-
Low Energy Electron and Nuclear Recoil Thresholds in the DRIFT-II Negative Ion TPC for Dark Matter Searches
Authors:
S. Burgos,
E. Daw,
J. Forbes,
C. Ghag,
M. Gold,
C. Hagemann,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
D. Muna,
A. St. J. Murphy,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
D. P. Snowden-Ifft,
N. J. C. Spooner,
J. Turk,
E. Tziaferi
Abstract:
Understanding the ability to measure and discriminate particle events at the lowest possible energy is an essential requirement in develo** new experiments to search for weakly interacting massive particle (WIMP) dark matter. In this paper we detail an assessment of the potential sensitivity below 10 keV in the 1 m^3 DRIFT-II directionally sensitive, low pressure, negative ion time projection…
▽ More
Understanding the ability to measure and discriminate particle events at the lowest possible energy is an essential requirement in develo** new experiments to search for weakly interacting massive particle (WIMP) dark matter. In this paper we detail an assessment of the potential sensitivity below 10 keV in the 1 m^3 DRIFT-II directionally sensitive, low pressure, negative ion time projection chamber (NITPC), based on event-by-event track reconstruction and calorimetry in the multiwire proportional chamber (MWPC) readout. By application of a digital smoothing polynomial it is shown that the detector is sensitive to sulfur and carbon recoils down to 2.9 and 1.9 keV respectively, and 1.2 keV for electron induced events. The energy sensitivity is demonstrated through the 5.9 keV gamma spectrum of 55Fe, where the energy resolution is sufficient to identify the escape peak. The effect a lower energy sensitivity on the WIMP exclusion limit is demonstrated. In addition to recoil direction reconstruction for WIMP searches this sensitivity suggests new prospects for applications also in KK axion searches.
△ Less
Submitted 30 March, 2009; v1 submitted 2 March, 2009;
originally announced March 2009.
-
First measurement of the Head-Tail directional nuclear recoil signature at energies relevant to WIMP dark matter searches
Authors:
S. Burgos,
E. Daw,
J. Forbes,
C. Ghag,
M. Gold,
C. Hagemann,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
D. Muna,
A. StJ. Murphy,
G. G. Nicklin,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
D. P. Snowden-Ifft,
N. J. C. Spooner,
J. Turk,
E. Tziaferi
Abstract:
We present first evidence for the so-called Head-Tail asymmetry signature of neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the 1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils induced by Weakly Interacting Massive Particle (WIMPs) but one where the differential ionization is poorly understood. We show that the distribution of recoil energi…
▽ More
We present first evidence for the so-called Head-Tail asymmetry signature of neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the 1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils induced by Weakly Interacting Massive Particle (WIMPs) but one where the differential ionization is poorly understood. We show that the distribution of recoil energies and directions induced here by Cf-252 neutrons matches well that expected from massive WIMPs. The results open a powerful new means of searching for a galactic signature from WIMPs.
△ Less
Submitted 10 September, 2008;
originally announced September 2008.
-
Measurement of the Range Component Directional Signature in a DRIFT-II Detector using 252Cf Neutrons
Authors:
S. Burgos,
E. Daw,
J. Forbes,
C. Ghag,
M. Gold,
C. Hagemann,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
D. Muna,
A. St. J. Murphy,
G. G. Nicklin,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
D. P. Snowden-Ifft,
N. J. C. Spooner,
J. Turk,
E. Tziaferi
Abstract:
The DRIFT collaboration utilizes low pressure gaseous detectors to search for WIMP dark matter with directional signatures. A 252Cf neutron source was placed on each of the principal axes of a DRIFT detector in order to test its ability to measure directional signatures from the three components of very low energy (~keV/amu) recoil ranges. A high trigger threshold and the event selection procedu…
▽ More
The DRIFT collaboration utilizes low pressure gaseous detectors to search for WIMP dark matter with directional signatures. A 252Cf neutron source was placed on each of the principal axes of a DRIFT detector in order to test its ability to measure directional signatures from the three components of very low energy (~keV/amu) recoil ranges. A high trigger threshold and the event selection procedure ensured that only sulfur recoils were analyzed. Sulfur recoils produced in the CS2 target gas by the 252Cf source closely match those expected from massive WIMP induced sulfur recoils. For each orientation of the source a directional signal from the range components was observed, indicating that the detector is directional along all 3 axes. An analysis of these results yields an optimal orientation for DRIFT detectors when searching for a directional signature from WIMPs. Additional energy dependent information is provided to aid in understanding this effect.
△ Less
Submitted 24 July, 2008;
originally announced July 2008.
-
Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles
Authors:
S. Burgos,
J. Forbes,
C. Ghag,
M. Gold,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
J. E. McMillan,
D. Muna,
A. StJ. Murphy,
G. G. Nicklin,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
N. J. T. Smith,
D. P. Snowden-Ifft,
N. J. C. Spooner,
T. J. Sumner,
J. Turk,
T. Tziaferi
Abstract:
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of natur…
▽ More
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.
△ Less
Submitted 12 July, 2007;
originally announced July 2007.
-
First Results from the DRIFT-IIa Dark Matter Detector
Authors:
S. Burgos,
J. Forbes,
C. Ghag,
M. Gold,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
D. Muna,
A. StJ. Murphy,
G. G. Nicklin,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
N. J. T. Smith,
D. P. Snowden-Ifft,
N. J. C. Spooner,
T. J. Sumner,
J. Turk,
E. Tziaferi
Abstract:
Data from the DRIFT-IIa directional dark matter experiment are presented, collected during a near continuous 6 month running period. A detailed calibration analysis comparing data from gamma-ray, x-ray and neutron sources to a GEANT4 Monte Carlo simulations reveals an efficiency for detection of neutron induced recoils of 94+/-2(stat.)+/-5(sys.)%. Software-based cuts, designed to remove non-nucl…
▽ More
Data from the DRIFT-IIa directional dark matter experiment are presented, collected during a near continuous 6 month running period. A detailed calibration analysis comparing data from gamma-ray, x-ray and neutron sources to a GEANT4 Monte Carlo simulations reveals an efficiency for detection of neutron induced recoils of 94+/-2(stat.)+/-5(sys.)%. Software-based cuts, designed to remove non-nuclear recoil events, are shown to reject 60Co gamma-rays with a rejection factor of better than 8x10-6 for all energies above threshold. An unexpected event population has been discovered and is shown here to be due to the alpha-decay of 222Rn daughter nuclei that have attached to the central cathode. A limit on the flux of neutrons in the Boulby Underground Laboratory is derived from analysis of unshielded and shielded data.
△ Less
Submitted 10 July, 2007;
originally announced July 2007.
-
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
Authors:
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
B. Camanzi,
M. J. Carson,
R. J. Cashmore,
H. Chagani,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
J. Gao,
C. Ghag,
A. S. Howard,
W. G. Jones,
M. Joshi,
E. V. Korolkova,
V. A. Kudryavtsev,
T. Lawson
, et al. (36 additional authors not shown)
Abstract:
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ra…
▽ More
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
△ Less
Submitted 31 January, 2007; v1 submitted 30 January, 2007;
originally announced January 2007.
-
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
Authors:
D. Yu. Akimov,
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
A. A. Burenkov,
M. J. Carson,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Chag,
R. J. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
I. S. Kuznetsov
, et al. (35 additional authors not shown)
Abstract:
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of…
▽ More
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
△ Less
Submitted 19 May, 2006;
originally announced May 2006.