-
Predicting Opioid Use Disorder from Longitudinal Healthcare Data using Multi-stream Transformer
Authors:
Sajjad Fouladvand,
Jeffery Talbert,
Linda P. Dwoskin,
Heather Bush,
Amy Lynn Meadows,
Lars E. Peterson,
Ramakanth Kavuluru,
** Chen
Abstract:
Opioid Use Disorder (OUD) is a public health crisis costing the US billions of dollars annually in healthcare, lost workplace productivity, and crime. Analyzing longitudinal healthcare data is critical in addressing many real-world problems in healthcare. Leveraging the real-world longitudinal healthcare data, we propose a novel multi-stream transformer model called MUPOD for OUD identification. M…
▽ More
Opioid Use Disorder (OUD) is a public health crisis costing the US billions of dollars annually in healthcare, lost workplace productivity, and crime. Analyzing longitudinal healthcare data is critical in addressing many real-world problems in healthcare. Leveraging the real-world longitudinal healthcare data, we propose a novel multi-stream transformer model called MUPOD for OUD identification. MUPOD is designed to simultaneously analyze multiple types of healthcare data streams, such as medications and diagnoses, by attending to segments within and across these data streams. Our model tested on the data from 392,492 patients with long-term back pain problems showed significantly better performance than the traditional models and recently developed deep learning models.
△ Less
Submitted 7 July, 2021; v1 submitted 15 March, 2021;
originally announced March 2021.
-
Statistical randomization test for QCD intermittency in a single-event distribution
Authors:
Leif E. Peterson
Abstract:
A randomization test was developed to determine the statistical significance of QCD intermittency in single-event distributions. A total of 96 simulated intermittent distributions based on standard normal Gaussian distributions of size N=500, 1000, 1500, 2000, 4000, 8000, 16000, and 32000 containing induced holes and spikes were tested for intermittency. Non-intermittent null distributions were…
▽ More
A randomization test was developed to determine the statistical significance of QCD intermittency in single-event distributions. A total of 96 simulated intermittent distributions based on standard normal Gaussian distributions of size N=500, 1000, 1500, 2000, 4000, 8000, 16000, and 32000 containing induced holes and spikes were tested for intermittency. Non-intermittent null distributions were also simulated as part of the test. A log-linear model was developed to simultaneously test the significance of fit coefficients for the y-intercept and slope contribution to ln(F_2) vs. ln(M) from both the intermittent and null distributions. Statistical power was also assessed for each fit coefficient to reflect the proportion of times out of 1000 tests each coefficient was statistically significant, given the induced effect size and sample size of the Gaussians. Results indicate that the slope of ln(F_2) vs. ln(M) for intermittent distributions increased with decreasing sample size, due to artificially-induced holes occurring in sparse histograms. For intermittent Gaussians with 4000 variates, there was approximately 70% power to detect a slope difference of 0.02 between intermittent and null distributions. For sample sizes of 8000 and greater, there was more than 70% power to detect a slope difference of 0.01. The randomization test performed satisfactorily since the power of the test for intermittency decreased with decreasing sample size. Power was near-zero when the test was applied to null distributions. The randomization test can be used to establish the statistical significance of intermittency in empirical single-event Gaussian distributions.
△ Less
Submitted 5 April, 2004;
originally announced April 2004.
-
HEXTE Studies of Sco X-1 Spectra: Detections of Hard X-Ray Tails Beyond 200 keV
Authors:
F. D'Amico,
W. A. Heindl,
R. E. Rothschild,
L. E. Peterson,
D. E. Gruber,
M. Pelling,
J. A. Tomsick
Abstract:
Using the HEXTE experiment on-board the RXTE satellite, we performed a search for hard X-ray tails in Sco X-1 spectra. We found strong evidence for the presence of such a non-thermal component on several occasions. Using the PCA/RXTE we were able to track the position of the source along the Z diagram, and we observed that the presence of the hard X-ray tail is not confined to a particular regio…
▽ More
Using the HEXTE experiment on-board the RXTE satellite, we performed a search for hard X-ray tails in Sco X-1 spectra. We found strong evidence for the presence of such a non-thermal component on several occasions. Using the PCA/RXTE we were able to track the position of the source along the Z diagram, and we observed that the presence of the hard X-ray tail is not confined to a particular region. However, we found a correlation between the power law index of the non-thermal component and the position of the source in the Z diagram, suggesting that the hard X-ray spectrum (i.e., E > 50 keV) becomes flatter as the mass accretion rate increases. We were also able to study the temporal variation of the appearance/absence of the hard X-ray component. With our derived luminosities, we were also able to test the idea that X-ray luminosities can be used to distinguish between X-ray binary systems containing neutron stars and black holes.
△ Less
Submitted 22 January, 2001;
originally announced January 2001.
-
The Spectrum of Diffuse Cosmic Hard X-Rays Measured with HEAO-1
Authors:
D. E. Gruber,
J. L. Matteson,
L. E. Peterson,
G. V. Jung
Abstract:
The spectrum of the diffuse isotropic component of cosmic X-rays over the 13-180 keV range was determined by the UCSD/MIT Hard X-Ray and Gamma-Ray instrument (HEAO A4) on the High Energy Astronomical Observatory-1 (HEAO-1). The instrument consists of a complex of actively shielded and collimated scintillation counters, including the Low Energy Detector set from which the data reported here were…
▽ More
The spectrum of the diffuse isotropic component of cosmic X-rays over the 13-180 keV range was determined by the UCSD/MIT Hard X-Ray and Gamma-Ray instrument (HEAO A4) on the High Energy Astronomical Observatory-1 (HEAO-1). The instrument consists of a complex of actively shielded and collimated scintillation counters, including the Low Energy Detector set from which the data reported here were obtained. These data join smoothly with the spectrum at lower energies reported by the GSFC HEAO A2 instrument and with that measured to 400 keV by the HEAO A4 Medium Energy Detectors. The HEAO data set also joins the recent results from COMPTEL on the Compton Gamma-Ray Observatory in the 1-10 MeV range, which failed to confirm the existence of an "MeV bump" in this range. Although the spectrum over the entire range 3 keV < E < 100 GeV can be fit by a simple empirical analytic expression, the origin is likely due to a number of distinct source components. The prevailing idea for the origin is that the hard X-ray spectrum is due to X-rays from various AGN components, particularly Seyfert galaxies extending to cosmological distances, and that the low energy gamma-rays may be due to emission from type 1a Supernovae, also integrated to cosmological distances. The higher energy gamma-ray spectrum defined by EGRET, also on the CGRO, may be due to unresolved gamma-ray emitting blazars. Models of production by these source components, extrapolated to the present epoch, must reproduce the observationally derived spectrum.
△ Less
Submitted 31 March, 1999;
originally announced March 1999.
-
The X-ray Spectrum of the Plerionic System PSR B1509-58/MSH 15-52
Authors:
D. Marsden,
P. R. Blanco,
D. E. Gruber,
W. A. Heindl,
M. R. Pelling,
L. E. Peterson,
R. E. Rothschild,
A. H. Rots,
K. Jahoda,
D. J. Macomb
Abstract:
We present the results of observations of the PSR B1509$-$58/MSH 15$-$52 system in X-rays ($2-250$ keV) by the Rossi X-ray Timing Explorer. The spectra of the peak of the pulsed component (radio phase $0.17-0.53$) is fit by a power law of photon index $1.36\pm0.01$, with no evidence of a high energy spectral break seen up to $\sim200$ keV. For the off-pulse spectral component, the spectrum from…
▽ More
We present the results of observations of the PSR B1509$-$58/MSH 15$-$52 system in X-rays ($2-250$ keV) by the Rossi X-ray Timing Explorer. The spectra of the peak of the pulsed component (radio phase $0.17-0.53$) is fit by a power law of photon index $1.36\pm0.01$, with no evidence of a high energy spectral break seen up to $\sim200$ keV. For the off-pulse spectral component, the spectrum from $2-250$ keV is fit by a power law of photon index $2.215\pm0.005$. An iron emission line at 6.7 keV with an equivalent width of 129 eV improves the fit, but only at a marginal significance. Thermal bremsstrahlung and Raymond-Smith models produce much worse fits to the unpulsed data. The lack of a high energy spectral break in the pulsed emission implies an efficiency of $\geq 3%$ in the conversion of pulsar spindown energy to pulsed X-rays in the system.
△ Less
Submitted 10 October, 1997;
originally announced October 1997.