Exploring the parameter space of MagLIF implosions using similarity scaling. III. Rise-time scaling
Authors:
D. E. Ruiz,
P. F. Schmit,
M. R. Weis,
K. J. Peterson,
M. K. Matzen
Abstract:
Magnetized Liner Inertial Fusion (MagLIF) is a z-pinch magneto-inertial-fusion (MIF) concept studied on the Z Machine at Sandia National Laboratories. Two important metrics characterizing current delivery to a z-pinch load are the peak current and the current-rise time, which is roughly the time interval to reach peak current. It is known that, when driving a z-pinch load with a longer current-ris…
▽ More
Magnetized Liner Inertial Fusion (MagLIF) is a z-pinch magneto-inertial-fusion (MIF) concept studied on the Z Machine at Sandia National Laboratories. Two important metrics characterizing current delivery to a z-pinch load are the peak current and the current-rise time, which is roughly the time interval to reach peak current. It is known that, when driving a z-pinch load with a longer current-rise time, the performance of the z-pinch decreases. However, a theory to understand and quantify this effect is still lacking. In this paper, we utilize a framework based on similarity scaling to analytically investigate the variations in performance of MagLIF loads when varying the current-rise time, or equivalently, the implosion timescale. To maintain similarity between the implosions, we provide the scaling prescriptions of the experimental input parameters defining a MagLIF load and derive the scaling laws for the stagnation conditions and for various performance metrics. We compare predictions of the theory to 2D numerical simulations using the radiation, magneto-hydrodynamic code HYDRA. For several metrics, we find acceptable agreement between the theory and simulations. Our results show that the voltage near the MagLIF load follows a weak scaling law $\smash{\varphi_{\rm load} \propto t_\varphi^{-0.12}}$ with respect to the characteristic timescale $t_\varphi$ of the voltage source, instead of the ideal $\smash{\varphi_{\rm load} \propto t_\varphi^{-1}}$ scaling. This occurs because the imploding height of the MagLIF load must increase to preserve end losses. As a consequence of the longer imploding liners, the required total laser preheat energy and delivered electric energy increase. Overall, this study may help understand the trade-offs of the MagLIF design space when considering future pulsed-power generators with shorter and longer current-rise times.
△ Less
Submitted 5 January, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
Clinical Concept Extraction: a Methodology Review
Authors:
Sunyang Fu,
David Chen,
Huan He,
Sijia Liu,
Sungrim Moon,
Kevin J Peterson,
Feichen Shen,
Liwei Wang,
Yanshan Wang,
Andrew Wen,
Yiqing Zhao,
Sunghwan Sohn,
Hongfang Liu
Abstract:
Background Concept extraction, a subdomain of natural language processing (NLP) with a focus on extracting concepts of interest, has been adopted to computationally extract clinical information from text for a wide range of applications ranging from clinical decision support to care quality improvement.
Objectives In this literature review, we provide a methodology review of clinical concept ext…
▽ More
Background Concept extraction, a subdomain of natural language processing (NLP) with a focus on extracting concepts of interest, has been adopted to computationally extract clinical information from text for a wide range of applications ranging from clinical decision support to care quality improvement.
Objectives In this literature review, we provide a methodology review of clinical concept extraction, aiming to catalog development processes, available methods and tools, and specific considerations when develo** clinical concept extraction applications.
Methods Based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, a literature search was conducted for retrieving EHR-based information extraction articles written in English and published from January 2009 through June 2019 from Ovid MEDLINE In-Process & Other Non-Indexed Citations, Ovid MEDLINE, Ovid EMBASE, Scopus, Web of Science, and the ACM Digital Library.
Results A total of 6,686 publications were retrieved. After title and abstract screening, 228 publications were selected. The methods used for develo** clinical concept extraction applications were discussed in this review.
△ Less
Submitted 10 August, 2020; v1 submitted 24 October, 2019;
originally announced October 2019.
-
Exploring magnetized liner inertial fusion with a semi-analytic model
Authors:
R. D. McBride,
S. A. Slutz,
R. A. Vesey,
M. R. Gomez,
A. B. Sefkow,
S. B. Hansen,
P. F. Knapp,
P. F. Schmit,
M. Geissel,
A. J. Harvey-Thompson,
C. A. Jennings,
E. C. Harding,
T. J. Awe,
D. C. Rovang,
K. D. Hahn,
M. R. Martin,
K. R. Cochrane,
K. J. Peterson,
G. A. Rochau,
J. L. Porter,
W. A. Stygar,
E. M. Campbell,
C. W. Nakhleh,
M. C. Herrmann,
M. E. Cuneo
, et al. (1 additional authors not shown)
Abstract:
In this paper, we explore magnetized liner inertial fusion (MagLIF) [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] using a semi-analytic model [R. D. McBride and S. A. Slutz, Phys. Plasmas 22, 052708 (2015)]. Specifically, we present simulation results from this model that: (a) illustrate the parameter space, energetics, and overall system efficiencies of MagLIF; (b) demonstrate the depende…
▽ More
In this paper, we explore magnetized liner inertial fusion (MagLIF) [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] using a semi-analytic model [R. D. McBride and S. A. Slutz, Phys. Plasmas 22, 052708 (2015)]. Specifically, we present simulation results from this model that: (a) illustrate the parameter space, energetics, and overall system efficiencies of MagLIF; (b) demonstrate the dependence of radiative loss rates on the radial fraction of the fuel that is preheated; (c) explore some of the recent experimental results of the MagLIF program at Sandia National Laboratories [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)]; (d) highlight the experimental challenges presently facing the MagLIF program; and (e) demonstrate how increases to the preheat energy, fuel density, axial magnetic field, and drive current could affect future MagLIF performance.
△ Less
Submitted 13 January, 2016; v1 submitted 25 November, 2015;
originally announced November 2015.
-
Model-independent determination of the strong-phase difference between D^0 and D^0-bar-> K^0_S,L h^+ h^- (h=pi,K) and its impact on the measurement of the CKM angle gamma/phi_3
Authors:
J. Libby,
M. Kornicer,
R. E. Mitchell,
M. R. Shepherd,
C. M. Tarbert,
D. Besson,
T. K. Pedlar,
J. Xavier,
D. Cronin-Hennessy,
J. Hietala,
P. Zweber,
S. Dobbs,
Z. Metreveli,
K. K. Seth,
A. Tomaradze,
T. Xiao,
S. Brisbane,
S. Malde,
L. Martin,
A. Powell,
P. Spradlin,
G. Wilkinson,
H. Mendez,
J. Y. Ge,
D. H. Miller
, et al. (59 additional authors not shown)
Abstract:
We report the first determination of the relative strong-phase difference between D^0 -> K^0_S,L K^+ K^- and D^0-bar -> K^0_S,L K^+ K^-. In addition, we present updated measurements of the relative strong-phase difference between D^0 -> K^0_S,L pi^+ pi^- and D^0-bar -> K^0_S,L pi^+ pi^-. Both measurements exploit the quantum coherence between a pair of D^0 and D^0-bar mesons produced from psi(3770…
▽ More
We report the first determination of the relative strong-phase difference between D^0 -> K^0_S,L K^+ K^- and D^0-bar -> K^0_S,L K^+ K^-. In addition, we present updated measurements of the relative strong-phase difference between D^0 -> K^0_S,L pi^+ pi^- and D^0-bar -> K^0_S,L pi^+ pi^-. Both measurements exploit the quantum coherence between a pair of D^0 and D^0-bar mesons produced from psi(3770) decays. The strong-phase differences measured are important for determining the Cabibbo-Kobayashi-Maskawa angle gamma/phi_3 in B^- -> K^- D^0-tilde decays, where D^0-tilde is a D^0 or D^0-bar meson decaying to K^0_S h^+ h^- (h=pi,K), in a manner independent of the model assumed to describe the D^0 -> K^0_S h^+ h^- decay. Using our results, the uncertainty in gamma/phi_3 due to the error on the strong-phase difference is expected to be between 1.7 and 3.9 degrees for an analysis using B^- K^- D^0-tilde D^0-tilde -> K^0_S pi^+ pi^- decays, and between 3.2 and 3.9 degrees for an analysis based on B^- -> K^- D^0-tilde, D^0-tilde -> K^0_S K^+ K^- decays. A measurement is also presented of the CP-odd fraction, F_-, of the decay D^0 -> K^0_S K^+ K^- in the region of the phi -> K^+ K^- resonance. We find that in a region within 0.01 GeV^2/c^4 of the nominal phi mass squared F_- > 0.91 at the 90% confidence level.
△ Less
Submitted 2 February, 2016; v1 submitted 13 October, 2010;
originally announced October 2010.