Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer
Authors:
S. Marrone,
B. B. Wojtsekhowski,
A. Acha,
E. Cisbani,
M. Coman,
F. Cusanno,
C. W. de Jager,
R. De Leo,
H. Gao,
F. Garibaldi,
D. W. Higinbotham,
M. Iodice,
J. J. LeRose,
D. Macchia,
P. Markowitz,
E. Nappia,
F. Palmisano,
G. M. Urciuoli,
I. van der Werf,
H. Xiang,
L. Y. Zhu
Abstract:
We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found…
▽ More
We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found to be noticeably reduced in both detectors as a result of contamination, yellowing, of the aerogel material. Along with the details of the set-up, we illustrate the characteristics of the detectors during different time periods and the probable causes of the contamination. In particular we show that the replacement of the contaminated aerogel and parts of the reflecting material has almost restored the initial performance of the detectors.
△ Less
Submitted 25 October, 2008;
originally announced October 2008.
Chemical Analyses of Silicon Aerogel Samples
Authors:
I. van der Werf,
F. Palmisano,
R. De Leo,
S. Marrone
Abstract:
After five years of operating, two Aerogel counters: A1 and A2, taking data in Hall A at Jefferson Lab, suffered a loss of performance. In this note possible causes of degradation have been studied. In particular, various chemical and physical analyses have been carried out on several Aerogel tiles and on adhesive tape in order to reveal the presence of contaminants.
After five years of operating, two Aerogel counters: A1 and A2, taking data in Hall A at Jefferson Lab, suffered a loss of performance. In this note possible causes of degradation have been studied. In particular, various chemical and physical analyses have been carried out on several Aerogel tiles and on adhesive tape in order to reveal the presence of contaminants.
△ Less
Submitted 22 April, 2008;
originally announced April 2008.