-
Inverse-designed flat lens for imaging in the visible & near-infrared with diameter > 3mm and NA=0.3
Authors:
Monjurul Meem,
Sourangsu Banerji,
Apratim Majumder,
Christian Pies,
Timo Oberbiermann,
Berardi Sensale-Rodriguez,
Rajesh Menon
Abstract:
It is generally thought that correcting chromatic aberrations in imaging requires multiple surfaces. Here, we show that by allowing the phase in the image plane of a flat lens to be a free parameter, it is possible to correct chromatic aberrations over a large continuous bandwidth with a single diffractive surface. We experimentally demonstrate imaging using a single flat lens of diameter > 3mm, f…
▽ More
It is generally thought that correcting chromatic aberrations in imaging requires multiple surfaces. Here, we show that by allowing the phase in the image plane of a flat lens to be a free parameter, it is possible to correct chromatic aberrations over a large continuous bandwidth with a single diffractive surface. We experimentally demonstrate imaging using a single flat lens of diameter > 3mm, focal length = 5mm (NA = 0.3, f/1.59) that is achromatic from 0.45um to 1um. This combination of size, NA and operating bandwidth has not been demonstrated in a flat lens before. We experimentally characterized the point-spread functions, off-axis aberrations and the broadband imaging performance. In contrast to conventional lens design, we utilize inverse design, where phase in the focal plane is treated as a free parameter. This approach attains a phase-only (lossless) pupil function, which can be implemented as a multi-level diffractive flat lens that achieves achromatic focusing and imaging.
△ Less
Submitted 25 April, 2020;
originally announced April 2020.
-
Large-area, high-NA Multi-level Diffractive Lens via inverse design
Authors:
Monjurul Meem,
Sourangsu Banerji,
Christian Pies,
Timo Oberbiermann,
Beradi Sensale-Rodriguez,
Rajesh Menon
Abstract:
Flat lenses enable thinner, lighter, and simpler imaging systems. However, large-area and high-NA flat lenses have been elusive due to computational and fabrication challenges. Here, we applied inverse design to create a multi-level diffractive lens (MDL) with thickness <1.35μm, diameter of 4.13mm, NA=0.9 at wavelength of 850nm. Since the MDL is created in polymer, it can be cost-effectively repli…
▽ More
Flat lenses enable thinner, lighter, and simpler imaging systems. However, large-area and high-NA flat lenses have been elusive due to computational and fabrication challenges. Here, we applied inverse design to create a multi-level diffractive lens (MDL) with thickness <1.35μm, diameter of 4.13mm, NA=0.9 at wavelength of 850nm. Since the MDL is created in polymer, it can be cost-effectively replicated via imprint lithography.
△ Less
Submitted 17 January, 2020;
originally announced January 2020.
-
Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments
Authors:
O. Novotný,
S. Allgeier,
C. Enss,
A. Fleischmann,
L. Gamer,
D. Hengstler,
S. Kempf,
C. Krantz,
A. Pabinger,
C. Pies,
D. W. Savin,
D. Schwalm,
A. Wolf
Abstract:
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecula…
▽ More
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecular projectiles of up to mass 56 u. We have demonstrated the capability of identifying neutral fragmentation products of these molecules by calorimetric mass spectrometry. We have modeled the MMC energy-response function for molecular projectiles and conclude that backscattering is the dominant source of the energy spread at the impact energies investigated. We have successfully demonstrated the use of a detector absorber coating to suppress such spreads. We briefly outline the use of MMC detectors in experiments on gas-phase collision reactions with neutral products. Our findings are of general interest for mass spectrometric techniques, particularly for those desiring to make neutral-particle mass measurements.
△ Less
Submitted 12 June, 2015; v1 submitted 27 May, 2015;
originally announced May 2015.
-
Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted $^{163}$Ho ions
Authors:
L. Gastaldo,
P. Ranitzsch,
F. von Seggern,
J. -P. Porst,
S. Schäfer,
C. Pies,
S. Kempf,
T. Wolf,
A. Fleischmann,
C. Enss,
A. Herlert,
K. Johnston
Abstract:
For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ion…
▽ More
For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ions implanted in the absorber. The implantation of $^{163}$Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. In addition an optimized detector design for future $^{163}$Ho experiments is presented.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.