Skip to main content

Showing 1–16 of 16 results for author: Philipp, T

.
  1. arXiv:2310.07017  [pdf, other

    cond-mat.mtrl-sci stat.AP

    Stochastic 3D modeling of nanostructured NVP/C active material particles for sodium-ion batteries

    Authors: Matthias Neumann, Tom Philipp, Marcel Häringer, Gregor Neusser, Joachim R. Binder, Christine Kranz

    Abstract: A data-driven modeling approach is presented to quantify the influence of morphology on effective properties in nanostructured sodium vanadium phosphate $\mathrm{Na}_3\mathrm{V}_2(\mathrm{PO}_4)_3$/ carbon composites (NVP/C), which are used as cathode material in sodium-ion batteries. This approach is based on the combination of advanced imaging techniques, experimental nanostructure characterizat… ▽ More

    Submitted 10 October, 2023; originally announced October 2023.

    MSC Class: 62H11; 82D30; 94A04

  2. arXiv:2308.15892  [pdf, other

    cs.AI cs.DB cs.LO

    A Logic Programming Approach to Global Logistics in a Co-Design Environment

    Authors: Emmanuelle Dietz, Tobias Philipp, Gerrit Schramm, Andreas Zindel

    Abstract: In a co-design environment changes need to be integrated quickly and in an automated manner. This paper considers the challenge of creating and optimizing a global logistics system for the construction of a passenger aircraft within a co-design approach with respect to key performance indicators (like cost, time or resilience). The product in question is an aircraft, comprised of multiple componen… ▽ More

    Submitted 30 August, 2023; originally announced August 2023.

    Comments: In Proceedings ICLP 2023, arXiv:2308.14898

    Journal ref: EPTCS 385, 2023, pp. 227-240

  3. arXiv:2112.00146  [pdf, other

    physics.ins-det

    Characterization of 128x128 MM-PAD-2.1 ASIC: A Fast Framing Hard X-Ray Detector with High Dynamic Range

    Authors: D. Gadkari, K. S. Shanks, H. Hu, H. T. Philipp, M. W. Tate, J. Thom-Levy, S. M. Gruner

    Abstract: We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10$^{7}$ x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while im… ▽ More

    Submitted 16 February, 2022; v1 submitted 30 November, 2021; originally announced December 2021.

    Comments: 16 pages, 7 figures Typos removed. Language changes, minor figure changes (figure 1 and figure 4) and additional information added to make the information presented streamlined and clear. Results unchanged

  4. Very-High Dynamic Range, 10,000 frames/second Pixel Array Detector for Electron Microscopy

    Authors: Hugh T. Philipp, Mark W. Tate, Katherine S. Shanks, Luigi Mele, Maurice Peemen, Pleun Dona, Reinout Hartong, Gerard van Veen, Yu-Tsun Shao, Zhen Chen, Julia Thom-Levy, David A. Muller, Sol M. Gruner

    Abstract: Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the map** of electric, magnetic and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electr… ▽ More

    Submitted 10 November, 2021; originally announced November 2021.

  5. Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

    Authors: D. Gadkari, K. S. Shanks, H. T. Philipp, M. W. Tate, J. Thom-Levy, S. M. Gruner

    Abstract: Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD-2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2$\times$2 pixel configuration using a n… ▽ More

    Submitted 5 November, 2020; v1 submitted 26 May, 2020; originally announced May 2020.

    Comments: Revised manuscript reflecting minor proofreading changes

  6. High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

    Authors: Hugh T. Philipp, Mark W. Tate, Katherine S. Shanks, Prafull Purohit, Sol M. Gruner

    Abstract: A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 micron thick cadmium telluride (CdTe) sensor. The full imager is a 2 x 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficie… ▽ More

    Submitted 9 June, 2020; v1 submitted 7 April, 2020; originally announced April 2020.

  7. arXiv:1907.10389  [pdf, ps, other

    cs.LO cs.AI

    Inconsistency Proofs for ASP: The ASP-DRUPE Format

    Authors: Mario Alviano, Carmine Dodaro, Johannes K. Fichte, Markus Hecher, Tobias Philipp, Jakob Rath

    Abstract: Answer Set Programming (ASP) solvers are highly-tuned and complex procedures that implicitly solve the consistency problem, i.e., deciding whether a logic program admits an answer set. Verifying whether a claimed answer set is formally a correct answer set of the program can be decided in polynomial time for (normal) programs. However, it is far from immediate to verify whether a program that is c… ▽ More

    Submitted 24 July, 2019; originally announced July 2019.

    Comments: Paper presented at the 35th International Conference on Logic Programming (ICLP 2019), Las Cruces, New Mexico, USA, 20-25 September 2019, 16 pages

  8. arXiv:1811.11623  [pdf, other

    cs.AI cs.CV

    Large Scale Audio-Visual Video Analytics Platform for Forensic Investigations of Terroristic Attacks

    Authors: Alexander Schindler, Martin Boyer, Andrew Lindley, David Schreiber, Thomas Philipp

    Abstract: The forensic investigation of a terrorist attack poses a huge challenge to the investigative authorities, as several thousand hours of video footage need to be spotted. To assist law enforcement agencies (LEA) in identifying suspects and securing evidences, we present a platform which fuses information of surveillance cameras and video uploads from eyewitnesses. The platform integrates analytical… ▽ More

    Submitted 28 November, 2018; originally announced November 2018.

    Journal ref: 25th International Conference on MultiMedia Modeling (MMM2019)

  9. arXiv:1811.05883  [pdf, other

    physics.app-ph physics.data-an physics.ins-det physics.optics

    Experimental 3D Coherent Diffractive Imaging from photon-sparse random projections

    Authors: K. Giewekemeyer, A. Aquila, N. D. Loh, Y. Chushkin, K. S. Shanks, J. Weiss, M. W. Tate, H. T. Philipp, S. Stern, P. Vagovic, M. Mehrjoo, C. Teo, M. Barthelmess, F. Zontone, C. Chang, R. C. Tiberio, A. Sakdinawat, G. J. Williams, S. M. Gruner, A. P. Mancuso

    Abstract: The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules. Extremely-bright, ultrashort-pulse X-ray sources---X-ray Free Electron Lasers (XFELs)---provide X-rays that can be used to probe ensembles of nearly identical nano-scale… ▽ More

    Submitted 14 November, 2018; originally announced November 2018.

    Comments: 17 pages, 12 figures

  10. Characterization of Chromium Compensated GaAs as an x-ray Sensor Material for Charge-Integrating Pixel Array Detectors

    Authors: Julian Becker, Mark W. Tate, Katherine S. Shanks, Hugh T. Philipp, Joel T. Weiss, Prafull Purohit, Darol Chamberlain, Sol M. Gruner

    Abstract: We studied the properties of chromium compensated GaAs when coupled to charge integrating ASICs as a function of detector temperature, applied bias and x-ray tube energy. The material is a photoresistor and can be biased to collect either electrons or holes by the pixel circuitry. Both are studied here. Previous studies have shown substantial hole trap**. This trap** and other sensor propertie… ▽ More

    Submitted 21 November, 2017; v1 submitted 7 July, 2017; originally announced July 2017.

    Comments: revised version after 2nd peer review

  11. Sub-Microsecond X-Ray Imaging Using Hole-Collecting Schottky type CdTe with Charge-Integrating Pixel Array Detectors

    Authors: Julian Becker, Mark W. Tate, Katherine S. Shanks, Hugh T. Philipp, Joel T. Weiss, Prafull Purohit, Darol Chamberlain, Sol M. Gruner

    Abstract: CdTe is increasingly being used as the x-ray sensing material in imaging pixel array detectors for x-rays, generally above 20 keV, where silicon sensors become unacceptably transparent. Unfortunately CdTe suffers from polarization, which can alter the response of the material over time and with accumulated dose. Most prior studies used long integration times or CdTe that was not of the hole-collec… ▽ More

    Submitted 15 May, 2017; v1 submitted 6 March, 2017; originally announced March 2017.

    Comments: revised version after peer-review

  12. High Dynamic Range X-ray Detector Pixel Architectures Utilizing Charge Removal

    Authors: Joel T. Weiss, Katherine S. Shanks, Hugh T. Philipp, Julian Becker, Darol Chamberlain, Prafull Purohit, Mark W. Tate, Sol M. Gruner

    Abstract: Several charge integrating CMOS pixel front-ends utilizing charge removal techniques have been fabricated to extend dynamic range for x-ray diffraction applications at synchrotron sources and x-ray free electron lasers (XFELs). The pixels described herein build on the Mixed Mode Pixel Array Detector (MM-PAD) framework, developed previously by our group to perform high dynamic range imaging. These… ▽ More

    Submitted 28 October, 2016; originally announced October 2016.

    Comments: 6 pages, 7 figures

  13. Characterization of CdTe Sensors with Schottky Contacts Coupled to Charge-Integrating Pixel Array Detectors for X-Ray Science

    Authors: Julian Becker, Mark W. Tate, Katherine S. Shanks, Hugh T. Philipp, Joel T. Weiss, Prafull Purohit, Darol Chamberlain, Jacob P. C. Ruff, Sol M. Gruner

    Abstract: Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we present characterizations of CdTe sensors hybridized with two different charge-integrating readout chips, the Keck PAD and the Mixed… ▽ More

    Submitted 28 November, 2016; v1 submitted 12 September, 2016; originally announced September 2016.

    Comments: Revised version after 2nd peer-review

  14. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy

    Authors: Mark W. Tate, Prafull Purohit, Darol Chamberlain, Kayla X. Nguyen, Robert M. Hovden, Celesta S. Chang, Pratiti Deb, Emrah Turgut, John T. Heron, Darrell G. Schlom, Daniel C. Ralph, Gregory D. Fuchs, Katherine S. Shanks, Hugh T. Philipp, David A. Muller, Sol M. Gruner

    Abstract: We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel detector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel ci… ▽ More

    Submitted 11 November, 2015; originally announced November 2015.

    Comments: 39 pages total, 11 Figures in Microscopy and Microanalysis, 2015

  15. arXiv:1311.1776  [pdf, other

    physics.data-an physics.bio-ph physics.ins-det

    Real-Space x-ray tomographic reconstruction of randomly oriented objects with sparse data frames

    Authors: Kartik Ayyer, Hugh T. Philipp, Mark W. Tate, Veit Elser, Sol M. Gruner

    Abstract: Schemes for X-ray imaging single protein molecules using new x-ray sources, like x-ray free electron lasers (XFELs), require processing many frames of data that are obtained by taking temporally short snapshots of identical molecules, each with a random and unknown orientation. Due to the small size of the molecules and short exposure times, average signal levels of much less than 1 photon/pixel/f… ▽ More

    Submitted 7 November, 2013; originally announced November 2013.

    Comments: 10 pages, 5 figures

  16. arXiv:1203.3353  [pdf, other

    physics.ins-det physics.bio-ph physics.data-an

    Solving Structure with Sparse, Randomly-Oriented X-ray Data

    Authors: Hugh T. Philipp, Kartik Ayyer, Mark W. Tate, Veit Elser, Sol M. Gruner

    Abstract: Single-particle imaging experiments of biomolecules at x-ray free-electron lasers (XFELs) require processing of hundreds of thousands (or more) of images that contain very few x-rays. Each low-flux image of the diffraction pattern is produced by a single, randomly oriented particle, such as a protein. We demonstrate the feasibility of collecting data at these extremes, averaging only 2.5 photons p… ▽ More

    Submitted 15 March, 2012; originally announced March 2012.