-
Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence
Authors:
A. Bornheim,
W. Lustermann,
K. Stachon,
G. Reales Gutiérrez,
A. Benaglia,
F. De Guio,
A. Ghezzi,
M. T. Lucchini,
M. Malberti,
S. Palluotto,
T. Tabarelli de Fatis,
M. Benettoni,
R. Carlin,
M. Tosi,
R. Rossin,
P. Meridiani,
R. Paramatti,
F. Santanastasio,
J. C. Silva,
J. Varela,
A. Heering,
A. Karneyeu,
Y. Musienko,
M. Wayne,
T. Anderson
, et al. (5 additional authors not shown)
Abstract:
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about…
▽ More
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.
△ Less
Submitted 23 August, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.
-
Comparative characterization study of LYSO:Ce crystals for timing applications
Authors:
F. M. Addesa,
P. Barria,
R. Bianco,
M. Campana,
F. Cavallari,
A. Cemmi,
M. Cipriani,
I. Dafinei,
B. ď Orsi,
D. del Re,
M. Diemoz,
G. ď Imperio,
E. Di Marco,
I. Di Sarcina,
M. Enculescu,
E. Longo,
M. T. Lucchini,
F. Marchegiani,
P. Meridiani,
S. Nisi,
G. Organtini,
F. Pandolfi,
R. Paramatti,
V. Pettinacci,
C. Quaranta
, et al. (6 additional authors not shown)
Abstract:
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce (…
▽ More
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce ($[Lu_{(1-x)}Y_x]_2SiO_5$:$Ce$) crystals is presented. It involves for the first time a large number of crystal samples (180) of the same size from a dozen of producers.The study consists of a comparative characterization of LYSO:Ce crystal products available on the market by mechanical, optical and scintillation measurements and aims specifically, to investigate key parameters of timing applications for HEP.
△ Less
Submitted 3 June, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Response of microchannel plates in ionization mode to single particles and electromagnetic showers
Authors:
A. Yu. Barnyakov,
M. Yu. Barnyakov,
L. Brianza,
F. Cavallari,
M. Cipriani,
V. Ciriolo,
D. del Re,
S. Gelli,
A. Ghezzi,
C. Gotti,
P. Govoni,
A. A. Katcin,
M. Malberti,
A. Martelli,
B. Marzocchi,
P. Meridiani,
G. Organtini,
R. Paramatti,
S. Pigazzini,
F. Preiato,
V. G. Prisekin,
S. Rahatlou,
C. Rovelli,
F. Santanastasio,
T. Tabarelli de Fatis
Abstract:
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic par…
▽ More
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic particles and to electromagnetic showers. Several prototypes, with different geometries and characteristics, were exposed to particle beams at the INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency are measured for single particles and as a function of the multiplicity of particles. Efficiencies between 50% and 90% to single relativistic particles are reached, and up to 100% in presence of a large number of particles. Time resolutions between 20ps and 30ps are obtained.
△ Less
Submitted 26 July, 2017;
originally announced July 2017.
-
Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target
Authors:
M. Marafini,
R. Paramatti,
D. Pinci,
G. Battistoni,
F. Collamati,
E. De Lucia,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
I. Mattei,
S. Muraro,
L. Piersanti,
M. Rovituso,
A. Rucinski,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atom…
▽ More
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments - protons, deuterons, and tritons - produced by $^4$He ion beams of 102, 125 and 145 MeV/u energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the Treatment Planning Software being developed for clinical use of $^4$He beams in clinical routine and the relative benchmarking of Monte Carlo algorithm predictions.
△ Less
Submitted 29 August, 2016;
originally announced August 2016.
-
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle
Authors:
A. Rucinski,
E. De Lucia,
G. Battistoni,
F. Collamati,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
M. Marafini,
I. Mattei,
S. Muraro,
R. Paramatti,
L. Piersanti,
D. Pinci,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. T…
▽ More
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. The secondary yields of protons produced along the primary beam path in PMMA target were obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The measured charged secondary yields and emission profiles are in agreement with the results reported in literature and confirm the feasibility of ion beam therapy range monitoring using 12C ion beam. The feasibility of range monitoring using charged secondary particles is also suggested for 4He ion beam.
△ Less
Submitted 16 August, 2016;
originally announced August 2016.
-
Design of a new tracking device for on-line dose monitor in ion therapy
Authors:
Giacomo Traini,
Giuseppe Battistoni,
Angela Bollella,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Fernando Ferroni,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Ilaria Mattei,
Federico Miraglia,
Silvia Muraro,
Riccardo Paramatti,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Elena Solfaroli-Camillocci,
Marco Toppi,
Cecilia Voena,
Vincenzo Patera
Abstract:
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam in…
▽ More
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a small calorimeter made of a pixelated Lutetium Fine Silicate crystal. Simulations have been performed to evaluate the achievable spatial resolution and a possible application of the device for the monitoring of the dose profile in a real treatment is presented.
△ Less
Submitted 28 July, 2016;
originally announced July 2016.
-
Secondary radiation measurements for particle therapy applications: prompt photons produced by $^{4}$He, $^{12}$C and $^{16}$O ion beams in a PMMA target
Authors:
Ilaria Mattei,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Silvia Muraro,
Riccardo Paramatti,
Vincenzo Patera,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Marco Toppi,
Giacomo Traini,
Cecilia Voena,
Giuseppe Battistoni
Abstract:
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of heli…
▽ More
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of helium and oxygen beams is growing due to their reduced multiple scattering inside the body and increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands for online dose monitoring techniques, crucial to improve the quality assurance of treatments. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Prompt photons are produced by nuclear de-excitation processes and, at present, different dose monitoring and beam range verification techniques based on the prompt γ detection have been proposed. It is hence of importance to perform the γ yield measurement in therapeutical-like conditions. In this paper we report the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a PMMA target. The measurements were performed at the Heidelberg Ion-beam Therapy center (HIT) with beams of different energies. A LYSO scintillator has been used as photon detector. The obtained γ yields for $^{12}$C ion beams are compared with results from literature, while no other results from $^{4}$He and $^{16}$O beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.
△ Less
Submitted 19 July, 2016; v1 submitted 26 May, 2016;
originally announced May 2016.
-
Polycrystalline para-terphenyl scintillator adopted in a $β^-$ detecting probe for radio-guided surgery
Authors:
Elena Solfaroli Camillocci,
Fabio Bellini,
Valerio Bocci,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Michela Marafini,
Ilaria Mattei,
Silvio Morganti,
Riccardo Paramatti,
Vincenzo Patera,
Davide Pinci,
Luigi Recchia,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Cecilia Voena
Abstract:
A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype h…
▽ More
A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype has been developed relying on the low density and high light yield of the diphenylbutadiene doped para-therphenyl organic scintillator. The scintillation light produced in a cylindrical crystal, 5 mm in diameter and 3 mm in height, is guided to a photo-multiplier tube by optical fibres. The custom readout electronics is designed to optimize its usage in terms of feedback to the surgeon, portability and remote monitoring of the signal. Tests show that with a radiotracer activity comparable to those administered for diagnostic purposes the developed probe can detect a 0.1 ml cancerous residual of meningioma in a few seconds.
△ Less
Submitted 9 November, 2015;
originally announced November 2015.
-
An Intraoperative $β^-$ Detecting Probe For Radio-Guided Surgery in Tumour Resection
Authors:
Andrea Russomando,
Fabio Bellini,
Valerio Bocci,
Giacomo Chiodi,
Francesco Collamati,
Erika De Lucia,
Raffaella Donnarumma,
Riccardo Faccini,
Carlo Mancini Terracciano,
Michela Marafini,
Riccardo Paramatti,
Vincenzo Patera,
%Davide Pinci,
Luigi Recchia,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Cecilia Voena,
Silvio Morganti
Abstract:
The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To vali…
▽ More
The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To validate the technique, prototypes of the intraoperative probe required by the technique to detect $β^-$ radiation have been developed. This paper discusses the design details of the device and the tests performed in laboratory. In such tests particular care has to be taken to reproduce the surgical field conditions. The innovative technique to produce specific phantoms and the dedicated testing protocols is described in detail.
△ Less
Submitted 6 November, 2015;
originally announced November 2015.
-
Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests
Authors:
R. Becker,
L. Bianchini,
G. Dissertori,
L. Djambazov,
M. Donegà,
W. Lustermann,
A. C. Marini,
F. Nessi-Tedaldi,
F. Pandolfi,
M. Peruzzi,
M. Schönenberger,
F. Cavallari,
I. Dafinei,
M. Diemoz,
C. Jorda Lope,
P. Meridiani,
M. Nuccetelli,
R. Paramatti,
F. Pellegrino,
F. Micheli,
G. Organtini,
S. Rahatlou,
L. Soffi,
L. Brianza,
P. Govoni
, et al. (7 additional authors not shown)
Abstract:
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the appar…
▽ More
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the apparatus. Particular emphasis is given to the response uniformity across the channel front face, and to the prototype's energy resolution.
△ Less
Submitted 8 June, 2015;
originally announced June 2015.
-
Response of microchannel plates to single particles and to electromagnetic showers
Authors:
L. Brianza,
F. Cavallari,
D. Del Re,
S. Gelli,
A. Ghezzi,
C. Gotti,
P. Govoni,
C. Jorda,
A. Martelli,
B. Marzocchi,
P. Meridiani,
G. Organtini,
R. Paramatti,
S. Pigazzini,
S. Rahatlou,
C. Rovelli,
F. Santanastasio,
T. Tabarelli de Fatis,
N. Trevisani,
[,
Università di Milano Bicocca,
INFN,
Sezione di Milano-Bicocca,
Sapienza - Università di Roma,
INFN
, et al. (1 additional authors not shown)
Abstract:
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time r…
▽ More
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time resolution of MCPs exceeds anything that has been previously used in calorimeters and, if exploited effectively, could aid in the event reconstruction at high luminosity colliders. Several prototypes of photodetectors with the amplification stage based on MCPs were exposed to cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The time resolution and the efficiency of the MCPs are measured as a function of the particle multiplicity, and the results used to model the response to high-energy showers.
△ Less
Submitted 10 April, 2015;
originally announced April 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Inclusive W and Z production with CMS at LHC startup
Authors:
Riccardo Paramatti
Abstract:
We report on potential for measurement of inclusive W and Z boson production cross section using initial data from the LHC. We have designed W and Z triggers, selection algorithms, and event reconstruction techniques for both muon and electron decay modes, for low luminosity operation of the LHC integrating up to about 10 pb-1. Initial calibrations and alignment accuracies are assumed. While the…
▽ More
We report on potential for measurement of inclusive W and Z boson production cross section using initial data from the LHC. We have designed W and Z triggers, selection algorithms, and event reconstruction techniques for both muon and electron decay modes, for low luminosity operation of the LHC integrating up to about 10 pb-1. Initial calibrations and alignment accuracies are assumed. While the accuracy of the cross section extracted will be dominated by the integral luminosity measurement, ratios of W and Z production, and asymmetry distributions will be important early measurements from LHC.
△ Less
Submitted 20 October, 2008;
originally announced October 2008.