Showing 1–2 of 2 results for author: Piccon, R
-
Rotation related systematic effects in a cold atom interferometer onboard a Nadir pointing satellite
Authors:
Quentin Beaufils,
Julien Lefebve,
Joel Gomes Baptista,
Raphaël Piccon,
Valentin Cambier,
Leonid A. Sidorenkov,
Christine Fallet,
Thomas Lévèque,
Franck Pereira Dos Santos
Abstract:
We study the effects of rotations on a cold atom accelerometer onboard a Nadir pointing satellite. A simulation of the satellite attitude combined with a calculation of the phase of the cold atom interferometer allow us to evaluate the noise and bias induced by rotations. In particular, we evaluate the effects associated to the active compensation of the rotation due to Nadir pointing. This study…
▽ More
We study the effects of rotations on a cold atom accelerometer onboard a Nadir pointing satellite. A simulation of the satellite attitude combined with a calculation of the phase of the cold atom interferometer allow us to evaluate the noise and bias induced by rotations. In particular, we evaluate the effects associated to the active compensation of the rotation due to Nadir pointing. This study was realized in the context of the preliminary study phase of the CARIOQA Quantum Pathfinder Mission.
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
Separating the output ports of a Bragg interferometer via velocity selective transport
Authors:
Raphaël Piccon,
Sumit Sarkar,
Sébastien Merlet,
Franck Pereira dos Santos
Abstract:
We report on the study of a detection scheme based on a Bloch separator in two-photon Bragg interferometers. We increase the spatial separation between the two output ports of the interferometer by selectively imparting 30 Bloch oscillations to one of them before their detection via time of flight. This method allows increasing the duration of the interferometer by reducing the time for discrimina…
▽ More
We report on the study of a detection scheme based on a Bloch separator in two-photon Bragg interferometers. We increase the spatial separation between the two output ports of the interferometer by selectively imparting 30 Bloch oscillations to one of them before their detection via time of flight. This method allows increasing the duration of the interferometer by reducing the time for discriminating the ports of the interferometer at detection. We study in detail the impact of this separator on the performance of a dual gravity sensor, and in particular on its measurement sensitivities to gravity acceleration and gravity gradients.
△ Less
Submitted 7 March, 2022;
originally announced March 2022.