-
The Data Processing Pipeline for the MUSE Instrument
Authors:
Peter M. Weilbacher,
Ralf Palsa,
Ole Streicher,
Roland Bacon,
Tanya Urrutia,
Lutz Wisotzki,
Simon Conseil,
Bernd Husemann,
Aurélien Jarno,
Andreas Kelz,
Arlette Pécontal-Rousset,
Johan Richard,
Martin M. Roth,
Fernando Selman,
Joël Vernet
Abstract:
Processing of raw data from modern astronomical instruments is nowadays often carried out using dedicated software, so-called "pipelines" which are largely run in automated operation. In this paper we describe the data reduction pipeline of the Multi Unit Spectroscopic Explorer (MUSE) integral field spectrograph operated at ESO's Paranal observatory. This spectrograph is a complex machine: it reco…
▽ More
Processing of raw data from modern astronomical instruments is nowadays often carried out using dedicated software, so-called "pipelines" which are largely run in automated operation. In this paper we describe the data reduction pipeline of the Multi Unit Spectroscopic Explorer (MUSE) integral field spectrograph operated at ESO's Paranal observatory. This spectrograph is a complex machine: it records data of 1152 separate spatial elements on detectors in its 24 integral field units. Efficiently handling such data requires sophisticated software, a high degree of automation and parallelization. We describe the algorithms of all processing steps that operate on calibrations and science data in detail, and explain how the raw science data gets transformed into calibrated datacubes. We finally check the quality of selected procedures and output data products, and demonstrate that the pipeline provides datacubes ready for scientific analysis.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
The MUSE Data Reduction Pipeline: Status after Preliminary Acceptance Europe
Authors:
Peter M. Weilbacher,
Ole Streicher,
Tanya Urrutia,
Arlette Pécontal-Rousset,
Aurélien Jarno,
Roland Bacon
Abstract:
MUSE, a giant integral field spectrograph, is about to become the newest facility instrument at the VLT. It will see first light in February 2014. Here, we summarize the properties of the instrument as built and outline functionality of the data reduction system, that transforms the raw data that gets recorded separately in 24 IFUs by 4k CCDs, into a fully calibrated, scientifically usable data cu…
▽ More
MUSE, a giant integral field spectrograph, is about to become the newest facility instrument at the VLT. It will see first light in February 2014. Here, we summarize the properties of the instrument as built and outline functionality of the data reduction system, that transforms the raw data that gets recorded separately in 24 IFUs by 4k CCDs, into a fully calibrated, scientifically usable data cube. We then describe recent work regarding geometrical calibration of the instrument and testing of the processing pipeline, before concluding with results of the Preliminary Acceptance in Europe and an outlook to the on-sky commissioning.
△ Less
Submitted 30 June, 2015;
originally announced July 2015.
-
A MUSE map of the central Orion Nebula (M 42)
Authors:
Peter M. Weilbacher,
Ana Monreal-Ibero,
Wolfram Kollatschny,
Adam Ginsburg,
Anna F. McLeod,
Sebastian Kamann,
Christer Sandin,
Ralf Palsa,
Lutz Wisotzki,
Roland Bacon,
Fernando Selman,
Jarle Brinchmann,
Joseph Caruana,
Andreas Kelz,
Thomas Martinsson,
Arlette Pécontal-Rousset,
Johan Richard,
Martin Wendt
Abstract:
We present a new integral-field spectroscopic dataset of the central part of the Orion Nebula (M 42), observed with the MUSE instrument at the ESO VLT. We reduced the data with the public MUSE pipeline. The output products are two FITS cubes with a spatial size of ~5.9'x4.9' (corresponding to ~0.76 pc x 0.63 pc) and a contiguous wavelength coverage of 4595...9366 Angstrom, spatially sampled at 0.2…
▽ More
We present a new integral-field spectroscopic dataset of the central part of the Orion Nebula (M 42), observed with the MUSE instrument at the ESO VLT. We reduced the data with the public MUSE pipeline. The output products are two FITS cubes with a spatial size of ~5.9'x4.9' (corresponding to ~0.76 pc x 0.63 pc) and a contiguous wavelength coverage of 4595...9366 Angstrom, spatially sampled at 0.2". We provide two versions with a sampling of 1.25 Angstrom and 0.85 Angstrom in dispersion direction. Together with variance cubes these files have a size of 75 and 110 GiB on disk. They represent one of the largest integral field mosaics to date in terms of information content. We make them available for use in the community. To validate this dataset, we compare world coordinates, reconstructed magnitudes, velocities, and absolute and relative emission line fluxes to the literature and find excellent agreement. We derive a two-dimensional map of extinction and present de-reddened flux maps of several individual emission lines and of diagnostic line ratios. We estimate physical properties of the Orion Nebula, using the emission line ratios [N II] and [S III] (for the electron temperature $T_e$) and [S II] and [Cl III] (for the electron density $N_e$), and show two-dimensional images of the velocity measured from several bright emission lines.
△ Less
Submitted 30 June, 2015;
originally announced July 2015.
-
Advanced Data Reduction Techniques for MUSE
Authors:
Peter M. Weilbacher,
Joris Gerssen,
Martin M. Roth,
Petra Boehm,
Arlette Pecontal-Rousset
Abstract:
MUSE, a 2nd generation VLT instrument, will become the world's largest integral field spectrograph. It will be an AO assisted instrument which, in a single exposure, covers the wavelength range from 465 to 930 nm with an average resolution of 3000 over a field of view of 1'x1' with 0.2'' spatial sampling. Both the complexity and the rate of the data are a challenge for the data processing of thi…
▽ More
MUSE, a 2nd generation VLT instrument, will become the world's largest integral field spectrograph. It will be an AO assisted instrument which, in a single exposure, covers the wavelength range from 465 to 930 nm with an average resolution of 3000 over a field of view of 1'x1' with 0.2'' spatial sampling. Both the complexity and the rate of the data are a challenge for the data processing of this instrument.
We will give an overview of the data processing scheme that has been designed for MUSE. Specifically, we will use only a single resampling step from the raw data to the reduced data product. This allows us to improve data quality, accurately propagate variance, and minimize spreading of artifacts and correlated noise. This approach necessitates changes to the standard way in which reduction steps like wavelength calibration and sky subtraction are carried out, but can be expanded to include combination of multiple exposures.
△ Less
Submitted 12 February, 2009; v1 submitted 3 February, 2009;
originally announced February 2009.
-
Probing unexplored territories with MUSE: a second generation instrument for the VLT
Authors:
R. Bacon,
S. Bauer,
P. Boehm,
D. Boudon,
S. Brau-Nogue,
P. Caillier,
L. Capoani,
C. M. Carollo,
N. Champavert,
T. Contini,
E. Daguise,
D. Dalle,
B. Delabre,
J. Devriendt,
S. Dreizler,
J. Dubois,
M. Dupieux,
J. P. Dupin,
E. Emsellem,
P. Ferruit,
M. Franx,
G. Gallou,
J. Gerssen,
B. Guiderdoni,
T. Hahn
, et al. (35 additional authors not shown)
Abstract:
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT panoramic integral-field spectrograph under preliminary design study. MUSE has a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the VLT ground layer adaptive optics ESO facility using four laser guide stars. The simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE couples the dis…
▽ More
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT panoramic integral-field spectrograph under preliminary design study. MUSE has a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the VLT ground layer adaptive optics ESO facility using four laser guide stars. The simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE couples the discovery potential of a large imaging device to the measuring capabilities of a high-quality spectrograph, while taking advantage of the increased spatial resolution provided by adaptive optics. This makes MUSE a unique and tremendously powerful instrument for discovering and characterizing objects that lie beyond the reach of even the deepest imaging surveys. MUSE has also a high spatial resolution mode with 7.5x7.5 arcsec**2 field of view sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain diffraction limited data-cubes in the 600-930 nm wavelength range. Although the MUSE design has been optimized for the study of galaxy formation and evolution, it has a wide range of possible applications; e.g. monitoring of outer planets atmosphere, environment of young stellar objects, super massive black holes and active nuclei in nearby galaxies or massive spectroscopic surveys of stellar fields in the Milky Way and nearby galaxies.
△ Less
Submitted 13 June, 2006;
originally announced June 2006.