Skip to main content

Showing 1–41 of 41 results for author: Pollmann, T

.
  1. arXiv:2406.18597  [pdf, other

    physics.ins-det hep-ex

    Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data

    Authors: The DEAP Collaboration, P. Adhikari, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, D. J. Auty, M. Batygov, B. Beltran, C. E. Bina, W. Bonivento, M. G. Boulay, J. F. Bueno, B. Cai, M. Cárdenas-Montes, S. Choudhary, B. T. Cleveland, R. Crampton, S. Daugherty, P. DelGobbo, P. Di Stefano, G. Dolganov, L. Doria, F. A. Duncan, M. Dunford, E. Ellingwood , et al. (73 additional authors not shown)

    Abstract: The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace… ▽ More

    Submitted 12 June, 2024; originally announced June 2024.

    Comments: Submitted to Eur. Phys. J. C

  2. arXiv:2406.13638  [pdf, other

    physics.data-an astro-ph.IM hep-ex physics.ins-det

    XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, D. Antón Martin, F. Arneodo, L. Baudis, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, K. Boese, A. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, A. P. Cimental Chávez, A. P. Colijn, J. Conrad, J. J. Cuenca-García, V. D'Andrea , et al. (139 additional authors not shown)

    Abstract: The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 t… ▽ More

    Submitted 19 June, 2024; originally announced June 2024.

    Comments: 20 pages, 10 figures

  3. arXiv:2403.14878  [pdf, other

    hep-ex physics.ins-det

    Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors

    Authors: E. Aprile, J. Aalbers, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, G. Bruno, R. Budnik, T. K. Bui, J. M. R. Cardoso, A. P. Cimental Chavez, A. P. Colijn, J. Conrad , et al. (142 additional authors not shown)

    Abstract: This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity… ▽ More

    Submitted 19 June, 2024; v1 submitted 21 March, 2024; originally announced March 2024.

    Comments: 17 pages, 19 figures

  4. arXiv:2402.10446  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The XENONnT Dark Matter Experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, M. Balata, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui , et al. (170 additional authors not shown)

    Abstract: The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in… ▽ More

    Submitted 15 February, 2024; originally announced February 2024.

    Comments: 32 pages, 19 figures

  5. arXiv:2309.11996  [pdf, other

    hep-ex physics.ins-det

    Design and performance of the field cage for the XENONnT experiment

    Authors: E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso, D. Cichon , et al. (139 additional authors not shown)

    Abstract: The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to t… ▽ More

    Submitted 21 September, 2023; originally announced September 2023.

    Journal ref: Eur. Phys. J. C 84, 138 (2024)

  6. arXiv:2306.16340  [pdf, other

    physics.ins-det

    Cosmogenic background simulations for the DARWIN observatory at different underground locations

    Authors: M. Adrover, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, B. Antunovic, E. Aprile, M. Babicz, D. Bajpai, E. Barberio, L. Baudis, M. Bazyk, N. Bell, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, C. Boehm, A. Breskin, E. J. Brookes, A. Brown, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso , et al. (158 additional authors not shown)

    Abstract: Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are… ▽ More

    Submitted 28 June, 2023; originally announced June 2023.

  7. arXiv:2306.11871  [pdf, other

    hep-ex physics.ins-det

    Search for events in XENON1T associated with Gravitational Waves

    Authors: XENON Collaboration, E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antoń Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso , et al. (138 additional authors not shown)

    Abstract: We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW1… ▽ More

    Submitted 27 October, 2023; v1 submitted 20 June, 2023; originally announced June 2023.

  8. arXiv:2304.10931  [pdf, other

    hep-ex physics.ins-det

    Searching for Heavy Dark Matter near the Planck Mass with XENON1T

    Authors: E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso, D. Cichon , et al. (142 additional authors not shown)

    Abstract: Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.… ▽ More

    Submitted 21 April, 2023; originally announced April 2023.

    Comments: 7 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 130, 261002 (2023)

  9. Detector signal characterization with a Bayesian network in XENONnT

    Authors: XENON Collaboration, E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso , et al. (142 additional authors not shown)

    Abstract: We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ioniz… ▽ More

    Submitted 26 July, 2023; v1 submitted 11 April, 2023; originally announced April 2023.

    Comments: 11 pages, 8 figures

    Journal ref: Phys. Rev. D 108, 012016 (2023)

  10. arXiv:2302.14639  [pdf, other

    physics.ins-det hep-ex

    Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

    Authors: P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, G. R. Araujo, D. J. Auty, M. Baldwin, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen , et al. (125 additional authors not shown)

    Abstract: The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi… ▽ More

    Submitted 10 October, 2023; v1 submitted 27 February, 2023; originally announced February 2023.

    Journal ref: Eur. Phys. J. C 83, 642 (2023)

  11. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  12. Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

    Authors: E. Ellingwood, H. Benmansour, Q. Hars, J. Hucker, V. Pereimak, J. M. Corning, P. Perrin, G. R. Araujo, P. C. F. Di Stefano, M. Kuźniak, T. R. Pollmann, M. Hamel, M. G. Boulay, B. Cai, D. Gallacher, A. Kemp, J. Mason, P. Skensved, M. Stringer

    Abstract: Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experi… ▽ More

    Submitted 21 December, 2021; originally announced December 2021.

    Comments: 15 pages, 12 figures

  13. Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors

    Authors: D. Gallacher, A. Leonhardt, H. Benmansour, E. Ellingwood, Q. Hars, M. Kuźniak, J. Anstey, B. Bondzior, M. G. Boulay, B. Cai, P. J. Dereń, P. C. F. Di Stefano, S. Garg, J. Mason, T. R. Pollmann, P. Skensved, V. Strickland, M. Stringer

    Abstract: We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection from nuclear-recoil-like events. Nuclear recoils and alpha events preferentially excite the liquid argon (LAr) singlet state, which has a decay time of ~6 ns. The wavelength-shifter TPB, which is typically applied to the… ▽ More

    Submitted 24 December, 2021; v1 submitted 14 September, 2021; originally announced September 2021.

    Comments: 18 pages,10 figures, Submitted to NIMA

  14. arXiv:2108.09405  [pdf, other

    astro-ph.CO astro-ph.HE hep-ex hep-ph

    First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

    Authors: P. Adhikari, R. Ajaj, M. Alpízar-Venegas, D. J. Auty, H. Benmansour, C. E. Bina, W. Bonivento, M. G. Boulay, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, Y. Chen, B. T. Cleveland, J. M. Corning, S. Daugherty, P. DelGobbo, P. Di Stefano, L. Doria, M. Dunford, E. Ellingwood, A. Erlandson, S. S. Farahani, N. Fatemighomi, G. Fiorillo , et al. (72 additional authors not shown)

    Abstract: Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scat… ▽ More

    Submitted 5 January, 2022; v1 submitted 20 August, 2021; originally announced August 2021.

    Journal ref: Phys. Rev. Lett. 128, 011801 (2022)

  15. arXiv:2106.15506  [pdf, other

    physics.ins-det astro-ph.IM

    Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector

    Authors: M. G. Boulay, V. Camillo, N. Canci, S. Choudhary, L. Consiglio, A. Flammini, C. Galbiati, C. Ghiano, A. Gola, S. Horikawa, P. Kachru, I. Kochanek, K. Kondo, G. Korga, M. Kuźniak, M. Kuźwa, A. Leonhardt, T. Łęcki, A. Mazzi, A. Moharana, G. Nieradka, G. Paternoster, T. R. Pollmann, A. Razeto, D. Sablone , et al. (4 additional authors not shown)

    Abstract: A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers,… ▽ More

    Submitted 15 March, 2022; v1 submitted 29 June, 2021; originally announced June 2021.

    Comments: 7 pages, 7 figures

    Journal ref: Eur. Phys. J. C 81, 1099 (2021)

  16. arXiv:2106.03773  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Development of very-thick transparent GEMs with wavelength-shifting capability for noble element TPCs

    Authors: M. Kuźniak, D. González-Díaz, P. Amedo, C. D. R. Azevedo, D. J. Fernández-Posada, M. Kuźwa, S. Leardini, A. Leonhardt, T. Łęcki, L. Manzanillas, D. Muenstermann, G. Nieradka, R. de Oliveira, T. R. Pollmann, A. Saá Hernández, T. Sworobowicz, C. Türkoğlu, S. Williams

    Abstract: A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it… ▽ More

    Submitted 15 March, 2022; v1 submitted 7 June, 2021; originally announced June 2021.

    Comments: accepted for publication in Eur. Phys. J. C

    Journal ref: Eur. Phys. J. C 81, 609 (2021)

  17. arXiv:2103.12202  [pdf, other

    physics.ins-det astro-ph.IM

    Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

    Authors: The DEAP Collaboration, P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, D. J. Auty, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, J. M. Corning , et al. (104 additional authors not shown)

    Abstract: The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar… ▽ More

    Submitted 6 April, 2021; v1 submitted 22 March, 2021; originally announced March 2021.

    Comments: 14 pages, 9 figures

    Journal ref: Eur. Phys. J. C 81, 823 (2021)

  18. arXiv:2006.16960  [pdf, other

    cs.CY

    Digital Contact Tracing Service: An improved decentralized design for privacy and effectiveness

    Authors: Kilian Holzapfel, Martina Karl, Linus Lotz, Georg Carle, Christian Djeffal, Christian Fruck, Christian Haack, Dirk Heckmann, Philipp H. Kindt, Michael Köppl, Patrick Krause, Lolian Shtembari, Lorenz Marx, Stephan Meighen-Berger, Birgit Neumair, Matthias Neumair, Julia Pollmann, Tina Pollmann, Elisa Resconi, Stefan Schönert, Andrea Turcati, Christoph Wiesinger, Giovanni Zattera, Christopher Allan, Esteban Barco , et al. (12 additional authors not shown)

    Abstract: We propose a decentralized digital contact tracing service that preserves the users' privacy by design while complying to the highest security standards. Our approach is based on Bluetooth and measures actual encounters of people, the contact time period, and estimates the proximity of the contact. We trace the users' contacts and the possible spread of infectious diseases while preventing locatio… ▽ More

    Submitted 29 June, 2020; originally announced June 2020.

  19. arXiv:2005.14667  [pdf, other

    astro-ph.CO astro-ph.GA hep-ex hep-ph

    Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector

    Authors: P. Adhikari, R. Ajaj, C. E. Bina, W. Bonivento, M. G. Boulay, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, Y. Chen, B. T. Cleveland, J. M. Corning, S. Daugherty, P. DelGobbo, P. Di Stefano, L. Doria, M. Dunford, A. Erlandson, S. S. Farahani, N. Fatemighomi, G. Fiorillo, D. Gallacher, E. A. Garcés, P. García Abia, S. Garg , et al. (59 additional authors not shown)

    Abstract: DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effect… ▽ More

    Submitted 5 January, 2022; v1 submitted 29 May, 2020; originally announced May 2020.

    Journal ref: Phys. Rev. D 102, 082001 (2020)

  20. arXiv:2005.09493  [pdf, other

    astro-ph.HE astro-ph.IM hep-ex

    The Pacific Ocean Neutrino Experiment

    Authors: M. Agostini, M. Böhmer, J. Bosma, K. Clark, M. Danninger, C. Fruck, R. Gernhäuser, A. Gärtner, D. Grant, F. Henningsen, K. Holzapfel, M. Huber, R. Jenkyns, C. B. Krauss, K. Krings, C. Kopper, K. Leismüller, S. Leys, P. Macoun, S. Meighen-Berger, J. Michel, R. W. Moore, M. Morley, P. Padovani, T. Pollmann , et al. (11 additional authors not shown)

    Abstract: The Pacific Ocean Neutrino Experiment (P-ONE) is a new initiative with a vision towards constructing a multi-cubic kilometre neutrino telescope, to expand our observable window of the Universe to highest energies, installed within the deep Pacific Ocean underwater infrastructure of Ocean Networks Canada.

    Submitted 19 May, 2020; originally announced May 2020.

    Comments: 17 pages, 2 Figures, submitted to Nature Astronomy

    Journal ref: Nat Astron (2020)

  21. arXiv:2004.02024  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Authors: The DarkSide collaboration, C. E. Aalseth, S. Abdelhakim, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, V. Barbaryan, A. Barrado Olmedo, G. Batignani , et al. (290 additional authors not shown)

    Abstract: Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the… ▽ More

    Submitted 26 February, 2021; v1 submitted 4 April, 2020; originally announced April 2020.

    Comments: 26 pages, 22 figures, 3 tables

    Journal ref: Eur. Phys. J. C (2021) 81: 153

  22. The liquid-argon scintillation pulseshape in DEAP-3600

    Authors: The DEAP collaboration, P. Adhikari, R. Ajaj, G. R. Araujoand M. Batygov, B. Beltran, C. E. Bina, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Cárdenas-Montes, S. Cavuoti, Y. Chen, B. T. Cleveland, J. M. Corning, S. J. Daughertyand K. Dering, L. Doria, F. A. Duncan andM. Dunford, A. Erlandson, N. Fatemighomi, G. Fiorillo, A. Flower, R. J. Ford, R. Gagnon , et al. (76 additional authors not shown)

    Abstract: DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed… ▽ More

    Submitted 8 June, 2020; v1 submitted 27 January, 2020; originally announced January 2020.

    Journal ref: Eur. Phys. J. C 80, 303 (2020)

  23. Temperature-dependent fluorescence emission spectra of acrylic (PMMA) and tetraphenyl butadiene (TPB) excited with UV light

    Authors: J. M. Corning, G. R. Araujo, P. C. F. Di Stefano, V. Pereymak, T. Pollmann, P. Skensved

    Abstract: Acrylic (poly(methyl methacrylate) or PMMA) is commonly used as a vessel to hold scintillating liquids in rare-event searches. Certain types of PMMA can fluoresce with a low efficiency at room temperature. We have investigated the fluorescence spectra under 280nm ultraviolet (UV) excitation of the PMMA used in the DEAP dark matter search at various low temperatures. Fluorescence of this PMMA is ob… ▽ More

    Submitted 4 December, 2019; originally announced December 2019.

    Comments: LIDINE 2019, 5 pages, 3 figures

  24. arXiv:1905.05811  [pdf, other

    nucl-ex astro-ph.IM

    Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector

    Authors: R. Ajaj, G. R. Araujo, M. Batygov, B. Beltran, C. E. Bina, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, K. Dering, F. A. Duncan, M. Dunford, A. Erlandson, N. Fatemighomi, G. Fiorillo, A. Flower, R. J. Ford, D. Gallacher, P. García Abia , et al. (66 additional authors not shown)

    Abstract: The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and… ▽ More

    Submitted 14 May, 2019; originally announced May 2019.

    Journal ref: Phys. Rev. D 100, 072009 (2019)

  25. Photoluminescence response of acrylic (PMMA) and polytetrafluoroethylene (PTFE) to ultraviolet light

    Authors: G. R. Araujo, T. Pollmann, A. Ulrich

    Abstract: Some publications indicate that poly(methyl methacrylate) (PMMA) and polytetrafluoroethylene (PTFE) exhibit low levels of photoluminesence (fluorescence and/or phosphorescence) when irradiated with photons in the ultraviolet (UV) to visible range. PMMA (also known as acrylic) and PTFE are commonly used to contain the liquid argon (LAr) or xenon (LXe) target material in rare-event search experiment… ▽ More

    Submitted 20 May, 2019; v1 submitted 8 May, 2019; originally announced May 2019.

    Journal ref: Eur. Phys. J. C (2019) 79: 653

  26. Database support of detector operation and data analysis in the DEAP-3600 Dark Matter experiment

    Authors: T. R. Pollmann, B. Smith

    Abstract: The DEAP-3600 detector searches for dark matter interactions on a 3.3 tonne liquid argon target. Over nearly a decade, from start of detector construction through the end of the data analysis phase, well over 200 scientists will have contributed to the project. The DEAP-3600 detector will amass in excess of 900 TB of data representing more than 10$^{10}$ particle interactions, a few of which could… ▽ More

    Submitted 8 May, 2019; originally announced May 2019.

  27. arXiv:1902.04048  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex nucl-ex

    Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB

    Authors: R. Ajaj, P. -A. Amaudruz, G. R. Araujo, M. Baldwin, M. Batygov, B. Beltran, C. E. Bina, J. Bonatt, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, B. Cai, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, D. Cranshaw, K. Dering, J. DiGioseffo, L. Doria, F. A. Duncan, M. Dunford, A. Erlandson , et al. (77 additional authors not shown)

    Abstract: DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs… ▽ More

    Submitted 4 July, 2019; v1 submitted 11 February, 2019; originally announced February 2019.

    Journal ref: Phys. Rev. D 100, 022004 (2019)

  28. arXiv:1901.10767  [pdf, other

    hep-ex physics.data-an

    Estimating the efficiency turn-on curve for a constant-threshold trigger without a calibration dataset

    Authors: Tina R. Pollmann

    Abstract: Many particle physics experiments use constant threshold triggers, where the trigger threshold is in an online estimator that can be calculated quickly by the trigger module. Offline data analysis then calculates a more precise offline estimator for the same quantity, for example the event energy. The efficiency curve is a step function in the online estimator, but not in the offline estimator.… ▽ More

    Submitted 30 January, 2019; originally announced January 2019.

  29. arXiv:1806.04020  [pdf, other

    physics.ins-det astro-ph.IM astro-ph.SR hep-ex

    Polyethylene naphthalate film as a wavelength shifter in liquid argon detectors

    Authors: M. Kuźniak, B. Broerman, T. Pollmann, G. R. Araujo

    Abstract: Liquid argon-based scintillation detectors are important for dark matter searches and neutrino physics. Argon scintillation light is in the vacuum ultraviolet region, making it hard to be detected by conventional means. Polyethylene naphthalate (PEN), an optically transparent thermoplastic polyester commercially available as large area sheets or rolls, is proposed as an alternative wavelength shif… ▽ More

    Submitted 15 March, 2019; v1 submitted 11 June, 2018; originally announced June 2018.

    Comments: 6 pages, 3 figures

    Journal ref: Eur. Phys. J. C (2019) 79:291

  30. Design and Construction of the DEAP-3600 Dark Matter Detector

    Authors: P. -A. Amaudruz, M. Baldwin, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, P. M. Burghardt, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, S. Churchwell, B. T. Cleveland, D. Cranshaw, K. Dering, J. DiGioseffo, S. Dittmeier, F. A. Duncan , et al. (84 additional authors not shown)

    Abstract: The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a… ▽ More

    Submitted 10 April, 2018; v1 submitted 5 December, 2017; originally announced December 2017.

    Comments: minor corrections in version 2. 70 pages, 24 figures, to be submitted to Astroparticle Physics Journal

    Journal ref: Astropart. Phys. 108 (2019) 1-23

  31. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, M. Ave, H. O. Back, A. I. Barrado Olmedo, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino , et al. (260 additional authors not shown)

    Abstract: Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a… ▽ More

    Submitted 25 July, 2017; originally announced July 2017.

    Report number: FERMILAB-PUB-17-298-PPD

    Journal ref: Aalseth, C.E., Acerbi, F., Agnes, P. et al. Eur. Phys. J. Plus (2018) 133: 131

  32. arXiv:1707.08042  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex hep-ph

    First results from the DEAP-3600 dark matter search with argon at SNOLAB

    Authors: DEAP-3600 Collaboration, :, P. -A. Amaudruz, M. Baldwin, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, P. M. Burghardt, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, B. T. Cleveland, D. Cranshaw, K. Dering, J. DiGioseffo, S. Dittmeier , et al. (81 additional authors not shown)

    Abstract: This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produ… ▽ More

    Submitted 13 August, 2018; v1 submitted 25 July, 2017; originally announced July 2017.

    Comments: Accepted for publication in Physical Review Letters

    Journal ref: Phys. Rev. Lett. 121, 071801 (2018)

  33. In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

    Authors: DEAP Collaboration, P. -A. Amaudruz, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, S. Churchwell, B. T. Cleveland, D. Cranshaw, K. Dering, S. Dittmeier, F. A. Duncan, M. Dunford, A. Erlandson , et al. (77 additional authors not shown)

    Abstract: The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile… ▽ More

    Submitted 29 January, 2019; v1 submitted 29 May, 2017; originally announced May 2017.

    Journal ref: Nucl. Instrum. Methods Phys. Res. A 922, 373-384 (2019)

  34. arXiv:1704.01882  [pdf, other

    astro-ph.IM physics.ins-det

    Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface

    Authors: B. Broerman, M. G. Boulay, B. Cai, D. Cranshaw, K. Dering, S. Florian, R. Gagnon, P. Giampa, C. Gilmour, C. Hearns, J. Kezwer, M. Kuźniak, T. Pollmann, M. Ward

    Abstract: DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a target medium to perform a sensitive spin-independent dark matter search. Argon scintillates in the vacuum ultraviolet spectrum, which requires wavelength shifting to convert the VUV photons to visible so they can be transmitted through the acrylic light guides and detected by the surrounding photomultiplier tubes. The wavele… ▽ More

    Submitted 6 April, 2017; originally announced April 2017.

    Comments: 17 pages, 15 figures, to be published in JINST

    Journal ref: 2017 JINST 12 P04017

  35. arXiv:1511.08424  [pdf, other

    astro-ph.IM physics.ins-det

    Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter

    Authors: L. M. Veloce, M. Kuźniak, P. C. F. Di Stefano, A. J. Noble, M. G. Boulay, P. Nadeau, T. Pollmann, M. Clark, M. Piquemal, K. Schreiner

    Abstract: Liquid noble based particle detectors often use the organic wavelength shifter 1,1,4,4- tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on its own. Dark matter searches based on this type of detector commonly rely on pulse-shape discrimination (PSD) for background mitigation. Alpha-induced scintil… ▽ More

    Submitted 7 June, 2016; v1 submitted 26 November, 2015; originally announced November 2015.

    Journal ref: 2016 JINST 11 P06003

  36. arXiv:1410.7673  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    DEAP-3600 Dark Matter Search

    Authors: DEAP Collaboration, P. -A. Amaudruz, M. Batygov, B. Beltran, J. Bonatt, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Chen, R. Chouinard, B. T. Cleveland, K. Dering, J. DiGioseffo, F. Duncan, T. Flower, R. Ford, P. Giampa, P. Gorel, K. Graham, D. R. Grant, E. Guliyev, A. L. Hallin, M. Hamstra , et al. (32 additional authors not shown)

    Abstract: The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds… ▽ More

    Submitted 25 August, 2015; v1 submitted 27 October, 2014; originally announced October 2014.

    Comments: International Conference on High Energy Physics (ICHEP 2014), Valencia, 2014

    Journal ref: Nuclear and Particle Physics Proceedings 273-275 (2016) 340-346

  37. arXiv:1408.1914  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Authors: M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov, B. Beltran, M. Bodmer, M. G. Boulay, B. Broerman, B. Buck, A. Butcher, B. Cai, T. Caldwell, M. Chen, Y. Chen, B. Cleveland, K. Coakley, K. Dering, F. A. Duncan, J. A. Formaggio, R. Gagnon, D. Gastler, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel, K. Graham , et al. (57 additional authors not shown)

    Abstract: Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We… ▽ More

    Submitted 12 December, 2014; v1 submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 16 figures

  38. arXiv:1211.0909  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

    Authors: P. -A. Amaudruz, M. Batygov, B. Beltran, K. Boudjemline, M. G. Boulay B. Cai T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Contreras, K. Dering, F. Duncan, R. Ford, R. Gagnon F. Giuliani, M. Gold V. V. Golovko, P. Gorel, K. Graham, D. R. Grant, R. Hakobyan, A. L. Hallin, P. Harvey, C. Hearns, C. J. Jillings, M. Kuźniak, I. Lawson, O. Li , et al. (27 additional authors not shown)

    Abstract: The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.… ▽ More

    Submitted 23 April, 2014; v1 submitted 5 November, 2012; originally announced November 2012.

    Journal ref: Astroparticle Physics 62, 178-194 (2015)

  39. arXiv:1203.1576  [pdf, ps, other

    astro-ph.IM astro-ph.CO physics.ins-det

    Surface roughness interpretation of 730 kg days CRESST-II results

    Authors: M. Kuźniak, M. G. Boulay, T. Pollmann

    Abstract: The analysis presented in the recent publication of the CRESST-II results finds a statistically significant excess of registered events over known background contributions in the acceptance region and attributes the excess to a possible Dark Matter signal, caused by scattering of relatively light WIMPs. We propose a mechanism which explains the excess events with ion sputtering caused by 206Pb r… ▽ More

    Submitted 16 July, 2012; v1 submitted 7 March, 2012; originally announced March 2012.

    Comments: 15 pages, 6 figures. v2: corrected quenching factor discussion. v3: corrected references. v4: added references

    Journal ref: Astropart. Phys. 36, 77--82 (2012)

  40. Scintillation of thin tetraphenyl butadiene films under alpha particle excitation

    Authors: Tina Pollmann, Mark Boulay, Marcin Kuźniak

    Abstract: The alpha induced scintillation of the wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) was studied to improve the understanding of possible surface alpha backgrounds in the DEAP dark matter search experiment. We found that vacuum deposited thin TPB films emit 882 +/-210 photons per MeV under alpha particle excitation. The scintillation pulse shape consists of a double exponential decay… ▽ More

    Submitted 3 November, 2010; originally announced November 2010.

    Comments: paper submitted to Nuclear Physics A

    Journal ref: Nucl. Instrum. Methods Phys. Res. A 635, 127-130 (2011)

  41. Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1

    Authors: P. -A. Amaudruz, M. Batygov, B. Beltran, J. Bonatt, K. Boudjemline, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Cranshaw, K. Dering, F. Duncan, N. Fatemighomi, R. Ford, R. Gagnon, P. Giampa, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel , et al. (47 additional authors not shown)

    Abstract: The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV. In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be… ▽ More

    Submitted 14 September, 2016; v1 submitted 20 April, 2009; originally announced April 2009.

    Comments: Accepted for publication in Astroparticle Physics

    Journal ref: Astroparticle Physics 85 (2016) 1-23