-
Quantum state discrimination enhanced by path signature
Authors:
Shuxiang Cao,
Zhen Shao,
Jian-Qing Zheng,
Mohammed Alghadeer,
Simone D Fasciati,
Michele Piscitelli,
Sajjad Taravati,
Mustafa Bakr,
Terry Lyons,
Peter Leek
Abstract:
Quantum state discrimination plays an essential role in quantum technology, crucial for quantum error correction, metrology, and sensing. While conventional methods rely on integrating readout signals or classifying raw signals, we developed a method to extract information about state transitions during readout, based on the path signature method, a tool for analyzing stochastic time series. The h…
▽ More
Quantum state discrimination plays an essential role in quantum technology, crucial for quantum error correction, metrology, and sensing. While conventional methods rely on integrating readout signals or classifying raw signals, we developed a method to extract information about state transitions during readout, based on the path signature method, a tool for analyzing stochastic time series. The hardware experiments demonstrate an improvement in transmon qutrit state readout fidelity from 85.9 $\pm$ 1.0% to 91.0 $\pm$ 0.5%, without the need for additional hardware. This method has the potential to become a foundational tool for quantum technology.
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
pH-conditioning of recognition layers enables single-molecule affinity detections at 10E-20 molar
Authors:
Eleonora Macchia,
Cinzia Di Franco,
Cecilia Scandurra,
Lucia Sarcina,
Matteo Piscitelli,
Michele Catacchio,
Mariapia Caputo,
Paolo Bollella,
Gaetano Scamarcio,
Luisa Torsi
Abstract:
While nucleic-acids can be readily amplified for single-marker detection, a comparable method for proteins assay is currently unavailable. Proteins potentiometric detections at 10-20 molar have been demonstrated, but the mechanism remains elusive. Here, we unveil how pH-conditioning within the trillions of recognition elements densely packed on a millimeter-large surface, enables single protein or…
▽ More
While nucleic-acids can be readily amplified for single-marker detection, a comparable method for proteins assay is currently unavailable. Proteins potentiometric detections at 10-20 molar have been demonstrated, but the mechanism remains elusive. Here, we unveil how pH-conditioning within the trillions of recognition elements densely packed on a millimeter-large surface, enables single protein or DNA selective detections in 0.1 mL of a biofluid. Plasmonic, electronic and surface probing techniques demonstrate that a conformational change, elicited by a single-affinity binding, alters the secondary and tertiary structure of the recognition elements. A phenomenological mechanism foresees that the pH-conditioning initiates a hydrophobization process leading to the formation of a partially aggregated and metastable state that facilitates the amplification spreading. Impact on protein aggregates control and biomarker-based diagnostics, is envisaged.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
Nanometer-Scale Nuclear Magnetic Resonance Diffraction with Sub-Ångstrom Precision
Authors:
Holger Haas,
Sahand Tabatabaei,
William Rose,
Pardis Sahafi,
Michèle Piscitelli,
Andrew Jordan,
Pritam Priyadarsi,
Namanish Singh,
Ben Yager,
Philip J. Poole,
Dan Dalacu,
Raffi Budakian
Abstract:
Achieving atomic resolution is the ultimate limit of magnetic resonance imaging (MRI), and attaining this capability offers enormous technological and scientific opportunities, from drug development to understanding the dynamics in interacting quantum systems. In this work, we present a new approach to nanoMRI utilizing nuclear magnetic resonance diffraction (NMRd) -- a method that extends NMR ima…
▽ More
Achieving atomic resolution is the ultimate limit of magnetic resonance imaging (MRI), and attaining this capability offers enormous technological and scientific opportunities, from drug development to understanding the dynamics in interacting quantum systems. In this work, we present a new approach to nanoMRI utilizing nuclear magnetic resonance diffraction (NMRd) -- a method that extends NMR imaging to probe the structure of periodic spin systems. The realization of NMRd on the atomic scale would create a powerful new methodology for materials characterization utilizing the spectroscopic capabilities of NMR. We describe two experiments that realize NMRd measurement of $^{31}$P spins in an indium-phosphide (InP) nanowire with sub-Ångstrom precision. In the first experiment, we encode a nanometer-scale spatial modulation of the $z$-axis magnetization by periodically inverting the $^{31}$P spins, and detect the period and position of the modulation with a precision of $<0.8$ Å. In the second experiment, we demonstrate an interferometric technique, utilizing NMRd, for detecting an Ångstrom-scale displacement of the InP sample with a precision of 0.07 Å. The diffraction-based techniques developed in this work represent new measurement modalities in NMR for probing the structure and dynamics of spins on sub-Ångstrom length scales, and demonstrate the feasibility of crystallographic MRI measurements.
△ Less
Submitted 1 April, 2022;
originally announced April 2022.
-
Numerical Engineering of Robust Adiabatic Operations
Authors:
Sahand Tabatabaei,
Holger Haas,
William Rose,
Ben Yager,
Michèle Piscitelli,
Pardis Sahafi,
Andrew Jordan,
Philip J. Poole,
Dan Dalacu,
Raffi Budakian
Abstract:
Adiabatic operations are powerful tools for robust quantum control in numerous fields of physics, chemistry and quantum information science. The inherent robustness due to adiabaticity can, however, be impaired in applications requiring short evolution times. We present a single versatile gradient-based optimization protocol that combines adiabatic control with effective Hamiltonian engineering in…
▽ More
Adiabatic operations are powerful tools for robust quantum control in numerous fields of physics, chemistry and quantum information science. The inherent robustness due to adiabaticity can, however, be impaired in applications requiring short evolution times. We present a single versatile gradient-based optimization protocol that combines adiabatic control with effective Hamiltonian engineering in order to design adiabatic operations tailored to the specific imperfections and resources of an experimental setup. The practicality of the protocol is demonstrated by engineering a fast, 2.3 Rabi cycle-long adiabatic inversion pulse for magnetic resonance with built-in robustness to Rabi field inhomogeneities and resonance offsets. The performance and robustness of the pulse is validated in a nanoscale force-detected magnetic resonance experiment on a solid-state sample, indicating an ensemble-averaged inversion accuracy of $\sim 99.997\%$. We further showcase the utility of our protocol by providing examples of adiabatic pulses robust to spin-spin interactions, parameter-selective operations and operations connecting arbitrary states, each motivated by experiments.
△ Less
Submitted 30 April, 2021; v1 submitted 7 September, 2020;
originally announced September 2020.
-
Ultra-low dissipation patterned silicon nanowire arrays for scanning probe microscopy
Authors:
Pardis Sahafi,
William Rose,
Andrew Jordan,
Ben Yager,
Michèle Piscitelli,
Raffi Budakian
Abstract:
In recent years, self-assembled semiconductor nanowires have been successfully used as ultra-sensitive cantilevers in a number of unique scanning probe microscopy (SPM) settings. We describe the fabrication of ultra-low dissipation patterned silicon nanowire (SiNW) arrays optimized for scanning probe applications. Our fabrication process produces, with high yield, ultra-high aspect ratio vertical…
▽ More
In recent years, self-assembled semiconductor nanowires have been successfully used as ultra-sensitive cantilevers in a number of unique scanning probe microscopy (SPM) settings. We describe the fabrication of ultra-low dissipation patterned silicon nanowire (SiNW) arrays optimized for scanning probe applications. Our fabrication process produces, with high yield, ultra-high aspect ratio vertical SiNWs that exhibit exceptional force sensitivity. The highest sensitivity SiNWs have thermomechanical-noise limited force sensitivity of $9.7\pm0.4~\text{aN}/\sqrt{\text{Hz}}$ at room temperature and $500\pm20~\text{zN}/\sqrt{\text{Hz}}$ at 4 K. To facilitate their use in SPM, the SiNWs are patterned within $7~μ\text{m}$ from the edge of the substrate, allowing convenient optical access for displacement detection.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.