Motion rejection and spectral unmixing for accurate estimation of in vivo oxygen saturation using multispectral optoacoustic tomography
Authors:
Mitradeep Sarkar,
Mailyn Pérez-Liva,
Gilles Renault,
Bertrand Tavitian,
Jérôme Gateau
Abstract:
Multispectral Optoacoustic Tomography (MSOT) uniquely enables spatial map** in high resolution of oxygen saturation (SO$_2$), with potential applications in studying pathological complications and therapy efficacy. MSOT offers seamless integration with ultrasonography, by using a common ultrasound detector array. However, MSOT relies on multiple successive acquisitions of optoacoustic (OA) image…
▽ More
Multispectral Optoacoustic Tomography (MSOT) uniquely enables spatial map** in high resolution of oxygen saturation (SO$_2$), with potential applications in studying pathological complications and therapy efficacy. MSOT offers seamless integration with ultrasonography, by using a common ultrasound detector array. However, MSOT relies on multiple successive acquisitions of optoacoustic (OA) images at different optical wavelengths and the low frame rate of OA imaging makes the MSOT acquisition sensitive to body/respiratory motion. Moreover, estimation of SO$_2$ is highly sensitive to noise, and artefacts related to the respiratory motion of the animal were identified as the primary source of noise in MSOT.In this work, we propose a two-step image processing method for SO$_2$ estimation in deep tissues. First, to mitigate motion artefacts, we propose a method of selection of OA images acquired only during the respiratory pause of the animal, using ultrafast ultrasound images (USIs) acquired immediately after each OA acquisition (USI acquisition duration of 1.4 ms and a total delay of 7 ms). We show that gating is more effective using USIs than OA images at different optical wavelengths. Secondly, we propose a novel method which can estimate directly the SO$_2$ value of a pixel and at the same time evaluate the amount of noise present in that pixel. Hence, the method can efficiently eliminate the pixels dominated by noise from the final SO$_2$ map. Our post-processing method is shown to outperform conventional methods for SO$_2$ estimation, and the method was validated by in vivo oxygen challenge experiments.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
High Resolution 3D Ultrasonic Breast Imaging by Time-Domain Full Waveform Inversion
Authors:
Felix Lucka,
Mailyn Pérez-Liva,
Bradley E. Treeby,
Ben T. Cox
Abstract:
Ultrasound tomography (UST) scanners allow quantitative images of the human breast's acoustic properties to be derived with potential applications in screening, diagnosis and therapy planning. Time domain full waveform inversion (TD-FWI) is a promising UST image formation technique that fits the parameter fields of a wave physics model by gradient-based optimization. For high resolution 3D UST, it…
▽ More
Ultrasound tomography (UST) scanners allow quantitative images of the human breast's acoustic properties to be derived with potential applications in screening, diagnosis and therapy planning. Time domain full waveform inversion (TD-FWI) is a promising UST image formation technique that fits the parameter fields of a wave physics model by gradient-based optimization. For high resolution 3D UST, it holds three key challenges: Firstly, its central building block, the computation of the gradient for a single US measurement, has a restrictively large memory footprint. Secondly, this building block needs to be computed for each of the $10^3-10^4$ measurements, resulting in a massive parallel computation usually performed on large computational clusters for days. Lastly, the structure of the underlying optimization problem may result in slow progression of the solver and convergence to a local minimum. In this work, we design and evaluate a comprehensive computational strategy to overcome these challenges: Firstly, we exploit a gradient computation based on time reversal that dramatically reduces the memory footprint at the expense of one additional wave simulation per source. Secondly, we break the dependence on the number of measurements by using source encoding (SE) to compute stochastic gradient estimates. Also we describe a more accurate, TD-specific SE technique with a finer variance control and use a state-of-the-art stochastic LBFGS method. Lastly, we design an efficient TD multi-grid scheme together with preconditioning to speed up the convergence while avoiding local minima. All components are evaluated in extensive numerical proof-of-concept studies simulating a bowl-shaped 3D UST breast scanner prototype. Finally, we demonstrate that their combination allows us to obtain an accurate 442x442x222 voxel image with a resolution of 0.5mm using Matlab on a single GPU within 24h.
△ Less
Submitted 20 September, 2021; v1 submitted 1 February, 2021;
originally announced February 2021.