-
Radioisotopes production using lasers: from basic science to applications
Authors:
M. R. D. Rodrigues,
A. Bonasera,
M. Scisciò,
J. A. Pérez-Hernández,
M. Ehret,
F. Filippi,
P. L. Andreoli,
M. Huault,
H. Larreur,
D. Singappuli,
D. Molloy,
D. Raffestin,
M. Alonzo,
G. G. Rapisarda,
D. Lattuada,
G. L. Guardo,
C. Verona,
Fe. Consoli,
G. Petringa,
A. McNamee,
M. La Cognata,
S. Palmerini,
T. Carriere,
M. Cipriani,
G. Di Giorgio
, et al. (15 additional authors not shown)
Abstract:
Laser technologies improved after the understanding of the Chirped Pulse Amplification (CPA) which allows energetic laser beams to be compressed to tens of femtosecond (fs) pulse durations and focused to few $μ$m. Protons of tens of MeV can be accelerated using for instance the Target Normal Sheath Acceleration (TNSA) method and focused on secondary targets. In such conditions, nuclear reactions c…
▽ More
Laser technologies improved after the understanding of the Chirped Pulse Amplification (CPA) which allows energetic laser beams to be compressed to tens of femtosecond (fs) pulse durations and focused to few $μ$m. Protons of tens of MeV can be accelerated using for instance the Target Normal Sheath Acceleration (TNSA) method and focused on secondary targets. In such conditions, nuclear reactions can occur and radioisotopes relevant for medical purposes be produced. High repetition lasers can be used to produce enough isotopes for medical applications. This route is competitive to conventional methods mostly based on accelerators. In this paper we study the production of $^{67}$Cu, $^{63}$Zn, $^{18}$F and $^{11}$C currently used in positron emission tomography (PET) and other applications. At the same time, we study the reaction $^{10}$B(p,$α$)$^{7}$Be and $^{70}$Zn(p,4n)$^{67}$Ga to put further constraints to the proton distributions at different angles and to the reaction $^{11}$B(p,$α$)$^{8}$Be relevant for energy production. The experiment was performed at the 1 petawatt (PW) laser facility at Vega III located in Salamanca-Spain. Angular distributions of radioisotopes in the forward (with respect to the laser direction) and backward directions were measured using a High Purity Germanium Detector (HPGE). Our results are reasonably reproduced by the numerical estimates following the approach of Kimura et al. (NIMA637(2011)167)
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Characterization of hydrogenated amorphous silicon sensors on polyimide flexible substrate
Authors:
M. Menichelli,
L. Antognini,
S. Aziz,
A. Bashiri,
M. Bizzarri,
L. Calcagnile,
M. Caprai,
D. Caputo,
A. P. Caricato,
R. Catalano,
D. Chilà,
G. A. P. Cirrone,
T. Croci,
G. Cuttone,
G. De Cesare,
S. Dunand,
M. Fabi,
L. Frontini,
C. Grimani,
M. Ionica,
K. Kanxheri,
M. Large,
V. Liberali,
N. Lovecchio,
M. Martino
, et al. (28 additional authors not shown)
Abstract:
Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H sensors can be successfully utilized in dosimetry, beam monitoring for particle physics (x-ray, electron, gamma-ray and proton detection) and radiothe…
▽ More
Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H sensors can be successfully utilized in dosimetry, beam monitoring for particle physics (x-ray, electron, gamma-ray and proton detection) and radiotherapy, radiation flux measurement for space applications (study of solar energetic particles and stellar events) and neutron flux measurements. In this paper we have studied the dosimetric x-ray response of n-i-p diodes deposited on Polyimide. We measured the linearity of the photocurrent response to x-rays versus dose-rate from which we have extracted the dosimetric x-ray sensitivity at various bias voltages. In particular low bias voltage operation has been studied to assess the high energy efficiency of these kind of sensor. A measurement of stability of x-ray response versus time has been shown. The effect of detectors annealing has been studied. Operation under bending at various bending radii is also shown.
△ Less
Submitted 30 September, 2023;
originally announced October 2023.
-
A Hydrogenated amorphous silicon detector for Space Weather Applications
Authors:
Catia Grimani,
Michele Fabi,
Federico Sabbatini,
Mattia Villani,
Lucio Calcagnile,
Anna Paola Caricato,
Roberto Catalano,
Giuseppe Antonio Pablo Cirrone,
Tommaso Croci,
Giacomo Cuttone,
Sylvain Dunand,
Luca Frontini,
Maria Ionica,
Keida Kanxheri,
Matthew Large,
Valentino Liberali,
Maurizio Martino,
Giuseppe Maruccio,
Giovanni Mazza,
Mauro Menichelli,
Anna Grazia Monteduro,
Arianna Morozzi,
Francesco Moscatelli,
Stefania Pallotta,
Daniele Passeri
, et al. (13 additional authors not shown)
Abstract:
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events up to hundreds of MeV. The a-Si:H presents an excellent radiation hardness and finds application in harsh radiation environments for medical purposes, for particle beam characterization and in space weather science and…
▽ More
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events up to hundreds of MeV. The a-Si:H presents an excellent radiation hardness and finds application in harsh radiation environments for medical purposes, for particle beam characterization and in space weather science and applications. The critical flux detection threshold for solar X rays, soft gamma rays, electrons and protons is discussed in detail.
△ Less
Submitted 1 September, 2023; v1 submitted 1 February, 2023;
originally announced February 2023.
-
Development of thin hydrogenated amorphous silicon detectors on a flexible substrate
Authors:
M. Menichelli,
M. Bizzarri,
L. Calcagnile,
M. Caprai,
A. P. Caricato,
R. Catalano,
G. A. P. Cirrone,
T. Croci,
G. Cuttone,
S. Dunand,
M. Fabi,
L. Frontini,
B. Gianfelici,
C. Grimani,
M. Ionica,
K. Kanxheri,
M. Large,
V. Liberali,
M. Martino,
G. Maruccio,
G. Mazza,
A. G. Monteduro,
A. Morozzi,
F. Moscatelli,
S. Pallotta
, et al. (18 additional authors not shown)
Abstract:
The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (mostly Polyimide) for beam monitoring, neutron detection and space applications. Since a-Si:H is a material with superior radiation hardness, the benefit for the above-mentioned applications can be appreciated mostly in radi…
▽ More
The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (mostly Polyimide) for beam monitoring, neutron detection and space applications. Since a-Si:H is a material with superior radiation hardness, the benefit for the above-mentioned applications can be appreciated mostly in radiation harsh environments. Furthermore, the possibility to deposit this material on flexible substrates like Polyimide (PI), polyethylene naphthalate (PEN) or polyethylene terephthalate (PET) facilitates the usage of these detectors in medical dosimetry, beam flux and beam profile measurements. Particularly interesting is its use when positioned directly on the flange of the vacuum-to-air separation interface in a beam line, as well as other applications where a thin self-standing radiation flux detector is envisaged. In this paper, the HASPIDE project will be described and some preliminary results on PI and glass substrates will be reported.
△ Less
Submitted 30 November, 2022;
originally announced November 2022.
-
Testing of planar hydrogenated amorphous silicon sensors with charge selective contacts for the construction of 3D- detectors
Authors:
M. Menichelli,
M. Bizzarri,
M. Boscardin,
M. Caprai,
A. P. Caricato,
G. A. P. Cirrone,
M. Crivellari,
I. Cupparo,
G. Cuttone,
S. Dunand,
L. Fanò,
O. Hammad,
M. Ionica,
K. Kanxheri,
M. Large,
G. Maruccio,
A. G. Monteduro,
A. Morozzi,
F. Moscatelli,
A. Papi,
D. Passeri,
M. Petasecca,
G. Petringa,
G. Quarta,
S. Rizzato
, et al. (7 additional authors not shown)
Abstract:
Hydrogenated Amorphous Silicon (a-Si:H) is a material well known for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and dosimetry. Planar p-i-n diode detectors are fabricated entirely by means of intrinsic and doped PECVD of a mixture of Silane (SiH4) and molecular Hydrogen. In order to develop 3D detector geometries using a-Si:H, two op…
▽ More
Hydrogenated Amorphous Silicon (a-Si:H) is a material well known for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and dosimetry. Planar p-i-n diode detectors are fabricated entirely by means of intrinsic and doped PECVD of a mixture of Silane (SiH4) and molecular Hydrogen. In order to develop 3D detector geometries using a-Si:H, two options for the junction fabrication have been considered: ion implantation and charge selective contacts through atomic layer deposition. In order to test the functionality of the charge selective contact electrodes, planar detectors have been fabricated utilizing this technique. In this paper, we provide a general overview of the 3D fabrication project followed by the results of leakage current measurements and x-ray dosimetric tests performed on planar diodes containing charge selective contacts to investigate the feasibility of the charge selective contact methodology for integration with the proposed 3D detector architectures.
△ Less
Submitted 3 February, 2022; v1 submitted 30 September, 2021;
originally announced September 2021.
-
Feasibility Study and Perspectives of proton Dielectric Laser Accelerators (p-DLA): from nanosource to accelerator scheme
Authors:
G. Torrisi,
D. Mascali,
A. Bacci,
G. A. P. Cirrone,
G. Cosentino,
G. Della Valle,
N. Gambino,
G. S. Mauro,
G. Petringa,
G. Russo,
C. Schmitzer,
G. Sorbello,
R. A. Wilhelm
Abstract:
In this paper we discuss the possibility to generate and accelerate proton nanobeams in fully dielectric laser-driven accelerators (p-DLAs). High gradient on-chip optical-power dielectric laser accelerators (DLAs) could represent one of the most promising way towards future miniaturized particle accelerator. A primary challenge for DLAs are small beam apertures having a size of the order of the dr…
▽ More
In this paper we discuss the possibility to generate and accelerate proton nanobeams in fully dielectric laser-driven accelerators (p-DLAs). High gradient on-chip optical-power dielectric laser accelerators (DLAs) could represent one of the most promising way towards future miniaturized particle accelerator. A primary challenge for DLAs are small beam apertures having a size of the order of the driving laser wavelength where low charge high-repetition (or also CW) ultralow emittance nanobeams have to be transported. For electrons beams generation and acceleration, intense research activities are ongoing, and several demonstrations have been already obtained by using electrons nanotip (or flat photocathode) sources feeding dielectric microstructures. In this article we aim at the possibility to integrate a nanosource for the generation of a light ion or proton nano-beams suitable for the subsequent acceleration into sub-relativistic (low-beta) p-DLA stages. Such integration includes the idea to use a proton dielectric radiofrequency quadrupole (p-DRFQ) for bridging the gap between the accelerator front-end and the drift-tube and high-beta sections. The paper has been prepared as a white book including state-of-art technologies and new solutions that now put the ambitious frontier of a fully nanostructured proton accelerator into reach. Conceptual studies of p-DLAs here presented could enable table-top proton nano-beams for several applications: proton beam writing, nuclear reaction analysis at sub-micrometer scales, the construction of miniaturized Proton-Boron Nuclear Fusion based Reactors, biological analysis at the micrometer scale, ion beam analysis at the sub-cellular level, mini-beams ion therapy to spare the shallow tissues, proton irradiation of transistors, compact proton linac for neutron generation.
△ Less
Submitted 25 June, 2021;
originally announced June 2021.
-
A new energy spectrum reconstruction method for Time-Of-Flight diagnostics of high-energy laser-driven protons
Authors:
G. Milluzzo,
V. Scuderi,
A. Alejo,
A. G. Amico,
N. Booth,
M. Borghesi,
G. A. P. Cirrone,
G. Cuttone,
D. Doria,
J. Green,
S. Kar,
G. Korn,
G. Larosa,
R. Leanza,
D. Margarone,
P. Martin,
P. McKenna,
G. Petringa,
J. Pipek,
L. Romagnani,
F. Romano,
A. Russo,
F. Schillaci
Abstract:
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereb…
▽ More
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector's working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson Parabola Spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (RAL, UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.
△ Less
Submitted 4 December, 2018;
originally announced December 2018.
-
Discussing the discrepancy between analytical calculations and the observed biological effectiveness in proton boron capture therapy (pbct)
Authors:
G. A. P. Cirrone,
G. Petringa,
A. Attili,
D. Chiappara,
L. Manti,
V. Bravatà,
D. Margarone,
M. Mazzocco,
G. Cuttone
Abstract:
A work recently published experimentally demonstrates an increase in the radiobiological efficacy of clinical proton beams when a tumour is treated in the presence of a concentration of 11B. The paper, for the first time, demonstrates the potential role of the p+11B to 3α (for brevity, p-B) reaction in the biological enhancement of proton therapy effectiveness. The work reports robust experimental…
▽ More
A work recently published experimentally demonstrates an increase in the radiobiological efficacy of clinical proton beams when a tumour is treated in the presence of a concentration of 11B. The paper, for the first time, demonstrates the potential role of the p+11B to 3α (for brevity, p-B) reaction in the biological enhancement of proton therapy effectiveness. The work reports robust experimental data in terms of clonogenic cell survival and chromosomal aberrations and unambiguously shows the presence of an enhancement when cells were exposed to a clinical proton beam subject to treatment with sodium boroncaptate (BSH). Moreover, the greater occurrence of complex-type chromosomal exchanges points to the effect as due radiation of a LET (Linear Energy Transfer) greater than that of protons alone, possibly the alpha particles generated by the reaction. At the same time, we emphasized that analytical calculations, performed on the basis of the well-known total production cross section data, are not able to explain the effect in a macroscopic way, i.e. solely in terms of a trivial increase in the total dose released in the cells by the alpha-particles. In this paper, thanks to simulations and analytical calculations, we will discuss the theoretically expected alpha particle yield and the corresponding LET and RBE (Relative Biological Effectiveness) increase related to the 11B presence. We conclude that a mere calculation based on the classical concepts of integral Dose, and average LET and RBE cannot be used to justify the observed radiobiological phenomena. We, therefore, suggest that micro- and nano-dosimetric aspects must be taken into account.
△ Less
Submitted 14 October, 2018;
originally announced October 2018.
-
Response to the authors of 'On the (un)effectiveness of Proton Boron Capture in Proton Therapy'
Authors:
GAP Cirrone,
G Cuttone,
L Manti,
D. Margarone,
G Petringa,
L. Giuffrida,
A. Minopoli,
A. Picciotto,
G. Russo,
F. Cammarata,
P. Pisciotta,
F. M. Perozziello,
F. Romano,
V. Marchese,
G. Milluzzo,
V. Scuderi,
G. Cuttone,
G. Korn
Abstract:
This manuscript provides a response to a recent report by Mazzone et al. available online on arXiv that, in turn, tentatively aims at demonstrating the inefficacy of proton boron capture in hadrotherapy. We clarify that Mazzone et al. do not add any scientific or technical insights to the points extensively discussed in the original manuscript by Cirrone et al., and/or in the series of iterations…
▽ More
This manuscript provides a response to a recent report by Mazzone et al. available online on arXiv that, in turn, tentatively aims at demonstrating the inefficacy of proton boron capture in hadrotherapy. We clarify that Mazzone et al. do not add any scientific or technical insights to the points extensively discussed in the original manuscript by Cirrone et al., and/or in the series of iterations had with the Referee, which ultimately lead to the publication of our original and pioneering experimental work. Here we summarize some of the key points of the long scientific debate we had during the review process of paper by Cirrone et al., which are very similar to the considerations presented by Mazzone et al.. In conclusion, no quantitative explanation of our robust experimental achievements presented in Cirrone et al. is provided in Mazzone et al.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Geant4 simulation of the ELIMED transport and dosimetry beam line for high-energy laser-driven ion beam multidisciplinary applications
Authors:
G. Milluzzo,
J. Pipek,
A. G. Amico,
G. A. P. Cirrone,
G. Cuttone,
G. Korn,
G. Larosa,
R. Leanza,
D. Margarone,
G. Petringa,
A. Russo,
F. Schillaci,
V. Scuderi,
F. Romano
Abstract:
The ELIMED (MEDical and multidisciplinary application at ELI Beamlines) beam line is being developed at INFN-LNS with the aim of transporting and selecting in energy proton and ion beams accelerated by laser-matter interaction at ELI Beamlines in Prague. It will be a section of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ions Acceleration) beam line, dedicated to applications, includi…
▽ More
The ELIMED (MEDical and multidisciplinary application at ELI Beamlines) beam line is being developed at INFN-LNS with the aim of transporting and selecting in energy proton and ion beams accelerated by laser-matter interaction at ELI Beamlines in Prague. It will be a section of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ions Acceleration) beam line, dedicated to applications, including the medical one, of laser-accelerated ion beams [1,2]. A Monte Carlo model has been developed to support the design of the beam line in terms of particle transport efficiency, to optimize the transport parameters at the irradiation point in air and, furthermore, to predict beam parameters in order to deliver dose distributions of clinical relevance. The application has been developed using the Geant4 [3] Monte Carlo toolkit and has been designed in a modular way in order to easily switch on/off geometrical components according to different experimental setups and users requirements, as reported in [4], describing the early-stage code and simulations. The application has been delivered to ELI Beamlines and will be available for future ELIMAIA's users as ready-to-use tool useful during experiment preparation and analysis. The final version of the developed application will be described in detail in this contribution, together with the final results, in terms of energy spectra and transmission efficiency along the in-vacuum beam line, obtained by performing end-to-end simulations.
△ Less
Submitted 11 February, 2018;
originally announced February 2018.
-
Nuclear fusion enhances cancer cell killing efficacy in a protontherapy model
Authors:
GAP Cirrone,
L Manti,
D Margarone,
L Giuffrida,
A. Picciotto,
G. Cuttone,
G. Korn,
V. Marchese,
G. Milluzzo,
G. Petringa,
F. Perozziello,
F. Romano,
V. Scuderi
Abstract:
Protontherapy is hadrontherapy fastest-growing modality and a pillar in the battle against cancer. Hadrontherapy superiority lies in its inverted depth-dose profile, hence tumour-confined irradiation. Protons, however, lack distinct radiobiological advantages over photons or electrons. Higher LET (Linear Energy Transfer) $^{12}$C ions can overcome cancer radioresistance: DNA lesion complexity incr…
▽ More
Protontherapy is hadrontherapy fastest-growing modality and a pillar in the battle against cancer. Hadrontherapy superiority lies in its inverted depth-dose profile, hence tumour-confined irradiation. Protons, however, lack distinct radiobiological advantages over photons or electrons. Higher LET (Linear Energy Transfer) $^{12}$C ions can overcome cancer radioresistance: DNA lesion complexity increases with LET, resulting in efficient cell killing, i.e. higher Relative Biological Effectiveness (RBE). However, economic and radiobiological issues hamper $^{12}$C-ion clinical amenability. Thus, enhancing proton RBE is desirable. To this end, we exploited the p + $^{11}$B $\rightarrow$3$α$ reaction to generate high-LET alpha particles with a clinical proton beam. To maximize the reaction rate, we used sodium borocaptate (BSH) with natural boron content. Boron-Neutron Capture Therapy (BNCT) uses $^{10}$B-enriched BSH for neutron irradiation-triggered alpha-particles. We recorded significantly increased cellular lethality and chromosome aberration complexity. A strategy combining protontherapy ballistic precision with the higher RBE promised by BNCT and $^{12}$C-ion therapy is thus demonstrated.
△ Less
Submitted 25 January, 2017;
originally announced January 2017.