Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
Authors:
P. Moskal,
T. Bednarski,
Sz. Niedzwiecki,
M. Silarski,
E. Czerwinski,
T. Kozik,
J. Chhokar,
M. Bała,
C. Curceanu,
R. Del Grande,
M. Dadgar,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk
, et al. (14 additional authors not shown)
Abstract:
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with…
▽ More
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.
△ Less
Submitted 25 August, 2020;
originally announced August 2020.
-
The J-PET detector -- a tool for precision studies of ortho-positronium decays
Authors:
K. Dulski,
S. D. Bass,
J. Chhokar,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
P. Kopka,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz
, et al. (19 additional authors not shown)
Abstract:
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events…
▽ More
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.
△ Less
Submitted 25 May, 2021; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Charged pion production in $\mathbf{Au+Au}$ collisions at $\mathbf{\sqrt{s_{NN}}}$ = 2.4$\mathbf{GeV}$
Authors:
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Boehmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
I. Ciepal,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Froehlich
, et al. (103 additional authors not shown)
Abstract:
We present high-statistic data on charged pion emission from Au+Au collisions at $\sqrt{s_{\rm{NN}}}$ = 2.4 GeV (corresponding to $E_{beam}$ = 1.23 A GeV) in four centrality classes in the range 0 - 40$\%$ of the most central collisions. The data are analyzed as a function of transverse momentum, transverse mass, rapidity, and polar angle. Pion multiplicity per participating nucleon decreases mode…
▽ More
We present high-statistic data on charged pion emission from Au+Au collisions at $\sqrt{s_{\rm{NN}}}$ = 2.4 GeV (corresponding to $E_{beam}$ = 1.23 A GeV) in four centrality classes in the range 0 - 40$\%$ of the most central collisions. The data are analyzed as a function of transverse momentum, transverse mass, rapidity, and polar angle. Pion multiplicity per participating nucleon decreases moderately with increasing centrality. The polar angular distributions are found to be non-isotropic even for the most central event class. Our results on pion multiplicity fit well into the general trend of the world data, but undershoot by $2.5 σ$ data from the FOPI experiment measured at slightly lower beam energy. We compare our data to state-of-the-art transport model calculations (PHSD, IQMD, PHQMD, GiBUU and SMASH) and find substantial differences between the measurement and the results of these calculations.
△ Less
Submitted 19 May, 2020; v1 submitted 18 May, 2020;
originally announced May 2020.
-
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
Authors:
N. G. Sharma,
M. Silarski,
J. Chhokar,
E. Czerwinski,
C. Curceanu,
K. Dulski,
K. Farbaniec,
A. Gajos,
R. Del Grande,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemien,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka
, et al. (10 additional authors not shown)
Abstract:
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of th…
▽ More
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
Proton number fluctuations in $\sqrt{s_{NN}}$ = 2.4 GeV Au+Au collisions studied with HADES
Authors:
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. B"ohmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Fr"ohlich,
T. Galatyuk
, et al. (95 additional authors not shown)
Abstract:
We present an analysis of proton number fluctuations in $\sqrt{s_{NN}}$ = 2.4 GeV Au+Au collisions measured with the High-Acceptance DiElectron Spectrometer (HADES) at GSI. With the help of extensive detector simulations done with IQMD transport model events including nuclear clusters, various nuisance effects influencing the observed proton cumulants have been investigated. Acceptance and efficie…
▽ More
We present an analysis of proton number fluctuations in $\sqrt{s_{NN}}$ = 2.4 GeV Au+Au collisions measured with the High-Acceptance DiElectron Spectrometer (HADES) at GSI. With the help of extensive detector simulations done with IQMD transport model events including nuclear clusters, various nuisance effects influencing the observed proton cumulants have been investigated. Acceptance and efficiency corrections have been applied as a function of fine grained rapidity and transverse momentum bins, as well as considering local track density dependencies. Next, the effects of volume changes within particular centrality selections have been considered and beyond-leading-order corrections have been applied to the data. The efficiency and volume corrected proton number moments and cumulants Kn of orders n = 1, . . . , 4 have been obtained as a function of centrality and phase-space bin, as well as the corresponding correlators C_n . We find that the observed correlators show a power-law scaling with the mean number of protons, i.e. $C_n \propto <N>^n$, indicative of mostly long-range multi-particle correlations in momentum space. We also present a comparison of our results with Au+Au collision data obtained at RHIC at similar centralities, but higher $\sqrt{s_{NN}}$.
△ Less
Submitted 30 August, 2020; v1 submitted 20 February, 2020;
originally announced February 2020.
-
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
Authors:
S. Sharma,
J. Chhokar,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
R. Del Grande,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed
, et al. (14 additional authors not shown)
Abstract:
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in…
▽ More
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph.
The experiment was performed using the $^{22}$Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, $^{22}$Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
Performance assessment of the 2$γ$ positronium imaging with the total-body PET scanners
Authors:
P. Moskal,
D. Kisielewska,
Z. Bura,
C. Chhokar,
C. Curceanu,
E. Czerwiński,
M. Dadgar 1,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
A. Kamińska,
Ł. Kapłon,
H. Karimi,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
P. Małczak
, et al. (17 additional authors not shown)
Abstract:
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image ba…
▽ More
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include: (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using $2γ$ annihilations, and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Simulations are conducted assuming that radiopharmaceutical is labelled with $^{44}Sc$ isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET, and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution the three cases were considered assuming that CRT is equal to 140ps, 50ps and 10ps. The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences is larger by a factor of 12.2 (for LYSO PET) and by factor of 4.7 (for plastic PET) with respect to the sensitivity for the standard $2γ$ imaging by LYSO PET scanners with AFOV=20cm.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Identical pion intensity interferometry at sqrt(s_{NN})=2.4 GeV
Authors:
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
T. Galatyuk
, et al. (94 additional authors not shown)
Abstract:
High-statistics $π^-π^-$ and $π^+π^+$ femtoscopy data are presented for Au+Au collisions at $\sqrt{s_\mathrm{NN}}=2.4$ GeV, measured with HADES at SIS18/GSI. The experimental correlation functions allow the determination of the space-time extent of the corresponding emission sources via a comparison to models. The emission source, parametrized as three-dimensional Gaussian distribution, is studied…
▽ More
High-statistics $π^-π^-$ and $π^+π^+$ femtoscopy data are presented for Au+Au collisions at $\sqrt{s_\mathrm{NN}}=2.4$ GeV, measured with HADES at SIS18/GSI. The experimental correlation functions allow the determination of the space-time extent of the corresponding emission sources via a comparison to models. The emission source, parametrized as three-dimensional Gaussian distribution, is studied in dependence on pair transverse momentum, azimuthal emission angle with respect to the reaction plane, collision centrality and beam energy. For all centralities and transverse momenta, a geometrical distribution of ellipsoidal shape is found in the plane perpendicular to the beam direction with the larger extension perpendicular to the reaction plane. For large transverse momenta, the corresponding eccentricity approaches the initial eccentricity. The eccentricity is smallest for most central collisions, where the shape is almost circular. The magnitude of the tilt angle of the emission ellipsoid in the reaction plane decreases with increasing centrality and increasing transverse momentum. All source radii increase with centrality, largely exhibiting a linear rise with the number of participants, irrespective of transverse momentum. A substantial charge-sign difference of the source radii is found, appearing most pronounced at low transverse momentum. The extracted source parameters are consistent with the extrapolation of their energy dependence down from higher energies.
△ Less
Submitted 26 May, 2020; v1 submitted 16 October, 2019;
originally announced October 2019.
-
Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
Authors:
N. Krawczyk,
B. C. Hiesmayr,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj
, et al. (10 additional authors not shown)
Abstract:
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of…
▽ More
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of the interacting photon. Thus registration of multiple photon scatterings with J-PET enables to determine the polarization of the annihilation photons. In this contribution we present estimates on the physical limitation in the accuracy of the polarization determination of $511$~keV photons with the J-PET detector.
△ Less
Submitted 18 January, 2019;
originally announced January 2019.
-
Sub-threshold production of K^{0}_{s} mesons and Λ hyperons in Au(1.23A GeV)+Au
Authors:
HADES collaboration,
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich
, et al. (91 additional authors not shown)
Abstract:
We present first data on sub-threshold production of K0 s mesons and Λ hyperons in Au+Au collisions at $\sqrt{s_{NN}}$ = 2.4 GeV. We observe an universal <Apart> scaling of hadrons containing strangeness, independent of their corresponding production thresholds. Comparing the yields, their <Apart> scaling, and the shapes of the rapidity and the pt spectra to state-of-the-art transport model (UrQMD…
▽ More
We present first data on sub-threshold production of K0 s mesons and Λ hyperons in Au+Au collisions at $\sqrt{s_{NN}}$ = 2.4 GeV. We observe an universal <Apart> scaling of hadrons containing strangeness, independent of their corresponding production thresholds. Comparing the yields, their <Apart> scaling, and the shapes of the rapidity and the pt spectra to state-of-the-art transport model (UrQMD, HSD, IQMD) predictions, we find that none of the latter can simultaneously describe all observables with reasonable \c{hi}2 values.
△ Less
Submitted 18 December, 2018;
originally announced December 2018.
-
Identical pion intensity interferometry in central Au+Au collisions at 1.23A GeV
Authors:
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
T. Galatyuk
, et al. (92 additional authors not shown)
Abstract:
We investigate identical pion HBT intensity interferometry for central Au+Au collisions at 1.23A GeV. High-statistics $π^-π^-$ and $π^+π^+$ data are measured with HADES at SIS18/GSI. The radius parameters, derived from the correlation function depending on relative momenta in the longitudinal-comoving system and parametrized as three-dimensional Gaussian distribution, are studied as function of tr…
▽ More
We investigate identical pion HBT intensity interferometry for central Au+Au collisions at 1.23A GeV. High-statistics $π^-π^-$ and $π^+π^+$ data are measured with HADES at SIS18/GSI. The radius parameters, derived from the correlation function depending on relative momenta in the longitudinal-comoving system and parametrized as three-dimensional Gaussian distribution, are studied as function of transverse momentum. A substantial charge-sign difference of the source radii is found, particularly pronounced at low transverse momentum. The extracted Coulomb-corrected source parameters agree well with a smooth extrapolation of the center-of-mass energy dependence established at higher energies, extending the corresponding excitation functions down towards a very low energy. Our data would thus rather disfavour any strong energy dependence of the radius parameters in the low energy region.
△ Less
Submitted 1 July, 2019; v1 submitted 15 November, 2018;
originally announced November 2018.
-
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
Authors:
P. Moskal,
N. Krawczyk,
B. C. Hiesmayr,
M. Bała,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. Jasińska,
K. Kacprzak,
L. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
J. Raj,
Z. Rudy
, et al. (9 additional authors not shown)
Abstract:
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on…
▽ More
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82 deg (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40 deg (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
The FAZIA setup: a review on the electronics and the mechanical mounting
Authors:
S. Valdré,
G. Casini,
N. Le Neindre,
M. Bini,
A. Boiano,
B. Borderie,
P. Edelbruck,
G. Poggi,
F. Salomon,
G. Tortone,
R. Alba,
S. Barlini,
E. Bonnet,
R. Bougault,
A. Bougard,
G. Brulin,
M. Bruno,
A. Buccola,
A. Camaiani,
A. Chbihi,
C. Ciampi,
M. Cicerchia,
M. Cinausero,
D. Dell'Aquila,
P. Desrues
, et al. (56 additional authors not shown)
Abstract:
In this paper the technological aspects of the FAZIA array will be explored. After a productive commissioning phase, FAZIA blocks started to measure and give very useful data to explore the physics of Fermi energy heavy-ion reactions. This was possible thanks to many technical measures and innovations developed in the commissioning phase and tuned during the first experimental campaigns. This pape…
▽ More
In this paper the technological aspects of the FAZIA array will be explored. After a productive commissioning phase, FAZIA blocks started to measure and give very useful data to explore the physics of Fermi energy heavy-ion reactions. This was possible thanks to many technical measures and innovations developed in the commissioning phase and tuned during the first experimental campaigns. This paper gives a detailed description of the present status of the FAZIA setup from the electronic and mechanical point of view, trying also to trace a path for new improvements and refinements of the apparatus.
△ Less
Submitted 5 April, 2019; v1 submitted 24 September, 2018;
originally announced September 2018.
-
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
Authors:
K. Dulski,
C. Curceanu,
E. Czerwiński,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
K. Rakoczy,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of ana…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as well as positron annihilation lifetime spectroscopy.
△ Less
Submitted 12 September, 2018;
originally announced September 2018.
-
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
Authors:
J. Raj,
A. Gajos,
C. Curceanu,
E. Czerwinski,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka,
M. Pawlik-Niedzwiecka,
L. Raczynski,
K. Rakoczy
, et al. (9 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables the measurement of both momenta and the polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows the study of time reversal symmetry violation operator which can be constructed solely from the annihilation photons momenta before and after the scattering in the detector.
△ Less
Submitted 4 September, 2018;
originally announced September 2018.
-
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
Authors:
Paweł Kowalski,
Wojciech Wiślicki,
Roman Shopa,
Lech Raczyński,
Konrad Klimaszewski,
Catalina Curceanu,
Eryk Czerwiński,
Kamil Dulski,
Aleksander Gajos,
Marek Gorgol,
Neha Gupta-Sharma,
Beatrix Hiesmayr,
Bożena Jasińska,
Łukasz Kapłon,
Daria Kamińska,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Ewelina Kubicz,
Muhsin Mohammed,
Szymon Niedzwiecki,
Marek Pałka,
Monika Pawlik-Niedźwiecka,
Juhi Raj,
Kamil Rakoczy
, et al. (8 additional authors not shown)
Abstract:
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were…
▽ More
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were performed.
The spatial resolution, the sensitivity, the scatter fraction and the noise equivalent count rate were estimated according to the NEMA norm as a function of the length of the tomograph, number of the detection layers, diameter of the tomographic chamber and for various types of the applied readout. For the single-layer geometry with the diameter of 85 cm, strip length of 100 cm, cross-section of 4 mm x 20 mm and silicon photomultipliers with the additional layer of wavelength shifter as the readout, the spatial resolution (FWHM) in the centre of the scanner is equal to 3 mm (radial, tangential) and 6 mm (axial). For the analogous double-layer geometry with the same readout, diameter and scintillator length, with the strip cross-section of 7 mm x 20 mm, the NECR peak of 300 kcps was reached at 40 kBq/cc activity concentration, the scatter fraction is estimated to about 35% and the sensitivity at the centre amounts to 14.9 cps/kBq. Sensitivity profiles were also determined.
△ Less
Submitted 1 August, 2018;
originally announced August 2018.
-
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
Authors:
G. Korcyl,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
B. Flak,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
M. Kajetanowicz,
D. Kisielewska,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
P. Rajda
, et al. (14 additional authors not shown)
Abstract:
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data…
▽ More
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Feasibility study of the positronium imaging with the J-PET tomograph
Authors:
P. Moskal,
D. Kisielewska,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
S. Sharma,
Shivani,
R. Y. Shopa
, et al. (5 additional authors not shown)
Abstract:
A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibili…
▽ More
A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma quantum. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of about 40 ps. Recent Positron Annihilation Lifetime Spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
△ Less
Submitted 15 January, 2019; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
Authors:
A. Gajos,
C. Curceanu,
E. Czerwiński,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
Z. Rudy,
S. Sharma,
Shivani
, et al. (7 additional authors not shown)
Abstract:
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correl…
▽ More
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.
△ Less
Submitted 19 April, 2018;
originally announced April 2018.
-
Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner
Authors:
R. Masełek,
W. Krzemien,
K. Klimaszewski,
L. Raczyński,
P. Kowalski,
R. Shopa,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka
, et al. (9 additional authors not shown)
Abstract:
The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ deca…
▽ More
The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ decay followed by de-excitation of an excited nucleus. Efficiency, purity and false positive rate are calculated for each isotope as a function of energy deposited threshold, with a hypothesis that signals caused by 511 keV photons deposit smaller values of energy than 1 z 13the selected threshold, while prompt photons deposit larger energy than the threshold. Analysis of the results accompanied with physical properties of radioisotopes suggests using 44 Sc, which is the most promising candidate for medical applications. With the use of GATE and J-POS simulation software, in-phantom scattering was introduced and the best energy deposited threshold value was estimated to be approximately 375 keV. It corresponds to almost 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.
△ Less
Submitted 2 March, 2018;
originally announced March 2018.
-
Centrality determination of Au+Au collisions at 1.23A GeV with HADES
Authors:
HADES collaboration,
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Froehlich,
T. Galatyuk,
J. A. Garzon,
R. Gernhaeuser,
M. Golubeva,
R. Greifenhagen,
F. Guber
, et al. (84 additional authors not shown)
Abstract:
The centrality determination for Au+Au collisions at 1.23A GeV, as measured with HADES at the GSI-SIS18, is described. In order to extract collision geometry related quantities, such as the average impact parameter or number of participating nucleons, a Glauber Monte Carlo approach is employed. For the application of this model to collisions at this relatively low centre-of-mass energy of…
▽ More
The centrality determination for Au+Au collisions at 1.23A GeV, as measured with HADES at the GSI-SIS18, is described. In order to extract collision geometry related quantities, such as the average impact parameter or number of participating nucleons, a Glauber Monte Carlo approach is employed. For the application of this model to collisions at this relatively low centre-of-mass energy of $\sqrt{s_{\mathrm{NN}}} = 2.42$ GeV special investigations were performed. As a result a well defined procedure to determine centrality classes for ongoing analyses of heavy-ion data is established.
△ Less
Submitted 22 May, 2018; v1 submitted 21 December, 2017;
originally announced December 2017.
-
$Σ^0$ production in proton nucleus collisions near threshold
Authors:
J. Adamczewski-Musch,
G. Agakishiev,
O. Arnold,
E. T. Atomssa,
C. Behnke,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo S. Chernenko,
C. Deveaux,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzón,
R. Gernhäuser,
K. Gill,
M. Golubeva,
F. Guber
, et al. (78 additional authors not shown)
Abstract:
The production of $Σ^{0}$ baryons in the nuclear reaction p (3.5 GeV) + Nb (corresponding to $\sqrt{s_{NN}}=3.18$ GeV) is studied with the detector set-up HADES at GSI, Darmstadt. $Σ^{0}$s were identified via the decay $Σ^{0} \rightarrow Λγ$ with subsequent decays $Λ\rightarrow p π^{-}$ in coincidence with a $e^{+}e^{-}$ pair from either external ($γ\rightarrow e^{+} e^{-}$) or internal (Dalitz de…
▽ More
The production of $Σ^{0}$ baryons in the nuclear reaction p (3.5 GeV) + Nb (corresponding to $\sqrt{s_{NN}}=3.18$ GeV) is studied with the detector set-up HADES at GSI, Darmstadt. $Σ^{0}$s were identified via the decay $Σ^{0} \rightarrow Λγ$ with subsequent decays $Λ\rightarrow p π^{-}$ in coincidence with a $e^{+}e^{-}$ pair from either external ($γ\rightarrow e^{+} e^{-}$) or internal (Dalitz decay $γ^{*}\rightarrow e^{+} e^{-}$) gamma conversions. The differential $Σ^0$ cross section integrated over the detector acceptance, i.e. the rapidity interval $0.5 < y < 1.1$, has been extracted as $Δσ_{Σ^{0}} = 2.3 \pm (0.2)^{stat} \pm \left(^{+0.6}_{-0.6}\right)^{sys} \pm (0.2)^{norm}$ mb, yielding the inclusive production cross section in full phase space $σ^{total}_{Σ^{0}} = 5.8 \pm (0.5)^{stat} \pm \left(^{+1.4}_{-1.4}\right)^{sys} \pm (0.6)^{norm} \pm (1.7)^{extrapol}$ mb by averaging over different extrapolation methods. The $Λ_{all}$/$Σ^{0}$ ratio within the HADES acceptance is equal to 2.3 $\pm$ $(0.2)^{stat}$ $\pm$ $(^{+0.6}_{-0.6})^{sys}$. The obtained rapidity and momentum distributions are compared to transport model calculations. The $Σ^{0}$ yield agrees with the statistical model of particle production in nuclear reactions.
△ Less
Submitted 15 November, 2017;
originally announced November 2017.
-
Human Tissues Investigation Using PALS Technique
Authors:
B. Jasińska,
B. Zgardzińska,
G. Chołubek,
M. Gorgol,
K. Wiktor,
K. Wysogld,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
B. Hiesmayr,
B. Jodłowska-Jędrych,
D. Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka
, et al. (12 additional authors not shown)
Abstract:
Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorou…
▽ More
Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorous tissues than for the healthy ones. For most of the patients, the intensity of the free annihilation and ortho-positronium annihilation was smaller for the tumorous than for the healthy tissues. For the first time, in this kind of studies, the $3γ$ fraction of positron annihilation was determined to describe changes in the tissue porosity during morphologic alteration.
△ Less
Submitted 13 November, 2017;
originally announced November 2017.
-
Introduction of total variation regularization into filtered backprojection algorithm
Authors:
L. Raczyński,
W. Wiślicki,
K. Klimaszewski,
W. Krzemień,
P. Kowalski,
R. Shopa,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image…
▽ More
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.
△ Less
Submitted 31 October, 2017;
originally announced November 2017.
-
J-PET: a new technology for the whole-body PET imaging
Authors:
S. Niedźwiecki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
Ł. Kapłon,
D. Kisielewska-Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
△ Less
Submitted 31 October, 2017;
originally announced October 2017.
-
Commissioning of the J-PET detector for studies of decays of positronium atoms
Authors:
E. Czerwiński,
K. Dulski,
P. Białas,
C. Curceanu,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma,
R. Y. Shopa
, et al. (7 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.
△ Less
Submitted 13 November, 2017; v1 submitted 30 October, 2017;
originally announced October 2017.
-
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
Authors:
R. Y. Shopa,
K. Klimaszewski,
P. Kowalski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were…
▽ More
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.
-
Analysis procedure of the positronium lifetime spectra for the J-PET detector
Authors:
K. Dulski,
B. Zgardzinska,
P. Bialas,
C. Curceanu E. Czerwinski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
D. Kisielewska-Kaminska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemiez,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedzwiecka,
S. Niedzwiecki,
M. Palka,
L. Raczynski,
J. Raj,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics…
▽ More
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the J-PET software. We compare its performance with the standard program LT 9.0 by using PALS data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.
-
Time calibration of the J-PET detector
Authors:
M. Skurzok,
M. Silarski,
D. Alfs,
P. Bialas,
Shivani,
C. Curceanu,
E. Czerwinski,
K. Dulski,
A. Gajos,
B. Glowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
D. Kisielewska-Kaminska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedzwiecka,
S. Niedzwiecki,
M. Palka,
L. Raczynski
, et al. (10 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cy…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.
-
Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
Authors:
M. Pałka,
P. Strzempek,
G. Korcyl,
T. Bednarski,
Sz. Niedźwiecki,
P. Białas,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Jasińska,
D. Kamińska,
M. Kajetanowicz,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohhamed,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
N. G. Sharma,
M. Silarski
, et al. (7 additional authors not shown)
Abstract:
In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time measurement of $20$ ps RMS and reconstruct charge of signals, using a simple approach, with deviation from real value smaller than 10$\%$. Utilization of the d…
▽ More
In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time measurement of $20$ ps RMS and reconstruct charge of signals, using a simple approach, with deviation from real value smaller than 10$\%$. Utilization of the differential inputs of an FPGA chip as comparators together with an implementation of a TDC inside an FPGA allowed us to achieve a compact multi-channel system characterized by low power consumption and low production costs. This paper describes realization and functioning of the system comprising 192-channel TDC board and a four mezzanine cards which split incoming signals and discriminate them. The boards have been used to validate a newly developed Time-of-Flight Positron Emission Tomography system based on plastic scintillators. The achieved full system time resolution of $σ$(TOF) $\approx 68$ ps is by factor of two better with respect to the current TOF-PET systems.
△ Less
Submitted 12 July, 2017;
originally announced July 2017.
-
Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
Authors:
L. Raczyński,
W. Wiślicki,
W. Krzemień,
P. Kowalski,
D. Alfs,
T. Bednarski,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (9 additional authors not shown)
Abstract:
In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the Kernel Density Estimation method. We obtain simple, closed-form analytical formulas for time resolutions. The proposed method is validated using signals registered by means of the single detection uni…
▽ More
In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the Kernel Density Estimation method. We obtain simple, closed-form analytical formulas for time resolutions. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built out from 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results, obtained for the J-PET scanner equipped with vacuum tube photomultipliers, are consistent.
△ Less
Submitted 12 July, 2017; v1 submitted 3 June, 2017;
originally announced June 2017.
-
Analysis of the exclusive final state npe$^+$e$^-$ in quasi-free np reaction
Authors:
J. Adamczewski-Musch,
O. Arnold,
E. T. Atomssa,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Finocchiaro,
P. Fonte,
C. Franco,
J. Friese
, et al. (92 additional authors not shown)
Abstract:
We report on the investigation of dielectron production in tagged quasi-free neutron-proton collisions by using a deuteron beam of kinetic energy 1.25 GeV/u in**ing on a liquid hydrogen target. Our measurements with HADES confirm a significant excess of $e^+e^-$ pairs above the $π^{0}$ mass in the exclusive channel $dp \to npe^{+}e^{-}(p_{spect})$ as compared to the exclusive channel…
▽ More
We report on the investigation of dielectron production in tagged quasi-free neutron-proton collisions by using a deuteron beam of kinetic energy 1.25 GeV/u in**ing on a liquid hydrogen target. Our measurements with HADES confirm a significant excess of $e^+e^-$ pairs above the $π^{0}$ mass in the exclusive channel $dp \to npe^{+}e^{-}(p_{spect})$ as compared to the exclusive channel $ppe^{+}e^{-}$ measured in proton-proton collisions at the same energy. That excess points to different bremsstrahlung production mechanisms. Two models were evaluated for the role of the charged pion exchange between nucleons and double-$Δ$ excitation combined with intermediate $ρ$-meson production. Differential cross sections as a function of the $e^+e^-$ invariant mass and of the angles of the virtual photon, proton and electrons provide valuable constraints and encourage further investigations on both experimental and theoretical side.
△ Less
Submitted 24 March, 2017;
originally announced March 2017.
-
Deep sub-threshold φ production and implications for the K+/K- freeze-out in Au+Au collisions
Authors:
J. Adamczewski-Musch,
O. Arnold,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
T. Galatyuk
, et al. (88 additional authors not shown)
Abstract:
We present data on charged kaons (K+-) and φ mesons in Au(1.23A GeV)+Au collisions. It is the first simultaneous measurement of K and φ mesons in central heavy-ion collisions below a kinetic beam energy of 10A GeV. The φ/K- multiplicity ratio is found to be surprisingly high with a value of 0.52 +- 0.16 and shows no dependence on the centrality of the collision. Consequently, the different slopes…
▽ More
We present data on charged kaons (K+-) and φ mesons in Au(1.23A GeV)+Au collisions. It is the first simultaneous measurement of K and φ mesons in central heavy-ion collisions below a kinetic beam energy of 10A GeV. The φ/K- multiplicity ratio is found to be surprisingly high with a value of 0.52 +- 0.16 and shows no dependence on the centrality of the collision. Consequently, the different slopes of the K+ and K- transverse-mass spectra can be explained solely by feed- down, which substantially softens the spectra of K- mesons. Hence, in contrast to the commonly adapted argumentation in literature, the different slopes do not necessarily imply diverging freeze- out temperatures of K+ and K- mesons caused by different couplings to baryons.
△ Less
Submitted 28 November, 2017; v1 submitted 24 March, 2017;
originally announced March 2017.
-
Analysis of pion production data measured by HADES in proton-proton collisions at 1.25 GeV
Authors:
G. Agakishiev,
A. Balanda,
D. Belver,
A. Belyaev,
J. C. Berger-Chen,
A. Blanco,
M. Böhmer,
J. L. Boyard,
P. Cabanelas,
S. Chernenko,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Finocchiaro,
P. Fonte,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzón,
R. Gernhäuser,
K. Göbel,
M. Golubeva,
D. González-Díaz,
F. Guber
, et al. (75 additional authors not shown)
Abstract:
Baryon resonance production in proton-proton collisions at a kinetic beam energy of 1.25 GeV is investigated. The multi-differential data were measured by the HADES collaboration. Exclusive channels with one pion in the final state ($npπ^{+}$ and $ppπ^{0}$) were put to extended studies based on various observables in the framework of a one-pion exchange model and with solutions obtained within the…
▽ More
Baryon resonance production in proton-proton collisions at a kinetic beam energy of 1.25 GeV is investigated. The multi-differential data were measured by the HADES collaboration. Exclusive channels with one pion in the final state ($npπ^{+}$ and $ppπ^{0}$) were put to extended studies based on various observables in the framework of a one-pion exchange model and with solutions obtained within the framework of a partial wave analysis (PWA) of the Bonn-Gatchina group. The results of the PWA confirm the dominant contribution of the $Δ$(1232), yet with a sizable impact of the $N$(1440) and non-resonant partial waves.
△ Less
Submitted 24 March, 2017;
originally announced March 2017.
-
$Δ$(1232) Dalitz decay in proton-proton collisions at T=1.25 GeV measured with HADES
Authors:
J. Adamczewski-Musch,
O. Arnold,
E. T. Atomssa,
C. Behnke,
A. Belounnas,
A. Belyaev,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
L. Chlad,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Filip,
P. Finocchiaro,
P. Fonte,
C. Franco,
J. Friese
, et al. (92 additional authors not shown)
Abstract:
We report on the investigation of $Δ$(1232) production and decay in proton-proton collisions at a kinetic energy of 1.25 GeV measured with HADES. Exclusive dilepton decay channels $ppe^{+}e^{-}$ and $ppe^{+}e^{-}γ$ have been studied and compared with the partial wave analysis of the hadronic $ppπ^{0}$ channel. They allow to access both $Δ^+ \to pπ^0(e^+e^-γ)$ and $Δ^+ \to pe^+e^-$ Dalitz decay cha…
▽ More
We report on the investigation of $Δ$(1232) production and decay in proton-proton collisions at a kinetic energy of 1.25 GeV measured with HADES. Exclusive dilepton decay channels $ppe^{+}e^{-}$ and $ppe^{+}e^{-}γ$ have been studied and compared with the partial wave analysis of the hadronic $ppπ^{0}$ channel. They allow to access both $Δ^+ \to pπ^0(e^+e^-γ)$ and $Δ^+ \to pe^+e^-$ Dalitz decay channels. The perfect reconstruction of the well known $π^0$ Dalitz decay serves as a proof of the consistency of the analysis. The $Δ$ Dalitz decay is identified for the first time and the sensitivity to N-$Δ$ transition form factors is tested. The $Δ$(1232) Dalitz decay branching ratio is also determined for the first time; our result is (4.19 $\pm$ 0.62 syst. $\pm$ 0.34 stat.) $\times $ 10$^{-5}$, albeit with some model dependence.
△ Less
Submitted 24 March, 2017; v1 submitted 22 March, 2017;
originally announced March 2017.
-
Inclusive Λ production in proton-proton collisions at 3.5 GeV
Authors:
J. Adamczewski-Musch,
G. Agakishiev,
O. Arnold,
E. T. Atomssa,
C. Behnke,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
C. Deveaux,
J. Dreyer,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzón,
K. Gill
, et al. (84 additional authors not shown)
Abstract:
The inclusive production of Λ hyperons in proton-proton collisions at $\sqrt{s}$ = 3.18 GeV was measured with HADES at the GSI Helmholtzzentrum für Schwerionenforschung in Darmstadt. The experimental data are compared to a data-based model for individual exclusive Λ production channels in the same reaction. The contributions of intermediate resonances such as Σ(1385), Δ++ or N* are considered in d…
▽ More
The inclusive production of Λ hyperons in proton-proton collisions at $\sqrt{s}$ = 3.18 GeV was measured with HADES at the GSI Helmholtzzentrum für Schwerionenforschung in Darmstadt. The experimental data are compared to a data-based model for individual exclusive Λ production channels in the same reaction. The contributions of intermediate resonances such as Σ(1385), Δ++ or N* are considered in detail. In particular, the result of a partial wave analysis is accounted for the abundant pK$^+$Λ final state. Model and data show a reasonable agreement at mid rapidities, while a difference is found for larger rapidities. A total Λ production cross section in p+p collisions at $\sqrt{s}$ = 3.18 GeV of σ(pp $\to$ Λ + X) = 207.3 $\pm$ 1.3 +6.0 -7.3 (stat.) $\pm$ 8.4 (syst.) +0.4 -0.5 (model) μb is found.
△ Less
Submitted 3 November, 2016;
originally announced November 2016.
-
The $\bf{Λp}$ interaction studied via femtoscopy in p + Nb reactions at $\mathbf{\sqrt{s_{NN}}=3.18} ~\mathrm{\bf{GeV}}$
Authors:
J. Adamczewski-Musch,
G. Agakishiev,
O. Arnold,
E. T. Atomssa,
C. Behnke,
J. C. Berger-Chen,
J. Biernat,
A. Blanco,
C. Blume,
M. Böhmer,
P. Bordalo,
S. Chernenko,
C. Deveaux,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzon,
K. Gill,
M. Golubeva
, et al. (81 additional authors not shown)
Abstract:
We report on the first measurement of $pΛ$ and $pp$ correlations via the femtoscopy method in p+Nb reactions at $\mathrm{\sqrt{s_{NN}}=3.18} ~\mathrm{GeV}$, studied with the High Acceptance Di-Electron Spectrometer (HADES). By comparing the experimental correlation function to model calculations, a source size for $pp$ pairs of…
▽ More
We report on the first measurement of $pΛ$ and $pp$ correlations via the femtoscopy method in p+Nb reactions at $\mathrm{\sqrt{s_{NN}}=3.18} ~\mathrm{GeV}$, studied with the High Acceptance Di-Electron Spectrometer (HADES). By comparing the experimental correlation function to model calculations, a source size for $pp$ pairs of $r_{0,pp}=2.02 \pm 0.01(\mathrm{stat})^{+0.11}_{-0.12} (\mathrm{sys}) ~\mathrm{fm}$ and a slightly smaller value for $pΛ$ of $r_{0,Λp}=1.62 \pm 0.02(\mathrm{stat})^{+0.19}_{-0.08}(\mathrm{sys}) ~\mathrm{fm}$ is extracted. Using the geometrical extent of the particle emitting region, determined experimentally with $pp$ correlations as reference together with a source function from a transport model, it is possible to study different sets of scattering parameters. The $pΛ$ correlation is proven sensitive to predicted scattering length values from chiral effective field theory. We demonstrate that the femtoscopy technique can be used as valid alternative to the analysis of scattering data to study the hyperon-nucleon interaction.
△ Less
Submitted 29 February, 2016;
originally announced February 2016.
-
Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
Authors:
A. Gajos,
D. Kamińska,
E. Czerwiński,
D. Alfs,
T. Bednarski,
P. Białas,
B. Głowacz,
M. Gorgol,
B. Jasińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski
, et al. (6 additional authors not shown)
Abstract:
This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based…
▽ More
This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based on Monte Carlo simulations are presented, which yield a spatial resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm (FWHM) for Z available with the present resolution of J-PET after application of a kinematic fit. Prospects of employment of this method for studying angular correlations of photons in decays of polarized ortho-positronia for the needs of tests of CP and CPT discrete symmetries are also discussed. The new reconstruction method allows for discrimination of background from random three-photon coincidences as well as for application of a novel method for determination of the linear polarization of ortho-positronium atoms, which is also introduced in this work.
△ Less
Submitted 24 February, 2016;
originally announced February 2016.
-
Scatter fraction of the J-PET tomography scanner
Authors:
P. Kowalski,
W. Wiślicki,
L. Raczyński,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
B. Głowacz,
J. Jasińska,
D. Kamińska,
G. Korcyl,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammad,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
Z. Rudy,
M. Silarski,
J. Smyrski,
A. Strzelecki,
A. Wieczorek,
B. Zgardzińska
, et al. (2 additional authors not shown)
Abstract:
A novel Positron Emission Tomography system, based on plastic scintillators, is being developed by the J-PET collaboration. In this article we present the simulation results of the scatter fraction, representing one of the parameters crucial for background studies defined in the NEMA-NU-2-2012 norm. We elaborate an event selection methods allowing to suppress events in which gamma quanta were scat…
▽ More
A novel Positron Emission Tomography system, based on plastic scintillators, is being developed by the J-PET collaboration. In this article we present the simulation results of the scatter fraction, representing one of the parameters crucial for background studies defined in the NEMA-NU-2-2012 norm. We elaborate an event selection methods allowing to suppress events in which gamma quanta were scattered in the phantom or underwent the multiple scattering in the detector. The estimated scatter fraction for the single-layer J-PET scanner varies from 37% to 53% depending on the applied energy threshold.
△ Less
Submitted 17 February, 2016;
originally announced February 2016.
-
Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
Authors:
B. Jasińska,
M. Gorgol,
M. Wiertel,
R. Zaleski,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma
, et al. (8 additional authors not shown)
Abstract:
Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elem…
▽ More
Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elemental analysis performed using scanning electron microscop (SEM) equipped with energy-dispersive X-ray spectroscop EDS show high purity of the investigated materials.
△ Less
Submitted 17 February, 2016;
originally announced February 2016.
-
Sampling FEE and Trigger-less DAQ for the J-PET Scanner
Authors:
G. Korcyl,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
B. Jasińska,
D. Kamińska,
Ł. Kapłon,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski
, et al. (7 additional authors not shown)
Abstract:
In this paper, we present a complete Data Acquisition System (DAQ) together with the readout mechanisms for the J-PET tomography scanner. In general detector readout chain is constructed out of Front-End Electronics (FEE), measurement devices like Time-to-Digital or Analog-to-Digital Converters (TDCs or ADCs), data collectors and storage. We have developed a system capable for maintaining continuo…
▽ More
In this paper, we present a complete Data Acquisition System (DAQ) together with the readout mechanisms for the J-PET tomography scanner. In general detector readout chain is constructed out of Front-End Electronics (FEE), measurement devices like Time-to-Digital or Analog-to-Digital Converters (TDCs or ADCs), data collectors and storage. We have developed a system capable for maintaining continuous readout of digitized data without preliminary selection. Such operation mode results in up to 8 Gbps data stream, therefore it is required to introduce a dedicated module for online event building and feature extraction. The Central Controller Module, equipped with Xilinx Zynq SoC and 16 optical transceivers serves as such true real time computing facility. Our solution for the continuous data recording (trigger-less) is a novel approach in such detector systems and assures that most of the information is preserved on the storage for further, high-level processing. Signal discrimination applies an unique method of using LVDS buffers located in the FPGA fabric.
△ Less
Submitted 16 February, 2016;
originally announced February 2016.
-
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
Authors:
P. Moskal,
O. Rundel,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
K. Giergiel,
M. Gorgol,
B. Jasińska,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
A. Słomski,
M. Silarski,
A. Strzelecki
, et al. (5 additional authors not shown)
Abstract:
Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it ca…
▽ More
Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2 x 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of $\approx$ 0.170 ns for 15 cm axial field-of-view (AFOV) and $\approx$ 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.
△ Less
Submitted 19 March, 2016; v1 submitted 5 February, 2016;
originally announced February 2016.
-
Statistical model analysis of hadron yields in proton-nucleus and heavy-ion collisions at SIS 18 energies
Authors:
G. Agakishiev,
O. Arnold,
A. Balanda,
D. Belver,
A. Belyaev,
J. C. Berger-Chen,
A. Blanco,
M. Böhmer,
J. L. Boyard,
P. Cabanelas,
E. Castro,
S. Chernenko,
M. Destefanis,
F. Dohrmann,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Finocchiaro,
P. Fonte,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzon,
R. Gernhäuser
, et al. (85 additional authors not shown)
Abstract:
The HADES data from p+Nb collisions at center of mass energy of $\sqrt{s_{NN}}$= 3.2 GeV are analyzed by employing a statistical model. Accounting for the identified hadrons $π^0$, $η$, $Λ$, $K^{0}_{s}$, $ω$ allows a surprisingly good description of their abundances with parameters $T_{chem}=(99\pm11)$ MeV and $μ_{b}=(619\pm34)$ MeV, which fits well in the chemical freeze-out systematics found in…
▽ More
The HADES data from p+Nb collisions at center of mass energy of $\sqrt{s_{NN}}$= 3.2 GeV are analyzed by employing a statistical model. Accounting for the identified hadrons $π^0$, $η$, $Λ$, $K^{0}_{s}$, $ω$ allows a surprisingly good description of their abundances with parameters $T_{chem}=(99\pm11)$ MeV and $μ_{b}=(619\pm34)$ MeV, which fits well in the chemical freeze-out systematics found in heavy-ion collisions. In supplement we reanalyze our previous HADES data from Ar+KCl collisions at $\sqrt{s_{NN}}$= 2.6 GeV with an updated version of the statistical model. We address equilibration in heavy-ion collisions by testing two aspects: the description of yields and the regularity of freeze-out parameters from a statistical model fit. Special emphasis is put on feed-down contributions from higher-lying resonance states which have been proposed to explain the experimentally observed $Ξ^-$ excess present in both data samples.
△ Less
Submitted 22 December, 2015;
originally announced December 2015.
-
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
Authors:
D. Kamińska,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
B. Jasińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki,
A. Wieczorek,
W. Wiślicki,
M. Zieliński
, et al. (2 additional authors not shown)
Abstract:
In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence…
▽ More
In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the Standard Model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10-3. The J-PET detector allows to determine those values with better precision thanks to a unique time and angular esolution combined with a high geometrical acceptance. Achieving the aforementioned is possible due to application of polymer scintillators instead of crystals as detectors of annihilation quanta.
△ Less
Submitted 3 September, 2015;
originally announced September 2015.
-
Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy
Authors:
E. Kubicz,
B. Jasińska,
B. Zgardzińska,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
S. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rajfur,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki
, et al. (4 additional authors not shown)
Abstract:
Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic studies on simple microorganisms: brewing yeasts are presented. Lifetime of ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer lived component) for lyophilised and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water - the main component of…
▽ More
Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic studies on simple microorganisms: brewing yeasts are presented. Lifetime of ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer lived component) for lyophilised and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water - the main component of the cell - affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter lived component) for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water an indication of reorganization of yeast in the molecular scale was observed.
Microscopic images of the lyophilised, dried and wet yeasts with best possible resolution were obtained using Inverted Microscopy (IM) and Environmental Scanning Electron Microscopy (ESEM) methods. As a result visible changes to the surface of the cell membrane were observed in ESEM images.
△ Less
Submitted 30 August, 2015;
originally announced September 2015.
-
Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Authors:
N. G. Sharma,
M. Silarski,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
B. Jasińska,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
A. Słomski,
A. Strzelecki,
A. Wieczorek,
W. Wiślicki,
M. Zieliński
, et al. (2 additional authors not shown)
Abstract:
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a…
▽ More
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed.
△ Less
Submitted 29 August, 2015;
originally announced August 2015.
-
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Authors:
A. Wieczorek,
B. Zgardzińska,
B. Jasińska,
M. Gorgol,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
S. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki
, et al. (3 additional authors not shown)
Abstract:
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant h…
▽ More
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
△ Less
Submitted 27 August, 2015;
originally announced August 2015.
-
Processing optimization with parallel computing for the J-PET tomography scanner
Authors:
W. Krzemień,
M. Bała,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
B. Jasińska,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
K. Stola,
A. Strzelecki,
D. Trybek
, et al. (5 additional authors not shown)
Abstract:
The Jagiellonian-PET (J-PET) collaboration is develo** a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were…
▽ More
The Jagiellonian-PET (J-PET) collaboration is develo** a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in case of a large acceptance detector, which works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.
△ Less
Submitted 11 August, 2015;
originally announced August 2015.
-
Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument
Authors:
L. Raczynski,
P. Moskal,
P. Kowalski,
W. Wislicki,
T. Bednarski,
P. Bialas,
E. Czerwinski,
A. Gajos,
L. Kaplon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
T. Kozik,
W. Krzemien,
E. Kubicz,
Sz. Niedzwiecki,
M. Palka,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Slomski,
J. Smyrski,
A. Strzelecki,
A. Wieczorek
, et al. (2 additional authors not shown)
Abstract:
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the n…
▽ More
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to Compress Sensing theory, information about the shape and amplitude of the signals is recovered. In this paper we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50 ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
△ Less
Submitted 8 August, 2015; v1 submitted 14 July, 2015;
originally announced July 2015.
-
K*(892)+ production in proton-proton collisions at E_beam = 3.5 GeV
Authors:
HADES Collaboration,
G. Agakishiev,
O. Arnold,
D. Belver,
A. Belyaev,
J. C. Berger-Chen,
A. Blanco,
M. Böhmer,
J. L. Boyard,
P. Cabanelas,
S. Chernenko,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Finocchiaro,
P. Fonte,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzón,
R. Gernhäuser,
K. Göbel,
M. Golubeva,
D. González-Díaz
, et al. (74 additional authors not shown)
Abstract:
We present results on the K*(892)+ production in proton-proton collisions at a beam energy of E = 3.5 GeV, which is hitherto the lowest energy at which this mesonic resonance has been observed in nucleon-nucleon reactions. The data are interpreted within a two-channel model that includes the 3-body production of K*(892)+ associated with the Lambda- or Sigma-hyperon. The relative contributions of b…
▽ More
We present results on the K*(892)+ production in proton-proton collisions at a beam energy of E = 3.5 GeV, which is hitherto the lowest energy at which this mesonic resonance has been observed in nucleon-nucleon reactions. The data are interpreted within a two-channel model that includes the 3-body production of K*(892)+ associated with the Lambda- or Sigma-hyperon. The relative contributions of both channels are estimated. Besides the total cross section sigma(p+p -> K*(892)+ + X) = 9.5 +- 0.9 +1.1 -0.9 +- 0.7 mub, that adds a new data point to the excitation function of the K*(892)+ production in the region of low excess energy, transverse momenta and angular spectra are extracted and compared with the predictions of the two-channel model. The spin characteristics of K*(892)+ are discussed as well in terms of the spin-alignment.
△ Less
Submitted 22 May, 2015;
originally announced May 2015.