A catalogue of dual-field interferometric binary calibrators
Authors:
M. Nowak,
S. Lacour,
R. Abuter,
A. Amorim,
R. Asensio-Torres,
W. O. Balmer,
M. Benisty,
J. -P. Berger,
H. Beust,
S. Blunt,
A. Boccaletti,
M. Bonnefoy,
H. Bonnet,
M. S. Bordoni,
G. Bourdarot,
W. Brandner,
F. Cantalloube,
B. Charnay,
G. Chauvin,
A. Chavez,
E. Choquet,
V. Christiaens,
Y. Clénet,
V. Coudé du Foresto,
A. Cridland
, et al. (75 additional authors not shown)
Abstract:
Dual-field interferometric observations with VLTI/GRAVITY sometimes require the use of a "binary calibrator", a binary star whose individual components remain unresolved by the interferometer, with a separation between 400 and 2000 mas for observations with the Units Telescopes (UTs), or 1200 to 3000 mas for the Auxiliary Telescopes (ATs). The separation vector also needs to be predictable to with…
▽ More
Dual-field interferometric observations with VLTI/GRAVITY sometimes require the use of a "binary calibrator", a binary star whose individual components remain unresolved by the interferometer, with a separation between 400 and 2000 mas for observations with the Units Telescopes (UTs), or 1200 to 3000 mas for the Auxiliary Telescopes (ATs). The separation vector also needs to be predictable to within 10 mas for proper pointing of the instrument. Up until now, no list of properly vetted calibrators was available for dual-field observations with VLTI/GRAVITY on the UTs. Our objective is to compile such a list, and make it available to the community. We identify a list of candidates from the Washington Double Star (WDS) catalogue, all with appropriate separations and brightness, scattered over the Southern sky. We observe them as part of a dedicated calibration programme, and determine whether these objects are true binaries (excluding higher multiplicities resolved interferometrically but unseen by imaging), and extract measurements of the separation vectors. We combine these new measurements with those available in the WDS to determine updated orbital parameters for all our vetted calibrators. We compile a list of 13 vetted binary calibrators for observations with VLTI/GRAVITY on the UTs, and provide orbital estimates and astrometric predictions for each of them. We show that our list guarantees that there are always at least two binary calibrators at airmass < 2 in the sky over the Paranal observatory, at any point in time. Any Principal Investigator wishing to use the dual-field mode of VLTI/GRAVITY with the UTs can now refer to this list to select an appropriate calibrator. We encourage the use of "whereistheplanet" to predict the astrometry of these calibrators, which seamlessly integrates with "p2Gravity" for VLTI/GRAVITY dual-field observing material preparation.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
Single-mode waveguides for GRAVITY II. Single-mode fibers and Fiber Control Unit
Authors:
G. Perrin,
L. Jocou,
K. Perraut,
J. Ph. Berger,
R. Dembet,
P. Fédou,
S. Lacour,
F. Chapron,
C. Collin,
S. Poulain,
V. Cardin,
F. Joulain,
F. Eisenhauer,
X. Haubois,
S. Gillessen,
M. Haug,
F. Hausmann,
P. Kervella,
P. Léna,
M. Lippa,
O. Pfuh,
S. Rabien,
A. Amorim,
W. Brandner,
C. Straubmeier
Abstract:
The 2nd generation VLTI instrument GRAVITY is a two-field infrared interferometer operating in the K band between 1.97 and 2.43 $μ$m with either the four 8 m or the four 1.8 m telescopes of the Very Large Telescope (VLT). Beams collected by the telescopes are corrected with adaptive optics systems and the fringes are stabilized with a fringe-tracking system. A metrology system allows the measureme…
▽ More
The 2nd generation VLTI instrument GRAVITY is a two-field infrared interferometer operating in the K band between 1.97 and 2.43 $μ$m with either the four 8 m or the four 1.8 m telescopes of the Very Large Telescope (VLT). Beams collected by the telescopes are corrected with adaptive optics systems and the fringes are stabilized with a fringe-tracking system. A metrology system allows the measurement of internal path lengths in order to achieve high-accuracy astrometry. High sensitivity and high interferometric accuracy are achieved thanks to (i) correction of the turbulent phase, (ii) the use of low-noise detectors, and (iii) the optimization of photometric and coherence throughput. Beam combination and most of the beam transport are performed with single-mode waveguides in vacuum and at low temperature. In this paper, we present the functions and performance achieved with weakly birefringent standard single-mode fiber systems in GRAVITY. Fibered differential delay lines (FDDLs) are used to dynamically compensate for up to 6 mm of delay between the science and reference targets. Fibered polarization rotators allow us to align polarizations in the instrument and make the single-mode beam combiner close to polarization neutral. The single-mode fiber system exhibits very low birefringence (less than 23°), very low attenuation (3.6-7 dB/km across the K band), and optimized differential dispersion (less than 2.04 $μ$rad cm2 at zero extension of the FDDLs). As a consequence, the typical fringe contrast losses due to the single-mode fibers are 6% to 10% in the lowest-resolution mode and 5% in the medium- and high-resolution modes of the instrument for a photometric throughput of the fiber chain of the order of 90%. There is no equivalent of this fiber system to route and modally filter beams with delay and polarization control in any other K-band beamcombiner.
△ Less
Submitted 19 January, 2024;
originally announced January 2024.