Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Authors:
Luca Valenziano,
Francesco Cuttaia,
Adriano De Rosa,
Luca Terenzi,
Alberto Brighenti,
GianPaolo Cazzola,
Anna Garbesi,
Sergio Mariotti,
Giordano Orsi,
Luca Pagan,
Francesco Cavaliere,
Roberto Lapini,
Matteo Biggi,
Enzo Panagin,
Battaglia Paola,
Chris Butler,
Marco Bersanelli,
Ocleto D'Arcangelo,
Steve Levin,
Nazzareno Mandolesi,
Aniello Mennella,
Gianluca Morgante,
Gabriele Morigi,
Maura Sandri,
Alessandro Simonetto
, et al. (13 additional authors not shown)
Abstract:
The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal horns, one for each radiometer, 22 in total, facing small absorbing targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately 4.5 K. Horns and…
▽ More
The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal horns, one for each radiometer, 22 in total, facing small absorbing targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately 4.5 K. Horns and targets are separated by a small gap to allow thermal decoupling. Target and horn design is optimized for each of the LFI bands, centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the radiometer 20K module or connected via external electro-formed bended waveguides. The requirement of high stability of the reference signal imposed a careful design for the radiometric and thermal properties of the loads. Materials used for the manufacturing have been characterized for thermal, RF and mechanical properties. We describe in this paper the design and the performance of the reference system.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The Planck-LFI flight model composite waveguides
Authors:
O. D'Arcangelo,
L. Figini,
A. Simonetto,
F. Villa,
M. Pecora,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
S. Garavaglia,
P. Guzzi,
N. Mandolesi,
A. Mennella,
G. Morgante,
L. Pagan,
L. Valenziano
Abstract:
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts…
▽ More
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts is made with rectangular Wave Guides. Considerations of different nature (thermal, electromagnetic and mechanical), imposed stringent requirements on the WGs characteristics and drove their design. From the thermal point of view, the WG should guarantee good insulation between the FEM and the BEM sections to avoid overloading the cryocooler. On the other hand it is essential that the signals do not undergo excessive attenuation through the WG. Finally, given the different positions of the FEM modules behind the focal surface and the mechanical constraints given by the surrounding structures, different mechanical designs were necessary. A composite configuration of Stainless Steel and Copper was selected to satisfy all the requirements. Given the complex shape and the considerable length (about 1.5-2 m), manufacturing and testing the WGs was a challenge. This work deals with the development of the LFI WGs, including the choice of the final configuration and of the fabrication process. It also describes the testing procedure adopted to fully characterize these components from the electromagnetic point of view and the space qualification process they underwent. Results obtained during the test campaign are reported and compared with the stringent requirements. The performance of the LFI WGs is in line with requirements, and the WGs were successfully space qualified.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Simple Model of Membrane Proteins Including Solvent
Authors:
D. L. Pagan,
A. Shiryayev,
T. P. Connor,
J. D. Gunton
Abstract:
We report a numerical simulation for the phase diagram of a simple two dimensional model, similar to one proposed by Noro and Frenkel [J. Chem. Phys. \textbf{114}, 2477 (2001)] for membrane proteins, but one that includes the role of the solvent. We first use Gibbs ensemble Monte Caro simulations to determine the phase behavior of particles interacting via a square-well potential in two dimensio…
▽ More
We report a numerical simulation for the phase diagram of a simple two dimensional model, similar to one proposed by Noro and Frenkel [J. Chem. Phys. \textbf{114}, 2477 (2001)] for membrane proteins, but one that includes the role of the solvent. We first use Gibbs ensemble Monte Caro simulations to determine the phase behavior of particles interacting via a square-well potential in two dimensions for various values of the interaction range. A phenomenological model for the solute-solvent interactions is then studied to understand how the fluid-fluid coexistence curve is modified by solute-solvent interactions. It is shown that such a model can yield systems with liquid-liquid phase separation curves that have both upper and lower critical points, as well as closed loop phase diagrams, as is the case with the corresponding three dimensional model.
△ Less
Submitted 4 March, 2006; v1 submitted 27 October, 2005;
originally announced October 2005.
-
Role of solvent for globular proteins in solution
Authors:
A. Shiryayev,
D. L. Pagan,
J. D. Gunton,
D. S. Rhen,
A. Saxena,
T. Lookman
Abstract:
The properties of the solvent affect the behavior of the solution. We propose a model that accounts for the contribution of the solvent free energy to the free energy of globular proteins in solution. For the case of an attractive square well potential, we obtain an exact map** of the phase diagram of this model without solvent to the model that includes the solute-solvent contribution. In par…
▽ More
The properties of the solvent affect the behavior of the solution. We propose a model that accounts for the contribution of the solvent free energy to the free energy of globular proteins in solution. For the case of an attractive square well potential, we obtain an exact map** of the phase diagram of this model without solvent to the model that includes the solute-solvent contribution. In particular we find for appropriate choices of parameters upper critical points, lower critical points and even closed loops with both upper and lower critical points, similar to one found before [Macromolecules, 36, 5845 (2003)]. In the general case of systems whose interactions are not attractive square wells, this map** procedure can be a first approximation to understand the phase diagram in the presence of solvent. We also present simulation results for both the square well model and a modified Lennard-Jones model.
△ Less
Submitted 1 January, 2005;
originally announced January 2005.
-
Phase Behavior of Short Range Square Well Model
Authors:
D. L. Pagan,
J. D. Gunton
Abstract:
Various Monte Carlo techniques are used to determine the complete phase diagrams of the square well model for the attractive ranges $λ= 1.15$ and $λ= 1.25$. The results for the latter case are in agreement with earlier Monte Carlo simulations for the fluid-fluid coexistence curve and yield new results for the liquidus-solidus lines. Our results for $λ= 1.15$ are new. We find that the fluid-fluid…
▽ More
Various Monte Carlo techniques are used to determine the complete phase diagrams of the square well model for the attractive ranges $λ= 1.15$ and $λ= 1.25$. The results for the latter case are in agreement with earlier Monte Carlo simulations for the fluid-fluid coexistence curve and yield new results for the liquidus-solidus lines. Our results for $λ= 1.15$ are new. We find that the fluid-fluid critical point is metastable for both cases, with the case $λ= 1.25$ being just below the threshold value for metastability. We compare our results with prior studies and with experimental results for the gamma-II crystallin.
△ Less
Submitted 7 December, 2004;
originally announced December 2004.
-
A Finite-Size Scaling Study of a Model of Globular Proteins
Authors:
D. L. Pagan,
M. E. Gracheva,
J. D. Gunton
Abstract:
Grand canonical Monte Carlo simulations are used to explore the metastable fluid-fluid coexistence curve of the modified Lennard-Jones model of globular proteins of ten Wolde and Frenkel (Science, v277, 1975 (1997)). Using both mixed-field finite-size scaling and histogram reweighting methods, the joint distribution of density and energy fluctuations is analyzed at coexistence to accurately dete…
▽ More
Grand canonical Monte Carlo simulations are used to explore the metastable fluid-fluid coexistence curve of the modified Lennard-Jones model of globular proteins of ten Wolde and Frenkel (Science, v277, 1975 (1997)). Using both mixed-field finite-size scaling and histogram reweighting methods, the joint distribution of density and energy fluctuations is analyzed at coexistence to accurately determine the critical-point parameters. The subcritical coexistence region is explored using the recently developed hyper-parallel tempering Monte Carlo simulation method along with histogram reweighting to obtain the density distributions. The phase diagram for the metastable fluid-fluid coexistence curve is calculated in close proximity to the critical point, a region previously unattained by simulation.
△ Less
Submitted 2 February, 2004; v1 submitted 24 November, 2003;
originally announced November 2003.