strongly attenuating bones of the ribcage, which combined with the weak soft tissue signal make it difficult to visualise the fine anatomical structures across the whole lung. In all cases, clean material decomposition was achieved, without residual phase contrast effects, from which we generate an un-obstructed image of the lung, free of bones. Spectral propagation-based phase contrast imaging has the potential to be a valuable tool, not only in future lung research, but also in other systems for which phase contrast imaging in combination with material decomposition proves to be advantageous.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.