-
New insights on fission of $^{235}$U induced by high energy neutrons from a new measurement at CERN n\_TOF
Authors:
Alice Manna,
Elisa Pirovano,
the n\_TOF Collaboration
Abstract:
The $^{235}$U(n,f) reaction cross section was measured relative to neutron-proton elastic scattering for the first time in the energy region from 10 MeV to 440 MeV at the CERN n\_TOF facility, extending the upper limit of the only previous measurement in the literature by more than 200 MeV. Two independent detection systems were used simultaneously to extract the fission cross section. For neutron…
▽ More
The $^{235}$U(n,f) reaction cross section was measured relative to neutron-proton elastic scattering for the first time in the energy region from 10 MeV to 440 MeV at the CERN n\_TOF facility, extending the upper limit of the only previous measurement in the literature by more than 200 MeV. Two independent detection systems were used simultaneously to extract the fission cross section. For neutron energies below 200 MeV, the present results agree within one standard deviation with the data available in literature and are well reproduced by the IAEA evaluation. Above 200 MeV, the comparison of model calculations to the present data indicates the need to introduce a transient time in the description of the neutron-induced fission process in order to allow the simultaneous description of (n,f) and (p,f) reactions.
△ Less
Submitted 14 June, 2024; v1 submitted 18 March, 2024;
originally announced March 2024.
-
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
Authors:
J. Balibrea Correa,
J. Lerendegui-Marco,
V. Babiano-Suarez,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
A. Pérez de Rada,
J. Plaza del Olmo,
A. Sánchez-Caballero,
A. Casanovas,
F. Calviño,
S. Valenta,
O. Aberle,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes
, et al. (109 additional authors not shown)
Abstract:
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects…
▽ More
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility
Authors:
J. Balibrea-Correa,
V. Babiano-Suarez,
J. Lerendegui-Marco,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
J. Plaza,
A. Sánchez-Caballero,
F. Calviño,
A. Casanovas,
C. Guerrero,
S. Heinitz,
U. Köster,
E. A. Maugeri,
R. Dressler,
D. Schumann,
I. Mönch,
S. Cristallo,
C. Lederer-Woods,
O. Aberle
, et al. (112 additional authors not shown)
Abstract:
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along di…
▽ More
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.
△ Less
Submitted 20 February, 2023; v1 submitted 26 January, 2023;
originally announced January 2023.
-
A detector system for 'absolute' measurements of fission cross sections at n_TOF in the energy range below 200 MeV
Authors:
E. Pirovano,
A. Manna,
O. Aberle,
S. Amaducci,
N. Colonna,
P. Console Camprini,
L. Cosentino,
M. Dietz,
Q. Ducasse,
P. Finocchiaro,
C. Massimi,
A. Mengoni,
R. Nolte,
D. Radeck,
L. Tassan-Got,
N. Terranova,
G. Vannini
Abstract:
A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron scattering on hydrogen. This is a measurement first of its kind at this facility, in an energy range that was until now not often explored, so the detector development p…
▽ More
A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron scattering on hydrogen. This is a measurement first of its kind at this facility, in an energy range that was until now not often explored, so the detector development phase was crucial for its success. Two detectors are presented, a parallel plate fission chamber (PPFC) and a recoil proton telescope (RPT), both dedicated to perform measurements in the incident neutron energy range from 30 MeV to 200 MeV. The experiment was designed to minimize statistical uncertainties in the allocated run time. Several efforts were made to ensure that the systematic effects were understood and under control. The results show that the detectors are suited for measurements at n_TOF above 30 MeV, and indicate the path for possible future lines of development.
△ Less
Submitted 28 November, 2022; v1 submitted 22 November, 2022;
originally announced November 2022.
-
Recoil Proton Telescopes and Parallel Plate Avalanche Counters for the $^{235}$U(n,f) cross section measurement relative to H(n,n)H between 10 and 450 MeV neutron energy
Authors:
A. Manna,
E. Pirovano,
O. Aberle,
S. Amaducci,
M. Barbagallo,
D. M. Castelluccio,
N. Colonna,
P. Console Camprini,
L. Cosentino,
M. Dietz,
Q. Ducasse,
P. Finocchiaro,
C. Le Naour,
S. Lo Meo,
M. Mastromarco,
C. Massimi,
A. Mengoni,
P. M. Milazzo,
F. Mingrone,
R. Nolte,
M. Piscopo,
D. Radeck,
M. Spelta,
L. Tassan-Got,
N. Terranova
, et al. (1 additional authors not shown)
Abstract:
With the aim of measuring the $^{235}$U(n,f) cross section at the n\_TOF facility at CERN over a wide neutron energy range, a detection system consisting of two fission detectors and three detectors for neutron flux determination was realized. The neutron flux detectors are Recoil Proton Telescopes (RPT), based on scintillators and solid state detectors, conceived to detect recoil protons from the…
▽ More
With the aim of measuring the $^{235}$U(n,f) cross section at the n\_TOF facility at CERN over a wide neutron energy range, a detection system consisting of two fission detectors and three detectors for neutron flux determination was realized. The neutron flux detectors are Recoil Proton Telescopes (RPT), based on scintillators and solid state detectors, conceived to detect recoil protons from the neutron-proton elastic scattering reaction. This system, along with a fission chamber and an array of parallel plate avalanche counters for fission event detection, was installed for the measurement at the n\_TOF facility in 2018, at CERN.
An overview of the performances of two RPTs - especially developed for this measurement - and of the parallel plate avalanche counters are described in this article. In particular, the characterization in terms of detection efficiency by Monte Carlo simulations and response to neutron beam, the study of the background, dead time correction and characterization of the samples, are reported. The results of the present investigation show that the performances of these detectors are suitable for accurate measurements of fission reaction cross sections in the range from 10 to 450~MeV.
△ Less
Submitted 18 January, 2023; v1 submitted 22 November, 2022;
originally announced November 2022.
-
The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements
Authors:
N. Patronis,
A. Mengoni,
N. Colonna,
M. Cecchetto,
C. Domingo-Pardo,
O. Aberle,
J. Lerendegui-Marco,
G. Gervino,
M. E. Stamati,
S. Goula,
A. P. Bernardes,
M. Mastromarco,
A. Manna,
R. Vlastou,
C. Massimi,
M. Calviani,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea,
C. Beltrami,
S. Bennett
, et al. (108 additional authors not shown)
Abstract:
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to th…
▽ More
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
Authors:
C. Domingo-Pardo,
V. Babiano-Suarez,
J. Balibrea-Correa,
L. Caballero,
I. Ladarescu,
J. Lerendegui-Marco,
J. L. Tain,
A. Tarifeño-Saldivia,
O. Aberle,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes,
E. Berthoumieux,
M. Boromiza,
D. Bosnar,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
A. Casanovas
, et al. (114 additional authors not shown)
Abstract:
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also prese…
▽ More
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Direct measurement of the ionization quenching factor of nuclear recoils in germanium in the keV energy range
Authors:
A. Bonhomme,
H. Bonet,
C. Buck,
J. Hakenmüller,
G. Heusser,
T. Hugle,
M. Lindner,
W. Maneschg,
R. Nolte,
T. Rink,
E. Pirovano,
H. Strecker
Abstract:
This article reports the measurement of the ionization quenching factor in germanium for nuclear recoil energies between 0.4 and 6.3 keV$_{nr}$. Precise knowledge of this factor in this energy range is relevant for coherent elastic neutrino-nucleus scattering and low mass dark matter searches with germanium-based detectors. Nuclear recoils were produced in a thin high-purity germanium target with…
▽ More
This article reports the measurement of the ionization quenching factor in germanium for nuclear recoil energies between 0.4 and 6.3 keV$_{nr}$. Precise knowledge of this factor in this energy range is relevant for coherent elastic neutrino-nucleus scattering and low mass dark matter searches with germanium-based detectors. Nuclear recoils were produced in a thin high-purity germanium target with a very low energy threshold via irradiation with monoenergetic neutron beams. The energy dependence of the ionization quenching factor was directly measured via kinematically constrained coincidences with surrounding liquid scintillator based neutron detectors. The systematic uncertainties of the measurements are discussed in detail. With measured quenching factors between 0.16 and 0.23 in the [0.4, 6.3] keV$_{nr}$ energy range, the data are compatible with the Lindhard theory with a parameter $k$ of 0.162 $\pm$ 0.004 (stat+sys).
△ Less
Submitted 19 September, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques
Authors:
V. Babiano-Suárez,
J. Lerendegui-Marco,
J. Balibrea-Correa,
L. Caballero,
D. Calvo,
I. Ladarescu,
C. Domingo-Pardo,
F. Calviño,
A. Casanovas,
A. Tarifeño-Saldivia,
V. Alcayne,
C. Guerrero,
M. A. Millán-Callado,
M. T. Rodríguez González,
M. Barbagallo,
O. Aberle,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
M. Bacak,
S. Bennett,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown
, et al. (110 additional authors not shown)
Abstract:
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background reje…
▽ More
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,γ$) and $^{56}$Fe($n, γ$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.
△ Less
Submitted 18 December, 2020;
originally announced December 2020.
-
Review and new concepts for neutron-capture measurements of astrophysical interest
Authors:
C. Domingo-Pardo,
V. Babiano-Suarez,
J. Balibrea-Correa,
L. Caballero,
I. Ladarescu,
J. Lerendegui-Marco,
J. L. Tain,
F. Calviño,
A. Casanovas,
A. Segarra,
A. E. Tarifeño-Saldivia,
C. Guerrero,
M. A. Millán-Callado,
J. M. Quesada,
M. T. Rodríguez-González,
O. Aberle,
V. Alcayne,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
M. Bacak,
M. Barbagallo,
S. Bennett,
E. Berthoumieux,
D. Bosnar
, et al. (106 additional authors not shown)
Abstract:
The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear physics input quantities, namely ($n,γ$) cross sections over the stellar temperature range (from few eV up to several hundred keV) for most of the isotopes involved from Fe up to Bi. A brief historical review focused on t…
▽ More
The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear physics input quantities, namely ($n,γ$) cross sections over the stellar temperature range (from few eV up to several hundred keV) for most of the isotopes involved from Fe up to Bi. A brief historical review focused on total energy detectors will be presented to illustrate how, advances in instrumentation have led, over the years, to the assessment and discovery of many new aspects of $s$-process nucleosynthesis and to the progressive refinement of theoretical models of stellar evolution. A summary will be presented on current efforts to develop new detection concepts, such as the Total-Energy Detector with $γ$-ray imaging capability (i-TED). The latter is based on the simultaneous combination of Compton imaging with neutron time-of-flight (TOF) techniques, in order to achieve a superior level of sensitivity and selectivity in the measurement of stellar neutron capture rates.
△ Less
Submitted 16 November, 2019;
originally announced November 2019.
-
Calibration of the compact neutron spectrometer at PTB
Authors:
M. Osipenko,
V. Ceriale,
G. Gariano,
M. Girolami,
S. Cerchi,
R. Nolte,
E. Pirovano,
M. Ripani,
D. M. Trucchi
Abstract:
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2…
▽ More
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2, 100 um thick single crystal CVD commercial diamond plates. The measurements were performed in the fission spectrum domain at five different neutron energies varying from 0.3 up to 2 MeV. The obtained data showed a very good neutron energy reconstruction, i.e. in agreement with its reference values within statistical uncertainties or with deviation below 11 keV in absolute scale. The energy resolution of the spectrometer was found to be about 100 keV (RMS) with a small (about 9 keV/MeV) rising trend towards higher energies. The measured detection efficiency was found to be compatible with expectations based on analytical calculations and on Geant4 simulations within 3% statistical and 4% systematic precision.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.