-
Upright to supine image registration and contour propagation for thoracic patients
Authors:
M. C. Martire,
L. Volz,
C. Galeone,
M. Durante,
M. Pankuch,
C. Graeff
Abstract:
A renewed interest in upright therapy is currently driven by the availability of upright positioning and imaging systems. Aside from reduced cost, upright positioning possibly provides clinical advantages. The comparison between upright and supine particle therapy treatments can be biased through multiple variables, such as differences in the target contouring on the two CTs. We present a method f…
▽ More
A renewed interest in upright therapy is currently driven by the availability of upright positioning and imaging systems. Aside from reduced cost, upright positioning possibly provides clinical advantages. The comparison between upright and supine particle therapy treatments can be biased through multiple variables, such as differences in the target contouring on the two CTs. We present a method for upright and supine CT registration and structures propagation, and the investigation of an AI-based contouring tool for upright images. Six paired 4DCTs from Proton Therapy Collaboration Group registry were available from the Northwestern Medicine Proton Centre. Deformable image registration (DIR) is challenged by the different patient anatomy between postures, causing artefacts in the warped images. To achieve high quality contour propagation, we propose the construction of a region of interest covering the ribcage volume to overcome this problem. As no target contour ground truth was available, the registration quality analysis (QA) was performed on lung structures, for which dice score coefficient (DSC) and average Hausdorff distance (AHD) is reported. The TotalSegmentator tool, trained on supine dataset, was applied on upright images, verified against lung structures and used as additional comparison for contour propagation. The TotalSegmentator QA results in a maximum AHD of 2mm and a minimum DSC of 0.94. An average AHD of 1.5mm and 1.6mm, and an average DSC of 0.95 and 0.94 were obtained comparing the propagated volumes to manually contoured and AI structures, respectively. All AHD values are smaller than the CT slice distances. The developed framework allows for target propagation between upright and supine images, defining the first step to compare upright and supine therapy of thoracic patients and enabling the application of image fusion techniques in the upright therapy field.
△ Less
Submitted 17 June, 2024; v1 submitted 7 June, 2024;
originally announced June 2024.
-
A Comparison of Proton Stop** Power Measured with Proton CT and x-ray CT in Fresh Post-Mortem Porcine Structures
Authors:
Don F. DeJongh,
Ethan A. DeJongh,
Victor Rykalin,
Greg DeFillippo,
Mark Pankuch,
Andrew W. Best,
George Coutrakon,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Christina Sarosiek,
Reinhard W. Schulte,
John R. Winans,
Alec M. Block,
Courtney L. Hentz,
James S. Welsh
Abstract:
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stop** power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stop** power. We aim to demonstr…
▽ More
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stop** power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stop** power. We aim to demonstrate proton CT imaging with complex porcine samples, to analyze in detail three-dimensional regions of interest, and to compare proton stop** powers directly measured by proton CT to those determined from x-ray CT scans.
Methods: We have used a prototype proton imaging system with single proton tracking to acquire proton radiography and proton CT images of a sample of porcine pectoral girdle and ribs, and a pig's head. We also acquired close in time x-ray CT scans of the same samples, and compared proton stop** power measurements from the two modalities. In the case of the pig's head, we obtained x-ray CT scans from two different scanners, and compared results from high-dose and low-dose settings.
Results: Comparing our reconstructed proton CT images with images derived from x-ray CT scans, we find agreement within 1% to 2% for soft tissues, and discrepancies of up to 6% for compact bone. We also observed large discrepancies, up to 40%, for cavitated regions with mixed content of air, soft tissue, and bone, such as sinus cavities or tympanic bullae.
Conclusions: Our images and findings from a clinically realistic proton CT scanner demonstrate the potential for proton CT to be used for low-dose treatment planning with reduced margins.
△ Less
Submitted 29 October, 2021; v1 submitted 11 December, 2020;
originally announced December 2020.
-
Analysis of characteristics of images acquired with a prototype clinical proton radiography system
Authors:
Christina Sarosiek,
Ethan A. DeJongh,
George Coutrakon,
Don F. DeJongh,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Mark Pankuch,
Victor Rykalin,
John R. Winans,
James S. Welsh
Abstract:
Verification of patient specific proton stop** powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to verify integrated stop** power consistency with the treatment planning CT. Although a proton radiograph is a pixel by pixel representation of integrated stoppin…
▽ More
Verification of patient specific proton stop** powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to verify integrated stop** power consistency with the treatment planning CT. Although a proton radiograph is a pixel by pixel representation of integrated stop** powers, the image may also be of high enough quality and contrast to be used for patient alignment. This investigation qualifies the accuracy and image quality of a prototype proton radiography system on a clinical proton delivery system. We have developed a clinical prototype proton radiography system designed for integration into efficient clinical workflows. We tested the images obtained by this system for water-equivalent thickness (WET) accuracy, image noise, and spatial resolution. We evaluated the WET accuracy by comparing the average WET and rms error in several regions of interest (ROI) on a proton radiograph of a custom peg phantom. We measured the spatial resolution on a CATPHAN Line Pair phantom and a custom edge phantom by measuring the 10% value of the modulation transfer function (MTF). In addition, we tested the ability to detect proton range errors due to anatomical changes in a patient with a customized CIRS pediatric head phantom and inserts of varying WET placed in the posterior fossae of the brain. We took proton radiographs of the phantom with each insert in place and created difference maps between the resulting images. Integrated proton range was measured from an ROI in the difference maps.
△ Less
Submitted 24 February, 2021; v1 submitted 9 September, 2020;
originally announced September 2020.
-
Technical Note: A fast and monolithic prototype clinical proton radiography system optimized for pencil beam scanning
Authors:
Ethan A. DeJongh,
Don F. DeJongh,
Igor Polnyi,
Victor Rykalin,
Christina Sarosiek,
George Coutrakon,
Kirk L. Duffin,
Nicholas T. Karonis,
Caesar E. Ordoñez,
Mark Pankuch,
John R. Winans,
James S. Welsh
Abstract:
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods: The system tracks individual protons through one (X, Y) scintillating fiber tracker plane upstream and downstream of the object and into a 13 cm-thick scintill…
▽ More
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods: The system tracks individual protons through one (X, Y) scintillating fiber tracker plane upstream and downstream of the object and into a 13 cm-thick scintillating block residual energy detector. The fibers in the tracker planes are multiplexed into silicon photomultipliers (SiPMs) to reduce the number of electronics channels. The light signal from the residual energy detector is collected by 16 photomultiplier tubes (PMTs). Only four signals from the PMTs are output from each event, which allows for fast signal readout. A robust calibration method of the PMT signal to residual energy has been developed to obtain accurate proton images. The development of patient-specific scan patterns using multiple input energies allows for an image to be produced with minimal excess dose delivered to the patient. Results: The calibration of signals in the energy detector produces accurate residual range measurements limited by intrinsic range straggling. We measured the water-equivalent thickness (WET) of a block of solid water (physical thickness of 6.10 mm) with a proton radiograph. The mean WET from all pixels in the block was 6.13 cm (SD 0.02 cm). The use of patient-specific scan patterns using multiple input energies enables imaging with a compact range detector. Conclusions: We have developed a prototype clinical proton radiography system for pretreatment imaging in proton radiation therapy. We have optimized the system for use with pencil beam scanning systems and have achieved a reduction of size and complexity compared to previous designs.
△ Less
Submitted 5 January, 2021; v1 submitted 9 September, 2020;
originally announced September 2020.
-
Radiation Tests of Hamamatsu Multi-Pixel Photon Counters
Authors:
G. Blazey,
J. Colston,
A. Dyshkant,
K. Francis,
J. Kalnins,
S. A. Uzunyan,
V. Zutshi,
S. Hansen,
P. Rubinov,
E. C. Dukes,
Y. Oksuzian,
M. Pankuch
Abstract:
Results of radiation tests of Hamamatsu 2.0 x 2.0~mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs [1], are presented. Distinct sets of eight MPPCs were exposed to four different 1~MeV neutron equivalent doses of 200 MeV protons. Measurements of the breakdown voltage, gain and noise rates at different bias overvoltages, photoelectron thresholds, and LED illumination le…
▽ More
Results of radiation tests of Hamamatsu 2.0 x 2.0~mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs [1], are presented. Distinct sets of eight MPPCs were exposed to four different 1~MeV neutron equivalent doses of 200 MeV protons. Measurements of the breakdown voltage, gain and noise rates at different bias overvoltages, photoelectron thresholds, and LED illumination levels were taken before and after irradiation. No significant deterioration in performance was observed for breakdown voltage, gain, and response. Noise rates increased significantly with irradiation. These studies were undertaken in the context of MPPC requirements for the Cosmic Ray Veto detector of the Mu2e experiment at the Fermi National Accelerator Laboratory.
△ Less
Submitted 17 June, 2019;
originally announced June 2019.
-
A Real-time Image Reconstruction System for Particle Treatment Planning Using Proton Computed Tomography (pCT)
Authors:
Caesar E. Ordoñez,
Nicholas Karonis,
Kirk Duffin,
George Coutrakon,
Reinhard Schulte,
Robert Johnson,
Mark Pankuch
Abstract:
Proton computed tomography (pCT) is a novel medical imaging modality for map** the distribution of proton relative stop** power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range uncertainty margins are around 3.5%, pCT has the potential to provide more accurate measurements to within 1%. This improved efficiency will be beneficial to proton-t…
▽ More
Proton computed tomography (pCT) is a novel medical imaging modality for map** the distribution of proton relative stop** power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range uncertainty margins are around 3.5%, pCT has the potential to provide more accurate measurements to within 1%. This improved efficiency will be beneficial to proton-therapy planning and pre-treatment verification. A prototype pCT imaging device has recently been developed capable of rapidly acquiring low-dose proton radiographs of head-sized objects. We have also developed an advanced, fast image reconstruction software based on distributed computing that utilizes parallel processors and graphical processing units. The combination of fast data acquisition and fast image reconstruction will enable the availability of RSP images within minutes for use in clinical settings. The performance of our image reconstruction software has been evaluated using data collected by the prototype pCT scanner from several phantoms.
△ Less
Submitted 17 July, 2017;
originally announced July 2017.
-
Results from a Prototype Proton-CT Head Scanner
Authors:
R. P. Johnson,
V. A. Bashkirov,
G. Coutrakon,
V. Giacometti,
P. Karbasi,
N. T. Karonis,
C. E. Ordoñez,
M. Pankuch,
H. F. -W. Sadrozinski,
K. E. Schubert,
R. W. Schulte
Abstract:
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of mor…
▽ More
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stop** power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.
△ Less
Submitted 5 July, 2017;
originally announced July 2017.