-
Multi-Blade detector with VMM3a-ASIC-based readout: installation and commissioning at the reflectometer Amor at PSI
Authors:
F. Piscitelli,
F. Ghazi Moradi,
F. S. Alves,
M. J. Christensen,
J. Hrivnak,
A. Johansson,
K. Fissum,
C. C. Lai,
A. Monera Martinez,
D. Pfeiffer,
E. Shahu,
J. Stahn,
P. O. Svensson
Abstract:
The Multi-Blade (MB) Boron-10-based neutron detector is the chosen technology for three instruments at the European Spallation Source (ESS): the two ESS reflectometers, ESTIA and FREIA, and the Test Beam Line. A fourth MB detector has been built, installed and commissioned for the user operation of the reflectometer Amor at PSI (Switzerland). Amor can be considered a downscaled version of the ESS…
▽ More
The Multi-Blade (MB) Boron-10-based neutron detector is the chosen technology for three instruments at the European Spallation Source (ESS): the two ESS reflectometers, ESTIA and FREIA, and the Test Beam Line. A fourth MB detector has been built, installed and commissioned for the user operation of the reflectometer Amor at PSI (Switzerland). Amor can be considered a downscaled version of the ESS reflectometer ESTIA. They are based on the same Selene guide concept, optimized for performing focusing reflectometry on small samples. The experience gained at Amor is invaluable for the future deployment of the MB detector at the ESS. This manuscript describes the MB detector construction and installation at Amor along with the readout electronics chain based on the VMM3a ASIC. The readout chain deployed at Amor is equivalent of that of the ESS, including the readout master module (RMM), event-formation-units (EFUs), Kafka, FileWriter and live visualisation tools.
△ Less
Submitted 18 March, 2024; v1 submitted 13 February, 2024;
originally announced February 2024.
-
Verification of He-3 proportional counters fast neutron sensitivity through a comparison with He-4 detectors
Authors:
Francesco Piscitelli,
Giacomo Mauri,
Alessio Laloni,
Richard Hall-Wilton
Abstract:
In the field of neutron scattering science, a large variety of instruments require detectors for thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold neutron detection for many years. Nowadays neutron facilities around the world are pushing their technologies to increase the available flux delivered at the instruments, this enables a completely new science landsc…
▽ More
In the field of neutron scattering science, a large variety of instruments require detectors for thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold neutron detection for many years. Nowadays neutron facilities around the world are pushing their technologies to increase the available flux delivered at the instruments, this enables a completely new science landscape. Complementary with the increasing available flux, a better signal-to-background ratio (S/B) enables to perform new types of measurements. To this aim, this manuscript re-examines the background sensitivity of today's "gold standard" neutron detection. Fast neutrons and gamma-rays are the main background species in neutron scattering experiments. The efficiency (sensitivity) of detecting fast neutrons, cosmic rays and gamma-rays, for a Helium-3-based detector is studied here through the comparison with Helium-4 counters. The comparison to Helium-4 allows to separate the thermal (and cold) neutron to the fast neutron contributions in Helium-3-based counters, which are otherwise entangled; verifying previous results from an indirect method. A relatively high sensitivity is found. Moreover, an estimate for the cosmic neutron fluence, also a source of background, at ground level at ESS is presented in this manuscript.
△ Less
Submitted 19 February, 2020;
originally announced February 2020.
-
The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer
Authors:
G. Mauri,
I. Apostolidis,
M. J. Christensen,
A. Glavic,
C. C. Lai,
A. Laloni,
F. Messi,
A. Lindh Olsson,
L. Robinson,
J. Stahn,
P. O. Svensson,
R. Hall-Wilton,
F. Piscitelli
Abstract:
The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scale…
▽ More
The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scaled-down demonstrator of Estia. The results of these tests are discussed. It will be shown how the characteristics of the Multi-Blade detector are features that allow the focusing reflectometry operation mode. Additionally the performance of the Multi-Blade, in terms of rate capability, exceeds current state-of-the-art technology. The improvements with respect to the previous prototypes are also highlighted; from background considerations to the linear and angular uniformity response of the detector.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.
-
Evidence of fast neutron sensitivity for 3He detectors and comparison with Boron-10 based neutron detectors
Authors:
Giacomo Mauri,
Francesco Messi,
Kalliopi Kanaki,
Richard Hall-Wilton,
Francesco Piscitelli
Abstract:
The 3He-based neutron detectors are no longer the default solution for neutron scattering applications. Both the inability of fulfilling the requirements in performance, needed for the new instruments, and the shortage of 3He, drove a series of research programs aiming to find new technologies for neutron detection. The characteristics of the new detector technologies have been extensively tested…
▽ More
The 3He-based neutron detectors are no longer the default solution for neutron scattering applications. Both the inability of fulfilling the requirements in performance, needed for the new instruments, and the shortage of 3He, drove a series of research programs aiming to find new technologies for neutron detection. The characteristics of the new detector technologies have been extensively tested to prove their effectiveness with respect to the state-of-the-art technology. Among these, the background rejection capability is crucial to determine. The signal-to-background ratio is strongly related to the performance figure-of-merit for most instruments. These are designed to exploit the high flux expected from the new high intensity neutron sources. Therefore, an inadequate background rejection could significantly affect the measurements, leading to detector saturation and misleading events. This is of particular importance for the kind of techniques in which the signals are rather weak. For the first time, the sensitivity of 3He detectors to fast neutrons, up to En = 10 MeV, has been estimated. Two independent measurements are presented: a direct calculation based on a subtraction method used to disentangle the thermal and the fast neutron contribution, while a further evidence is calculated indirectly through a comparison with the recently published data from a 10B-based detector. Both investigations give a characterization on the order of magnitude for the sensitivity. A set of simulations is presented as well in order to support and to validate the results of the measurements. A sensitivity of 4x10-3 is observed from the data. This is two orders of magnitude higher than that previously observed in 10B-based detectors.
△ Less
Submitted 26 February, 2019;
originally announced February 2019.
-
Investigation of neutron scattering in the Multi-Blade detector with Geant4 simulations
Authors:
Gabor Galgoczi,
Kalliopi Kanaki,
Francesco Piscitelli,
Thomas Kittelmann,
Dezso Varga,
Richard Hall-Wilton
Abstract:
The European Spallation Source (ESS) is the world's next generation spallation-based neutron source. The research conducted at ESS will yield in the discovery and development of new materials including the fields of manufacturing, pharmaceuticals, aerospace, engines, plastics, energy, telecommunications, transportation, information technology and biotechnology. The spallation source will deliver a…
▽ More
The European Spallation Source (ESS) is the world's next generation spallation-based neutron source. The research conducted at ESS will yield in the discovery and development of new materials including the fields of manufacturing, pharmaceuticals, aerospace, engines, plastics, energy, telecommunications, transportation, information technology and biotechnology. The spallation source will deliver an unprecedented neutron flux. In particular, the reflectometers selected for construction, ESTIA and FREIA, have to fulfill challenging requirements. Local incident peak rate can reach 10$^5$~Hz/mm$^2$. For new science to be addressed, the spatial resolution is aimed to be less than 1 mm with a desired scattering of 10$^{-4}$ (peak-to-tail ratio). The latter requirement is approximately two orders of magnitude better than the current state-of-the-art detectors. The main aim of this work is to quantify the cumulative contribution of various detector components to the scattering of neutrons and to prove that the respective effect is within the requirements set for the Multi-Blade detector by the ESS reflectometers. To this end, different sets of geometry and beam parameters are investigated, with primary focus on the cathode coating and the detector window thickness.
△ Less
Submitted 27 November, 2018; v1 submitted 15 October, 2018;
originally announced October 2018.
-
Software-based data acquisition and processing for neutron detectors at European Spallation Source - early experience from four detector designs
Authors:
M. J. Christensen,
R. Al Jebali,
T. Blum,
R. Hall-Wilton,
A. Khaplanov,
M. Lupberger,
F. Messi,
A. Mukai,
J. Nilsson,
D. Pfeiffer,
F. Piscitelli,
T. Richter,
M. Shetty,
S. Skelboe,
C. Søgaard
Abstract:
European Spallation Source (ESS) will deliver neutrons at high flux for use in diverse neutron scattering techniques. The neutron source facility and the scientific instruments will be located in Lund, and the Data Management and Software Centre (DMSC), in Copenhagen. A number of detector prototypes are being developed at ESS together with its European in-kind partners, for example: SoNDe, Multi-G…
▽ More
European Spallation Source (ESS) will deliver neutrons at high flux for use in diverse neutron scattering techniques. The neutron source facility and the scientific instruments will be located in Lund, and the Data Management and Software Centre (DMSC), in Copenhagen. A number of detector prototypes are being developed at ESS together with its European in-kind partners, for example: SoNDe, Multi-Grid, Multi-Blade and Gd-GEM. These are all position sensitive detectors but use different techniques for the detection of neutrons. Except for digitization of electronics readout, all neutron data is anticipated to be processed in software. This provides maximum flexibility and adaptability and allows deep inspection of the raw data for commissioning which will reduce the risk of starting up new detector technologies. But it also requires development of high performance software processing pipelines and optimized and scalable processing algorithms. This report provides a description of the ESS system architecture for the neutron data path. Special focus is on the interface between the detectors and DMSC which is based on UDP over Ethernet links. The report also describes the software architecture for detector data processing and the tools we have developed, which have proven very useful for efficient early experimentation, and can be run on a single laptop. Processing requirements for the SoNDe, Multi-Grid, Multi-Blade and Ge-GEM detectors are presented and compared to event processing rates archived so far.
△ Less
Submitted 22 October, 2018; v1 submitted 11 July, 2018;
originally announced July 2018.
-
Neutron reflectometry with the Multi-Blade 10B-based detector
Authors:
G. Mauri,
F. Messi,
M. Anastasopoulos,
T. Arnold,
A. Glavic,
C. Höglund,
T. Ilves,
I. Lopez Higuera,
P. Pazmandi,
D. Raspino,
L. Robinson,
S. Schmidt,
P. Svensson,
D. Varga,
R. Hall-Wilton,
F. Piscitelli
Abstract:
The Multi-Blade is a Boron-10-based gaseous detector developed for neutron reflectometry instruments at the European Spallation Source (ESS) in Sweden. The main challenges for neutron reflectometry detectors are the instantaneous counting rate and spatial resolution. The Multi-Blade has been tested on the CRISP reflectometer at the ISIS neutron and muon source in UK. A campaign of scientific measu…
▽ More
The Multi-Blade is a Boron-10-based gaseous detector developed for neutron reflectometry instruments at the European Spallation Source (ESS) in Sweden. The main challenges for neutron reflectometry detectors are the instantaneous counting rate and spatial resolution. The Multi-Blade has been tested on the CRISP reflectometer at the ISIS neutron and muon source in UK. A campaign of scientific measurements has been performed to study the Multi-Blade response in real instrumental conditions. The results of these tests are discussed in this manuscript.
△ Less
Submitted 18 April, 2018; v1 submitted 11 April, 2018;
originally announced April 2018.
-
Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS
Authors:
F. Piscitelli,
G. Mauri,
F. Messi,
M. Anastasopoulos,
T. Arnold,
A. Glavic,
C. Höglund,
T. Ilves,
I. Lopez Higuera,
P. Pazmandi,
D. Raspino,
L. Robinson,
S. Schmidt,
P. Svensson,
D. Varga,
R. Hall-Wilton
Abstract:
The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed according to the requirements given by the reflectometers at the European Spallation Source (ESS) i…
▽ More
The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed according to the requirements given by the reflectometers at the European Spallation Source (ESS) in Sweden. The Multi-Blade has been installed and tested on the CRISP reflectometer at the ISIS neutron and muon source in UK. The results on the detailed detector characterization are discussed in this manuscript.
△ Less
Submitted 26 March, 2018;
originally announced March 2018.
-
DECal, a Python tool for the efficiency calculation of thermal neutron detectors based on thin-film converters
Authors:
Álvaro Carmona Basañez,
Kalliopi Kanaki,
Francesco Piscitelli
Abstract:
The Detector Efficiency Calculator (DECal) is a series of Python functions and tools designed to analytically calculate, visualise and optimise the detection efficiency of thermal neutron detectors, which are based on thin-film converters. The implementation presented in this article concerns 10B-based detectors in particular. The code can be run via a graphical user interface, as well as via the…
▽ More
The Detector Efficiency Calculator (DECal) is a series of Python functions and tools designed to analytically calculate, visualise and optimise the detection efficiency of thermal neutron detectors, which are based on thin-film converters. The implementation presented in this article concerns 10B-based detectors in particular. The code can be run via a graphical user interface, as well as via the command line. The source code is openly available to interested users via a GitHub repository.
△ Less
Submitted 22 January, 2018;
originally announced January 2018.
-
Fast neutron sensitivity of neutron detectors based on boron-10 converter layers
Authors:
G. Mauri,
F. Messi,
K. Kanaki,
R. Hall-Wilton,
E. Karnickis,
A. Khaplanov,
F. Piscitelli
Abstract:
In the last few years many detector technologies for thermal neutron detection have been developed in order to face the shortage of 3He, which is now much less available and more expensive. Moreover the 3He-based detectors can not fulfil the requirements in performance, e.g. the spatial resolution and the counting rate capability needed for the new instruments. The Boron-10-based gaseous detectors…
▽ More
In the last few years many detector technologies for thermal neutron detection have been developed in order to face the shortage of 3He, which is now much less available and more expensive. Moreover the 3He-based detectors can not fulfil the requirements in performance, e.g. the spatial resolution and the counting rate capability needed for the new instruments. The Boron-10-based gaseous detectors have been proposed as a suitable choice. This and other alternatives technologies are being developed at ESS. Higher intensities mean higher signals but higher background as well. The signal-to-background ratio is an important feature to study, in particular the gamma-ray and the fast neutron contributions. This paper investigates, for the first time, the fast neutrons sensitivity of 10B-based thermal neutron detector. It presents the study of the detector response as a function of energy threshold and the underlying physical mechanisms. The latter are explained with the help of theoretical considerations and simulations.
△ Less
Submitted 15 December, 2017;
originally announced December 2017.
-
The neutron tagging facility at Lund University
Authors:
F. Messi,
H. Perrey,
K. Fissum,
M. Akkawi,
R. Al Jebali,
J. R. M. Annand,
P. Bentley,
L. Boyd,
C. P. Cooper-Jensen,
D. D. DiJulio,
J. Freita-Ramos,
R. Hall-Wilton,
A. Huusko,
T. Ilves,
F. Issa,
A. Jalgén,
K. Kanaki,
E. Karnickis,
A. Khaplanov,
S. Koufigar,
V. Maulerova,
G. Mauri,
N. Mauritzson,
W. Pei,
F. Piscitelli
, et al. (5 additional authors not shown)
Abstract:
Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation p…
▽ More
Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation process is in general long and expensive. The study of detector prototypes using neutron-emitting radioactive sources is a cost-effective solution, especially for preliminary investigations. That said, neutron-emitting sources have the general disadvantage of broad, structured, emitted-neutron energy ranges. Further, the emitted neutrons often compete with unwanted backgrounds of gamma-rays, alpha-particles, and fission-fragments. By blending experimental infrastructure such as shielding to provide particle beams with neutron-detection techniques such as tagging, disadvantages may be converted into advantages. In particular, a technique known as tagging involves exploiting the mixed-field generally associated with a neutron-emitting source to determine neutron time-of-flight and thus energy on an event-by-event basis. This allows for the definition of low-cost, precision neutron beams. The Source-Testing Facility, located at Lund University in Sweden and operated by the SONNIG Group of the Division of Nuclear Physics, was developed for just such low-cost studies. Precision tagged-neutron beams derived from radioactive sources are available around-the-clock for advanced detector diagnostic studies. Neutron measurements performed at the Source Testing Facility are thus cost-effective and have a very low barrier for entry. In this paper, we present an overview of the project.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
Authors:
M. Anastasopoulos,
R. Bebb,
K. Berry,
J. Birch,
T. Bryś,
J. -C. Buffet,
J. -F. Clergeau,
P. P. Deen,
G. Ehlers,
P. van Esch,
S. M. Everett,
B. Guerard,
R. Hall-Wilton,
K. Herwig,
L. Hultman,
C. Höglund,
I. Iruretagoiena,
F. Issa,
J. Jensen,
A. Khaplanov,
O. Kirstein,
I. Lopez-Higuera,
F. Piscitelli,
L. Robinson,
S. Schmidt
, et al. (1 additional authors not shown)
Abstract:
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demo…
▽ More
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
△ Less
Submitted 3 April, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
The Multi-Blade Boron-10-based Neutron Detector for high intensity Neutron Reflectometry at ESS
Authors:
Francesco Piscitelli,
Francesco Messi,
Michail Anastasopoulos,
Tomasz Bryś,
Faye Chicken,
Eszter Dian,
Janos Fuzi,
Carina Höglund,
Gabor Kiss,
Janos Orban,
Peter Pazmandi,
Linda Robinson,
Laszlo Rosta,
Susann Schmidt,
Dezso Varga,
Tibor Zsiros,
Richard Hall-Wilton
Abstract:
The Multi-Blade is a Boron-10-based gaseous detector introduced to face the challenge arising in neutron reflectometry at pulsed neutron sources. Neutron reflectometers are the most challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed to cope with the requirements set for the reflectometers at the upcoming European Spallation Sourc…
▽ More
The Multi-Blade is a Boron-10-based gaseous detector introduced to face the challenge arising in neutron reflectometry at pulsed neutron sources. Neutron reflectometers are the most challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed to cope with the requirements set for the reflectometers at the upcoming European Spallation Source (ESS) in Sweden. Based on previous results obtained at the Institut Laue-Langevin (ILL) in France, an improved demonstrator has been built at ESS and tested at the Budapest Neutron Centre (BNC) in Hungary and at the Source Testing Facility (STF) at the Lund University in Sweden. A detailed description of the detector and the results of the tests are discussed in this manuscript.
△ Less
Submitted 26 January, 2017;
originally announced January 2017.
-
Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors
Authors:
F. Piscitelli,
A. Khaplanov,
A. Devishvili,
S. Schmidt,
C. Höglund,
J. Birch,
A. J. C. Dennison,
P. Gutfreund,
R. Hall-Wilton,
P. Van Esch
Abstract:
Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In the case of strongly absorbing nuclei the number of neutrons is not conserved and the absorption can be directly measured by using the neutron-induced fluoresce…
▽ More
Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In the case of strongly absorbing nuclei the number of neutrons is not conserved and the absorption can be directly measured by using the neutron-induced fluorescence technique which exploits the prompt particle emission of absorbing isotopes. This technique is emerging from soft matter and biology where highly absorbing nuclei, generally in very small quantities, are used as a label for buried layers. Nowadays the importance of highly absorbing layers is rapidly increasing, partially because of their application in neutron detection; a field that has become more and more active also due to the 3He-shortage. In this manuscript we extend the neutron-induced fluorescence technique to the study of thick layers of highly absorbing materials; in particular 10B4C. The theory of neutron reflectometry is a commonly studied topic, however the subtle relationship between the reflection and the absorption of neutrons is not widely known, in particular when a strong absorption is present. The theory for a general stack of absorbing layers has been developed and compared to measurements. This new technique has potential as a tool for characterization of highly absorbing layers. We also report on the requirements that a 10B4C layer must fulfill in order to be employed as a converter in neutron detection.
△ Less
Submitted 5 October, 2015;
originally announced October 2015.
-
Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
Authors:
J. Birch,
J. -C. Buffet,
J. -F. Clergeau,
P. van Esch,
M. Ferraton,
B. Guerard,
R. Hall-Wilton,
L. Hultman,
C. Höglund,
J. Jensen,
A. Khaplanov,
F. Piscitelli
Abstract:
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of…
▽ More
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of of the Multi-Grid detector and other similar concepts due to its mechanical and neutronic properties. Due to natural concentration of $α$ emitters, however, the background from $α$ particles misidentified as neutrons can be unacceptably high. We present our experience operating a detector prototype affected by this issue. Monte Carlo simulations have been used to confirm the background as $α$ particles. The issues have been addressed in the more recent implementations of the Multi-Grid detector by the use of purified aluminium as well as Ni-plating of standard aluminium. The result is the reduction in background by two orders of magnitude. A new large-area prototype has been built incorporating these modifications.
△ Less
Submitted 16 September, 2015; v1 submitted 2 July, 2015;
originally announced July 2015.
-
Novel Boron-10-based detectors for Neutron Scattering Science
Authors:
Francesco Piscitelli
Abstract:
Nowadays neutron scattering science is increasing its instrumental power. Most of the neutron sources in the world are pushing the development of their technologies to be more performing. The neutron scattering development is also pushed by the European Spallation Source (ESS) in Sweden, a neutron facility which has just started construction. Concerning small area detectors (1m^2), the 3He technol…
▽ More
Nowadays neutron scattering science is increasing its instrumental power. Most of the neutron sources in the world are pushing the development of their technologies to be more performing. The neutron scattering development is also pushed by the European Spallation Source (ESS) in Sweden, a neutron facility which has just started construction. Concerning small area detectors (1m^2), the 3He technology, which is today cutting edge, is reaching fundamental limits in its development. Counting rate capability, spatial resolution and cost-effectiveness, are only a few examples of the features that must be improved to fulfill the new requirements. On the other hand, 3He technology could still satisfy the detector requirements for large area applications (50m^2), however, because of the present 3He shortage that the world is experiencing, this is not practical anymore. The recent detector advances (the Multi-Grid and the Multi-Blade prototypes) developed in the framework of the collaboration between the Institut Laue-Langevin (ILL) and ESS are presented in this manuscript. In particular two novel 10B-based detectors are described; one for large area applications (the Multi-Grid prototype) and one for application in neutron refectometry (small area applications, the Multi-Blade prototype).
△ Less
Submitted 21 January, 2015;
originally announced January 2015.
-
Neutron Position Sensitive Detectors for the ESS
Authors:
Oliver Kirstein,
Richard Hall-Wilton,
Irina Stefanescu,
Maddi Etxegarai,
Michail Anastasopoulos,
Kevin Fissum,
Anna Gulyachkina,
Carina Höglund,
Mewlude Imam,
Kalliopi Kanaki,
Anton Khaplanov,
Thomas Kittelmann,
Scott Kolya,
Björn Nilsson,
Luis Ortega,
Dorothea Pfeiffer,
Francesco Piscitelli,
Judith Freita Ramos,
Linda Robinson,
Julius Scherzinger
Abstract:
The European Spallation Source (ESS) in Lund, Sweden will become the world's leading neutron source for the study of materials. The instruments are being selected from conceptual proposals submitted by groups from around Europe. These instruments present numerous challenges for detector technology in the absence of the availability of Helium-3, which is the default choice for detectors for instrum…
▽ More
The European Spallation Source (ESS) in Lund, Sweden will become the world's leading neutron source for the study of materials. The instruments are being selected from conceptual proposals submitted by groups from around Europe. These instruments present numerous challenges for detector technology in the absence of the availability of Helium-3, which is the default choice for detectors for instruments built until today and due to the extreme rates expected across the ESS instrument suite. Additionally a new generation of source requires a new generation of detector technologies to fully exploit the opportunities that this source provides. The detectors will be sourced from partners across Europe through numerous in-kind arrangements; a process that is somewhat novel for the neutron scattering community. This contribution presents briefly the current status of detectors for the ESS, and outlines the timeline to completion. For a conjectured instrument suite based upon instruments recommended for construction, a recently updated snapshot of the current expected detector requirements is presented. A strategy outline as to how these requirements might be tackled by novel detector developments is shown. In terms of future developments for the neutron community, synergies should be sought with other disciples, as recognized by various recent initiatives in Europe, in the context of the fundamentally multi-disciplinary nature of detectors. This strategy has at its basis the in-kind and collaborative partnerships necessary to be able to produce optimally performant detectors that allow the ESS instruments to be world-leading. This foresees and encourages a high level of collaboration and interdependence at its core, and rather than each group being all-rounders in every technology, the further development of centres of excellence across Europe for particular technologies and niches.
△ Less
Submitted 23 November, 2014;
originally announced November 2014.
-
Boron-10 layers, Neutron Reflectometry and Thermal Neutron Gaseous Detectors
Authors:
Francesco Piscitelli
Abstract:
Nowadays neutron facilities are going toward higher fluxes, e.g. the European Spallation Source (ESS) in Lund (Sweden), and this translates into a higher demand in the instrument performances. Because of its favorable properties,He-3 has been the main actor in thermal neutron detection for years. Starting in about 2001 the He-3 stockpile has been declining. The world is now experiencing the shorta…
▽ More
Nowadays neutron facilities are going toward higher fluxes, e.g. the European Spallation Source (ESS) in Lund (Sweden), and this translates into a higher demand in the instrument performances. Because of its favorable properties,He-3 has been the main actor in thermal neutron detection for years. Starting in about 2001 the He-3 stockpile has been declining. The world is now experiencing the shortage of He-3. This makes the construction of large area detectors (several squared meters) not realistic anymore. A way to reduce the He-3 demand for those applications is to move users to alternative technologies, such as Boron-10. Although it is absolutely necessary to replace He-3 for large area applications, this is not the main issue for what concerns small area detectors for which the research is focused on improving their performances. Some technologies appear promising, though implementation would likely present technical challenges. There are several aspects that must be investigated in order to validate those new technologies; e.g. detection efficiency and gamma-ray sensitivity. Several detectors, based on Boron-10 layers, have been conceived, built and tested. We have laid a solid theoretical basis, confirmed by experiments, for the understanding of the main aspects of solid converter layers employed in neutron detectors. We also explored practically, by the construction and characterization of prototypes, a specific type of solid-converter-based neutron detector, the Multi-Blade, especially suited for application in neutron reflectometry.
△ Less
Submitted 12 June, 2014;
originally announced June 2014.
-
Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype
Authors:
F. Piscitelli,
J. C. Buffet,
J. F. Clergeau,
S. Cuccaro,
B. Guerard,
A. Khaplanov,
Q. La Manna,
J. M. Rigal,
P. Van Esch
Abstract:
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Lau…
▽ More
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade detector which wants to increase the spatial resolution of 3He-based detectors for high flux applications. We developed a high spatial resolution prototype suitable for neutron reflectometry instruments. It exploits solid 10B-films employed in a proportional gas chamber. Two prototypes have been constructed at ILL and the results obtained on our monochromatic test beam line are presented here.
△ Less
Submitted 9 December, 2013;
originally announced December 2013.
-
An Information-Theoretical Approach to Image Resolution Applied to Neutron Imaging Detectors based upon Individual Discriminator Signals
Authors:
Jean-François Clergeau,
Matthieu Ferraton,
Bruno Guérard,
Anton Khaplanov,
Francesco Piscitelli,
Martin Platz,
Jean-Marie Rigal,
Patrick Van Esch,
Thibault Daullé
Abstract:
1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlap** in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-li…
▽ More
1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlap** in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-like spots of neutron impacts with a given distance between them act as a source of information (each neutron hit belongs to one spot or the other), and the detector plus signal treatment is regarded as an imperfect communication channel that transmits this information. The maximal mutual information obtained from this channel as a function of the distance between the spots allows to define a calibration-independent measure of resolution. We then apply this measure to quantify the power of resolution of different algorithms treating these individual discriminator signals which can be implemented in firmware. The method is then applied to different detectors existing at the ILL. Center-of-gravity methods usually improve the resolution over best-wire algorithms which are the standard way of treating these signals.
△ Less
Submitted 29 July, 2013;
originally announced July 2013.
-
Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
Authors:
Anton Khaplanov,
Francesco Piscitelli,
Jean-Claude Buffet,
Jean-Francois Clergeau,
Jonathan Correa,
Patrick van Esch,
Mathieu Ferraton,
Bruno Guerard,
Richard Hall-Wilton
Abstract:
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to…
▽ More
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.
△ Less
Submitted 26 June, 2013;
originally announced June 2013.
-
Analytical modeling of thin film neutron converters and its application to thermal neutron gas detectors
Authors:
Francesco Piscitelli,
Patrick Van Esch
Abstract:
A simple model is explored mainly analytically to calculate and understand the PHS of single and multi-layer thermal neutron detectors and to help optimize the design in different circumstances. Several theorems are deduced that can help guide the design.
A simple model is explored mainly analytically to calculate and understand the PHS of single and multi-layer thermal neutron detectors and to help optimize the design in different circumstances. Several theorems are deduced that can help guide the design.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Multi-Grid Boron-10 detector for large area applications in neutron scattering science
Authors:
Ken Andersen,
Thierry Bigault,
Jens Birch,
Jean-Claude Buffet,
Jonathan Correa,
Patrick van Esch,
Bruno Guerard,
Richard Hall-Wilton,
Lars Hultman,
Carina Höglund,
Jens Jensen,
Anton Khaplanov,
Oliver Kirstein,
Francesco Piscitelli,
Christian Vettier
Abstract:
The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of cutting-edge instrumentation for neutron scattering science. In this context, 10B-based detectors are being developed by collaboration between the ESS, ILL, and…
▽ More
The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of cutting-edge instrumentation for neutron scattering science. In this context, 10B-based detectors are being developed by collaboration between the ESS, ILL, and Linkö** University. This paper reports on progress of this technology and the prospects applying it in modern neutron scattering experiments. The detector is made-up of multiple rectangular gas counter tubes coated with B4C, enriched in 10B. An anode wire reads out each tube, thereby giving position of conversion in one of the lateral co-ordinates as well as in depth of the detector. Position resolution in the remaining co-ordinate is obtained by segmenting the cathode tube itself. Boron carbide films have been produced at Linkö** University and a detector built at ILL. The characterization study is presented in this paper, including measurement of efficiency, effects of the fill gas species and pressure, coating thickness variation on efficiency and sensitivity to gamma-rays.
△ Less
Submitted 4 September, 2012;
originally announced September 2012.