Improved electronic measurement of the Boltzmann constant by Johnson noise Thermometry
Authors:
Jifeng Qu,
Samuel P Benz,
Alessio Pollarolo,
Horst Rogalla,
Weston L Tew,
Rod White,
Kunli Zhou
Abstract:
The unit of thermodynamic temperature, the kelvin, will be redefined in 2018 by fixing the value of the Boltzmann constant, k. The present CODATA recommended value of k is determined predominantly by acoustic gas-thermometry results. To provide a value of k based on different physical principles, purely electronic measurements of k were performed by using a Johnson noise thermometer to compare the…
▽ More
The unit of thermodynamic temperature, the kelvin, will be redefined in 2018 by fixing the value of the Boltzmann constant, k. The present CODATA recommended value of k is determined predominantly by acoustic gas-thermometry results. To provide a value of k based on different physical principles, purely electronic measurements of k were performed by using a Johnson noise thermometer to compare the thermal noise power of a 200 Ohm sensing resistor immersed in a triple-point-of-water cell to the noise power of a quantum-accurate pseudo-random noise waveform of nominally equal noise power. Measurements integrated over a bandwidth of 550 kHz and a total integration time of 33 days gave a measured value of k = 1.3806514(48)x10^-23 J/K, for which the relative standard uncertainty is 3.5x10^-6 and the relative offset from the CODATA 2010 value is +1.9x10^-6.
△ Less
Submitted 31 December, 2014;
originally announced January 2015.
-
An Electronic Measurement of the Boltzmann Constant
Authors:
Samuel P. Benz,
Alessio Pollarolo,
Jifeng Qu,
Horst Rogalla,
Chiharu Urano,
Weston L. Tew,
Paul D. Dresselhaus,
D. Rod White
Abstract:
The Boltzmann constant was measured by comparing the Johnson noise of a resistor at the triple point of water with a quantum-based voltage reference signal generated with a superconducting Josephson-junction waveform synthesizer. The measured value of k = 1.380651(18) \times 10^-23 J/K is consistent with the current CODATA value and the combined uncertainties. This is our first measurement of k wi…
▽ More
The Boltzmann constant was measured by comparing the Johnson noise of a resistor at the triple point of water with a quantum-based voltage reference signal generated with a superconducting Josephson-junction waveform synthesizer. The measured value of k = 1.380651(18) \times 10^-23 J/K is consistent with the current CODATA value and the combined uncertainties. This is our first measurement of k with this electronic technique, and the first noise thermometry measurement to achieve a relative combined uncertainty of 13 parts in 10^6. We describe the most recent improvements to our Johnson Noise Thermometer that enabled the statistical uncertainty contribution to be reduced to seven parts in 10^6, as well as the further reduction of spurious systematic errors and EMI effects. The uncertainty budget for this measurement is discussed in detail.
△ Less
Submitted 31 December, 2010;
originally announced January 2011.
-
An absolute Johnson noise thermometer
Authors:
Luca Callegaro,
Vincenzo D'Elia,
Marco Pisani,
Alessio Pollarolo
Abstract:
We developed an absolute Johnson noise thermometer (JNT), an instrument to measure the thermodynamic temperature of a sensing resistor, with traceability to voltage, resistance and frequency quantities. The temperature is measured in energy units, and can be converted to SI units (kelvin) with the accepted value of the Boltzmann constant kb; or, conversely, it can be employed to perform measurem…
▽ More
We developed an absolute Johnson noise thermometer (JNT), an instrument to measure the thermodynamic temperature of a sensing resistor, with traceability to voltage, resistance and frequency quantities. The temperature is measured in energy units, and can be converted to SI units (kelvin) with the accepted value of the Boltzmann constant kb; or, conversely, it can be employed to perform measurements at the triple point of water, and obtain a determination of kb. The thermometer is composed of a correlation spectrum analyzer an a calibrated noise source, both constructed around commercial mixed-signal boards. The calibrator generates a pseudorandom noise, by digital synthesis and amplitude scaling with inductive voltage dividers; the signal spectrum is a frequency comb covering the measurement bandwidth. JNT measurements at room temperature are compatible with those of a standard platinum resistance thermometer within the combined uncertainty of 60 ppm. A path towards future improvements of JNT accuracy is also sketched.
△ Less
Submitted 30 January, 2009;
originally announced January 2009.
-
Very simple FET amplifier with a voltage noise floor less than 1 nV/sqrt(Hz)
Authors:
Luca Callegaro,
Marco Pisani,
Alessio Pollarolo
Abstract:
A field-effect transistor (FET) amplifier for small voltage signals is presented. Its design is elementary and the construction can be afforded by anyone. Despite its simplicity, with a voltage noise less than 1 nV/sqrt(Hz), it outperforms commercially available integrated FET amplifiers. The amplifier has a gain flatness better than 1 dB over 1 MHz bandwidth; it can be employed as a front-end f…
▽ More
A field-effect transistor (FET) amplifier for small voltage signals is presented. Its design is elementary and the construction can be afforded by anyone. Despite its simplicity, with a voltage noise less than 1 nV/sqrt(Hz), it outperforms commercially available integrated FET amplifiers. The amplifier has a gain flatness better than 1 dB over 1 MHz bandwidth; it can be employed as a front-end for signal analyzers or signal recovery systems.
△ Less
Submitted 18 November, 2008;
originally announced November 2008.