-
Neutron lifetime measurements with the big gravitational trap for ultracold neutrons
Authors:
A. P. Serebrov,
E . A. Kolomensky,
A. K. Fomin,
I. A. Krasnoschekova,
A. V. Vassiljev,
D. M. Prudnikov,
I. V. Shoka,
A. V. Chechkin,
M. E. Chaikovskiy,
V. E. Varlamov,
S. N. Ivanov,
A. N. Pirozhkov,
P. Geltenbort,
O. Zimmer,
T. Jenke,
M. Van der Grinten,
M. Tucker
Abstract:
Neutron lifetime is one of the most important physical constants which determines parameters of the weak interaction and predictions of primordial nucleosynthesis theory. There remains the unsolved problem of a 3.9σ discrepancy between measurements of this lifetime using neutrons in beams and those with stored neutrons (UCN). In our experiment we measure the lifetime of neutrons trapped by Earth's…
▽ More
Neutron lifetime is one of the most important physical constants which determines parameters of the weak interaction and predictions of primordial nucleosynthesis theory. There remains the unsolved problem of a 3.9σ discrepancy between measurements of this lifetime using neutrons in beams and those with stored neutrons (UCN). In our experiment we measure the lifetime of neutrons trapped by Earth's gravity in an open-topped vessel. Two configurations of the trap geometry are used to change the mean frequency of UCN collisions with the surfaces - this is achieved by plunging an additional surface into the trap without breaking the vacuum. The trap walls are coated with a hydrogen-less fluorine-containing polymer to reduce losses of UCN. The stability of this coating to multiple thermal cycles between 80 K and 300 K was tested. At 80 K, the probability of UCN loss due to collisions with the trap walls is just 1.5% of the probability of beta-decay. The free neutron lifetime is determined by extrapolation to an infinitely large trap with zero collision frequency. The result of these measurements is 881.5 +/- 0.7_stat +/- 0.6_syst s which is consistent with the conventional value of 880.2 +/- 1.0 s presented by the Particle Data Group. Future prospects for this experiment are in further cooling to 10 K which will lead to an improved accuracy of measurement. In conclusion we present an analysis of currently-available data on various measurements of the neutron lifetime.
△ Less
Submitted 15 December, 2017;
originally announced December 2017.
-
New measurements of neutron electric dipole moment with double chamber EDM spectrometer
Authors:
A. P. Serebrov,
E. A. Kolomenskiy,
A. N. Pirozhkov,
I. A. Krasnoshekova,
A. V. Vasiliev,
A. O. Polyushkin,
M. S. Lasakov,
A. N. Murashkin,
V. A. Solovey,
A. K. Fomin,
I. V. Shoka,
O. M. Zherebtsov,
P. Geltenbort,
S. N. Ivanov,
O. Zimmer,
E. B. Alexandrov,
S. P. Dmitriev,
N. A. Dovator
Abstract:
The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.
The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
New measurements of neutron electric dipole moment
Authors:
A. P. Serebrov,
E. A. Kolomenskiy,
A. N. Pirozhkov,
I. A. Krasnoshekova,
A. V. Vasiliev,
A. O. Polyushkin,
M. S. Lasakov,
A. K. Fomin,
I. V. Shoka,
V. A. Solovey,
O. M. Zherebtsov,
P. Geltenbort,
O. Zimmer,
S. N. Ivanov,
E. B. Alexandrov,
S. P. Dmitriev,
N. A. Dovator
Abstract:
We report a new measurement of the neutron electric dipole moment with the PNPI EDM spectrometer using the ultracold neutron source PF2 at the research reactor of the ILL. Its first results can be interpreted as a limit on the neutron EDM of $|d_{\rm n}| < 5.5 \times 10^{-26} \rm{e} \cdot \rm{cm}$ (90% confidence level).
We report a new measurement of the neutron electric dipole moment with the PNPI EDM spectrometer using the ultracold neutron source PF2 at the research reactor of the ILL. Its first results can be interpreted as a limit on the neutron EDM of $|d_{\rm n}| < 5.5 \times 10^{-26} \rm{e} \cdot \rm{cm}$ (90% confidence level).
△ Less
Submitted 16 December, 2013; v1 submitted 21 October, 2013;
originally announced October 2013.
-
Search for macroscopic CP violating forces using a neutron EDM spectrometer
Authors:
A. P. Serebrov,
O. Zimmer,
P. Geltenbort,
A. K. Fomin,
S. N. Ivanov,
E. A. Kolomensky,
I. A. Krasnoshekova,
M. S. Lasakov,
V. M. Lobashev,
A. N. Pirozhkov,
V. E. Varlamov,
A. V. Vasiliev,
O. M. Zherebtsov,
E. B. Aleksandrov,
S. P. Dmitriev,
N. A. Dovator
Abstract:
The search for CP violating forces between nucleons in the so-called axion window of force ranges lam between 2x10^-5 m and 0.02 m is interesting because only little experimental information is available there. Axion-like particles would induce a pseudo-magnetic field for neutrons close to bulk matter. A laboratory search investigates neutron spin precession close to a heavy mirror using ultraco…
▽ More
The search for CP violating forces between nucleons in the so-called axion window of force ranges lam between 2x10^-5 m and 0.02 m is interesting because only little experimental information is available there. Axion-like particles would induce a pseudo-magnetic field for neutrons close to bulk matter. A laboratory search investigates neutron spin precession close to a heavy mirror using ultracold neutrons in a magnetic resonance spectrometer. From the absence of a shift of the magnetic resonance we established new constraints on the coupling strength of axion-like particles in terms of the product gs x gp of scalar and pseudo-scalar dimensionless constants, as a function of the force range lam, gs x gp x lam^2 <= 2x10-21 [cm^2] (C.L.95%) for 10^-4 cm < lam < 1 cm. For 0.1 cm < lam < 1 cm previous limits are improved by 4 to 5 orders of magnitude.
△ Less
Submitted 11 December, 2009;
originally announced December 2009.