Individualization of atrial tachycardia models for clinical applications: Performance of fiber-independent model
Authors:
Jiyue He,
Arkady Pertsov,
John Bullinga,
Rahul Mangharam
Abstract:
One of the challenges in the development of patient-specific models of cardiac arrhythmias for clinical applications has been accounting for myocardial fiber organization. The fiber varies significantly from heart to heart, but cannot be directly measured in live tissue. The goal of this paper is to evaluate in-silico the accuracy of left atrium activation maps produced by a fiber-independent (iso…
▽ More
One of the challenges in the development of patient-specific models of cardiac arrhythmias for clinical applications has been accounting for myocardial fiber organization. The fiber varies significantly from heart to heart, but cannot be directly measured in live tissue. The goal of this paper is to evaluate in-silico the accuracy of left atrium activation maps produced by a fiber-independent (isotropic) model with tuned diffusion coefficients, compares to a model incorporating myocardial fibers with the same geometry. For this study we utilize publicly available DT-MRI data from 7 ex-vivo hearts. The comparison is carried out in 51 cases of focal and rotor arrhythmias located in different regions of the atria. On average, the local activation time accuracy is 96% for focal and 93% for rotor arrhythmias. Given its reasonably good performance and the availability of readily accessible data for model tuning in cardiac ablation procedures, the fiber-independent model could be a promising tool for clinical applications.
△ Less
Submitted 20 July, 2023;
originally announced July 2023.
-
Fiber Organization has Little Effect on Electrical Activation Patterns during Focal Arrhythmias in the Left Atrium
Authors:
Jiyue He,
Arkady M. Pertsov,
Elizabeth M. Cherry,
Flavio H. Fenton,
Caroline H. Roney,
Steven A. Niederer,
Zirui Zang,
Rahul Mangharam
Abstract:
Over the past two decades there has been a steady trend towards the development of realistic models of cardiac conduction with increasing levels of detail. However, making models more realistic complicates their personalization and use in clinical practice due to limited availability of tissue and cellular scale data. One such limitation is obtaining information about myocardial fiber organization…
▽ More
Over the past two decades there has been a steady trend towards the development of realistic models of cardiac conduction with increasing levels of detail. However, making models more realistic complicates their personalization and use in clinical practice due to limited availability of tissue and cellular scale data. One such limitation is obtaining information about myocardial fiber organization in the clinical setting. In this study, we investigated a chimeric model of the left atrium utilizing clinically derived patient-specific atrial geometry and a realistic, yet foreign for a given patient fiber organization. We discovered that even significant variability of fiber organization had a relatively small effect on the spatio-temporal activation pattern during regular pacing. For a given pacing site, the activation maps were very similar across all fiber organizations tested.
△ Less
Submitted 22 April, 2023; v1 submitted 29 October, 2022;
originally announced October 2022.
-
Patient-Specific Heart Model Towards Atrial Fibrillation
Authors:
Jiyue He,
Arkady Pertsov,
Sanjay Dixit,
Katie Walsh,
Eric Toolan,
Rahul Mangharam
Abstract:
Atrial fibrillation is a heart rhythm disorder that affects tens of millions people worldwide. The most effective treatment is catheter ablation. This involves irreversible heating of abnormal cardiac tissue facilitated by electroanatomical map**. However, it is difficult to consistently identify the triggers and sources that may initiate or perpetuate atrial fibrillation due to its chaotic beha…
▽ More
Atrial fibrillation is a heart rhythm disorder that affects tens of millions people worldwide. The most effective treatment is catheter ablation. This involves irreversible heating of abnormal cardiac tissue facilitated by electroanatomical map**. However, it is difficult to consistently identify the triggers and sources that may initiate or perpetuate atrial fibrillation due to its chaotic behavior. We developed a patient-specific computational heart model that can accurately reproduce the activation patterns to help in localizing these triggers and sources. Our model has high spatial resolution, with whole-atrium temporal synchronous activity, and has patient-specific accurate electrophysiological activation patterns. A total of 15 patients data were processed: 8 in sinus rhythm, 6 in atrial flutter and 1 in atrial tachycardia. For resolution, the average simulation geometry voxel is a cube of 2.47 mm length. For synchrony, the model takes in about 1,500 local electrogram recordings, optimally fits parameters to the individual's atrium geometry and then generates whole-atrium activation patterns. For accuracy, the average local activation time error is 5.47 ms for sinus rhythm, 10.97 ms for flutter and tachycardia; and the average correlation is 0.95 for sinus rhythm, 0.81 for flutter and tachycardia. This promising result demonstrates our model is an effective building block in capturing more complex rhythms such as atrial fibrillation to guide physicians for effective ablation therapy.
△ Less
Submitted 23 October, 2022;
originally announced October 2022.
-
The soft X-ray spectrometer polarimeter SolpeX
Authors:
J. Sylwester,
M. Stęślicki,
J. Bąkała,
S. Płocieniak,
Ż. Szaforz,
M. Kowaliński,
D. Ścisłowski,
P. Podgórski,
T. Mrozek,
J. Barylak,
A. Makowski,
M. Siarkowski,
Z. Kordylewski,
B. Sylwester,
S. Kuzin,
A. Kirichenko,
A. Pertsov,
S. Bogachev
Abstract:
We present a novel X-ray assembly of functionally related instrument blocks intended to measure solar flare and active region (AR) spectra from within the Russian instrument complex KORTES, to be mounted aboard the International Space Station (ISS). SolpeX consists of three blocks: fast-rotating multiple flat crystal Bragg spectrometer, pin-hole X-ray spectral imager and Bragg polarimeter. This co…
▽ More
We present a novel X-ray assembly of functionally related instrument blocks intended to measure solar flare and active region (AR) spectra from within the Russian instrument complex KORTES, to be mounted aboard the International Space Station (ISS). SolpeX consists of three blocks: fast-rotating multiple flat crystal Bragg spectrometer, pin-hole X-ray spectral imager and Bragg polarimeter. This combination of measuring blocks will offer an opportunity to detect/measure possible X-ray polarization in soft X-ray emission lines/continuum and record spectra of solar flares, in particular during their impulsive phases. Polarized Bremsstrahlung and line emission may arise from presence of directed particle beams colliding with denser regions of flares. As a result of evaporation, the X-ray spectral-components are expected to be Doppler shifted, which will also be measured.
In this paper, we present details of the construction of three SolpeX blocks and discuss their functionality. Delivery of KORTES with SolpeX to ISS is expected in 2020/2021.
△ Less
Submitted 14 March, 2019;
originally announced March 2019.