Simulating Modulated X-ray calibration Sources for future X-ray missions, using GEANT4
Authors:
C. P. de Vries,
V. Fioretti,
J. W. den Herder,
E Schyns,
S. D. Pinto
Abstract:
The XIFU X-ray spectrometer instrument on the future Athena mission needs X-ray calibration sources to calibrate the gains of the individual detector pixels. For this purpose, electronically controlled Modulated X-ray Sources (MXS) are proposed, similar to the calibrations sources used on the Hitomi spacecraft and which will also fly on its successor, XARM. Here we present a simulation package bas…
▽ More
The XIFU X-ray spectrometer instrument on the future Athena mission needs X-ray calibration sources to calibrate the gains of the individual detector pixels. For this purpose, electronically controlled Modulated X-ray Sources (MXS) are proposed, similar to the calibrations sources used on the Hitomi spacecraft and which will also fly on its successor, XARM. Here we present a simulation package based on the particle transport GEANT4 toolkit. Using this package, we compute the results for different targets and window configurations for the MXS's. The simulations expose the trade-offs to be made to select the optimum source configuration for the Athena/XIFU and XARM/Resolve spectrometer instruments.
△ Less
Submitted 20 June, 2018;
originally announced June 2018.
-
High collection efficiency MCPs for photon counting detectors
Authors:
D. A. Orlov,
T. Ruardij,
S. Duarte Pinto,
R. Glazenborg,
E. Kernen
Abstract:
Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected; this is in contrast to conventional MCPs where about 50% of photoelectrons are lost at the MCP stage. The drawback of the Hi-CE MCPs is a small degradation of the…
▽ More
Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected; this is in contrast to conventional MCPs where about 50% of photoelectrons are lost at the MCP stage. The drawback of the Hi-CE MCPs is a small degradation of the transfer time spread (TTS). However for applications where no sub-ns time resolution is required the implementation of Hi-CE MCPs is extremely beneficial, as it improves the detection efficiency of the MCP-PMT almost by a factor of two.
△ Less
Submitted 15 December, 2017; v1 submitted 10 November, 2017;
originally announced November 2017.
-
Neutron imaging and tomography with MCPs
Authors:
Serge Duarte Pinto,
Raquel Ortega,
Steve Ritzau,
David Pasquale,
Bruce Laprade,
Sharon Mrotek,
Sean Gardell,
Zhou Zhou,
Jeroen Plomp,
Lambert van Eijck,
Hassina Bilheux,
Indu Dhiman
Abstract:
A neutron imaging detector based on neutron-sensitive microchannel plates (MCPs) was constructed and tested at beamlines of thermal and cold neutrons. The MCPs are made of a glass mixture containing B-10 and natural Gd, which makes the bulk of the MCP an efficient neutron converter. Contrary to the neutron sensitive scintillator screens normally used in neutron imaging, spatial resolution is not t…
▽ More
A neutron imaging detector based on neutron-sensitive microchannel plates (MCPs) was constructed and tested at beamlines of thermal and cold neutrons. The MCPs are made of a glass mixture containing B-10 and natural Gd, which makes the bulk of the MCP an efficient neutron converter. Contrary to the neutron sensitive scintillator screens normally used in neutron imaging, spatial resolution is not traded off with detection efficiency. While the best neutron imaging scintillators have a detection efficiency around a percent, a detection efficiency of around 50% for thermal neutrons and 70% for cold neutrons has been demonstrated with these MCPs earlier.
Our tests show a performance similar to conventional neutron imaging detectors, apart from the orders of magnitude better sensitivity. We demonstrate a spatial resolution better than 150 um. The sensitivity of this detector allows fast tomography and neutron video recording, and will make smaller reactor sites and even portable sources suitable for neutron imaging.
△ Less
Submitted 2 November, 2017; v1 submitted 6 October, 2017;
originally announced October 2017.
-
High quantum efficiency S-20 photocathodes in photon counting detectors
Authors:
Dmitry A. Orlov,
Jeff DeFazio,
Serge Duarte Pinto,
Rene Glazenborg,
Emilie Kernen
Abstract:
Based on conventional S-20 processes, a new series of high quantum efficiency (QE) photocathodes has been developed that can be specifically tuned for use in the ultraviolet, blue or green regions of the spectrum. The QE values exceed 30% at maximum response, and the dark count rate is found to be as low as 30 Hz/cm$^2$ at room temperature. This combination of properties along with a fast temporal…
▽ More
Based on conventional S-20 processes, a new series of high quantum efficiency (QE) photocathodes has been developed that can be specifically tuned for use in the ultraviolet, blue or green regions of the spectrum. The QE values exceed 30% at maximum response, and the dark count rate is found to be as low as 30 Hz/cm$^2$ at room temperature. This combination of properties along with a fast temporal response makes these photocathodes ideal for application in photon counting detectors, which is illustrated with an MCP photomultiplier tube for single and multi-photoelectron detection.
△ Less
Submitted 26 April, 2016; v1 submitted 14 March, 2016;
originally announced March 2016.
-
Concept for a Time-of-Flight Small Angle Neutron Scattering Instrument at the European Spallation Source
Authors:
S. Jaksch,
D. Martin-Rodriguez,
A. Ostermann,
J. Jestin,
S. Duarte Pinto,
W. G. Bouwman,
J. Uher,
R. Engels,
G. Kemmerling,
R. Hanslik,
H. Frielinghaus
Abstract:
A new Small Angle Neutron Scattering instrument is proposed for the European Spallation Source. The pulsed source requires a time-of-flight analysis of the gathered neutrons at the detector. The optimal instrument length is found to be rather large, which allows for a polarizer and a versatile collimation. The polarizer allows for studying magnetic samples and incoherent background subtraction. Th…
▽ More
A new Small Angle Neutron Scattering instrument is proposed for the European Spallation Source. The pulsed source requires a time-of-flight analysis of the gathered neutrons at the detector. The optimal instrument length is found to be rather large, which allows for a polarizer and a versatile collimation. The polarizer allows for studying magnetic samples and incoherent background subtraction. The wide collimation will host VSANS and SESANS options that increase the resolution of the instrument towards um and tens of um, respectively. Two 1m2 area detectors will cover a large solid angle simultaneously. The expected gains for this new instrument will lie in the range between 20 and 36, depending on the assessment criteria, when compared to up-to-date reactor based instruments. This will open new perspectives for fast kinetics, weakly scattering samples, and multi-dimensional contrast variation studies.
△ Less
Submitted 11 March, 2014;
originally announced March 2014.
-
Gas Electron Multipliers versus Multiwire Proportional Chambers
Authors:
Serge Duarte Pinto,
Jens Spanggaard
Abstract:
Gas Electron Multiplication technology is finding more and more applications in beam instrumentation and at CERN these detectors have recently been adapted for use in transverse profile measurements at several of our facilities. In the experimental areas of CERN's Antiproton Decelerator, low energy Gas Electron Multipliers successfully replaced all Multwire Proportional Chambers in 2012 and anothe…
▽ More
Gas Electron Multiplication technology is finding more and more applications in beam instrumentation and at CERN these detectors have recently been adapted for use in transverse profile measurements at several of our facilities. In the experimental areas of CERN's Antiproton Decelerator, low energy Gas Electron Multipliers successfully replaced all Multwire Proportional Chambers in 2012 and another detector type has now been developed for high energy applications in the experimental areas of the SPS, totaling a potential of more than a hundred profile detectors to be replaced by GEM detectors of different types. This paper aims to describe the historical evolution of GEM technology by covering the many different applications but with specific focus on its potential to replace Multiwire Proportional Chambers for standard transverse profile measurement.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.
-
GEM applications outside high energy physics
Authors:
Serge Duarte Pinto
Abstract:
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these applications will be explained in principle and practice.
This paper reviews applications in research, beam instrumentation and homeland security. The detectors…
▽ More
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these applications will be explained in principle and practice.
This paper reviews applications in research, beam instrumentation and homeland security. The detectors described measure neutral radiations such as photons, x-rays, gamma rays and neutrons, as well as all kinds of charged radiation. This paper provides an overview of the still expanding range of possibilities of this versatile detector concept.
△ Less
Submitted 7 February, 2013;
originally announced February 2013.
-
Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
Y. Assran,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti,
L. Franconi
, et al. (34 additional authors not shown)
Abstract:
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly t…
▽ More
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly technique, we built four full-scale Triple-GEM muon detectors for the inner ring of the first muon endcap station. We plan to install these or further improved versions in CMS during the first long LHC shutdown in 2013/14 for continued testing. These detectors are designed for the stringent rate and resolution requirements in the increasingly hostile environments expected at CMS after the second long LHC shutdown in 2018/19. The new prototypes were studied in muon/pion beams at the CERN SPS. We discuss our experience with constructing the new full-scale production prototypes and present preliminary performance results from the beam test. We also tested smaller Triple-GEM prototypes with zigzag readout strips with 2 mm pitch in these beams and measured a spatial resolution of 73 microns. This readout offers a potential reduction of channel count and consequently electronics cost for this system while maintaining high spatial resolution.
△ Less
Submitted 16 November, 2012;
originally announced November 2012.
-
Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System
Authors:
M. Tytgat,
A. Marinov,
N. Zaganidis,
Y. Ban,
J. Cai,
H. Teng,
A. Mohapatra,
T. Moulik,
M. Abbrescia,
A. Colaleo,
G. de Robertis,
F. Loddo,
M. Maggi,
S. Nuzzo,
S. A. Tupputi,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Raffone,
G. Saviano,
M. G. Bagliesi,
R. Cecchi,
G. Magazzu,
E. Oliveri
, et al. (34 additional authors not shown)
Abstract:
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete…
▽ More
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
M. G. Bagliesi,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
R. Cecchi,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti
, et al. (33 additional authors not shown)
Abstract:
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const…
▽ More
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detector, which is able to meet the stringent requirements given the hostile environment at the high-luminosity LHC. Measurements were performed during several test beam campaigns at the CERN SPS in 2010 and 2011. The main issues under study are efficiency, spatial resolution and timing performance with different inter-electrode gap configurations and gas mixtures. In this paper results of the performance of the prototypes at the beam tests will be discussed.
△ Less
Submitted 30 November, 2011; v1 submitted 21 November, 2011;
originally announced November 2011.
-
Antiproton beam profile measurements using Gas Electron Multipliers
Authors:
Serge Duarte Pinto,
Philippe Carrière,
Jens Spanggaard,
Gerard Tranquille
Abstract:
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions wi…
▽ More
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEgIS beam lines. We will provide a detailed description of the detector and discuss the results obtained.
The success of these detectors in the AD makes GEM-based detectors likely candidates for upgrade of the beam profile monitors in all experimental areas at CERN. The various types of MWPC currently in use are aging and becoming increasingly difficult to maintain.
△ Less
Submitted 17 November, 2011;
originally announced November 2011.
-
GEM-based beam profile monitors for the antiproton decelerator
Authors:
Serge Duarte Pinto,
Rhodri Jones,
Leszek Ropelewski,
Jens Spanggaard,
Gerard Tranquille
Abstract:
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions wit…
▽ More
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEGIS beam lines. We will provide a detailed description of the detector and discuss the results obtained.
The success of these detectors in the AD makes GEM-based detectors likely candidates for upgrade of the beam profile monitors in all experimental areas at CERN. The various types of MWPC currently in use are aging and becoming increasingly difficult to maintain.
△ Less
Submitted 14 November, 2011;
originally announced November 2011.
-
Gas Electron Multipliers for the Antiproton Decelerator
Authors:
Serge Duarte Pinto,
Rhodri Jones,
Leszek Ropelewski,
Jens Spanggaard,
Gerard Tranquille
Abstract:
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical profiles directly in one plane. This overcomes the problems previously encountered with multi-wire proportional chambers for the same purpose, where beam interactions…
▽ More
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical profiles directly in one plane. This overcomes the problems previously encountered with multi-wire proportional chambers for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEGIS beam lines. This paper will provide a detailed description of the detector and discuss the results obtained.
△ Less
Submitted 24 May, 2011;
originally announced May 2011.
-
Characterization of GEM Detectors for Application in the CMS Muon Detection System
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
E. David,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Saviano,
N. Turini,
E. Oliveri,
G. Magazzu',
A. Marinov,
M. Tytgat,
N. Zaganidis,
M. Hohlmann
, et al. (4 additional authors not shown)
Abstract:
The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with…
▽ More
The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with the very forward detector region remaining uncovered. In view of a possible future extension of the muon endcap system, we report on a feasibility study on the use of Micro-Pattern Gas Detectors, in particular Gas Electron Multipliers, for both muon triggering and tracking. Results on the construction and characterization of small tripleGas Electron Multiplier prototype detectors are presented.
△ Less
Submitted 16 December, 2010;
originally announced December 2010.
-
Construction of the first full-size GEM-based prototype for the CMS high-$η$ muon system
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. Van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. Fabbri,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
A. Marinov,
M. Tytgat,
N. Zaganidis
, et al. (10 additional authors not shown)
Abstract:
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the…
▽ More
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the design and construction of a full-size prototype for the CMS endcap system, the largest Triple-GEM detector built to-date. We present details on the 3D modeling of the detector geometry, the implementation of the readout strips and electronics, and the detector assembly procedure.
△ Less
Submitted 9 December, 2010; v1 submitted 7 December, 2010;
originally announced December 2010.
-
Micropattern gas detector technologies and applications, the work of the RD51 collaboration
Authors:
Serge Duarte Pinto
Abstract:
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 75 institutes from 25 countries bundle their effort, experience and resources to develop these emerging micropattern technologies.
MPGDs are already employed in several nuclear and high-energy physics experiments, medical imaging instruments and pho…
▽ More
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 75 institutes from 25 countries bundle their effort, experience and resources to develop these emerging micropattern technologies.
MPGDs are already employed in several nuclear and high-energy physics experiments, medical imaging instruments and photodetection applications; many more applications are foreseen. They outperform traditional wire chambers in terms of rate capability, time and position resolution, granularity, stability and radiation hardness. RD51 supports efforts to make MPGDs also suitable for large areas, increase cost-efficiency, develop portable detectors and improve ease-of-use.
The collaboration is organized in working groups which develop detectors with new geometries, study and simulate their properties, and design optimized electronics. Among the common supported projects are creation of test infrastructure such as beam test and irradiation facilities, and the production workshop.
△ Less
Submitted 24 November, 2010;
originally announced November 2010.
-
First results of spherical GEMs
Authors:
Serge Duarte Pinto,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis,
Hans Taureg,
Marco Villa
Abstract:
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at w…
▽ More
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles.
Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the limit of the angular acceptance of the detector. With these components first tests are done in a setup with a spherical entrance window but a planar readout structure; results will be presented and discussed.
A flat readout structure poses difficulties, however. Therefore we will show advanced plans to make a prototype of an entirely spherical double-GEM detector, including a spherical 2D readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability.
△ Less
Submitted 24 November, 2010;
originally announced November 2010.
-
Progress on large area GEMs (VCI 2010)
Authors:
Marco Villa,
Serge Duarte Pinto,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Hans Taureg,
Miranda van Stenis
Abstract:
The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in lar…
▽ More
The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in large area GEMs have also been addressed. Using the new improvements it was possible to build a prototype triple-GEM detector of ~ 2000 cm2 active area, aimed at an application for the TOTEM T1 upgrade. Further refinements of the single mask technique give great control over the shape of the GEM holes and the size of the rims, which can be tuned as needed. In this framework, simulation studies can help to understand the GEM behavior depending on the hole shape.
△ Less
Submitted 7 July, 2010;
originally announced July 2010.
-
Spherical GEMs for parallax-free detectors
Authors:
Serge Duarte Pinto,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis,
Hans Taureg,
Marco Villa
Abstract:
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial…
▽ More
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. The method is inexpensive and flexible towards possible changes in the design.
We show advanced plans to make a prototype of an entirely spherical triple-GEM detector, including a spherical readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability. A completely spherical gaseous detector has never been made before.
△ Less
Submitted 17 November, 2009;
originally announced November 2009.
-
Progress on large area GEMs
Authors:
Serge Duarte Pinto,
Marco Villa,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis
Abstract:
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development.
A single-mask technique overcomes the cumbersome p…
▽ More
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development.
A single-mask technique overcomes the cumbersome practice of alignment of two masks, which limits the achievable lateral size. The holes obtained with this technique are conical, and have a so-called rim, a small insulating clearance around the hole in the substrate. Further refinements of this technique allow greater control over the shape of holes and the size of rims. Also, an improvement in homogeneity over large areas is expected.
Simulation studies have been done to examine the effect of hole shape on the behavior of GEMs. Such studies can help understanding how to use new enhancements of the technique to optimize performance.
Many potential applications for large area GEMs foresee large production volumes. Production issues have been studied, and single-mask GEMs turn out to be much more suitable for large scale production than standard GEMs.
△ Less
Submitted 26 November, 2009; v1 submitted 28 September, 2009;
originally announced September 2009.
-
Making spherical GEMs
Authors:
Serge Duarte Pinto,
Marco Villa,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis,
Hans Taureg
Abstract:
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap for x-rays can be formed. This would eliminate the parallax error in an x-ray diffraction setup, which limits the spatial resolution at wide diffraction angles. The method is inexpensi…
▽ More
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap for x-rays can be formed. This would eliminate the parallax error in an x-ray diffraction setup, which limits the spatial resolution at wide diffraction angles. The method is inexpensive and flexible towards possible changes in the design.
We show advanced plans to make a prototype of an entirely spherical triple-GEM detector, including a spherical readout structure. This detector will have a superior position resolution, also at wide diffraction angles, and a high rate capability. A completely spherical gaseous detector has never been made before.
△ Less
Submitted 6 November, 2009; v1 submitted 18 September, 2009;
originally announced September 2009.
-
RD51, an R&D collaboration for micropattern gaseous detectors
Authors:
Serge Duarte Pinto
Abstract:
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 59 institutes from 20 countries bundle their effort, experience and resources to develop these emerging micropattern technologies.
MPGDs are already employed in several nuclear and high-energy physics experiments, medical imaging instruments and p…
▽ More
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 59 institutes from 20 countries bundle their effort, experience and resources to develop these emerging micropattern technologies.
MPGDs are already employed in several nuclear and high-energy physics experiments, medical imaging instruments and photodetection applications; many more applications are foreseen. They outperform traditional wire chambers in terms of rate capability, time and position resolution, granularity, stability and radiation hardness. RD51 supports efforts to make MPGDs also suitable for large areas, increase cost-efficiency, develop portable detectors and improve ease-of-use.
The collaboration is organized in working groups which develop detectors with new geometries, study and simulate their properties, and design optimized electronics. Among the common supported projects are creation of test infrastructure such as beam test and irradiation facilities, and the production workshop.
△ Less
Submitted 16 July, 2009; v1 submitted 15 July, 2009;
originally announced July 2009.