Numerical simulation of self-oscillating catalytic reaction in a plug-flow reactor
Authors:
N. V. Peskov,
M. M. Slinko
Abstract:
Self-oscillations in some oxidation reactions on metal catalysts are associated with periodic oxidation/reduction of the catalyst surface. If the reaction proceeds in a flow reactor at atmospheric pressure, then the reaction dynamics is complicated by the mass transfer in the gas phase. In this paper, the reaction in a flow reactor is described by an 1D system of advection-diffusion-reaction equat…
▽ More
Self-oscillations in some oxidation reactions on metal catalysts are associated with periodic oxidation/reduction of the catalyst surface. If the reaction proceeds in a flow reactor at atmospheric pressure, then the reaction dynamics is complicated by the mass transfer in the gas phase. In this paper, the reaction in a flow reactor is described by an 1D system of advection-diffusion-reaction equations with an abstract STM-type kinetic model of the surface catalytic reaction. The dependencies of the solution of the system on the reaction parameters, the intensity of diffusion in the adsorption layer, and on the gas flow rate are studied numerically. Solutions such as localized oscillations ("breathing" structures) and mobile oxidation/reduction fronts on the catalyst surface are constructed.
△ Less
Submitted 21 March, 2023;
originally announced March 2023.
-
Numerical simulation of heat extraction by a coaxial ground heat exchanger under freezing conditions
Authors:
G. P. Vasilyev,
N. V. Peskov,
T. M. Lysak
Abstract:
A new finite-difference model of heat transfer inside a shallow coaxial ground heat exchanger and in the surrounding layered soil is presented, taking into account the freezing of ground moisture. Three modes of heat exchanger operation are numerically simulated: stationary mode, transient mode and controlled mode. In the stationary mode, estimates of the sensitivity of the heat carrier fluid outl…
▽ More
A new finite-difference model of heat transfer inside a shallow coaxial ground heat exchanger and in the surrounding layered soil is presented, taking into account the freezing of ground moisture. Three modes of heat exchanger operation are numerically simulated: stationary mode, transient mode and controlled mode. In the stationary mode, estimates of the sensitivity of the heat carrier fluid outlet temperature to changes in the heat exchanger parameters are calculated. In all modes, close attention is paid to demonstrating the difference in the results at a negative temperature of the fluid, calculated with and without taking into account the freezing of ground moisture. It is shown that this difference, caused by the zero-curtain effect, can range from 10% in the stationary mode to 35% in the control mode.
△ Less
Submitted 20 May, 2022;
originally announced June 2022.
-
Heat balance model for long-term prediction of the thermal regime of a subway tunnel and surrounding soil
Authors:
G. P. Vasillyev,
N. V. Peskov,
T. M. Lysak
Abstract:
For a long-term forecast of the average air temperature in a metro tunnel and surrounding soil, heat balance conditions are modeled in a system that includes two parallel tunnels, a near-tunnels underground space, the earth's surface and atmospheric air with seasonal temperature variation. It is assumed that the air in the tunnels is well mixed, and the thermal effect of ventilation is taken into…
▽ More
For a long-term forecast of the average air temperature in a metro tunnel and surrounding soil, heat balance conditions are modeled in a system that includes two parallel tunnels, a near-tunnels underground space, the earth's surface and atmospheric air with seasonal temperature variation. It is assumed that the air in the tunnels is well mixed, and the thermal effect of ventilation is taken into account by replacing the air in the tunnels with atmospheric air. The system of heat balance equations is solved numerically by the finite element method. A numerical analysis of the influences of the model parameters on the average temperature in the tunnels and surrounding soil is carried out. The dimensions of the soil region with an elevated temperature, located between the tunnels, are estimated.
△ Less
Submitted 1 September, 2022; v1 submitted 2 November, 2020;
originally announced November 2020.
-
Finite element solution of the Fokker-Planck equation for single domain particles
Authors:
N. V. Peskov
Abstract:
The Fokker-Planck equation derived by Brown for the probability density function of the orientation of the magnetic moment of single domain particles is one of the basic equations in the theory of superparamagnetism. Usually this equation is solved by expanding the solution into a series of spherical harmonics, which in this case is a complex and cumbersome procedure. This article presents the imp…
▽ More
The Fokker-Planck equation derived by Brown for the probability density function of the orientation of the magnetic moment of single domain particles is one of the basic equations in the theory of superparamagnetism. Usually this equation is solved by expanding the solution into a series of spherical harmonics, which in this case is a complex and cumbersome procedure. This article presents the implementation procedure and some results of the numerical solution of the Fokker-Planck equation using the finite element method. A method for creating a sequence of triangular grids on the surface of a sphere based on an inscribed icosahedron is described. The equations of the finite element method are derived and examples of numerical solutions are presented. The processes of magnetization and demagnetization under heating of a particle with cubic magnetic anisotropy are simulated.
△ Less
Submitted 5 January, 2020;
originally announced January 2020.