-
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Authors:
Didier Barret,
Vincent Albouys,
Jan-Willem den Herder,
Luigi Piro,
Massimo Cappi,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Stéphane Paltani,
Gregor Rauw,
Agata Rozanska,
Jiri Svoboda,
Joern Wilms,
Noriko Yamasaki,
Marc Audard,
Simon Bandler,
Marco Barbera,
Xavier Barcons,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Elisa Costantini,
Thomas Dauser,
Anne Decourchelle,
Lionel Duband
, et al. (274 additional authors not shown)
Abstract:
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide sp…
▽ More
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).
△ Less
Submitted 28 November, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
The Infra-Red Telescope (IRT) on board the THESEUS mission
Authors:
Diego Götz,
Stéphane Basa,
Frédéric Pinsard,
Laurent Martin,
Axel Arhancet,
Enrico Bozzo,
Christophe Cara,
Isabel Escudero Sanz,
Pierre-Antoine Frugier,
Johan Floriot,
Ludovic Genolet,
Paul Heddermann,
Emeric Le Floc'h,
Isabelle Le Mer,
Stéphane Paltani,
Tony Pamplona,
Céline Paries,
Thibaut Prod'homme,
Benjamin Schneider,
Chris Tenzer,
Thierry Tourrette,
Henri Triou
Abstract:
The Infra-Red Telescope (IRT) is part of the payload of the THESEUS mission, which is one of the two ESA M5 candidates within the Cosmic Vision program, planned for launch in 2032. The THESEUS payload, composed by two high energy wide field monitors (SXI and XGIS) and a near infra-red telescope (IRT), is optimized to detect, localize and characterize Gamma-Ray Bursts and other high-energy transien…
▽ More
The Infra-Red Telescope (IRT) is part of the payload of the THESEUS mission, which is one of the two ESA M5 candidates within the Cosmic Vision program, planned for launch in 2032. The THESEUS payload, composed by two high energy wide field monitors (SXI and XGIS) and a near infra-red telescope (IRT), is optimized to detect, localize and characterize Gamma-Ray Bursts and other high-energy transients. The main goal of the IRT is to identify and precisely localize the NIR counterparts of the high-energy sources and to measure their distance. Here we present the design of the IRT and its expected performance.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
IDeF-X HD: a CMOS ASIC for the readout of Cd(Zn)Te Detectors for space-borne applications
Authors:
Olivier Gevin,
Francis Lugiez,
Alicja Michalowska,
Aline Meuris,
Olivier Limousin,
Eric Delagnes,
Olivier Lemaire,
Frédéric Pinsard
Abstract:
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to t…
▽ More
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after sha** with 10.7 micro seconds peak time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2 keV FWHM at 667 keV (137-Cs) on a mono-pixel configuration. Meanwhile, we also measured 562 eV and 666 eV FWHM at 14 keV and 60 keV respectively (241-Am) with a 256 small pixel array and a low detection threshold of 1.2 keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the Linear Energy Transfer threshold above 110 MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high-energy resolution. The chip is space qualified and flies on board the Solar Orbiter ESA mission launched in 2020.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.
-
The Infra-Red Telescope on board the THESEUS mission
Authors:
D. Götz,
O. Boulade,
B. Cordier,
E. Le Floc'h,
F. Pinsard,
J. Amiaux,
T. Tourrette,
S. Basa,
S. Vergani,
J. L. Atteia,
S. Covino,
G. Ghirlanda,
N. Tanvir,
A. Blain,
P. O'Brien,
A. Rossi,
G. Stratta,
P. G. Casella,
E. Bozzo,
C. Tenzer,
P. Orleanski,
L. Amati
Abstract:
The Infra-Red Telescope (IRT) on board the Transient High Energy Sky and Early Universe Surveyor (THESEUS) ESA M5 candidate mission will play a key role in identifying and characterizing moderate to high redshift Gamma-Ray Bursts afterglows. The IRT is the enabling instrument on board THESEUS for measuring autonomously the redshift of the several hundreds of GRBs detected per year by the Soft X-ra…
▽ More
The Infra-Red Telescope (IRT) on board the Transient High Energy Sky and Early Universe Surveyor (THESEUS) ESA M5 candidate mission will play a key role in identifying and characterizing moderate to high redshift Gamma-Ray Bursts afterglows. The IRT is the enabling instrument on board THESEUS for measuring autonomously the redshift of the several hundreds of GRBs detected per year by the Soft X-ray Imager (SXI) and the X- and Gamma-Ray Imaging Spectrometer (XGIS), and thus allowing the big ground based telescopes to be triggered on a redshift pre-selected sample, and finally fulfilling the cosmological goals of the mission. The IRT will be composed by a primary mirror of 0.7 m of diameter coupled to a single camera in a Cassegrain design. It will work in the 0.7-1.8 μm wavelength range, and will provide a 10x10 arc min imaging field of view with sub-arc second localization capabilities, and, at the same time, a 5x5 arc min field of view with moderate (R up to ~500) spectroscopic capabilities. Its sensitivity, mainly limited by the satellite jitter, is adapted to detect all the GRBs, localized by the SXI/XGIS, and to acquire spectra for the majority of them.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
The EChO science case
Authors:
Giovanna Tinetti,
Pierre Drossart,
Paul Eccleston,
Paul Hartogh,
Kate Isaak,
Martin Linder,
Christophe Lovis,
Giusi Micela,
Marc Ollivier,
Ludovic Puig,
Ignasi Ribas,
Ignas Snellen,
Bruce Swinyard. France Allard,
Joanna Barstow,
James Cho,
Athena Coustenis,
Charles Cockell,
Alexandre Correia,
Leen Decin,
Remco de Kok,
Pieter Deroo,
Therese Encrenaz,
Francois Forget,
Alistair Glasse,
Caitlin Griffith
, et al. (326 additional authors not shown)
Abstract:
The discovery of almost 2000 exoplanets has revealed an unexpectedly diverse planet population. Observations to date have shown that our Solar System is certainly not representative of the general population of planets in our Milky Way. The key science questions that urgently need addressing are therefore: What are exoplanets made of? Why are planets as they are? What causes the exceptional divers…
▽ More
The discovery of almost 2000 exoplanets has revealed an unexpectedly diverse planet population. Observations to date have shown that our Solar System is certainly not representative of the general population of planets in our Milky Way. The key science questions that urgently need addressing are therefore: What are exoplanets made of? Why are planets as they are? What causes the exceptional diversity observed as compared to the Solar System?
EChO (Exoplanet Characterisation Observatory) has been designed as a dedicated survey mission for transit and eclipse spectroscopy capable of observing a large and diverse planet sample within its four-year mission lifetime. EChO can target the atmospheres of super-Earths, Neptune-like, and Jupiter-like planets, in the very hot to temperate zones (planet temperatures of 300K-3000K) of F to M-type host stars. Over the next ten years, several new ground- and space-based transit surveys will come on-line (e.g. NGTS, CHEOPS, TESS, PLATO), which will specifically focus on finding bright, nearby systems. The current rapid rate of discovery would allow the target list to be further optimised in the years prior to EChO's launch and enable the atmospheric characterisation of hundreds of planets. Placing the satellite at L2 provides a cold and stable thermal environment, as well as a large field of regard to allow efficient time-critical observation of targets randomly distributed over the sky. A 1m class telescope is sufficiently large to achieve the necessary spectro-photometric precision. The spectral coverage (0.5-11 micron, goal 16 micron) and SNR to be achieved by EChO, thanks to its high stability and dedicated design, would enable a very accurate measurement of the atmospheric composition and structure of hundreds of exoplanets.
△ Less
Submitted 19 February, 2015;
originally announced February 2015.
-
The COSPIX mission: focusing on the energetic and obscured Universe
Authors:
P. Ferrando,
A. Goldwurm,
P. Laurent,
O. Limousin,
V. Beckmann,
M. Arnaud,
X. Barcons,
D. Bomans,
I. Caballero,
F. Carrera,
S. Chaty,
J. Chenevez,
R. Chipaux,
F. Christensen,
A. Claret,
S. Corbel,
J. Croston,
E. Daddi,
M. De Becker,
A. Decourchelle,
D. Elbaz,
M. Falanga,
C. Ferrari,
C. Feruglio,
D. Götz
, et al. (35 additional authors not shown)
Abstract:
Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of it…
▽ More
Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of its call for selection of the M3 mission. In addition, COSPIX, will also provide key measurements on the non thermal Universe, particularly in relation to the question of the acceleration of particles, as well as on many other fundamental questions as for example the energetic particle content of clusters of galaxies. COSPIX is proposed as an observatory operating from 0.3 to more than 100 keV. The payload features a single long focal length focusing telescope offering an effective area close to ten times larger than any scheduled focusing mission at 30 keV, an angular resolution better than 20 arcseconds in hard X-rays, and polarimetric capabilities within the same focal plane instrumentation. In this paper, we describe the science objectives of the mission, its baseline design, and its performances, as proposed to ESA.
△ Less
Submitted 8 April, 2011;
originally announced April 2011.
-
The Herschel-SPIRE instrument and its in-flight performance
Authors:
M. J. Griffin,
A. Abergel,
A. Abreu,
P. A. R. Ade,
P. André,
J. -L. Augueres,
T. Babbedge,
Y. Bae,
T. Baillie,
J. -P. Baluteau,
M. J. Barlow,
G. Bendo,
D. Benielli,
J. J. Bock,
P. Bonhomme,
D. Brisbin,
C. Brockley-Blatt,
M. Caldwell,
C. Cara,
N. Castro-Rodriguez,
R. Cerulli,
P. Chanial,
S. Chen,
E. Clark,
D. L. Clements
, et al. (154 additional authors not shown)
Abstract:
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-c…
▽ More
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-map**, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
-
SIMBOL-X, a formation flying-mission for hard X-ray astrophysics
Authors:
P. Ferrando,
A. Goldwurm,
P. Laurent,
O. Limousin,
J. Martignac,
F. Pinsard,
Y. Rio,
J. P. Roques,
O. Citterio,
G. Pareschi,
G. Tagliaferri,
F. Fiore,
G. Malaguti,
U. Briel,
G. Hasinger,
L. Strueder
Abstract:
SIMBOL-X is a hard X-ray mission, operating in the ~ 0.5-70 keV range, which is proposed by a consortium of European laboratories in response to the 2004 call for ideas of CNES for a scientific mission to be flown on a formation flying demonstrator. Relying on two spacecrafts in a formation flying configuration, SIMBOL-X uses for the first time a ~ 30 m focal length X-ray mirror to focus X-rays…
▽ More
SIMBOL-X is a hard X-ray mission, operating in the ~ 0.5-70 keV range, which is proposed by a consortium of European laboratories in response to the 2004 call for ideas of CNES for a scientific mission to be flown on a formation flying demonstrator. Relying on two spacecrafts in a formation flying configuration, SIMBOL-X uses for the first time a ~ 30 m focal length X-ray mirror to focus X-rays with energy above 10 keV, resulting in a two orders of magnitude improvement in angular resolution and sensitivity in the hard X-ray range with respect to non focusing techniques. The SIMBOL-X revolutionary instrumental capabilities will allow to elucidate outstanding questions in high energy astrophysics, related in particular to the physics of accretion onto compact objects, to the acceleration of particles to the highest energies, and to the nature of the Cosmic X-Ray background. The mission, which has gone through a thorough assessment study performed by CNES, is expected to start a competitive phase A in autumn 2005, leading to a flight decision at the end of 2006, for a launch in 2012. The mission science objectives, the current status of the instrumentation and mission design, as well as potential trade-offs are presented in this paper.
△ Less
Submitted 31 August, 2005;
originally announced August 2005.