Development of a low-level Ar-37 calibration standard
Authors:
R. M. Williams,
C. E. Aalseth,
T. W. Bowyer,
A. R. Day,
E. S. Fuller,
D. A. Haas,
J. C. Hayes,
E. W. Hoppe,
P. H. Humble,
M. E. Keillor,
B. D. LaFerriere,
E. K. Mace,
J. I. McIntyre,
H. S. Miley,
A. W. Myers,
J. L. Orrell,
C. T. Overman,
M. E. Panisko,
A. Seifert
Abstract:
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in develo** a process to generate and quantify low-level Ar-37 standards, which can be used to calibrate sensitive…
▽ More
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in develo** a process to generate and quantify low-level Ar-37 standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
Development of a low background liquid scintillation counter for a shallow underground laboratory
Authors:
J. L. Erchinger,
C. E. Aalseth,
B. E. Bernacki,
M. Douglas,
E. S. Fuller,
M. E. Keillor,
S. M. Morley,
C. A. Mullen,
J. L. Orrell,
M. E. Panisko,
G. A. Warren,
R. O. Williams,
M. E. Wright
Abstract:
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillati…
▽ More
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., $β$, $α$) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35 meters-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.
△ Less
Submitted 20 December, 2015;
originally announced December 2015.