-
Brazilian COVID-19 data streaming
Authors:
Nívea B. da Silva,
Luis Iván O. Valencia,
Fábio M. H. S. Filho,
Andressa C. S. Ferreira,
Felipe A. C. Pereira,
Guilherme L. de Oliveira,
Paloma F. Oliveira,
Moreno S. Rodrigues,
Pablo I. P. Ramos,
Juliane F. Oliveira
Abstract:
We collected individualized (unidentifiable) and aggregated openly available data from various sources related to suspected/confirmed SARS-CoV-2 infections, vaccinations, non-pharmaceutical government interventions, human mobility, and levels of population inequality in Brazil. In addition, a data structure allowing real-time data collection, curation, integration, and extract-transform-load proce…
▽ More
We collected individualized (unidentifiable) and aggregated openly available data from various sources related to suspected/confirmed SARS-CoV-2 infections, vaccinations, non-pharmaceutical government interventions, human mobility, and levels of population inequality in Brazil. In addition, a data structure allowing real-time data collection, curation, integration, and extract-transform-load processes for different objectives was developed. The granularity of this dataset (state- and municipality-wide) enables its application to individualized and ecological epidemiological studies, statistical, mathematical, and computational modeling, data visualization as well as the scientific dissemination of information on the COVID-19 pandemic in Brazil.
△ Less
Submitted 10 May, 2022;
originally announced May 2022.
-
A model-free tuning method for proportional-multi-resonant controllers
Authors:
Charles Lorenzini,
Luís Fernando Alves Pereira,
Alexandre Sanfelice Bazanella,
Gustavo R. Gonçalves da Silva
Abstract:
Resonant controllers are widely used in applications involving reference tracking and disturbance rejection of periodic signals. The controller design is typically performed by a trial-and-error approach or by means of time and resource-consuming analytic methods that require an accurate plant model, intricated mathematics and sophisticated tools. In this paper, we propose an easily implementable,…
▽ More
Resonant controllers are widely used in applications involving reference tracking and disturbance rejection of periodic signals. The controller design is typically performed by a trial-and-error approach or by means of time and resource-consuming analytic methods that require an accurate plant model, intricated mathematics and sophisticated tools. In this paper, we propose an easily implementable, model-free method for tuning a proportional-multi-resonant controller applicable to general linear time-invariant causal plants. Just like the Ziegler-Nichols methods, the proposed methodology consist in identifying one specific point of the plant's frequency response -- which is easily obtained in a relay with adjustable phase experiment -- and then designing the controller with simple tuning formulas and tables. The method is analyzed in detail for three examples, showing its practical appeal and wide applicability.
△ Less
Submitted 3 July, 2020;
originally announced July 2020.
-
Misaligned snowplough effect and the electromagnetic counterpart to black hole binary mergers
Authors:
Fabrícia A. C. Pereira,
Giuseppe Lodato,
Irapuan Rodrigues,
Márcio E. S. Alves,
Daniel J. Price
Abstract:
We estimate the accretion rates produced when a circumprimary gas disc is pushed into the primary supermassive black hole (SMBH) by the tidal force of the decaying secondary during a SMBH merger. Using the 3D Smoothed Particle Hydrodynamics (SPH) code {\sc phantom}, we extend previous investigations of co-planar discs to the case where the disc and binary orbital planes are misaligned. We consider…
▽ More
We estimate the accretion rates produced when a circumprimary gas disc is pushed into the primary supermassive black hole (SMBH) by the tidal force of the decaying secondary during a SMBH merger. Using the 3D Smoothed Particle Hydrodynamics (SPH) code {\sc phantom}, we extend previous investigations of co-planar discs to the case where the disc and binary orbital planes are misaligned. We consider a geometrically thin disc with inclination angles varying from 1 to 180 degrees and a binary with mass ratio $q$=$10^{-3}$. We find that discs with small inclination angles (< 10 degrees) produce an increase in luminosity exceeding the Eddington rate. By contrast, discs with inclinations between 20 and 30 degrees show a less pronounced rise in the accretion rate, whilst discs inclined by 180 degrees show no peak in the mass accretion rate. While previous analytic work predicted that the effective tidal torque drops with increasing inclination angle, we show that the misaligned snowplough effect remains important even for angles larger than the disc aspect ratio. The rise in the accretion rate produced by discs inclined at small angles to the binary orbit can produce an electromagnetic counterpart to the gravitational wave signal emitted from final stages of the binary orbital decay.
△ Less
Submitted 30 January, 2019;
originally announced January 2019.
-
A Generalized Forced Oscillation Method for tuning Proportional Resonant Controllers
Authors:
Charles Lorenzini,
Luís Fernando Alves Pereira,
Alexandre Sanfelice Bazanella
Abstract:
This paper proposes a tuning methodology for proportional resonant (PR) controllers by using the design philosophy of the Ziegler-Nichols forced oscillation method. Unlike such related methods that are usual for PID design, and those that have been recently proposed for PR controllers, the method in this paper is not restricted to plants whose Nyquist diagram crosses the negative real axis. It inv…
▽ More
This paper proposes a tuning methodology for proportional resonant (PR) controllers by using the design philosophy of the Ziegler-Nichols forced oscillation method. Unlike such related methods that are usual for PID design, and those that have been recently proposed for PR controllers, the method in this paper is not restricted to plants whose Nyquist diagram crosses the negative real axis. It involves a feedback experiment with a relay of adjustable phase, which allows the identification of the most appropriate point of the frequency response for each class of plants. The validation of the proposed method, which includes the identification experiment and specific tuning formulas that provide appropriate stability margins for each class of plants, is performed by means of numerical examples in a large variety of plants, showing its wide applicability.
△ Less
Submitted 17 July, 2018;
originally announced July 2018.
-
The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Maggiora,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri
, et al. (10 additional authors not shown)
Abstract:
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination…
▽ More
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors
Authors:
M. Alexeev,
R Birsa,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fishcher,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
K. Koenigsmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri,
F. A. Pereira
, et al. (10 additional authors not shown)
Abstract:
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are describe…
▽ More
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.
△ Less
Submitted 25 October, 2017;
originally announced October 2017.
-
Novel MPGD based Detectors of Single Photons in COMPASS RICH-1
Authors:
J. Agarwala M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy
, et al. (12 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly dev…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 24 October, 2017;
originally announced October 2017.
-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Can a falling ball lose speed?
Authors:
Paulo Murilo Castro de Oliveira,
Suzana Moss de Oliveira,
Felipe Augusto Pereira,
José Carlos Sartorelli
Abstract:
A small and light polystyrene ball is released without initial speed from a certain height above the floor. Then, it falls on air. The main responsible for the friction force against the movement is the wake of successive air vortices which form behind (above) the falling ball, a turbulent phenomenon. After the wake appears, the friction force compensates the Earth gravitational attraction and the…
▽ More
A small and light polystyrene ball is released without initial speed from a certain height above the floor. Then, it falls on air. The main responsible for the friction force against the movement is the wake of successive air vortices which form behind (above) the falling ball, a turbulent phenomenon. After the wake appears, the friction force compensates the Earth gravitational attraction and the ball speed stabilises in a certain limiting value Vl. Before the formation of the turbulent wake, however, the friction force is not strong enough, allowing the initially growing speed to surpass the future final value Vl. Only after the wake finally becomes long enough, the ball speed decreases and reaches the proper Vl.
△ Less
Submitted 21 May, 2010;
originally announced May 2010.